T-13/4 (5 mm) Low Profile LED Lamps HLMP-3351 HLMP-3366 HLMP-3451 HLMP-3466 HLMP-3554 HLMP-3568 Technical Data Features • High Intensity • Low Profile: 5.8 mm (0.23 in.) Nominal • T-13/4 Diameter Package • Diffused and Non-diffused Types • General Purpose Leads • IC Compatible/Low Current Requirements • Reliable and Rugged Description The HLMP-335x/-336x Series are Gallium Arsenide Phosphide on Gallium Phosphide High Efficiency Red Light Emitting Diodes. The HLMP-345x/-346x Series are Gallium Arsenide Phosphide on Gallium Phosphide Yellow Light Emitting Diodes. The HLMP-355x/-356x Series are Gallium Phosphide Green Light Emitting Diodes. The Low Profile T-1 3/4 package provides space savings and is excellent for backlighting applications. Package Dimensions 5.34 (0.210) 4.83 (0.190) 2 Selection Guide Color Package Description 2θ1/2[1] T-1 3/4 Tinted, diffused 50 T-1 3/4 Tinted, non-diffused 45 T-1 3/4 Tinted, diffused 50 T-1 3/4 Tinted, non-diffused 45 T-1 3/4 Tinted, diffused 50 T-1 3/4 Tinted, non-diffused 40 Red Yellow Green Part Number HLMP3351 3351-D00xx 3351-F00xx 3366 3366-H00xx 3451 3451-D00xx 3451-EFBxx 3451-F00xx 3466 3466-F00xx 3554 3554-E00xx 3568 3568-F00xx Part Numbering System HLMP - 3 x xx - x x x xx Mechanical Option 00: Bulk 01: Tape & Reel, Crimped Leads 02: Tape & Reel, Straight Leads R1: Tape & Reel, Counterclockwise Color Bin Options 0: Full Color Bin Distribution B: Color bin 2 & 3 only Maximum Iv Bin Options 0: Open (No. max. limit) Others: Please refer to the Iv Bin Table Minimum Iv Bin Options Please refer to the Iv Bin Table Lens Options 5x: Tinted, Diffused 6x: Tinted, Nondiffused Color Options 3: GaP HER 4: GaP Yellow 5: GaP Green Package Options 3: T-1 3/4 (5 mm) Luminous Intensity Iv (mcd) Min. 5.4 2.1 5.4 13.8 13.8 3.6 3.6 5.7 9.2 9.2 9.2 6.7 6.7 10.6 10.6 Max. 18.4 - 3 High Efficiency Red HLMP-335x/-336x Series Electrical Specifications at TA = 25°C Symbol Device HLMP- Description 2θ1/2 Including Angle Between Half Luminous Intensity Points λPEAK λd ∆λ1/2 τs C Min. 3366 Typ. Max. Units 50 50 45 45 Deg. Peak Wavelength 635 nm Measurement at Peak (Figure 1) Dominant Wavelength 626 nm Note 2 Spectral Line Halfwidth 40 nm Speed of Response 90 ns Capacitance 11 pF Thermal Resistance 260 °C/W VF Forward Voltage 1.9 VR Reverse Breakdown Voltage ηV Luminous Efficacy RθJ-PIN Test Conditions 5.0 145 2.4 Note 1 (Figure 11) VF = 0; f = 1 MHz Junction to Cathode Lead V IF = 10 mA (Figure 7) V IR = 100 µA lm/W Note 3 Notes: 1. θ1 /2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity. 2. Dominant wavelength, λd, is derived from the CIE chromaticity diagram and represents the single wavelength which defines the color of the device. 3. Radiant Intensity, Ie, in watts/steradian may be found from the equation Ie = Iv/ηv, where Iv is the luminous intensity in candelas and ηv is the luminous efficacy in lumens/watt. Figure 7. Forward Current vs. Forward Voltage. Figure 8. Relative Luminous Intensity vs. Forward Current. Figure 9. Relative Efficiency (Luminous Intensity per Unit Current) vs. Peak Current. 4 Figure 10. Maximum Tolerable Peak Current vs. Pulse Duration. (IDC MAX as per MAX Ratings). Figure 11. Relative Luminous Intensity vs. Angular Displacement. Yellow HLMP-345x/-346x Series Electrical Specifications at TA = 25°C Symbol Description 2θ1/2 Including Angle Between Half Luminous Intensity Points λPEAK Device HLMP- Min. Max. Units Test Conditions 50 50 45 45 Deg. Peak Wavelength 583 nm Measurement at Peak (Figure 1) λd Dominant Wavelength 585 nm Note 2 ∆λ 1/2 Spectral Line Halfwidth 36 nm τs Speed of Response 90 ns C Capacitance 15 pF Thermal Resistance 260 °C/W VF Forward Voltage 2.0 VR Reverse Breakdown Voltage ηV Luminous Efficacy RθJ-PIN 3466 Typ. 5.0 500 2.4 Note 1 (Figure 16) VF = 0; f = 1 MHz Junction to Cathode Lead V IF = 10 mA (Figure 12) V IR = 100 µA lm/W Note 3 Notes: 1. θ1 /2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity. 2. Dominant wavelength, λd, is derived from the CIE chromaticity diagram and represents the single wavelength which defines the color of the device. 3. Radiant Intensity, Ie, in watts/steradian may be found from the equation Ie = Iv/ηv, where Iv is the luminous intensity in candelas and ηv is the luminous efficacy in lumens/watt. 5 I F – FORWARD CURRENT – mA 60 50 40 30 20 10 0 1.0 1.5 2.0 2.5 3.0 3.5 4.0 V F – FORWARD VOLTAGE – V Figure 12. Forward Current vs. Forward Voltage. Figure 15. Maximum Tolerable Peak Current vs. Pulse Duration. (IDC MAX as per MAX Ratings). Figure 13. Relative Luminous Intensity vs. Forward Current. Figure 14. Relative Efficiency (Luminous Intensity per Unit Current) vs. Peak Current. Figure 16. Relative Luminous Intensity vs. Angular Displacement. 6 Green HLMP-355x/-356x Series Electrical Specifications at TA = 25°C Symbol Description Device HLMP- 2θ1/2 Including Angle Between Half Luminous Intensity Points 3554 3568 λPEAK Min. Typ. Max. Units Test Conditions 50 40 Deg. Peak Wavelength 565 nm Measurement at Peak (Figure 1) λd Dominant Wavelength 569 nm Note 2 ∆λ 1/2 Spectral Line Halfwidth 28 nm Speed of Response 500 ns τs C Capacitance 18 pF Thermal Resistance 260 °C/W VF Forward Voltage 2.1 VR Reverse Breakdown Voltage ηV Luminous Efficacy RθJ-PIN 5.0 595 2.7 Note 1 (Figure 21) VF = 0; f = 1 MHz Junction to Cathode Lead V IF = 10 mA (Figure 17) V IR = 100 µA lm/W Note 3 Notes: 1. θ1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity. 2. Dominant wavelength, λd, is derived from the CIE chromaticity diagram and represents the single wavelength which defines the color of the device. 3. Radiant Intensity, Ie, in watts/steradian may be found from the equation Ie = Iv/ηv, where Iv is the luminous intensity in candelas and ηv is the luminous efficacy in lumens/watt. Figure 17. Forward Current vs. Forward Voltage. Figure 18. Relative Luminous Intensity vs. Forward Current. Figure 19. Relative Efficiency (Luminous Intensity per Unit Current) vs. Peak Current. 7 Figure 20. Maximum Tolerable Peak Current vs. Pulse Duration. (IDC MAX as per MAX Ratings). Figure 21. Relative Luminous Intensity vs. Angular Displacement. Intensity Bin Limits Color Red Bin D E F G H I J K L M N O P Q R S T U V W X Y Z Intensity Range (mcd) Min. Max. 2.4 3.8 3.8 6.1 6.1 9.7 9.7 15.5 15.5 24.8 24.8 39.6 39.6 63.4 63.4 101.5 101.5 162.4 162.4 234.6 234.6 340.0 340.0 540.0 540.0 850.0 850.0 1200.0 1200.0 1700.0 1700.0 2400.0 2400.0 3400.0 3400.0 4900.0 4900.0 7100.0 7100.0 10200.0 10200.0 14800.0 14800.0 21400.0 21400.0 30900.0 Maximum tolerance for each bin limit is ± 18%. Color Yellow Bin D E F G H I J K L M N O P Q R S T U V W Intensity Range (mcd) Min. Max. 4.0 6.5 6.5 10.3 10.3 16.6 16.6 26.5 26.5 42.3 42.3 67.7 67.7 108.2 108.2 173.2 173.2 250.0 250.0 360.0 360.0 510.0 510.0 800.0 800.0 1250.0 1250.0 1800.0 1800.0 2900.0 2900.0 4700.0 4700.0 7200.0 7200.0 11700.0 11700.0 18000.0 18000.0 27000.0 Intensity Bin Limits, continued Color Green Bin E F G H I J K L M N O P Q R S T U V W Intensity Range (mcd) Min. Max. 7.6 12.0 12.0 19.1 19.1 30.7 30.7 49.1 49.1 78.5 78.5 125.7 125.7 201.1 201.1 289.0 289.0 417.0 417.0 680.0 680.0 1100.0 1100.0 1800.0 1800.0 2700.0 2700.0 4300.0 4300.0 6800.0 6800.0 10800.0 10800.0 16000.0 16000.0 25000.0 25000.0 40000.0 Color Categories Lambda (nm) Color Green Yellow Cat # Min. Max. 6 561.5 564.5 5 564.5 567.5 4 567.5 570.5 3 570.5 573.5 2 573.5 576.5 1 582.0 584.5 3 584.5 587.0 2 587.0 589.5 4 589.5 592.0 5 592.0 593.0 Maximum tolerance for each bin limit is ± 0.5 nm. Maximum tolerance for each bin limit is ± 18%. Mechanical Option Matrix Mechanical Option Code Definition 00 Bulk Packaging, minimum increment 500 pcs/bag 01 Tape & Reel, crimped leads, minimum increment 1300 pcs/bag 02 Tape & Reel, straight leads, minimum increment 1300 pcs/bag R1 Tape & Reel, crimped leads, reeled counterclockwise, anode leaves first Note: All categories are established for classification of products. Products may not be available in all categories. Please contact your local Agilent representative for further clarification/information. www.semiconductor.agilent.com Data subject to change. Copyright © 2001 Agilent Technologies, Inc. July 16, 2001 Obsoletes 5988-0365EN 5988-3025EN