HITRON HES12-050240-3

H HiTRON
AC/DC EXTERNAL WALLMOUNT & DESKTOP ADAPTER
UNIVERSAL OR USA INPUT SINGLE OUTPUT 12 WATTS
SWITCHING POWER SUPPLIES HES12 & HES12B SERIES
FEATURES:
LOW COST WALLMOUNT ADAPTER
DIVERSE AC PLUGS AVAILABLE
MEET DIVERSE SAFETY STANDARDS
EMI MEET EN 55022 OR FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: HES12 typ. 90-264Vac, rating 100-240Vac.
HES12B typ. 90-132Vac, rating 120Vac.
Input Connector:
HES12: WM1 (U.S.2-blade)/WM3 (Euro-stecker)/
DT8(IEC320-2P).
HES12B: WM1 (U.S.2-blade).
Input Frequency: 47-63Hz.
Inrush Current:
HES12: 28A @ 230Vac typical by adding thermister.
HES12B: 22.5A @ 115Vac typical.
Input Current: HES12 0.15A @ 230Vac typical.
HES12B 0.24A @ 115Vac typical.
Dielectric Withstand: Meet IEC60950.
EMI: Meet EN 55022 or FCC Class B.
Hold-up Time: 13.2mS@115Vac/42.0mS@230Vac.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 12 Watts typical.
Output Connector: Optional.
Line Regulation: 0.1% typical.
Load Regulation: ±2-3% typical.
Noise & Ripple: 1.0% typical peak to peak.
OVP: Built-in. By Zener diode clamping.
Adjustability: Factory set.
Overload Protection (OLP):
Fully protected against output overload or short circuit.
OLP set at about 120-150% max. load.
Consult the factory for special OLP setting
GENERAL SPECIFICATION
Efficiency: 80.5% typical.
Switching Frequency: 56-76K Hz.@ full load typical.
Circuit Topology: Free-running flyback circuit.
Transient Response: Output voltage returns typical 1mS
following a 25% load change.
Safety Standard: UL1950/EN60950 Class II.
Power Density: 2.3 Watts / Cubic inch.
Operating Temperature: 0 to +40°C with no derating.
Storage Temperature: -20 to +85°C.
Temperature Coefficient: 0.04% /°C typical.
Cooling: Free air convection.
Construction: Impact resistant thermo-plastic
enclosure case.
Wallmount or Desktop format.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 230Vac or 120Vac in percentage to indicate the change in output voltage as the load is varied from half load to full load (±%).
(3) The exact obtainable load regulation depends upon the output cord selected and load current. Upper data are for 6 ft. (2 m) cord AWG#18 wires.
For the details of safety approval, please consult the factory.
Due to requests in market and advances in technology, specifications subject to change without notice.
-13-
MODEL NO. DESCRIPTION: HES12 or B - XXX YYY – S
INPUT AC PLUG: HES12: [1]WM1, [3]WM3, [8]DT8
HES12B: WM1
OUTPUT CURRENT
OUTPUT VOLTAGE
SERIES NAME (HiTRON External Switcher): About 12W
OUTPUT VOLTAGE/CURRENT RATINGS CHART
SINGLE OUTPUT
MODEL NO.
HES12-033240-1,3,8
HES12B-033240
HES12-050240-1,3,8
HES12B-050240
HES12-060200-1,3,8
HES12B-060200
HES12-065180-1,3,8
HES12B-065180
HES12-075160-1,3,8
HES12B-075160
HES12-090130-1,3,8
HES12B-090130
HES12-120100-1,3,8
HES12B-120100
HES12-150080-1,3,8
HES12B-150080
HES12-240050-1,3,8
HES12B-240050
HES12-480025-1,3,8
HES12B-480025
AC INPUT
90-264Vac
90-132Vac
90-264Vac
90-132Vac
90-264Vac
90-132Vac
90-264Vac
90-132Vac
90-264Vac
90-132Vac
90-264Vac
90-132Vac
90-264Vac
90-132Vac
90-264Vac
90-132Vac
90-264Vac
90-132Vac
90-264Vac
90-132Vac
AC PLUG
WM1/WM3/DT8
WM1
WM1/WM3/DT8
WM1
WM1/WM3/DT8
WM1
WM1/WM3/DT8
WM1
WM1/WM3/DT8
WM1
WM1/WM3/DT8
WM1
WM1/WM3/DT8
WM1
WM1/WM3/DT8
WM1
WM1/WM3/DT8
WM1
WM1/WM3/DT8
WM1
O/P VOLTAGE
3.3V
3.3V
5.0V
5.0V
6.0V
6.0V
6.5V
6.5V
7.5V
7.5V
9.0V
9.0V
12.0V
12.0V
15.0V
15.0V
24.0V
24.0V
48.0V
48.0V
MECHANICAL DIMENSIONS: MM [INCHES]
-14-
O/P CURRENT
2.40A
2.40A
2.40A
2.40A
2.00A
2.00A
1.80A
1.80A
1.60A
1.60A
1.30A
1.30A
1.00A
1.00A
0.80A
0.80A
0.50A
0.50A
0.25A
0.25A
FORMAT
Wallmount/Desktop
Wallmount
Wallmount/Desktop
Wallmount
Wallmount/Desktop
Wallmount
Wallmount/Desktop
Wallmount
Wallmount/Desktop
Wallmount
Wallmount/Desktop
Wallmount
Wallmount/Desktop
Wallmount
Wallmount/Desktop
Wallmount
Wallmount/Desktop
Wallmount
Wallmount/Desktop
Wallmount
WEIGHT: 113g (4.0 Oz.)