IRF HFA60MC60C

PD -2.463 rev. B 03/99
HFA60MC60C
HEXFRED
Ultrafast, Soft Recovery Diode
TM
Features
(ISOLATED BASE)
• Reduced RFI and EMI
• Reduced Snubbing
• Extensive Characterization of
Recovery Parameters
1
ANODE
1
2
COMMON
CATHODE
3
ANODE
2
V R = 600V
V F(typ.)ƒ = 1.1V
IF(AV) = 60A
Qrr (typ.) = 200nC
IRRM(typ.) = 6A
trr(typ.) = 30ns
di(rec)M/dt (typ.)ƒ = 170A/µs
Description
HEXFRED diodes are optimized to reduce losses and EMI/RFI in high frequency
power conditioning systems. An extensive characterization of the recovery
behavior for different values of current, temperature and di/dt simplifies the
calculations of losses in the operating conditions. The softness of the recovery
eliminates the need for a snubber in most applications. These devices are
ideally suited for power converters, motors drives and other applications where
switching losses are significant portion of the total losses.
TM
TO-249AA
Absolute Maximum Ratings (per Leg)
Parameter
VR
IF @ TC = 25°C
IF @ TC = 100°C
IFSM
EAS
PD @ TC = 25°C
PD @ TC = 100°C
TJ
TSTG
Cathode-to-Anode Voltage
Continuous Forward Current
Continuous Forward Current
Single Pulse Forward Current 
Non-Repetitive Avalanche Energy ‚
Maximum Power Dissipation
Maximum Power Dissipation
Operating Junction and
Storage Temperature Range
Soldering Temperature, for 10 sec.
Max.
Units
600
50
24
200
220
125
50
V
A
µJ
W
-55 to +150
°C
300 (0.063 in. (1.6mm) from case)
Thermal - Mechanical Characteristics
Parameter
RθJC
RθCS
Wt
Junction-to-Case, Single Leg Conducting
Junction-to-Case, Both Legs Conducting
Case-to-Sink, Flat, Greased Surface
Weight
Mounting Torque
Min.
Typ.
Max.
––––
––––
––––
––––
––––
––––
0.10
58 (2.0)
1.0
0.50
––––
––––
35 (4.0)
––––
50 (5.7)
Units
°C/W
K/W
g (oz)
lbf•in
(N•m)
Note:  Limited by junction temperature
‚ L = 100µH, duty cycle limited by max TJ
ƒ 125°C
1
HFA60MC60C
PD-2.463 rev. B 03/99
Electrical Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
Parameter
V BR
V FM
Min. Typ. Max. Units
Cathode Anode Breakdown Voltage
Max Forward Voltage
IRM
Max Reverse Leakage Current
CT
LS
Junction Capacitance
Series Inductance
600
–––
–––
–––
–––
–––
–––
–––
––– –––
1.3 1.5
1.4 1.7
1.1 1.3
2.0
10
0.50 2.0
68 100
8.0 –––
V
V
µA
mA
pF
nH
Test Conditions
I R = 100µA
I F = 30A
See Fig. 1
I F = 60A
I F = 30A, TJ = 125°C
VR = VR Rated
See Fig. 2
TJ = 125°C, VR = 480V
See Fig. 3
VR = 200V
From terminal hole to terminal hole
Dynamic Recovery Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
Parameter
trr
trr1
trr2
IRRM1
IRRM2
Qrr1
Qrr2
di(rec)M/dt1
di(rec)M/dt2
Min. Typ. Max. Units
Reverse Recovery Time
–––
–––
–––
–––
–––
–––
–––
–––
–––
Peak Recovery Current
Reverse Recovery Charge
Peak Rate of Fall of Recovery Current
During tb
50.80 (2.000)
REF.
6.60 (0.260)
6.10 (0.240)
4.95 (0.195)
DIA.
4.45 (0.175)
(7 PLCS.)
25.65 (1.010)
25.15 (0.990)
12.70 (0.500)
REF.
1
2
3
1.14 (0.045)
0.76 (0.030)
8.05 (0.317)
7.80 (0.307)
8.64 (0.340)
REF. (3 PLCS.)
Test Conditions
30 –––
IF = 1.0A, di f /dt = 200A/µs, VR = 30V
67 100
ns TJ = 25°C
See
112 170
TJ = 125°C Fig. 5
IF = 50A
6.0 11
TJ = 25°C
See
A
9.0 16
TJ = 125°C Fig. 6
VR = 200V
200 550
TJ = 25°C
See
nC
500 1400
TJ = 125°C Fig. 7
dif /dt = 200A/µs
250 –––
TJ = 25°C
See
A/µs
170 –––
TJ = 125°C Fig. 8
LEAD ASSIGNMENTS
1 - ANODE
2 - CATHODE
3 - ANODE
BASE (ISOLATED)
13.21 (0.520)
12.70 (0.500)
11.43 (0.450)
REF.
22.86 (0.900)
REF.
Conforms to JEDEC Outline TO - 249AA
Dimensions in millimeters and inches
1.14 (0.045)
0.89 (0.035)
6.60 (0.260)
6.10 (0.240)
2
38.35 (1.510)
37.85 (1.490)
1.27 (0.050)
REF.
61.21 (2.410)
60.71 (2.390)
10.16 (0.400)
8.38 (0.330)
3.30 (0.130)
3.05 (0.120)
HFA60MC60C
PD-2.463 rev. B 03/99
10000
Reverse Current - I R (µA)
100
TJ = 150°C
1000
100
TJ = 125°C
10
1
0.1
TJ = 25°C
0.01
T = 150°C
0
J
200
400
600
Reverse Voltage - VR (V)
TJ = 125°C
Fig. 2 - Typical Reverse Current vs. Reverse
Voltage, (per Leg)
TJ = 25°C
10
Junction Capacitance - C T (pF)
Instantaneous Forward Current - I F (A)
1000
1000
A
TJ = 25°C
100
1
0.4
0.8
1.2
1.6
2.0
2.4
2.8
3.2
Forward Voltage Drop - V FM (V)
Fig. 1 - Maximum Forward Voltage Drop
vs. Instantaneous Forward Current,
(per Leg)
10
1
10
100
1000
Reverse Voltage - VR (V)
Fig. 3 - Typical Junction Capacitance vs.
Reverse Voltage, (per Leg)
Thermal Impedance - Z thJC (K/W )
10
1
0.1
D = 0.50
D = 0.33
D = 0.25
D = 0.17
D = 0.08
PDM
t
1
t2
Notes:
1. Duty factor D = t1 / t 2
0.01
0.001
0.00001
Single Pulse
(Thermal Resistance)
0.0001
0.001
2. Peak TJ = PDM x Z thJC + TC
0.01
0.1
1
10
100
t 1 , Rectangular Pulse Duration (Seconds)
Fig. 4 - Maximum Thermal Impedance ZthJC Characteristics, (per Leg)
3
HFA60MC60C
PD-2.463 rev. B 03/99
40
150
VR = 200V
TJ = 125°C
TJ = 25°C
VR = 200V
TJ = 125°C
TJ = 25°C
30
t rr - (ns)
t rr - (ns)
120
I F = 70A
I F = 30A
90
I F = 15A
I F = 70A
20
I F = 30A
I F = 15A
10
60
30
100
di f /dt - (A/µs)
0
100
1000
Fig. 5 - Typical Reverse Recovery vs. di f/dt,
(per Leg)
di f /dt - (A/µs)
1000
Fig. 6 - Typical Recovery Current vs. dif/dt,
(per Leg)
10000
1600
VR = 200V
TJ = 125°C
TJ = 25°C
VR = 200V
TJ = 125°C
TJ = 25°C
di(rec)M/dt - (A/µs)
1200
Q RR - (nC)
IF = 70A
I F = 30A
800
IF = 15A
I F = 15A
1000
I F = 30A
I F = 70A
100
400
0
100
di f /dt - (A/µs)
1000
Fig. 7 - Typical Stored Charge vs. di f/dt,
(per Leg)
4
10
100
di f /dt - (A/µs)
Fig. 8 - Typical di (rec)M/dt vs. dif/dt,
(per Leg)
1000
HFA60MC60C
PD-2.463 rev. B 03/99
3
t rr
IF
tb
ta
0
REVERSE RECOVERY CIRCUIT
VR = 200V
Q rr
2
I RRM
4
0.5 I RRM
di(rec)M/dt
5
0.01 Ω
0.75 I RRM
L = 70µH
1
D.U.T.
D
dif/dt
ADJUST G
di f /dt
4. Qrr - Area under curve defined by trr
and IRRM
trr X IRRM
Qrr =
2
1. dif /dt - Rate of change of current
through zero crossing
IRFP250
2. IRRM - Peak reverse recovery current
3. trr - Reverse recovery time measured
from zero crossing point of negative
going I F to point where a line passing
through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current
S
Fig. 9 - Reverse Recovery Parameter Test
Circuit
L = 100µH
5. di(rec)M/dt - Peak rate of change of
current during tb portion of trr
Fig. 10 - Reverse Recovery Waveform and
Definitions
I L(PK)
HIGH-SPEED
SWITCH
DUT
Rg = 25 ohm
CURRENT
MONITOR
FREE-WHEEL
DIODE
+
DECAY
TIME
Vd = 50V
V (AVAL)
V R(RATED)
Fig. 11 - Avalanche Test Circuit and Waveforms
WORLD HEADQUARTERS:
EUROPEAN HEADQUARTERS:
IR CANADA:
IR GERMANY:
IR ITALY:
IR FAR EAST:
IR SOUTHEAST ASIA:
IR TAIWAN:
http://www.irf.com
233 Kansas St., El Segundo, California 90245 U.S.A. Tel: (310) 322 3331. Fax: (310) 322 3332.
Hurst Green, Oxted, Surrey RH8 9BB, U.K. Tel: ++ 44 1883 732020. Fax: ++ 44 1883 733408.
15 Lincoln Court, Brampton, Markham, Ontario L6T3Z2. Tel: (905) 453 2200. Fax: (905) 475 8801.
Saalburgstrasse 157, 61350 Bad Homburg. Tel: ++ 49 6172 96590. Fax: ++ 49 6172 965933.
Via Liguria 49, 10071 Borgaro, Torino. Tel: ++ 39 11 4510111. Fax: ++ 39 11 4510220.
K&H Bldg., 2F, 30-4 Nishi-Ikebukuro 3-Chome, Toshima-Ku, Tokyo, Japan 171. Tel: 81 3 3983 0086.
1 Kim Seng Promenade, Great World City West Tower,13-11, Singapore 237994. Tel: ++ 65 838 4630.
16 Fl. Suite D.207, Sec. 2, Tun Haw South Road, Taipei, 10673, Taiwan. Tel: 886 2 2377 9936.
Fax-On-Demand: +44 1883 733420
Data and specifications subject to change without notice.
5