Datasheet

G6RN
PCB Power Relay
Miniature Power Relay for
Switching 8 A
• Low-profile height of 15 mm (approx. 60% the height of the Omron
G2R model).
• Capable of switching with 8 A at 250 VAC despite its small size.
• High sensitivity with 220mW power consumption.
• Offers high insulation with insulation distance of 8 mm and impulse
withstand voltage of 10kV between coil and contacts.
• Satisfies ambient operating temperature requirement of 85°C.
• Standard model conforms to VDE standards.
RoHS Compliant
■Model Number Legend
■Application Examples
G 6 R N -@ @
——
• Control equipments
■Characteristics
1 2
1. Number of Poles
1: 1-pole
2. Contact Form
None: SPDT (1c)
A: SPST-NO (1a)
■Ordering Information
Classification
Enclosure
rating
Standard
Fully sealed
Contact form
SPST-NO (1a)
SPDT (1c)
Terminal shape
PCB
terminals
Model
G6RN-1A
G6RN-1
Rated coil
voltage
5, 6, 12 VDC
24 VDC
5, 6, 12 VDC
24 VDC
Minimun
packing unit
20 pcs/tube
Note. When ordering, add the rated coil voltage to the model number.
Example: G6RN-1A DC5
Rated coil voltage
However, the notation of the coil voltage on the product case will be marked as @@VDC.
Contact resistance *1
Operate time
Release time
Insulation resistance *2
Between
coil and
contacts
Dielectric
Between
strength
contacts of
the same
polarity
Impulse withstand
voltage (between coil
and contacts)
Between
Insulation
coil and
distance
contacts
G
6
R
N
100 mΩ max.
15 ms max.
5 ms max.
1,000 MΩ min.
4,000 VAC, 50/60 Hz for 1 min
1,000 VAC, 50/60 Hz for 1 min
10,000 V (1.2 x 50 μs)
Clearance: 8 mm,
Creepage: 8 mm
10 to 55 to 10 Hz, 0.75 mm
single amplitude
(1.5 mm double amplitude)
Vibration
10 to 55 to 10 Hz
resistance
NO: 0.75 mm single amplitude
Malfunction (1.5 mm double amplitude)
NC: 0.4 mm single amplitude
(0.8 mm double amplitude)
Destruction 1,000 m/s2
Shock
NO: 100 m/s2
resistance Malfunction
NC:: 50 m/s2
10,000,000 operations min.
Mechanical
(at 36,000 operations/hr)
50,000 operations min.
(8 A at 250 VAC, resistive load)
Durability
50,000 operations min.
Electrical *3
(5 A at 30 VDC, resistive load)
(at 360 operations/hr under
rated load)
Failure rate (P level)
10 mA at 5 VDC
(reference value) *4
Ambient operating
-40°C to 85°C (with no icing or
temperature
condensation)
Ambient operating
5% to 85%
humidity
Weight
Approx. 9 g
Destruction
■Ratings
●Coil
Item
Rated voltage
5 VDC
6 VDC
12 VDC
24 VDC
Rated
current
(mA)
Coil
resistance
(Ω)
43.9
36.6
18.3
9.2
114
164
655
2,620
Must operate Must release
Max.
voltage
voltage
voltage
(V)
(V)
(V)
% of rated voltage
70% max.
10% min.
150%
(at 23°C)
Power
consumption
(mW)
Approx. 220
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of
±10%.
*2.
The operating characteristics are measured at a coil temperature of 23°C.
*3.
The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
●Contacts
Load
Resistive load
Item
Contact type
Single
Ag-Alloy + gold plating
Contact material
(Cd free)
8 A at 250 VAC
Rated load
5 A at 30 VDC
Rated carry
8A
current
Max. switching
250 VAC, 30 VDC
voltage
Max. switching
8A
current
Note. The data given above are initial values.
*1.
Measurement conditions: 5 VDC, 1 A, voltage drop
method.
*2.
Measurement conditions: The insulation resistance
was measured with a 500 VDC megohmmeter at the
same locations as the dielectric strength was
measured.
*3.
Test conditions: With diode
*4.
This value was measured at a switching frequency of
120 operations/min.
1
G6RN
PCB Power Relay
■Engineering Data
50
30
DC resistive load
AC resistive load
10
8
5
3
●Ambient Temperature vs.
Maximum Coil Voltage
100
Maximum coil voltage (%)
●Durability
Durability (x 104 operations)
Switching current (A)
●Maximum Switching Capacity
250 VAC resistive load
30 VDC resistive load
50
30
10
200
180
160
150
140
130
120
1
5
0.5
3
110
100
0.3
80
0.1
0
3
5
10
30 50 100
250 500
0
2
4
6
Switching Voltage (V)
Operate/Release voltage (percentage of rated value) (%)
G
6
R
N
80
Y
1,000
X
1,000
Z
1,000
60
contact B
88.2
40
1,000
Y'
-20
0
20
40
60
80
50
60
70
Unit: m/s2
Sample: G6RN-1 24 VDC
Number of Relays: 5 pcs
Test conditions: The value at which
malfunction occurred was measured
after applying shock to the test piece 3
times each in 6 directions along 3 axes.
Standard value: 100m/s2 at contact A,
50m/s2 at contact B
Y
Shock direction
X
X'
Z
Z'
100
Y'
Ambient Temperature (°C)
■Dimensions
PCB Mounting Holes
(Bottom View)
G6RN-1
Terminal Arrangement/
Internal Connections
(Bottom View)
10±0.5
28.5±0.5
Five, 1.3-dia. holes
(1.19)
15±0.5
3.5
0.5
19
(1.19)
19±0.1
G6RN-1A
PCB Mounting Holes
(Bottom View)
4
3
(No coil polarity)
Four, 1.3-dia. holes
(1.19)
3.5
5.1
1
2
7.62±0.1
0.5
(1.19)
7.62
19±0.1
(1.6)
2
2
Terminal Arrangement/
Internal Connections
(Bottom View)
10±0.5
15±0.5
19
5
(1.5)
3.2±0.1 3.2±0.1
(1.6)
3.2
28.5±0.5
1
7.62±0.1
7.62
3.2
80
90 100
Ambient Temperature (°C)
1,000
X'
1,000
Z'
max.
X
min.
20
40
Note. The maximum coil voltage refers to the
maximum value in a varying range of operating
power voltage, not a continuous voltage.
contact A
max.
X
min.
0
-40
10
●Shock Malfunction
G6RN-1
Must operate voltage
Must release voltage
Sample:
G6RN-1 12 VDC
Number of Relays:
5 pcs
8
Switching Current (A)
●Ambient Temperature vs.
Maximum Coil Voltage
100
0
-40 20 23 30
1
5.1±0.1 (2.8)
5
(No coil polarity)
3
G6RN
PCB Power Relay
■Approved Standards
●The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in
this catalog.
UL Recognized
(File No. E41515)
CSA Certified
(File No. 31928)
Model
Number of
poles
Coil ratings
1
5 to 24 VDC
G6RN-1
EN/TÜV Certified
Model
Number of test
operations
Contact ratings
8 A, 250 VAC 85°C
8 A, 30 VDC 85°C
6,000
(Certificate No. 6135)
Number of
poles
Coil ratings
Contact ratings
Approved switching
operations
1
5, 6, 12, 24 VDC
8 A, 250 VAC (Resistive) 85°C
10,000
G6RN-1
G6RN-1A
Creepage distance
8 mm
Clearance distance
8 mm
Insulation material group
IIIa
Rated Insulation voltage
250 V
Pollution degree
2
Rated voltage system
250 V
Overvoltage category
III
Tracking Index of relay base
PTI 250 V min. (housing parts)
Flammability class according to UL94
V-0
Ball pressure test (IEC 60695-10-2)
160°C
G
6
R
N
■Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. J182-E1-03
0316(0207)(O)
3