1.Construction
1.1 Dimension and materials
Type : B3601D
1.2. Circuit construction, measurement circuit
2.Characteristics
Standard atmospheric conditions
Unless otherwise specified , the standard rang of atmospheric conditions for making
measurements and tests is as follows;
Ambient temperature : 15℃ to 35℃
Relative humidity
: 25% to 85%
Air pressure
: 86kPa to 106kPa
1
Operating temperature rang
Operating temperature rang is the rang of ambient temperatures in which the filter
can be
operated continuously. -10℃ ~ +60℃
Storage temperature rang
Storage temperature rang is the rang of ambient temperatures at which the filter can
be stored without damage.
Conditions are as specified elsewhere in these specifications. -40℃ ~ +70℃
Reference temperature
+25℃
2.1 Maximum Rating
DC voltage
VDC
12
V
AC voltage
Vpp
10
V
2.2 Electrical Characteristics
Source impedance
Zs=50Ω
Load impedance
ZL=2kΩ//3pF
Item
Freq
min
Center frequency
Fo
Insertion attenuation
36.00MHz
19.0
Reference level
B1.5dB
B3dB
Pass bandwidth
B15dB
B30dB
31.65MHz
7.0
40.35MHz
7.0
Relative attenuation
31.30MHz
22.0
40.70MHz
22.0
25.00~31.00MHz
32.0
Sidelobe
41.00~45.00MHz
30.0
Temperature coefficient
Between any terminals
Between any terminals
TA=25℃
typ
36.00
max
-
MHz
21.0
23.0
dB
7.8
8.1
8.9
9.4
10.0
10.0
29.0
29.0
40.0
38.0
-72
-
MHz
MHz
MHz
MHz
dB
dB
dB
dB
dB
dB
ppm/k
2.3 Environmental Performance Characteristics
Item Test condition
Allowable change of absolute
Level at center frequency(dB)
High temperature test
< 1.0
70℃ 1000H
Low temperature test
< 1.0
-40℃ 1000H
Humidity test
< 1.0
40℃ 90-95% 1000H
Thermal shock
< 1.0
2
-20℃==25℃==80℃ 20 cycle
30M
10M
30M
Solder temperature test
Sold temp.260℃ for 10 sec.
Soldering
Immerse the pins melt solder
at 260℃+5/-0℃ for 5 sec.
2.4 Mechanical Test
Item
Test condition
Vibration test
600-3300rpm amplitude 1.5mm
3 directions 2 H each
Drop test
On maple plate from 1 m high 3 times
Lead pull test
Pull with 1 kg force for 30 seconds
Lead bend test
90o bending with 500g weigh 2 times
2.5 Voltage Discharge Test
Item
Test condition
Surge test
Between any two electrode
< 1.0
More then 95% of total
area of the pins should
be covered with solder
Allowable change of absolute
Level at center frequency(dB)
<1.0
<1.0
<1.0
<1.0
Allowable change of absolute
Level at center frequency(dB)
<1.0
3
2.6 Frequency response: