HONEYWELL 19U030PG1K/L

Pressure Sensors
Low-Cost, Stainless Steel, Isolated Sensors
FEATURES
• Low cost
• Rugged, isolated stainless
steel package
• Small size
• Reliable semiconductor
technology
• Calibrated and
temperature compensated
• Absolute and gage
pressures
• Vacuum compatible,
isolated sensors
• 0 psi to 3 psi to, 0 psi to
500 psi
TYPICAL APPLICATIONS
• Industrial controls
• Process control systems
• Industrial automation and
flow control
• Pressure calibrators
19 mm Series
Honeywell’s stainless steel 19C, 19U, and 19 Vacuum Gage Series
sensors were developed for pressure applications that involve measurement
of hostile media in harsh environments compatible with 316 stainless steel.
The special Vacuum Gage Series sensors are specifically designed for
applications that can be exposed to vacuum.
The 19C Series are calibrated and temperature compensated. They are
available for use with either a constant voltage or current source. They
feature a variety of pressure connections to allow use in a wide range of
OEM (Original Equipment Manufacturer) equipment. The 19U Series is
uncompensated for applications that use their own specialized circuit
designs.
The 19C and 19U Series sensors are rugged and reliable transducers for
use in a wide variety of pressure sensing applications where corrosive
liquids or gases are monitored.
19C, 19U, AND 19 VACUUM GAGE EQUIVALENT CIRCUIT
WARNING
PERSONAL INJURY
DO NOT USE these
products as safety or
emergency stop devices or
in any other application
where failure of the product
could result in personal
injury.
Failure to comply with
these instructions could
result in death or serious
injury.
Sensing and Control
WARNING
MISUSE OF DOCUMENTATION
• The information presented in this product sheet is for reference only. Do
not use this document as a product installation guide.
• Complete installation, operation, and maintenance information is provided
in the instructions supplied with each product.
Failure to comply with these instructions could result in death or
serious injury.
Pressure Sensors
Low-Cost, Stainless Steel, Isolated Sensors
19 mm Series
PRESSURE SENSOR CHARACTERISTICS – ALL DEVICES
Environmental specifications
Compensated temperature range
Operating temperature range
Storage temperature range
Vibration
Shock
Life
Insulation resistance
Maximum ratings
Voltage version “K”
Voltage version “L”
0 °C to 82 °C [32 °F to 180 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
10 G at 20 Hz to 2000 Hz
100 G for 11 ms
1 million cycles min.
100 mΩ at 50 Vdc
Supply voltage VS = +15 Vdc
Supply current IS = +2.0 mA
PRESSURE RANGE SPECIFICATIONS (19C, 19U)
Catalog Listing
19(C,U) 003P G (1…9) (K/L)
19(C,U) 005P G (1…9) (K/L)
19(C,U) 010P G (1…9) (K/L)
19(C,U) 015P (A,G,V) (1…9) (K/L)
19(C,U) 030P (A,G,V) (1…9) (K/L)
19(C,U) 050P (A,G,V) (1…9) (K/L)
19(C,U) 100P (A,G,V) (1…9) (K/L)
19(C,U) 200P (A,G,V) (1…9) (K/L)
19(C,U) 300P (A,G,V) (1…9) (K/L)
19(C,U) 500P (A,G,V) (1…9) (K/L)
Pressure range
0 psig to 3 psig
0 psig to 5 psig
0 psig to 10 psig
0 psi to 15 psi
0 psi to 30 psi
0 psi to 50 psi
0 psi to 100 psi
0 psi to 200 psi
0 psi to 300 psi
0 psi to 500 psi
Proof pressure
9 psig
15 psig
30 psig
45 psi
90 psi
150 psi
300 psi
600 psi
900 psi
1200 psi
(7)
Burst pressure
15 psig
25 psig
50 psig
75 psi
150 psi
250 psi
500 psi
1000 psi
1500 psi
2400 psi
(8)
Notes:
7. The maximum pressure that can be applied without changing the transducer’s performance or accuracy.
8.The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer case.
19C SERIES PERFORMANCE CHARACTERISTICS
(1)
Characteristic
Zero pressure offset
(2)
Full-scale span
(2)
Full-scale span (3 psi and 5 psi “K” units only)
(3)
Pressure non-linearity
(3)
Pressure hysteresis
Repeatability
(4)
Temp. effect on span
(4)
Temp. effect on offset
(4)
Temp. effect on span (0 psi to 3 psi and 0 psi to 5 psi only)
(4)
Temp. effect on offset (0 psi to 3 psi and 0 psi to 5 psi only)
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F])
(5)
Long-term stability of offset and span
(6)
Response time
(9)
Common mode voltage (voltage version “K”)
Input impedance (current version “L”)
Input impedance (voltage version “K”)
Output resistance
2 Honeywell • Sensing and Control
Minimum
-2
98
48
–
–
–
–
–
–
–
–
–
–
0.5
2.0
8.0
3.0
Typical
0
100
50
±0.1
±0.015
±0.010
±0.5
±0.5
–
–
±0.1
±0.1
0.1
1.3
4.5
25
4.5
Maximum
2
102
52
±0.25
±0.030
±0.030
±1.0
±1.0
±2.0
±2.0
±0.3
±0.3
–
2.0
8.0
50
6.0
Unit
mV
mV
mV
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
ms
Vdc
kΩ
kΩ
kΩ
Pressure Sensors
Low-Cost, Stainless Steel, Isolated Sensors
19U SERIES PERFORMANCE CHARACTERISTICS
19 mm Series
(1)
Characteristic
Zero pressure offset
(2)
Full-scale span
(2)
Full-scale span (3 psi and 5 psi only)
(3)
Pressure non-linearity
(3)
Pressure hysteresis
Repeatability
(10)
Temp. coefficient of resistance (0 °C to 82 °C [32 °F to 180 °F])
(10)
Temp. coefficient of offset (0 °C to 82 °C [32 °F to 180 °F])
(10)
Temp. coefficient of span (0 °C to 82 °C [32 °F to 180 °F])
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F])
(5)
Long-term stability of offset and span
(6)
Response time
Input resistance
Output resistance
Minimum
-7.5
35
20
–
–
–
2700
–
360
–
–
–
4.00
4.00
Typical
1.0
40
30
±0.1
±0.015
±0.010
3420
30
720
±0.1
±0.1
±0.1
4.75
4.75
Maximum
7.5
60
40
±0.25
±0.030
±0.030
4500
–
1260
±0.3
±0.3
–
6.0
6.0
19C VACUUM GAGE COMPENSATED SERIES PERFORMANCE CHARACTERISTICS
Characteristic
Zero pressure offset (at 0 psig)
(2)
Full-scale span (0 psig to positive full-scale)
(3)
Pressure non-linearity
(3)
Pressure hysteresis
Repeatability
(4)
Temp. effect on span
(4)
Temp. effect on offset
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F])
(5)
Long-term stability of offset and span
(6)
Response time
(9)
Common mode voltage (voltage version “K”)
Input impedance (current version “L”)
Input impedance (voltage version “K”)
Output resistance
Minimum
-2
98
–
–
–
–
–
–
–
–
0.5
1.5
8.0
3.0
Typical
0
100
±0.1
±0.015
±0.010
±0.5
±0.5
±0.1
±0.1
0.1
1.3
4.5
25
4.5
(1)
Maximum
2
102
±0.25
±0.030
±0.030
±1.0
±1.0
±0.3
±0.3
–
2.0
8.0
50
6.0
19U VACUUM GAGE UNCOMPENSATED SERIES PERFORMANCE CHARACTERISTICS
Characteristic
Zero pressure offset
(2)
Full-scale span (0 psig to positive full-scale)
(3)
Pressure non-linearity
(3)
Pressure hysteresis
Repeatability
(10)
Temp. coefficient of resistance (0 °C to 82 °C [32 °F to 180 °F])
(10)
Temp. coefficient of offset (0 °C to 82 °C [32 °F to 180 °F])
(10)
Temp. coefficient of span (0 °C to 82 °C [32 °F to 180 °F])
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F])
(5)
Long-term stability of offset and span
(6)
Response time
Input resistance
Output resistance
Honeywell • Sensing and Control
Minimum
-7.5
35
–
–
–
2700
–
360
–
–
–
4.00
4.00
Typical
1.0
40
±0.1
±0.015
±0.010
3420
30
720
±0.1
±0.1
±0.1
4.75
4.75
Unit
mV/V
mV/V
mV/V
%FSS
%FSS
%FSS
ppm/°C
µV/V/°C
ppm/°C
%FSS
%FSS
ms
kΩ
kΩ
Unit
mV
mV
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
ms
Vdc
kΩ
kΩ
kΩ
(1)
Maximum
7.5
60
±0.25
±0.030
±0.030
4500
–
1260
±0.3
±0.3
–
6.0
6.0
Unit
mV/V
mV/V
%FSS
%FSS
%FSS
ppm/°C
µV/V/°C
ppm/°C
%FSS
%FSS
ms
kΩ
kΩ
3
Pressure Sensors
Low-Cost, Stainless Steel, Isolated Sensors
19 mm Series
NOTES
1. Reference conditions (unless otherwise noted): TA = 25 °C [77 °F]; 19C Supply VS = 10 Vdc ±0.01 Vdc or
IS = 1.5 mA ±0.0015 mA; 19U Supply VS = 5 Vdc ±0.01 Vdc or I = 1.0 mA ±0.0015 mA
2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero
pressure. FSS is ratiometric to supply voltage.
3. Pressure non-linearity is based on best-fit straight line from zero to the full-scale pressure. Pressure hysteresis is the
maximum output difference at any point within the operation pressure range for increasing and decreasing pressure.
4. Maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25 °C [77 °F]
reading.
5. Long-term stability over a six-month period.
6. Response time for a 0 psi to FSS pressure step change, 10 % to 90 % rise time.
9. Common mode voltage as measured from output to ground. For higher levels of common mode voltage, contact factory.
10. The error band resulting from a maximum deviation of a transducer’s output parameter (offset, span, or resistance) as
temperature is varied 25 °C [77 °F] to any other temperature within the specified range (0 °C to 82 °C [32 °F to 180 °F]).
This parameter is not 100 % tested and is guaranteed by process design and tested on a sample basis only.
Temperature coefficient of span is evaluated using a constant current source.
PHYSICAL DIMENSIONS, for reference only, mm [in]
Package 1 (see note): Cell Package
Note: Non-concentricity effects at the diaphragm weld area may cause runout of up to ±0.006 in between the upper and lower portions of
the sensor body. (It is recommended to use a counter bore to mate with this device to allow for this non-concentricity).
Package 2: Flush Mount Package
4 Honeywell • Sensing and Control
Pressure Sensors
Low-Cost, Stainless Steel, Isolated Sensors
19 mm Series
Package 3: Flush Mount with Flange
Package 4: Male 1/8-27 NPT
Package 5: Male 1/4-18 NPT
Honeywell • Sensing and Control
5
Pressure Sensors
Low-Cost, Stainless Steel, Isolated Sensors
19 mm Series
Package 6: Male 7/16 UNF
Package 7: Male 1/4 BSPP
Package 8: Euro Ring (See note)
Note: Non-concentricity effects at the diaphragm weld area may cause runout of up to ±0.006 in between the upper and
lower portions of the sensor body. (It is recommended to use a counter bore to mate with this device to allow for this nonconcentricity).
6 Honeywell • Sensing and Control
Pressure Sensors
Low-Cost, Stainless Steel, Isolated Sensors
19 mm Series
Package 9: VCR Gland (Female nut)
ORDERING INFORMATION
Honeywell • Sensing and Control
7
Pressure Sensors
Low-Cost, Stainless Steel, Isolated Sensors
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as
being free of defective materials and faulty
workmanship. Contact your local sales office for
warranty information. If warranted goods are
returned to Honeywell during the period of coverage,
Honeywell will repair or replace without charge those
items it finds defective. The foregoing is Buyer’s
sole remedy and is in lieu of all other warranties,
expressed or implied, including those of
merchantability and fitness for a particular
purpose.
Specifications may change without notice. The
information we supply is believed to be accurate and
reliable as of this printing. However, we assume no
responsibility for its use.
Sensing and Control
www.honeywell.com/sensing
Honeywell
11 West Spring Street
Freeport, Illinois 61032
008132-1-EN IL50 GLO 1004 Printed in USA
Copyright 2004 Honeywell International Inc. All Rights Reserved.
19 mm Series
While we provide application assistance personally,
through our literature and the Honeywell web site, it
is up to the customer to determine the suitability of
the product in the application.
For application assistance, current specifications, or
name of the nearest Authorized Distributor, contact a
nearby sales office. Or call:
1-800-537-6945 USA/Canada
1-815-235-6847 International
FAX
1-815-235-6545 USA
INTERNET
www.honeywell.com/sensing
[email protected]