HS-80C86RH Radiation Hardened 16-Bit CMOS Microprocessor September 1995 Features Description • Radiation Hardened The Intersil HS-80C86RH high performance radiation hardened 16-bit CMOS CPU is manufactured using a hardened field, self aligned silicon gate CMOS process. Two modes of operation, MINimum for small systems and MAXimum for larger applications such as multiprocessing, allow user configuration to achieve the highest performance level. Industry standard operation allows use of existing NMOS 8086 hardware and software designs. - Latch Up Free EPl-CMOS - Total Dose >100K RAD (Si) - Transient Upset >108 RAD (Si)/s • Low Power Operation - ICCSB = 500µA (Max) - ICCOP = 12mA/MHz (Max) • Pin Compatible with NMOS 8086 and Intersil 80C86 • Completely Static Design DC to 5MHz • 1MB Direct Memory Addressing Capability • 24 Operand Addressing Modes • Bit, Byte, Word, and Block Move Operations • 8-Bit and 16-Bit Signed/Unsigned Arithmetic - Binary or Decimal - Multiply and Divide • Bus-hold Circuitry Eliminates Pull-up Resistors for CMOS Designs • Hardened Field, Self-Aligned, Junction-Isolated CMOS Process • Single 5V Power Supply • Military Temperature Range -35oC to +125oC • Minimum LET for Single Event Upset -6MEV/mg/cm2 (Typ) Ordering Information PART NUMBER TEMPERATURE RANGE SCREENING LEVEL PACKAGE HS1-80C86RH-8 -35o C to +125o C Intersil Class B Equivalent 40 Lead Braze Seal DIP HS1-80C86RH-Q -35o C to +125o C Intersil Class S Equivalent 40 Lead Braze Seal DIP HS9-80C86RH-8 -35o C to +125o C Intersil Class B Equivalent 42 Lead Braze Seal Flatpack HS9-80C86RH-Q -35o C to +125o C Intersil Class S Equivalent 42 Lead Braze Seal Flatpack HS9-80C86RH-SAMPLE 25o C Sample 42 Lead Braze Seal Flatpack HS1-80C86RH-SAMPLE 25o C Sample 40 Lead Braze Seal DIP HS9-80C86RH-PROTO -35o C to +125o C Prototype 42 Lead Braze Seal Flatpack HS1-80C86RH-PROTO -35o C to +125o C Prototype 40 Lead Braze Seal DIP CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures. http://www.intersil.com or 407-727-9207 | Copyright © Intersil Corporation 1999 856 Spec Number File Number 518055 3035.1 HS-80C86RH Pinouts HS-80C86RH 40 LEAD CERAMIC DUAL-IN-LINE METAL SEAL PACKAGE (SBDIP) MIL-STD-1835, CDIP2-T40 TOP VIEW GND 1 MAX 40 VDD MIN AD14 2 39 AD15 AD13 3 38 AD16/S3 AD12 4 37 A17/S4 AD11 5 36 A18/S5 AD10 6 35 A19/S6 AD9 7 34 BHE/S7 AD8 8 33 MN/MX AD7 9 32 RD AD6 10 31 RQ/GT0 (HOLD) AD5 11 30 RQ/GT1 (HLDA) AD4 12 29 LOCK (WR) AD3 13 28 S2 (M/IO) AD2 14 27 S1 (DT/R) AD1 15 26 S0 (DEN) AD0 16 25 QS0 (ALE) NMI 17 24 QS1 (INTA) INTR 18 23 TEST CLK 19 22 READY GND 20 21 RESET HS-80C86RH 42 LEAD CERAMIC METAL SEAL FLATPACK PACKAGE (FLATPACK) INTERSIL OUTLINE K42.A TOP VIEW GND AD14 AD13 AD12 AD11 AD10 AD9 AD8 AD7 AD6 AD5 AD4 AD3 AD2 AD1 AD0 NC NMI INTR CLK GND 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 MAX VDD AD15 NC A16/S3 A17/S4 A18/S5 A19/S6 BHE/S7 MN/MX RD MIN RQ/GT0 RQ/GT1 LOCK S2 S1 (HOLD) S0 QS0 QS1 TEST READY RESET (HLDA) (WR) (M/IO) (DT/R) (DEN) (ALE) (INTA) Spec Number 857 518055 HS-80C86RH Functional Diagram BUS INTERFACE UNIT EXECUTION UNIT REGISTER FILE RELOCATION REGISTER FILE DATA POINTER AND INDEX REGS (8 WORDS) SEGMENT REGISTERS AND INSTRUCTION POINTER (5 WORDS) 16-BIT ALU FLAGS BUS INTERFACE UNIT 4 BHE/S7 A19/S6 A16/S3 16 AD15-AD0 3 INTA, RD, WR 4 DT/R, DEN, ALE, M/IO 6-BYTE INSTRUCTION QUEUE TEST INTR NMI RQ/GT0, 1 LOCK CONTROL AND TIMING 2 HOLD HLDA CLK RESET READY MN/MX 2 QS0, QS1 3 S2, S1, S0 3 GND VDD MEMORY INTERFACE C-BUS INSTRUCTION STREAM BYTE QUEUE B+BUS ES CS BUS INTERFACE UNIT SS DS IP EXECUTION UNIT CONTROL SYSTEM A-BUS AH BH AL BL CL CH EXECUTION UNIT ARITHMETIC/ LOGIC UNIT DL DH SP BP SI FLAGS DI Spec Number 858 518055 HS-80C86RH Pin Description SYMBOL PIN NUMBER TYPE DESCRIPTION The following pin function descriptions are for HS-80C86RH systems in either minimum or maximum mode. The “Local Bus” in these descriptions is the direct multiplexed bus interface connection to the HS-80C86RH (without regard to additional bus buffers). AD15-AD0 2-16, 39 I/O ADDRESS DATA BUS: These lines constitute the time multiplexed memory/IO address (T1) and data (T2, T3, TW, T4) bus. AO is analogous to BHE for the lower byte of the data bus, pins D7-D0. It is LOW during T1 when a byte is to be transferred on the lower portion of the bus in memory or I/O operations. Eight-bit oriented devices tied to the lower half would normally use AD0 to condition chip select functions (See BHE). These lines are active HIGH and are held at high impedance to the last valid logic level during interrupt acknowledge and local bus “hold acknowledge” or “grant sequence”. A19/S6 A18/S5 A17/S4 A16/S3 35-38 O ADDRESS/STATUS: During T1, these are the four most significant address lines for memory operations. During I/O operations these lines are low. During memory and I/O operations, status information is available on these lines during T2, T3, TW, T4. S6 is always zero. The status of the interrupt enable FLAG bit (S5) is updated at the beginning of each CLK cycle. S4 and S3 are encoded. This information indicates which segment register is presently being used for data accessing. These lines are held at high impedance to the last valid logic level during local bus “hold acknowledge” or “grant sequence”. S4 S3 0 0 Extra Data 0 1 Stack 1 0 Code or None 1 1 Data BHE/S7 34 O BUS HIGH ENABLE/STATUS: During T1 the bus high enable signal (BHE) should be used to enable data onto the most significant half of the data bus, pins D15-D8. Eight bit oriented devices tied to the upper half of the bus would normally use BHE to condition chip select functions. BHE is LOW during T1 for read, write, and interrupt acknowledge cycles when a byte is to be transferred on the high portion of the bus. The S7 status information is available during T2, T3 and T4. The signal is active LOW, and is held at high impedance to the last valid logic level during interrupt acknowledge and local bus “hold acknowledge” or “grant sequence”; it is LOW during T1 for the first interrupt acknowledge cycle. BHE A0 0 0 Whole Word 0 1 Upper Byte from/to Odd Address 1 0 Lower Byte from/to Even Address 1 1 None RD 32 O READ: Read strobe indicates that the processor is performing a memory or I/O read cycle, depending on the state of the M/IO or S2 pin. This signal is used to read devices which reside on the HS-80C86RH local bus. RD is active LOW during T2, T3 and TW of any read cycle, and is guaranteed to remain HIGH in T2 until the 80C86 local bus has floated. This line is held at a high impedance logic one state during “hold acknowledge” or “grant sequence”. READY 22 I READY: is the acknowledgment from the addressed memory or I/O device that will complete the data transfer. The RDY signal from memory or I/O is synchronized by the HS-82C85RH Clock Generator to form READY. This signal is active HIGH. The HS-80C86RH READY input is not synchronized. Correct operation is not guaranteed if the Setup and Hold Times are not met. INTR 18 I INTERRUPT REQUEST: is a level triggered input which is sampled during the last clock cycle of each instruction to determine if the processor should enter into an interrupt acknowledge operation. If so, an interrupt service routine is called via an interrupt vector lookup table located in system memory. INTR is internally synchronized and can be internally masked by software resetting the interrupt enable bit. This signal is active HIGH. TEST 23 I TEST: input is examined by the “Wait” instruction. If the TEST input is LOW execution continues, otherwise the processor waits in an “Idle” state. This input is synchronized internally during each clock cycle on the leading edge of CLK. NMI 17 I NON-MASKABLE INTERRUPT: is an edge triggered input which causes a type 2 interrupt. An interrupt service routine is called via an interrupt vector lookup table located in system memory. NMI is not maskable internally by software. A transition from LOW to HIGH initiates the interrupt at the end of the current instruction. This input is internally synchronized. Spec Number 859 518055 HS-80C86RH Pin Description (Continued) SYMBOL PIN NUMBER TYPE DESCRIPTION RESET 21 I RESET: causes the processor to immediately terminate its present activity. The signal must change from LOW to HIGH and remain active HIGH for at least 4 CLK cycles. It restarts execution, as described in the Instruction Set description, when RESET returns LOW. RESET is internally synchronized. CLK 19 I CLOCK: provides the basic timing for the processor and bus controller. It is asymmetric with a 33% duty cycle to provide optimized internal timing. VDD 40 GND 1, 20 MN/MX 33 VDD: +5V power supply pin. A 0.1µF capacitor between pins 20 and 40 is recommended for decoupling. GND: Ground. Note: both must be connected. A 0.1µF capacitor between pins 1 and 20 is recommended for decoupling. I MINIMUM/MAXIMUM: Indicates what mode the processor is to operate in. The two modes are discussed in the following sections. The following pin function descriptions are for the HS-80C86RH system in maximum mode (i.e., MN/MX = GND). Only the pin functions which are unique to maximum mode are described below. S0, S1, S2 26-28 O STATUS: is active during T4, T1 and T2 and is returned to the passive state (1,1,1) during T3 or during TW when READY is HIGH. This status is used by the 82C88 Bus Controller to generate all memory and I/O access control signals. Any change by S2, S1, or S0 during T4 is used to indicate the beginning of a bus cycle, and the return to the passive state in T3 or TW is used to indicate the end of a bus cycle. These status lines are encoded. These signals are held at a high impedance logic one state during “grant sequence”. S2 S1 S0 0 0 0 Interrupt Acknowledge 0 0 1 Read I/O Port 0 1 0 Write I/O Port 0 1 1 Halt 1 0 0 Code Access 1 0 1 Read Memory 1 1 0 Write Memory 1 1 1 Passive RQ/GT0 RQ/GT1 31, 30 I/O REQUEST/GRANT: pins are used by other local bus masters to force the processor to release the local bus at the end of the processor’s current bus cycle. Each pin is bidirectional with RQ/GT0 having higher priority than RQ/GT1. RQ/GT has an internal pull-up bus hold device so it may be left unconnected. The request/grant sequence is as follows (see RQ/GT Sequence Timing.) 1. A pulse of 1 CLK wide from another local bus master indicates a local bus request (“hold”) to the HS-80C86RH (pulse 1). 2. During a T4 or T1 clock cycle, a pulse 1 CLK wide from the HS-80C86RH to the requesting master (pulse 2) indicates that the HS-80C86RH has allowed the local bus to float and that it will enter the “grant sequence” state at the next CLK. The CPU’s bus interface unit is disconnected logically from the local bus during “grant sequence”. 3. A pulse 1 CLK wide from the requesting master indicates to the HS-80C86RH (pulse 3) that the “hold” request is about to end and that the HS-80C86RH can reclaim the local bus at the next CLK. The CPU then enters T4 (or T1 if no bus cycles pending). Each Master-Master exchange of the local bus is a sequence of 3 pulses. There must be one idle CLK cycle after each bus exchange. Pulses are active low. If the request is made while the CPU is performing a memory cycle, it will release the local bus during T4 of the cycle when all the following conditions are met: 1. Request occurs on or before T2. 2. Current cycle is not the low byte of a word (on an odd address). 3. Current cycle is not the first acknowledge of an interrupt acknowledge sequence. 4. A locked instruction is not currently executing. If the local bus is idle when the request is made the two possible events will follow: 1. Local bus will be released during the next cycle. 2. A memory cycle will start within 3 CLKs. Now the four rules for a currently active memory cycle apply with condition number 1 already satisfied. Spec Number 860 518055 HS-80C86RH Pin Description (Continued) SYMBOL PIN NUMBER TYPE DESCRIPTION LOCK 29 O LOCK: output indicates that other system bus masters are not to gain control of the system bus while LOCK is active LOW. The LOCK signal is activated by the “LOCK” prefix instruction and remains active until the completion of the next instruction. This signal is active LOW, and is held at a HIGH impedance logic one state during “grant sequence”. In MAX mode, LOCK is automatically generated during T2 of the first INTA cycle and removed during T2 of the second INTA cycle. QS1, QS0 24, 25 O QUEUE STATUS: The queue status is valid during the CLK cycle after which the queue operation is performed. QS1 and QS2 provide status to allow external tracking of the internal HS-80C86RH instruction queue. Note that QS1, QS0 never become high impedance. QS1 QS0 0 0 No Operation 0 1 First Byte of Opcode from Queue 1 0 Empty the Queue 1 1 Subsequent Byte from Queue The following pin function descriptions are for the HS-80C86RH in minimum mode (i.e. MN/MX = VDD). Only the pin functions which are unique to minimum mode are described; all other pin functions are as described below. M/IO 28 O STATUS LINE: logically equivalent to S2 in the maximum mode. It is used to distinguish a memory access from an I/O access. M/IO becomes valid in the T4 preceding a bus cycle and remains valid until the final T4 of the cycle (M = HIGH, IO = LOW). M/IO is held to a high impedance logic zero during local bus “hold acknowledge”. WR 29 O WRITE: indicates that the processor is performing a write memory or write I/O cycle, depending on the state of the M/IO signal. WR is active for T2, T3 and TW of any write cycle. It is active LOW, and is held to high impedance logic one during local bus “hold acknowledge”. INTA 24 O INTERRUPT ACKNOWLEDGE: is used as a read strobe for interrupt acknowledge cycles. It is active LOW during T2, T3 and TW of each interrupt acknowledge cycle. Note that INTA is never floated. ALE 25 O ADDRESS LATCH ENABLE: is provided by the processor to latch the address into the 82C82 latch. It is a HIGH pulse active during clock LOW of Tl of any bus cycle. Note that ALE is never floated. DT/R 27 O DATA TRANSMIT/RECEIVE: is needed in a minimum system that desires to use a data bus transceiver. It is used to control the direction of data flow through the transceiver. Logically, DT/R is equivalent to S1 in maximum mode, and its timing is the same as for M/IO (T = HlGH, R = LOW). DT/R is held to a high impedance logic one during local bus “hold acknowledge”. DEN 26 O DATA ENABLE: provided as an output enable fora bus transceiver in a minimum system which uses the transceiver. DEN is active LOW during each memory and I/O access and for INTA cycles. For a read or INTA cycle it is active from the middle of T2 until the middle of T4, while for a write cycle it is active from the beginning of T2 until the middle of T4. DEN is held to a high impedance logic one during local bus “hold acknowledge”. HOLD HLDA 31 30 I O HOLD: indicates that another master is requesting a local bus “hold”. To be a acknowledged, HOLD must be active HIGH. The processor receiving the “hold” will issue a “hold acknowledge” (HLDA) in the middle of a T4 or T1 clock cycle. Simultaneously with the issuance of HLDA, the processor will float the local bus and control lines. After HOLD is detected as being LOW, the processor will lower HLDA, and when the processor needs to run another cycle, it will again drive the local bus and control lines. HOLD is not an asynchronous input. External synchronization should be provided if the system cannot otherwise guarantee the setup time. Spec Number 861 518055 Specifications HS-80C86RH Absolute Maximum Ratings Reliability Information Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +7.0V Input or Output Voltage Applied for all Grades . . . . . . . . . . . . . . . . . .VSS-0.3V to VDD+0.3V Storage Temperature Range . . . . . . . . . . . . . . . . . -65oC to +150oC Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +175oC Lead Temperature (Soldering 10s) . . . . . . . . . . . . . . . . . . . . +300oC Typical Derating Factor . . . . . . . . . . . 12mA/MHz Increase in IDDOP ESD Classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Class 1 Thermal Resistance θJA θJC SBDIP Package . . . . . . . . . . . . . . . . . . . . 40.0oC/W 8.6oC/W Ceramic Flatpack Package . . . . . . . . . . . 72.1oC/W 9.7oC/W Maximum Package Power Dissipation at +125oC Ambient SBDIP Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.25W Ceramic Flatpack Package . . . . . . . . . . . . . . . . . . . . . . . . . 0.69W If Device Power Exceeds Package Dissipation Capability, Provide Heat Sinking or Derate Linearly at the Following Rate SBDIP Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25.0mW/oC Ceramic Flatpack Package . . . . . . . . . . . . . . . . . . . . . 13.9mW/oC Gate Count . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9750 Gates CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Operating Conditions Operating Supply Voltage Range (VDD) . . . . . . . +4.75V to +5.25V Operating Temperature Range (TA) . . . . . . . . . . . . -35oC to +125oC Input Low Voltage (VIL) . . . . . . . . . . . . . . . . . . . . . . . . . 0V to +0.8V Input High Voltage (VIH) . . . . . . . . . . . . . . . . . . . . . . . . 3.5V to VDD Clock Input Low Voltage (VILC) . . . . . . . . . . . . . . . . . . 0.0V to 0.8V CLK and MN/MX Input High (VIHC) . . . . . . . . . . VDD - 0.8V to VDD TABLE 1. DC ELECTRICAL PERFORMANCE CHARACTERISTICS PARAMETERS SYMBOL TTL High Level Output Voltage VOH1 CMOS High Level Output Voltage CONDITIONS GROUP A SUBGROUPS LIMITS TEMPERATURE -35oC, +25oC, MIN MAX UNITS 3.0 - V VDD = 4.75V, IO = -2.5mA VIN = 0V or VDD 1, 2, 3 VOH2 VDD = 4.75V, IO = -100µA VIN = 0V or VDD 1, 2, 3 -35oC, +25oC, +125oC VDD 0.4V - V Low Level Output Voltage VOL VDD = 4.75V, IO = +2.5mA VIN = 0V or VDD 1, 2, 3 -35oC, +25oC, +125oC - 0.4 V Input Leakage Current IIH or IIL VDD = 5.25V VIN = 0V or VDD Pins: 17-19, 21-23, 33 1, 2, 3 -35oC, +25oC, +125oC -1.0 1.0 µA VDD = 5.25V VIN = 0V or VDD Pins: 2-16, 26-29, 32, 34-39 1, 2, 3 -35oC, +25oC, +125oC -10 10 µA Output Leakage Current IOZL or IOZH +125oC Input Current Bus Hold High IBHH VDD = 4.75V and 5.25V VIN = 3.0V (Note 1) Pins: 2-16, 26-32, 34-39 1, 2, 3 -35oC, +25oC, +125oC -600 -40 µA Input Current Bus Hold Low IBHL VDD = 4.75V and 5.25V VIN = 0.8V (Note 2) Pins: 2-16, 34-39 1, 2, 3 -35oC, +25oC, +125oC 40 600 µA Standby Power Supply Current IDDSB VDD = 5.25V, VIN = GND or VDD, IO = 0mA (Note 3) 1, 2, 3 -35oC, +25oC, +125oC - 500 µA Operating Power Supply Current IDDOP VDD = 5.25V, VIN = GND or VDD, IO = 0mA, f = 1MHz 1, 2, 3 -35oC, +25oC, +125oC - 12 mA/MHz Functional Tests FT VDD = 4.75V and 5.25V, VIN = GND or VDD, f = 1MHz 7, 8A, 8B -35oC, +25oC, +125oC - - - Noise Immunity Functional Tests FN VDD = 4.75V and 5.25V, VIN = GND or 3.5V and VDD = 4.5V, VIN = 0.8V or VDD (Note 4) 7, 8A, 8B -35oC, +25oC, +125oC - - - NOTES: 1. IBHH should be measured after raising VIN to VDD and then lowering to 3.0V. 2. IBHL should be measured after lowering VIN to VSS and then raising to 0.8V. 3. IDDSB tested during Clock high time after halt instruction executed. 4. CLK and MN/MX Input High (VIHC) = VDD -0.8 Spec Number 862 518055 Specifications HS-80C86RH TABLE 2A. AC ELECTRICAL PERFORMANCE CHARACTERISTICS (MIN MODE) ACs tested at worst case VDD, ACs guaranteed over full operating specifications. PARAMETERS SYMBOL CONDITIONS GROUP A SUBGROUPS LIMITS TEMPERATURE MIN MAX UNITS CLK Cycle Period TCLCL VDD = 4.75V VDD = 5.25V 9, 10, 11 -35oC, +25oC, +125oC 200 - ns CLK Low Time TCLCH VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 118 - ns CLK High Time TCHCL VDD = 4.75V VDD = 5.25V 9, 10, 11 -35oC, +25oC, +125oC 69 - ns Data in Setup Time TDVCL VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 30 - ns Data in Hold Time TCLDX1 VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 10 - ns Ready Setup Time into 80C86RH TRYHCH VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 113 - ns Ready Hold Time into 80C86RH TCHRYX VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 30 - ns Ready Inactive to CLK (Note 2) TRYLCL VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC -8 - ns Hold Setup Time THVCH VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 35 - ns INTR, NMI, Test/Setup Time TINVCH VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 30 - ns MIN MODE TIMING RESPONSES (CL = 100pF) Address Valid Delay TCLAV VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 10 110 ns ALE Width TLHLL VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC TCLCH 20 - ns ALE Active Delay TCLLH VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC - 80 ns ALE Inactive Delay TCHLL VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC - 85 ns Address Hold Time to ALE Inactive TLLAX VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC TCHCL 10 - ns Control Active Delay 1 TCVCTV VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 10 110 ns Control Active Delay 2 TCHCTV VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 10 110 ns Control Inactive Delay TCVCTX VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 10 110 ns RD Active Delay TCLRL VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 10 165 ns RD Inactive Delay TCLRH VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 10 150 ns RD Inactive to Next Address Active TRHAV VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC TCLCL 45 - ns HLDA Valid Delay TCLHAV VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 10 160 ns Spec Number 863 518055 Specifications HS-80C86RH TABLE 2A. AC ELECTRICAL PERFORMANCE CHARACTERISTICS (MIN MODE) (Continued) ACs tested at worst case VDD, ACs guaranteed over full operating specifications. PARAMETERS SYMBOL CONDITIONS GROUP A SUBGROUPS LIMITS TEMPERATURE MIN MAX UNITS RD Width TRLRH VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 2TCLCL 75 - ns WR Width TWLWH VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 2TCLCL 60 - ns Address Valid to ALE Low TAVLL VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC TCLCH 60 - ns Output Rise Time TOLOH VDD = 4.75V From 0.8V to 2.0V 9, 10, 11 -35oC, +25oC, +125oC - 20 ns Output Fall Time TOHOL VDD = 4.75V From 2.0V to 0.8V 9, 10, 11 -35oC, +25oC, +125oC - 20 ns NOTES: 1. Setup requirement for asynchronous signal only to guarantee recognition at next CLK. 2. Applies only to T2 State (8ns into T3). TABLE 2B. AC ELECTRICAL PERFORMANCE CHARACTERISTICS (MAX MODE) ACs tested at worst case VDD, ACs guaranteed over full operating specifications. PARAMETERS SYMBOL CONDITIONS GROUP A SUBGROUPS LIMITS TEMPERATURE MIN MAX UNITS TIMING REQUIREMENTS CLK Cycle Period TCLCL VDD = 4.75V VDD = 5.25V 9, 10, 11 -35oC, +25oC, +125oC 200 - ns CLK Low Time TCLCH VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 118 - ns CLK High Time TCHCL VDD = 4.75V VDD = 5.25V 9, 10, 11 -35oC, +25oC, +125oC 69 - ns Data in Setup Time TDVCL VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 30 - ns Data in Hold Time TCLDX1 VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 10 - ns Ready Setup Time into 80C86RH TRYHCH VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 113 - ns Ready Hold Time into 80C86RH TCHRYX VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 30 - ns Ready Inactive to CLK (Note 2) TRYLCL VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC -8 - ns INTR, NMI, Test/Setup Time TINVCH VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 30 - ns RQ/GT Setup Time TGVCH VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 30 - ns RQ Hold Time into HS-80C86RH (Note 3) TCHGX VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 40 TCHCL + 10 ns MAX MODE TIMING RESPONSES (CL = 100pF) Ready Active to Status Passive (Notes 2 and 4) Status Active Delay TRYHSH VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC - 110 ns TCHSV VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 10 110 ns Spec Number 864 518055 Specifications HS-80C86RH TABLE 2B. AC ELECTRICAL PERFORMANCE CHARACTERISTICS (MAX MODE) (Continued) ACs tested at worst case VDD, ACs guaranteed over full operating specifications. PARAMETERS SYMBOL CONDITIONS GROUP A SUBGROUPS VDD = 4.75V LIMITS TEMPERATURE -35oC, 9, 10, 11 +25oC, MIN MAX UNITS 10 130 ns Status Inactive Delay (Note 4) TCLSH Address Valid Delay TCLAV VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 10 110 ns RD Active Delay TCLRL VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 10 165 ns RD Inactive Delay TCLRH VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 10 150 ns RD Inactive to Next Address Active TRHAV VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC TCLCL 45 - ns GT Active Delay TCLGL VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 0 85 ns GT Inactive Delay TCLGH VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 0 85 ns RD Width TRLRH VDD = 4.75V 9, 10, 11 -35oC, +25oC, +125oC 2TCLCL 75 - ns Output Rise Time TOLOH VDD = 4.75V From 0.8V to 2.0V 9, 10, 11 -35oC, +25oC, +125oC - 20 ns Output Fall Time TOHOL VDD = 4.75V From 2.0V to 0.8V 9, 10, 11 -35oC, +25oC, +125oC - 20 ns +125oC NOTES: 1. Setup requirement for asynchronous signal only to guarantee recognition at next CLK. 2. Applies only to T2 State (8ns into T3). 3. The HS-80C86RH actively pulls the RQ/GT pin to a logic one on the following clock low time. 4. Status lines return to their inactive (logic one) state after CLK goes low and READY goes high. TABLE 3A. ELECTRICAL PERFORMANCE CHARACTERISTICS LIMITS PARAMETERS Input Capacitance SYMBOL CONDITIONS TEMPERATURE MIN MAX UNITS +25oC - 15 pF CIN VDD = Open, f = 1MHz (Note 1) TA = COUT VDD = Open, f = 1MHz (Note 1) TA = +25oC - 15 pF CI/O VDD = Open, f = 1MHz (Note 1) TA = +25oC - 20 pF CLK Rise Time TCH1CH2 VDD = 4.75V and 5.25V Min and Max Mode from 1.0V to 3.5V -35oC < TA < +125oC - 15 ns CLK Fall Time TCL2CL1 VDD = 4.75V and 5.25V Min and Max Mode from 3.5V to 1.0V -35oC < TA < +125oC - 15 ns Input Rise Time TILIH VDD = 4.75V and 5.25V Min and Max Mode from 0.8V to 2.0V -35oC < TA < +125oC - 25 ns Input Fall Time TIHIL VDD = 4.75V and 5.25V Min and Max Mode from 2.0V to 0.8V -35oC < TA < +125oC - 25 ns Output Capacitance I/O Capacitance TIMING REQUIREMENTS Spec Number 865 518055 Specifications HS-80C86RH TABLE 3A. ELECTRICAL PERFORMANCE CHARACTERISTICS (Continued) LIMITS PARAMETERS SYMBOL CONDITIONS TEMPERATURE MIN MAX UNITS Address Hold Time TCLAX VDD = 4.75V and 5.25V Min and Max Mode -35oC < TA < +125oC 10 - ns Address Float Delay (Note 2) TCLAZ VDD = 4.75V and 5.25V Min and Max Mode -35oC < TA < +125oC TCLAX 80 ns Data Valid Delay TCLDV VDD = 4.75V and 5.25V Min and Max Mode -35oC < TA < +125oC 10 110 ns Data Hold Time TCLDX2 VDD = 4.75V and 5.25V Min and Max Mode -35oC < TA < +125oC 10 - ns Data Hold Time After WR TWHDX VDD = 4.75V and 5.25V Min Mode -35oC < TA < +125oC TCLCL - 30 - ns Status Float Delay (Note 2) TCHSZ VDD = 4.75V and 5.25V Max Mode -35oC < TA < +125oC - 80 ns Address Float to Read Active (Note 2) TAZRL VDD = 4.75V and 5.25V Min and Max Mode -35oC < TA < +125oC 0 - ns TIMING RESPONSES NOTES: 1. All measurements referenced to device ground. 2. Output drivers disabled. Bus hold circuitry still active. 3. The parameters are controlled via design or process parameters and are not directly tested. These parameters are characterized upon initial design release and upon design changes which would affect these characteristics. TABLE 3B. ELECTRICAL PERFORMANCE CHARACTERISTICS Timing Signals at HS-82C85RH or 82C88 for Reference Only. LIMITS PARAMETERS SYMBOL CONDITIONS TEMPERATURE MIN MAX UNITS RDY Setup Time into HS-82C85RH (Note 1) TR1VCL Min and Max Mode -35oC < TA < +125oC 35 - ns RDY Hold Time into HS-82C85RH (Note 1) TCLR1X Min and Max Mode -35oC < TA < +125oC 0 - ns Command Active Delay TCLML Max Mode Only -35oC < TA < +125oC 5 35 ns Command Inactive TCLMH Max Mode Only -35oC < TA < +125oC 5 35 ns Status Valid to ALE High TSVLH Max Mode Only -35oC < TA < +125oC - 20 ns Status Valid to MCE High TSVMCH Max Mode Only -35oC < TA < +125oC - 30 ns CLK Low to ALE Valid TCLLH Max Mode Only -35oC < TA < +125oC - 20 ns CLK Low to MCE High TCLMCH Max Mode Only -35oC < TA < +125oC - 25 ns ALE Inactive Delay TCHLL Max Mode Only -35oC < TA < +125oC 4 18 ns MCE Inactive Delay TCLMCL Max Mode Only -35oC < TA < +125oC - 15 ns Control Active Delay TCVNV Max Mode Only -35oC < TA < +125oC 5 45 ns Control Inactive Delay TCVNX Max Mode Only -35oC < TA < +125oC 10 45 ns NOTE: 1. Setup requirement for asynchronous signal only to guarantee recognition at next CLK. TABLE 4. POST 100K RAD ELECTRICAL PERFORMANCE CHARACTERISTICS NOTE: See 25oC limits in Table 1 and Table 2 for Post RAD limits (Subgroups 1, 7 and 9). Spec Number 866 518055 Specifications HS-80C86RH TABLE 5. BURN-IN DELTA PARAMETERS (+25oC) PARAMETER SYMBOL DELTA LIMITS IDDSB ±100µA IOZL, IOZH ± 2µA IIH, IIL ± 200nA VOL ± 80mV TTL High Level Output Voltage VOH1 ± 600mV CMOS High Level Output Voltage VOH2 ±150mV Standby Power Supply Current Output Leakage Current Input Leakage Current Low Level Output Voltage TABLE 6. APPLICABLE SUBGROUPS GROUP A SUBGROUPS CONFORMANCE GROUP MIL-STD-883 METHOD TESTED FOR -Q RECORDED FOR -Q TESTED FOR -8 Initial Test 100%/5004 1, 7, 9 1 (Note 2) 1, 7, 9 Interim Test 1 100%/5004 1, 7, 9, ∆ 1, ∆ (Note 2) 1, 7, 9 PDA 1 100%/5004 1, 7, ∆ Interim Test 2 100%/5004 1, 7, 9, ∆ RECORDED FOR -8 1, 7 1, ∆ (Note 2) N/A PDA 2 100%/5004 1, 7, ∆ N/A Final Test 100%/5004 2, 3, 8A, 8B, 10, 11 2, 3, 8A, 8B, 10, 11 Group A (Note 1) Sample 5005 1, 2, 3, 7, 8A, 8B, 9, 10, 11 1, 2, 3, 7, 8A, 8B, 9, 10, 11 Subgroup B5 Sample 5005 1, 2, 3, 7, 8A, 8B, 9, 10, 11 Subgroup B6 Sample 5005 1, 7, 9 Group C Sample 5005 N/A Group D Sample 5005 1, 7, 9 1, 7, 9 Group E, Subgroup 2 Sample 5005 1, 7, 9 1, 7, 9 1, 2, 3 (Note 2) N/A N/A 1, 2, 3, 7, 8A, 8B, 9, 10, 11 N/A NOTES: 1. Alternate Group A testing in accordance with MIL-STD-883 method 5005 may be exercised. 2. Table 5 parameters only. Functional Description Static Operation All HS-80C86RH circuitry is of static design. Internal registers, counters and latches are static and require no refresh as with dynamic circuit design. This eliminates the minimum operating frequency restriction placed on other microprocessors. The CMOS HS-80C86RH can operate from DC to 5MHz. The processor clock may be stopped in either state (HIGH/LOW) and held there indefinitely. This type of operation is especially useful for system debug or power critical applications. The HS-80C86RH can be single stepped using only the CPU clock. This state can be maintained as long as is necessary. Single step clock operation allows simple interface circuitry to provide critical information for bringing up your system. Static design also allows very low frequency operation (down to DC). In a power critical situation, this can provide extremely low power operation since HS-80C86RH power dissipation is directly related to operating frequency. As the system frequency is reduced, so is the operating power until, ultimately, at a DC input frequency, the HS-80C86RH power requirement is the standby current, (500µA maximum). Internal Architecture The internal functions of the HS-80C86RH processor are partitioned logically into two processing units. The first is the Bus Interface Unit (BIU) and the second is the Execution Unit (EU) as shown in the CPU functional diagram. These units can interact directly but for the most part perform as separate asynchronous operational processors. The bus interface unit provides the functions related to instruction fetching and queuing, operand fetch and store, and address relocation. This unit also provides the basic bus control. The overlap of instruction pre-fetching provided by this unit serves to increase processor performance through improved bus bandwidth utilization. Up to 6 bytes of the instruction stream can be queued while waiting for decoding and execution. Spec Number 867 518055 HS-80C86RH The instruction stream queuing mechanism allows the BlU to keep the memory utilized very efficiently. Whenever there is space for at least 2 bytes in the queue, the BlU will attempt a word fetch memory cycle. This greatly reduces “dead-time” on the memory bus. The queue acts as a First-In-First-Out (FlFO) buffer, from which the EU extracts instruction bytes as required. If the queue is empty (following a branch instruction, for example), the first byte into the queue immediately becomes available to the EU. The execution unit receives pre-fetched instructions from the BlU queue and provides un-relocated operand addresses to the BlU. Memory operands are passed through the BlU for processing by the EU, which passes results to the BlU for storage. Memory Organization The processor provides a 20-bit address to memory, which locates the byte being referenced. The memory is organized as a linear array of up to 1 million bytes, addressed as 00000(H) to FFFFF(H). The memory is logically divided into code, data, extra and stack segments of up to 64K bytes each, with each segment falling on 16 byte boundaries. (See Figure 1). FFFFFH 64K BIT CODE SEGMENT XXXXOH STACK SEGMENT + OFFSET SEGMENT REGISTER FILE DATA SEGMENT CS SS DS ES EXTRA SEGMENT All memory references are made relative to base addresses contained in high speed segment registers. The segment types were chosen based on the addressing needs of programs. The segment register to be selected is automatically chosen according to the specific rules of Table 7. All information in one segment type share the same logical attributes (e.g. code or data). By structuring memory into relocatable areas of similar characteristics and by automatically selecting segment registers, programs are shorter, faster and more structured. (See Table 7). Word (16-bit) operands can be located on even or odd address boundaries and are thus not constrained to even boundaries as is the case in many 16-bit computers. For address and data operands, the least significant byte of the word is stored in the lower valued address location and the most significant byte in the next higher address location. The BlU automatically performs the proper number of memory accesses, one if the word operand is on an even byte boundary and two if it is on an odd byte boundary. Except for the performance penalty, this double access is transparent to the software. The performance penalty does not occur for instruction fetches; only word operands. Physically, the memory is organized as a high bank (D15D6) and a low bank (D7-D0) of 512K bytes addressed in parallel by the processor’s address lines. Byte data with even addresses is transferred on the D7-D0 bus lines while odd addressed byte data (A0 HIGH) is transferred on the D15-D6 bus lines. The processor provides two enable signals, BHE and A0, to selectively allow reading from or writing into either an odd byte location, even byte location, or both. The instruction stream is fetched from memory as words and is addressed internally by the processor at the byte level as necessary. In referencing word data, the BlU requires one or two memory cycles depending on whether the starting byte of the word is on an even or odd address, respectively. Consequently, in referencing word operands performance can be optimized by locating data on even address boundaries. This is an especially useful technique for using the stack, since odd address references to the stack may adversely affect the context switching time for interrupt processing or task multiplexing. 00000H FIGURE 1. HS-80C86RH MEMORY ORGANIZATION TABLE 7. TYPE OF MEMORY REFERENCE Instruction Fetch DEFAULT SEGMENT BASE ALTERNATE SEGMENT BASE CS None IP SP OFFSET Stack Operation SS None Variable (Except Following) DS CS, ES, SS Effective Address String Source DS CS, ES, SS SI String Destination ES None DI BP Used as Base Register SS CS, DS, ES Effective Address Certain locations in memory are reserved for specific CPU operations (See Figure 2). Locations from address FFFF0H through FFFFFH are reserved for operations including a jump to the initial program loading routine. Following RESET, the CPU will always begin execution at location FFFF0H where the jump must be located. Locations 00000H through 003FFH are reserved for interrupt operations. Each of the 256 possible interrupt service routines is accessed through its own pair of 16-bit pointers - segment address pointer and offset address pointer. The first pointer, used as the offset address, is loaded into the 1P and the second pointer, which designates the base address is loaded into the CS. At this point program control is transferred to the interrupt routine. The pointer elements are assumed to have been stored at the respective places in reserved memory prior to occurrence of interrupts. Spec Number 868 518055 HS-80C86RH RESET BOOTSTRAP PROGRAM JUMP INTERRUPT POINTER FOR TYPE 255 FFFFFH Status bits S0, S1 and S2 are used by the bus controller, in maximum mode, to identify the type of bus transaction according to Table 8. FFFFOH TABLE 8. 3FFH S2 S1 S0 0 0 0 Interrupt Acknowledge 0 0 1 Read I/O Port 0 1 0 Write I/O Port 0 1 1 Halt 1 0 0 Instruction Fetch 1 0 1 Read Data from Memory Minimum and Maximum Operation Modes 1 1 0 Write Data to Memory The requirements for supporting minimum and maximum HS-80C86RH systems are sufficiently different that they cannot be met efficiently using 40 uniquely defined pins. Consequently, the HS-80C86RH is equipped with a strap pin (MN/MX) which defines the system configuration. The definition of a certain subset of the pins changes, dependent on the condition of the strap pin. When the MN/MX pin is strapped to GND, the HS-80C86RH defines pins 24 through 31 and 34 in maximum mode. When the MN/MX pin is strapped to VDD, the HS-80C86RH generates bus control signals itself on pins 24 through 31 and 34. 1 1 1 Passive (no bus cycle) 3FCH 7H INTERRUPT POINTER FOR TYPE 1 INTERRUPT POINTER FOR TYPE 0 4H 3H 0H FIGURE 2. RESERVED MEMORY LOCATIONS CHARACTERISTICS Status bits S3 through S7 are time multiplexed with high order address bits and the BHE signal, and are therefore valid during T2 through T4. S3 and S4 indicate which segment register (see Instruction Set Description) was used for this bus cycle in forming the address, according to Table 9. TABLE 9. S4 S3 CHARACTERISTICS 0 (Low) 0 Alternate Data (extra segment) 0 1 Stack 1 (High) 0 Code or None 1 1 Data Bus Operation The HS-80C86RH has a combined address and data bus commonly referred to as a time multiplexed bus. This technique provides the most efficient use of pins on the processor while permitting the use of a standard 40-lead package. This “local bus” can be buffered directly and used throughout the system with address latching provided on memory and I/O modules. In addition, the bus can also be demultiplexed at the processor with a single set of 82C82 latches if a standard non-multiplexed bus is desired for the system. Each processor bus cycle consists of at least four CLK cycles. These are referred to as T1, T2, T3 and T4 (see Figure 3). The address is emitted from the processor during T1 and data transfer occurs on the bus during T3 and T4. T2 is used primarily for changing the direction of the bus during read operations. In the event that a “NOT READY” indication is given by the addressed device, “Wait” states (TW) are inserted between T3 and T4. Each inserted wait state is the same duration as a CLK cycle. Idle periods occur between HS-80C86RH driven bus cycles whenever the processor performs internal processing. During T1 of any bus cycle, the ALE (Address Latch Enable) signal is emitted (by either the processor or the 82C88 bus controller, depending on the MN/MX strap). At the trailing edge of this pulse, a valid address and certain status information for the cycle may be latched. S5 is a reflection of the PSW interrupt enable bit. S6 is always zero and S7 is a spare status bit. I/O Addressing In the HS-80C86RH, I/O operations can address up to a maximum of 64K I/O byte registers or 32K I/O word registers. The I/O address appears in the same format as the memory address on bus lines A15-A0. The address lines A19-A16 are zero in I/O operations. The variable I/O instructions which use register DX as a pointer have full address capability while the direct I/O instructions directly address one or two of the 256 I/O byte locations in page 0 of the I/O address space. I/O ports are addressed in the same manner as memory locations. Even addressed bytes are transferred on the D7D0 bus lines and odd addressed bytes on D15-D8. Care must be taken to ensure that each register within an 8-bit peripheral located on the lower portion of the bus be addressed as even. Spec Number 869 518055 HS-80C86RH (4 + NWAIT) = TCY T1 T2 T3 TWAIT (4 + NWAIT) = TCY T4 T1 T2 T3 TWAIT T4 CLK GOES INACTIVE IN THE STATE JUST PRIOR TO T4 ALE S2-S0 ADDR/ STATUS ADDR/DATA BHE, A19-A16 S7-S3 D15-D0 VALID A15-A0 A15-A0 DATA OUT (D15-D0) RD, INTA READY READY READY WAIT WAIT DT/R DEN MEMORY ACCESS TIME WP FIGURE 3. BASIC SYSTEM TIMING Spec Number 870 518055 HS-80C86RH External Interface Interrupt Operations Processor RESET and lnitialization Interrupt operations fall into two classes: software or hardware initiated. The software initiated interrupts and software aspects of hardware interrupts are specified in the Instruction Set Description. Hardware interrupts can be classified as non-maskable or maskable. Processor initialization or start up is accomplished with activation (HIGH) of the RESET pin. The HS-80C86RH RESET is required to be HIGH for greater than 4 CLK cycles. The HS-80C86RH will terminate operations on the high-going edge of RESET and will remain dormant as long as RESET is HIGH. The low-going transition of RESET triggers an internal reset sequence for approximately 7 CLK cycles. After this interval, the HS-80C86RH operates normally beginning with the instruction in absolute location FFFFOH. (See Figure 2). The RESET input is internally synchronized to the processor clock. At initialization, the HIGH-to-LOW transition of RESET must occur no sooner than 50µs (or 4 CLK cycles, whichever is greater) after power-up, to allow complete initialization of the HS-80C86RH. NMl will not be recognized prior to the second clock cycle following the end of RESET. If NMI is asserted sooner than 9 CLK cycles after the end of RESET, the processor may execute one instruction before responding to the interrupt. Bus Hold Circuitry To avoid high current conditions caused by floating inputs to CMOS devices and to eliminate need for pull- up/down resistors, “bus-hold” circuitry has been used on the HS-80C86RH pins 2-16, 26-32 and 34-39. (See Figure 4A and 4B). These circuits will maintain the last valid logic state if no driving source is present (i.e. an unconnected pin or a driving source which goes to a high impedance state). To overdrive the “bus hold” circuits, an external driver must be capable of supplying approximately 400µA minimum sink or source current at valid input voltage levels. Since this “bus hold” circuitry is active and not a “resistive” type element, the associated power supply current is negligible and power dissipation is significantly reduced when compared to the use of passive pull-up resistors. BOND PAD EXTERNAL PIN INPUT BUFFER INPUT PROTECTION CIRCUITRY FIGURE 4A. BUS HOLD CIRCUITRY PIN 2-16, 34-39 BOND PAD INPUT BUFFER Non-Maskable Interrupt (NMI) The processor provides a single non-maskable interrupt pin (NMl) which has higher priority than the maskable interrupt request pin (INTR). A typical use would be to activate a power failure routine. The NMl is edge-triggered on a LOWto-HIGH transition. The activation of this pin causes a type 2 interrupt. NMl is required to have a duration in the HIGH state of greater than 2 CLK cycles, but is not required to be synchronized to the clock. Any positive transition of NMl is latched on-chip and will be serviced at the end of the current instruction or between whole moves of a block-type instruction. Worst case response to NMl would be for multiply, divide, and variable shift instructions. There is no specification on the occurrence of the low-going edge; it may occur before, during or after the servicing of NMl. Another positive edge triggers another response if it occurs after the start of the NMl procedure. The signal must be free of logical spikes in general and be free of bounces on the low-going edge to avoid triggering extraneous responses. Maskable Interrupt (INTR) OUTPUT DRIVER OUTPUT DRIVER Interrupts result in a transfer of control to a new program location. A 256-element table containing address pointers to the interrupt service routine locations resides in absolute locations 0 through 3FFH, which are reserved for this purpose. Each element in the table is 4 bytes in size and corresponds to an interrupt “type”. An interrupting device supplies an 8-bit type number during the interrupt acknowledge sequence, which is used to “vector” through the appropriate element to the interrupt service routine location. All flags and both the Code Segment and Instruction Pointer register are saved as part of the INTA sequence. These are restored upon execution of an Interrupt Return (lRET) instruction. VCC EXTERNAL PIN P INPUT PROTECTION CIRCUITRY The HS-80C86RH provides a single interrupt request input (INTR) which can be masked internally by software with the resetting of the interrupt enable flag (IF) status bit. The interrupt request signal is level triggered. It is internally synchronized during each clock cycle on the high-going edge of CLK. To be responded to, INTR must be present (HIGH) during the clock period preceding the end of the current instruction or the end of a whole move for a block- type instruction. INTR may be removed anytime after the falling edge of the first INTA signal. During the interrupt response sequence further interrupts are disabled. The enable bit is reset as part of the response to any interrupt (INTR, NMl, software interrupt or single-step), although the FLAGS register which is automatically pushed onto the stack reflects the state of the processor prior to the interrupt. Until the old FLAGS register is restored the enable bit will be zero unless specifically set by an instruction. FIGURE 4B. BUS HOLD CIRCUITRY PIN 26-32 Spec Number 871 518055 HS-80C86RH During the response sequence (Figure 5) the processor executes two successive (back-to-back) interrupt acknowledge cycles. The HS-80C86RH emits the LOCK signal (Max mode only) from T2 of the first bus cycle until T2 of the second. A local bus “hold” request will not be honored until the end of the second bus cycle. In the second bus cycle, a byte is supplied to the HS-80C86RH by the HS-82C89ARH Interrupt Controller, which identifies the source (type) of the interrupt. This byte is multiplied by four and used as a pointer into the interrupt vector lookup table. An INTR signal left HIGH will be continually responded to within the limitations of the enable bit and sample period. The INTERRUPT RETURN instruction includes a FLAGS pop which returns the status of the original interrupt enable bit when it restores the FLAGS. T1 T2 T3 T4 TI T1 T2 T3 If a local bus request occurs during WAIT execution, the HS80C86RH three-states all output drivers while inputs and I/O pins are held at valid logic levels by internal bus-hold circuits. If interrupts are enabled, the HS-80C86RH will recognize interrupts and process them when it regains control of the bus. The WAIT instruction is then refetched, and reexecuted. Typical system configurations for the processor operating in minimum mode and in maximum mode are shown in Figures 6A and 6B, respectively. In minimum mode, the MN/MX pin is strapped to VDD and the processor emits bus control signals (e.g. RD, WR, etc.) directly. In maximum mode, the MN/MX pin is strapped to GND and the processor emits coded status information which the 82C88 bus controller used to generate MULTIBUS™ compatible bus control signals. Figure 3 shows the signal timing relationships. LOCK INTA FLOAT As an alternative to interrupts, the HS-80C86RH provides a single software-testable input pin (TEST). This input is utilized by executing a WAIT instruction. The single WAIT instruction is repeatedly executed until the TEST input goes active (LOW). The execution of WAIT does not consume bus cycles once the queue is full. Basic System Timing T4 ALE AD0AD15 External Synchronization Via TEST TYPE VECTOR TABLE 10. HS-80C86RH REGISTER MODEL FIGURE 5. INTERRUPT ACKNOWLEDGE SEQUENCE Halt When a software “HALT” instruction is executed the pro- cessor indicates that it is entering the “HALT” state in one of two ways depending upon which mode is strapped. In minimum mode, the processor issues one ALE with no qualifying bus control signals. In maximum mode the processor issues appropriate HALT status on S2, S1, S0 and the 82C88 bus controller issues one ALE. The HS-80C86RH will not leave the “HALT” state when a local bus “hold” is entered while in “HALT”. In this case, the processor reissues the HALT indicator at the end of the local bus hold. An NMl or interrupt request (when interrupts enabled) or RESET will force the HS-80C86RH out of the “HALT” state. AH AL ACCUMULATOR BX BH BL BASE CX CH CL COUNT DX DH DL DATA SP STACK POINTER BP BASE POINTER SI SOURCE INDEX DI DESTINATION INDEX IP FLAGSH Read/Modify/Write (Semaphore) Operations Via Lock AX INSTRUCTION POINTER FLAGSL STATUS FLAGS CS CODE SEGMENT DS DATA SEGMENT SS STACK SEGMENT ES EXTRA SEGMENT MULTIBUS™ is an Intel Trademark The LOCK status information is provided by the processor when consecutive bus cycles are required during the execution of an instruction. This gives the processor the capability of performing read/modify/write operations on memory (via the Exchange Register With Memory instruction, for example) without another system bus master receiving intervening memory cycles. This is useful in multiprocessor system configurations to accomplish “test and set lock” operations. The LOCK signal is activated (forced LOW) in the clock cycle following decoding of the software “LOCK” prefix instruction. It is deactivated at the end of the last bus cycle of the instruction following the “LOCK” prefix instruction. While LOCK is active a request on a RQ/GT pin will be recorded and then honored at the end of the LOCK. System Timing - Minimum System The read cycle begins in T1 with the assertion of the Address Latch Enable (ALE) signal. The trailing (low-going) edge of this signal is used to latch the address information, which is valid on the address/data bus (AD0-AD15) at this time, into the 82C82 latches. The BHE and A0 signals address the low, high or both bytes. From T1 to T4 the M/IO signal indicates a memory or I/O operation. At T2, the address is removed from the address/data bus and the bus is held at the last valid logic state by internal bus hold devices. The read control signal is also asserted at T2. The read (RD) signal causes the addressed device to enable its data bus drivers to the local bus. Some time later, valid data Spec Number 872 518055 HS-80C86RH will be available on the bus and the addressed device will drive the READY line HIGH. When the processor returns the read signal to a HIGH level, the addressed device will threestate its bus drivers. If a transceiver is required to buffer the HS-80C86RH local bus, signals DT/R and DEN are provided by the HS-80C86RH. A write cycle also begins with the assertion of ALE and the emission of the address. The M/IO signal is again asserted to indicate a memory or I/O write operation. In T2, immediately following the address emission, the processor emits the data to be written into the addressed location. This data remains valid until at least the middle of T4. During T2, T3 and TW, the processor asserts the write control signal. The write (WR) signal becomes active at the beginning of T2 as opposed to the read which is delayed somewhat into T2 to provide time for output drivers to become inactive. The BHE and A0 signals are used to select the proper byte(s) of the memory/IO word to be read or written according to Table 11. TABLE 11. BHE A0 0 0 Whole word 0 1 Upper byte from/to odd address 1 0 Lower byte from/to even address 1 1 None Bus Timing - Medium and Large Size Systems For medium complexity systems the MN/MX pin is connected to GND and the 82C88 Bus Controller is added to the system as well as three 82C82 latches for latching the system address, and a transceiver to allow for bus loading greater than the HS-80C86RH is capable of handling. Bus control signals are generated by the 82C88 instead of the processor in this configuration, although their timing remains relatively the same. The HS-80C86RH status outputs (S2, S1, and S0) provide type-of-cycle information and become 82C88 inputs. This bus cycle information specifies read (code, data or I/O), write (data or I/O), interrupt acknowledge, or software halt. The 82C88 issues control signals specifying memory read or write, I/O read or write, or interrupt acknowledge. The 82C88 provides two types of write strobes, normal and advanced, to be applied as required. The normal write strobes have data valid at the leading edge of write. The advanced write strobes have the same timing as read strobes, and hence, data is not valid at the leading edge of write. The transceiver receives the usual T and 0E inputs from the 82C88 DT/R and DEN signals. For large multiple processor systems, the 82C89 bus arbiter must be added to the system to provide system bus management. In this case, the pointer into the interrupt vector table, which is passed during the second INTA cycle, can be derived from an HS-82C59ARH located on either the local bus or the system bus. The processor’s INTA output should drive the SYSB/RESB input of the 82C89 to the proper state when reading the interrupt vector number from the HS82C59ARH during the interrupt acknowledge sequence and software “poll”. CHARACTERISTICS A Note on Radiation Hardened Product Availability I/O ports are addressed in the same manner as memory location. Even addressed bytes are transferred on the D7-D0 bus lines and odd address bytes on D15-D6. There are no immediate plans to develop the 82C88 Bus Controller or the 82C89 Arbiter as radiation hardened integrated circuits. The basic difference between the interrupt acknowledge cycle and a read cycle is that the interrupt acknowledge signal (INTA) is asserted in place of the read (RD) signal and the address bus is held at the last valid logic state by internal bus hold devices. (See Figure 4). In the second of two successive INTA cycles a byte of information is read from the data bus (D7-D0) as supplied by the interrupt system logic (i.e. HS-82CS9ARH Priority Interrupt Controller). This byte identifies the source (type) of the interrupt. It is multiplied by four and used as a pointer into an interrupt vector Iookup table, as described earlier. A Note on SEU Capability of the HS-80C86RH Previous heavy ion testing of the HS-80C86RH has indicated that the SEU threshold of this part is about 6 MEV/mg/cm2. Based upon these results and other analysis, a deep space galactic cosmic-ray environment will result in an SEU rate of about 0.08 upsets/day. Spec Number 873 518055 HS-80C86RH VDD RES HS-82C85RH CLOCK CONTROLLER/ GENERATOR RDY CLK GND MN/MX S0 READY S1 RESET S2 LOCK WAIT STATE GENERATOR NC NC NC STB GND 1 VDD MRDC MWTC 82C88 S1 BUS AMWC S2 CTRLR IORC IOWC DEN DT/R AIOWC ALE INTA HS-80C86RH CPU GND CLK S0 C1 GND AD0-AD15 A16-A19 OE ADDR/DATA BHE 20 ADDR 82C82 (2 OR 3) GND C2 40 T/R VDD OE HS-82C08RH TRANSCEIVER (2) C1 = C2 = 0.1µF DATA A0 BHE E W E HS-65262RH CMOS RAM (16) 16K x 1 G HS-6617RH CMOS PROM (2) 2K x 8 2K x 8 CS RD WR CMOS HS-82CXXRH PERIPHERALS FIGURE 6A. MAXIMUM MODE HS-80C86RH TYPICAL CONFIGURATION VDD RES HS-82C85RH CLOCK CONTROLLER/ GENERATOR RDY CLK VDD MN/MX M/IO READY INTA RESET RD WR DT/R DEN GND WAIT STATE GENERATOR HS-80C86RH CPU ALE 1 VDD C1 AD0-AD15 A16-A19 BHE 20 STB GND GND ADDR/DATA OE ADDR 82C82 (2 OR 3) GND C2 40 C1 = C2 = 0.1µF VDD T/R OE DATA HS-82C08RH TRANSCEIVER (2) OPTIONAL FOR INCREASED DATA BUS DRIVE A0 BHE E W E HS-65262RH CMOS RAM (16) 16K x 1 G HS-6617RH CMOS PROM (2) 2K x 8 2K x 8 CS RD WR CMOS HS-82CXXRH PERIPHERALS FIGURE 6B. MINIMUM MODE HS-80C86RH TYPICAL CONFIGURATION Spec Number 874 518055 HS-80C86RH Waveforms T1 T2 T3 T4 TCL2CL1 TCH1CH2 TW CLK (HS-82C85RH OUTPUT) TCLDV TCLAX TCLAV AD15-AD0 AD15-AD0 TCLDX2 DATA OUT TWHDX TCVCTV WRITE CYCLE (NOTE 1) (RD, INTA, DT/R = VOH) TCVCTX DEN TCVCTV TWLWH WR TCVCTX TDVCL TCLAZ TCLDX1 POINTER AD15-AD0 TCHCTV TCHCTV DT/R INTA CYCLE (NOTES 1, 3) (RD, WR = VOH BHE = VOL) TCVCTV INTA TCVCTV TCVCTX DEN SOFTWARE HALT DEN, RD, WR, INTA = VOH INVALID ADDRESS AD15-AD0 DT/R = INDETERMINATE SOFTWARE HALT TCLAV FIGURE 7. BUS TIMING - MINIMUM MODE SYSTEM NOTES: 1. All signals switch between VOH and VOL unless otherwise specified. 2. RDY is sampled near the end of T2, T3, TW to determine if TW machines states are to be inserted. 3. Two INTA cycles run back-to-back. The HS-80C86RH local ADDR/DATA bus is inactive during both INTA cycles. Control signals are shown for the second INTA cycle. 4. Signals at HS-82C85RH are shown for reference only. 5. All timing measurements are made at 1.5V unless otherwise noted. Spec Number 875 518055 HS-80C86RH Waveforms (Continued) T1 T2 T3 T4 TCL2CL1 TCH1CH2 TCLCL TW CLK (HS-82C85RH OUTPUT) TCHCTV TCHCL TCHCTV TCLCH M/IO TCLDV TCLAX TCLAV TCLAV BHE, A19-A16 BHE/S7, A19/S6-A16/S3 TCLLH TLHLL S7-S3 TLLAX ALE TR1VCL TCHLL VIH RDY (HS-82C85RH INPUT) SEE NOTE 4 TAVLL VIL TCLRIX TRYLCL READY (HS-80C86RH INPUT) TCHRYX TRYHCH TCLDX1 TCLAZ AD15-AD0 READ CYCLE (NOTE 1) (WR, INTA = VOH) TDVCL AD15-AD0 DATA IN TAZRL TCLRH TRHAV RD TCHCTV TCLRL TRLRH TCHCTV DT/R TCVCTV TCVCTX DEN FIGURE 8. BUS TIMING - MINIMUM MODE SYSTEM NOTES: 1. All signals switch between VOH and VOL unless otherwise specified. 2. RDY is sampled near the end of T2, T3, TW to determine if TW machines states are to be inserted. 3. Two INTA cycles run back-to-back. The HS-80C86RH local ADDR/DATA bus is inactive during both INTA cycles. Control signals are shown for the second INTA cycle. 4. Signals at HS-82C85RH are shown for reference only. 5. All timing measurements are made at 1.5V unless otherwise noted. Spec Number 876 518055 HS-80C86RH Waveforms (Continued) T1 T2 TCH1CH2 T3 T4 TCL2CL1 TCLCL TW CLK TCHCL TCLCH TCLAV QS0, QS1 TCHSV TCLSH S2, S1, S0 (EXCEPT HALT) (SEE NOTE 8) TCLDV TCLAX TCLAV TCLAV BHE, A19-A16 BHE/S7, A19/S6-A16/S3 TSVLH TCLLH S7-S3 TCHLL ALE (82C88 OUTPUT) NOTE 5 TR1VCL RDY (HS-82C85RH INPUT) TCLR1X TRYLCL READY (HS-80C86RH INPUT) TCHRYX TRYHSH TCLAX TRYHCH TCLAV READ CYCLE TCLAZ TDVCL AD15-AD0 AD15-AD0 TAZRL TCLDX1 DATA IN TCLRH TRHAV RD TCHDTL TRLRH TCHDTH TCLRL DT/R TCLML 82C88 OUTPUTS SEE NOTES 5, 6 TCLMH MRDC OR IORC TCVNV DEN TCVNX FIGURE 9. BUS TIMING - MAXIMUM MODE SYSTEM NOTES: 1. All signals switch between VOH and VOL unless otherwise specified. 2. RDY is sampled near the end of T2, T3, TW to determine if TW machines states are to be inserted. 3. Cascade address is valid between first and second INTA cycle. 4. Two INTA cycles run back-to-back. The HS-80C86RH local ADDR/DATA bus is inactive during both INTA cycles. Control for pointer address is shown for the second INTA cycle. 5. Signals at HS-82C85RH or 82C88 are shown for reference only. 6. The issuance of the 82C88 command and control signals (MRDC, MWTC, AMWC, IORC, IOWC, AIOWC, INTA and DEN) lags the active high 82C88 CEN. 7. All timing measurements are made at 1.5V unless otherwise noted. 8. Status inactive in state just prior to T4. Spec Number 877 518055 HS-80C86RH Waveforms (Continued) T1 T2 T3 T4 TW CLK TCHSV (SEE NOTE 8) S2, S1, S0 (EXCEPT HALT) TCLSH TCLDV TCLAX TCLAV WRITE CYCLE TCLDX2 AD15-AD0 TCVNV DEN 82C88 OUTPUTS SEE NOTES 5, 6 TCLMH TCLML TCVNX AMWC OR AIOWC TCLMH TCLML MWTC OR IOWC INTA CYCLE AD15-AD0 (SEE NOTES 3, 4) RESERVED FOR CASCADE ADDR TCLAZ TDVCL AD15-AD0 POINTER TSVMCH TCLMCL MCE/PDEN TCLMCH DT/R 82C88 OUTPUTS SEE NOTES 5, 6 TCLDX1 TCHDTL TCHDTH TCLML INTA TCVNV TCLMH DEN TCVNX SOFTWARE HALT - RD, MRDC, IORC, MWTC, AMWC, IOWC, AIOWC, INTA, S0, S1 = VOH INVALID ADDRESS AD15-AD0 TCLAV S2 TCHSV TCLSH FIGURE 10. BUS TIMING - MAXIMUM MODE SYSTEM (USING 82C88) NOTES: 1. All signals switch between VOH and VOL unless otherwise specified. 2. RDY is sampled near the end of T2, T3, TW to determine if TW machines states are to be inserted. 3. Cascade address is valid between first and second INTA cycle. 4. Two INTA cycles run back-to-back. The HS-80C86RH local ADDR/DATA bus is inactive during both INTA cycles. Control for pointer address is shown for the second INTA cycle. 5. Signals at HS-82C85RH or 82C88 are shown for reference only. 6. The issuance of the 82C88 command and control signals (MRDC, MWTC, AMWC, IORC, IOWC, AIOWC, INTA and DEN) lags the active high 82C88 CEN. 7. All timing measurements are made at 1.5V unless otherwise noted. 8. Status inactive in state just prior to T4. Spec Number 878 518055 HS-80C86RH Waveforms (Continued) CLK TINVCH (SEE NOTE) NMI INTR NOTE: Setup Requirements for asynchronous signals only to guarantee recognition at next CLK. SIGNAL TEST FIGURE 11. ASYNCHRONOUS SIGNAL RECOGNITION ≥ 50µs ANY CLK CYCLE ANY CLK CYCLE VCC CLK CLK TCLAV TCLAV TCLDX TDVCL LOCK RESET ≥ 4 CLK CYCLES FIGURE 12. BUS LOCK SIGNAL TIMING (MAXIMUM MODE ONLY) ANY CLK CYCLE FIGURE 13. RESET TIMING ≥ 0-CLK CYCLES TCLGL TCLGH CLK TGVCH TCLGH TCLCL TCHGX RQ/GT PULSE 1 COPROCESSOR RQ PREVIOUS GRANT AD15-AD0 PULSE 2 HS-80C86RH GT PULSE 3 COPROCESSOR RELEASE TCLAZ HS-80C86RH TCHSZ RD, LOCK BHE/S7, A19/S6-A16/S3 S2, S1, S0 (SEE NOTE) TCHSV NOTE: The coprocessor may not drive the buses outside the region shown without risking contention. FIGURE 14. REQUEST/GRANT SEQUENCE TIMING (MAXIMUM MODE ONLY) ≥ 1CLK CYCLE 1 OR 2 CYCLES CLK THVCH THVCH HOLD TCLHAV TCLHAV HLDA TCLAZ AD15-AD0 80C86 COPROCESSOR 80C86 TCHSZ BHE/S7, A19/S6-A16/S3 RD, WR, M/IO, DT/R, DEN FIGURE 15. HOLD/HOLD ACKNOWLEDGE TIMING (MINIMUM MODE ONLY) Spec Number 879 518055 HS-80C86RH AC Test Circuit AC Testing Input, Output Waveform OUTPUT FROM DEVICE UNDER TEST INPUT VIH TEST POINT CL (Note) VIL - 0.4V OUTPUT VOH 1.5V 1.5V VOH NOTE: All inputs signals (other than CLK) must switch between VIL Max -0.4V and VIH Min +0.4. CLK must switch between 0.4V and VDD -0.4V. TR and TF must be less than or equal to 15ns. CLK TR and TF must be less than or equal to 10ns. NOTE: Includes stray and jig capacitance. Burn-In Circuits HS-80C86RH 40 PIN DIP HS-80C86RH 40 PIN DIP VDD VDD CLK 1 40 2 39 3 38 4 37 5 36 6 35 7 34 8 33 9 32 10 31 11 30 12 29 13 28 14 27 15 26 16 25 17 24 18 23 19 22 20 21 1 40 F15 2 39 F16 F14 3 38 LOAD F13 4 37 LOAD F12 5 36 LOAD F11 6 35 LOAD F10 7 34 LOAD F9 8 33 MN/MX F8 9 32 LOAD F7 10 31 F6 11 30 F5 12 29 LOAD F4 13 28 LOAD F3 14 27 LOAD F2 15 26 LOAD F1 16 25 LOAD NMI 17 24 LOAD 18 23 19 22 READY 20 21 RESET F0 VDD 2.7KΩ T T ≥ 5.0µs LOAD 2.7KΩ STATIC VDD = +6.5V ±10% TA = +125oC Minimum Part is Static Sensitive Voltages Must Be Ramped Package: 40 Lead DIP Resistors: 10kΩ ±10% (Pins 17, 18, 21-23, 31, 33) 2.7kΩ ±5% (Pins 2-16, 39) 1.0kΩ ±5% 1/10W Min (Pin 19) Minimum of 5 CLK Pulses After Initial Pulses, CLK is Left High Pulses are 50% Duty Cycle Square Wave DYNAMIC VDD = 6.5V ±5% (Burn-In) VDD = 6.0V ±5% (Life Test) TA = +125oC Package: 40 Lead DIP Part is Static Sensitive Voltage Must Be Ramped Resistors: 10kΩ (Pins 17, 18, 21, 22, 23, 33) 3.3kΩ (Pins 2-16, 19, 30, 31, 39) 2.7kΩ Loads As Indicated All Resistors Are At Least 1/8W, ±10% F0 = 100kHz, F1 = F0/2, F2 = F1/2 . . . RESET, NMI low after initialization. READY pulsed low every 320ms MN/MX changes state every 5.24s Spec Number 880 518055 HS-80C86RH Burn-In Circuits (Continued) HS-80C86RH 42 LEAD FLATPACK HS-80C86RH 42 LEAD FLATPACK VDD 1 42 2 41 3 40 4 39 5 38 6 37 7 36 8 35 9 34 10 33 11 32 12 31 13 30 14 CLK VDD 29 15 28 16 27 17 26 18 25 19 24 20 23 21 22 1 42 F15 2 41 F14 3 40 OPEN F13 4 39 LOAD F12 5 38 LOAD F11 6 37 LOAD F10 7 36 LOAD F9 8 35 LOAD F8 9 34 F7 10 33 F6 11 32 F5 12 31 F4 13 30 LOAD F3 14 29 LOAD F2 15 28 LOAD F1 16 27 LOAD 17 26 LOAD 18 25 LOAD 19 24 20 23 READY 21 22 RESET OPEN NMI F0 F16 MN/MX LOAD VDD 2.7kΩ LOAD STATIC VDD = +6.5V ±10% TA = +125oC Minimum Part is Static Sensitive Voltages Must Be Ramped Package: 42 Lead Flatpack Resistors: 10kΩ ±10% (Pins 18, 19, 22-24, 32, 34) 2.7kΩ ±5% (Pins 2-16, 41) 1.0kΩ ±5% 1/10W Min (Pin 20) Minimum of 5 CLK Pulses After Initial Pulses, CLK is Left High Pulses are 50% Duty Cycle Square Wave 2.7kΩ DYNAMIC VDD = 6.5V ±5% (Burn-In) VDD = 6.0V ±5% (Life Test) TA = +125oC Package: 42 Lead Flatpack Part is Static Sensitive Voltage Must Be Ramped Resistors: 10kΩ (Pins 17, 18, 19, 22, 23, 24, 34) 3.3kΩ (Pins 2-16, 20, 31, 32, 41) 2.7kΩ Loads As Indicated All Resistors Are At Least 1/8W, ±10% F0 = 100kHz, F1 = F0/2, F2 = F1/2 . . . RESET, NMI low after initialization. READY pulsed low every 320µs MN/MX changes state every 5.24s Spec Number 881 518055 HS-80C86RH Timing Diagrams F5 READY 4T READY TIMING AS COMPARED TO F5 F14 F16 PULSE RESET NMI RESET, NMI, AND MN/MX TIMING AS COMPARED TO F14 AND F16 F0 = 100kHz, 50% duty cycle square wave. F1 = F0/2, F2 = F1/2 . . . F16 = F15/2. RESET has a pulse width = 8T and occurs every two cycles of F16. NMI has a pulse width = 4T and occurs every two cycles of F16. READY, RESET, and NMI timing are as shown below: T = 10µs. MN/MX is a 50% duty cycle square wave and changes every eight cycles of F16. All signals have rise/fall time limits: 100ns < t-rise, t-fall < 500ns Irradiation Circuit VDD 1 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 VSS VCC 40 R2 39 2 R2 LOAD 3 38 4 37 LOAD 5 36 LOAD 6 35 LOAD 7 34 LOAD R2 8 MN/MX 33 9 32 10 HOLD 31 11 HLDA 30 R3 R3 29 LOAD R2 13 28 LOAD 14 27 LOAD R2 15 26 LOAD R2 16 25 LOAD 24 LOAD R3 R3 R3 CLOCK 17 NMI 18 INTR TEST 23 19 CLK READY 22 R3 21 R3 20 GND RESET 2.7KΩ LOAD 12 R3 2.7KΩ LOAD R2 R2 R2 LOAD RESET NOTES: 1. VDD = 5.0V ± 0.5V 4. Clock and reset should be brought out separately so they can be toggled before irradiation. 2. R2 = 3.3kΩ, R3 = 47kΩ 5. Group E Sample Size is 2 Die/Wafer. 3. Pins Tied to GND: 1-18, 20, 23, 39 Pins Tied to VCC: 22, 31, 33, 40 Pins With Loads: 24-29, 30, 32, 34-38 Pins Brought Out: 19 (Clock), 21 (Reset) Spec Number 882 518055 HS-80C86RH Intersil Space Level Product Flow - Q 100% Interim Electrical Test 1 (T1) All Lots - Wafer Lot Acceptance (Including SEM) Method 5007 100% Delta Calculation (T0-T1) Each Wafer - GAMMA Radiation Verification, Two samples/wafer, 0 rejects, Method 1019 100% PDA 1, Method 5004 (Note 1) 100% Nondestructive Bond Pull, Method 2023 100% Dynamic Burn-In, Condition D, 240 hours, +125oC or Equivalent Per Method 1015 Sample - Wire Bond Pull Monitor, Method 2011 100% Interim Electrical Test 2 (T2) Sample - Die Shear Monitor, Method 2019 or 2027 100% Delta Calculation (T0-T2) 100% Internal Visual Inspection, Method 2010, Condition A 100% PDA 2, Method 5004 (Note 2) 100% Temperature Cycle - Method 1010, Condition C, 10 cycles 100% Final Electric Test (T3) 100% Fine/Gross Leak, Method 1014 100% Constant Acceleration, Method 2001, Condition Per Method 5004 100% Radiographic, Method 2012 (Note 3) 100% PIND - Method 2020, Condition A 100% External Visual, Method 2009 100% External Visual Sample - Group A, Method 5005 (Note 4) 100% Serialization Sample - Group B, Method 5005 (Note 5) 100% Initial Electrical Test (T0) Sample - Group D, Method 5005 (Notes 5, 6) 100% Static Burn-In 1, Method 1015, Condition A or B, 72 Hours Minimum, 125oC minimum 100% Data Package Generation (Note 6) NOTES: 1. Modified SEM Inspection, not compliant to MIL-STD-883, Method 2018. This device does not meet the Class S minimum metal step coverage of 50%. The metal does meet the current density requirement of <2 E5 A/cm2. Data provided upon request. 2. Failures from subgroups 1, 7 and deltas are used for calculating PDA. The maximum allowable PDA = 5% with no more than 3% of the failures from subgroup 7. 3. Radiographic (X-Ray) inspection may be performed at any point after serialization as allowed by Method 5004. 4. Alternate Group A testing may be performed as allowed by MIL-STD-883, Method 5005. 5. Group B and D inspections are optional and will not be performed unless required by the P.O. When required, the P.O. should include separate line items for Group B test, Group B samples, Group D tests and Group D samples. 6. Group D Generic Data, as defined by MIL-I-38535, is optional and will not be supplied unless required by the P.O. When required, the P.O. should include separate line items for Group D generic data. Generic Data is not guaranteed to be available and is therefore not available in all cases. 7. Data Package Contents: • Cover Sheet (Intersil Name and/or Logo, P.O. Number, Customer Part Number, Lot Date Code, Intersil Part Number, Lot Number, Quantity). Wafer Lot Acceptance Report (Method 5007) to include reproductions of SEM photos with percent of step coverage. • GAMMA Radiation Report. Contains Cover page, disposition, Rad Dose, Lot Number, test package used, specification numbers, test equipment, etc. Radiation Read and Record data on file at Intersil. • X-Ray Report and Film, including penetrameter measurements. • Lot Serial Number Sheet (Good Unit(s) Serial Number and Lot Number). • Variables Data (All Delta operations). Data is identified by serial number. Data header includes lot number and date of test. • Group B and D attributes and/or Generic data is included when required by P.O. • The Certificate of Conformance is a part of the shipping invoice and is not part of Data Book. The Certificate of Conformance is signed by an authorized Quality Representative. Spec Number 883 518055 HS-80C86RH Intersil Space Level Product Flow - 8 100% Interim Electrical Test Each Wafer - GAMMA Radiation Verification, 2 samples/wafer, 0 rejects, Method 1019 100% PDA, Method 5004 (Note 1) 100% Die Attach 100% Final Electric Test Periodic - Wire Bond Pull Monitor, Method 2011 100% Fine/Gross Leak, Method 1014 Periodic - Die Shear Monitor, Method 2019 or 2027 100% External Visual, Method 2009 100% Internal Visual Inspection, Method 2010, Condition B Sample - Group A, Method 5005 (Note 2) CSI and/or GSI PreCap (Note 5) Sample - Group B, Method 5005 (Note 3) 100% Temperature Cycle, Method 1010, Condition C, 10 cycles Sample - Group C, Method 5005 (Notes 3, 4) 100% Constant Acceleration, Method 2001, Condition Per Method 5004 100% External Visual Sample - Group D, Method 5005 (Notes 3, 4) 100% Data Package Generation (Note 6) CSI and/or GSI Final (Note 5) 100% Initial Electrical Test 100% Dynamic Burn-In, Condition D, 160 hours, +125oC, or Equivalent, Per Method 1015 NOTES: 1. Failures from subgroups 1, 7 are used for calculating PDA. The maximum allowable PDA = 5%. 2. Alternate Group A testing may be performed as allowed by MIL-STD-883, Method 5005 may be performed. 3. Group B, C, and D inspections are optional and will not be performed unless required by the P.O. When required, the P.O. should include separate line items for Group B Test, Group C Test, Group C Samples, Group D Test and Group D Samples. 4. Group C and/or Group D Generic Data, as defined by MIL-I-38535, is optional and will not be supplied unless required by the P.O. When required, the P.O. should include separate line items for Group D generic data. Generic Data is not guaranteed to be available and is therefore not available in all cases. 5. CSI and /or GSI inspections are optional and will not be performed unless required by the P.O. When required, the P.O. should include separate line items for CSI PreCap inspection, CSI final inspection, GSI PreCap inspection, and/or GSI final inspection. 6. Data Package Contents: • Cover Sheet (Intersil Name and/or Logo, P.O. Number, Customer Part Number, Lot Date Code, Intersil Part Number, Lot Number, Quantity). • GAMMA Radiation Report. Contains Cover page, disposition, RAD Dose, Lot Number, test package used, specification numbers, test equipment, etc. Radiation Read and Record data on file at Intersil. • Screening, Electrical, and Group A attributes (Screening attributes begins at Initial Electrical Test). • Group B, C and D attributes and/or Generic data is included when required by P.O. • Variables Data (All Delta operations) Data is identified by serial number. Data header includes lot number and date of test. • Group B and D attributes and/or Generic data is included when required by P.O. • The Certificate of Conformance is a part of the shipping invoice and is not part of Data Book. The Certificate of Conformance is signed by an authorized Quality Representative. Spec Number 884 518055 HS-80C86RH Metallization Topology DIE DIMENSIONS: 6370µm x 7420µm x 485µm GLASSIVATION: Thickness: 8kÅ ±1kÅ METALLIZATION: Type: Al/S Thickness: 11kÅ ±2kÅ WORST CASE CURRENT DENSITY: <2 x 105A/cm2 Metallization Mask Layout (37) A17/S4 (38) AD16 (39) AD15 (40) VCC (1) GND (2) AD14 (3) AD13 (4) AD12 (5) AD11 HS-80C86RH (36) A18/S5 (35) A19/S6 AD10 (6) AD9 (7) (34) BHE/S7 (33) MN/MX AD8 (8) (32) RD AD7 (9) (31) RQ/GT0 AD6 (10) AD5 (11) (30) RQ/GT1 AD4 (12) (29) LOCK AD3 (13) (28) S2 AD2 (14) (27) S1 AD1 (15) QS0 (25) QSI (21) TEST (23) READY (22) RESET (21) GND (20) CLK (19) INTR (18) AD0 (16) NMI (17) (26) S0 Spec Number 885 518055 HS-80C86RH Instruction Set Summary INSTRUCTION CODE MNEMONIC AND DESCRIPTION 76543210 76543210 76543210 76543210 Register/Memory to/from Register 100010dw mod reg r/m Immediate to Register/Memory 1100011w mod 0 0 0 r/m data data if w 1 DATA TRANSFER MOV = MOVE: Immediate to Register 1 0 1 1 w reg data data if w 1 Memory to Accumulator 1010000w addr-low addr-high Accumulator to Memory 1010001w addr-low addr-high Register/Memory to Segment Register †† 10001110 mod 0 reg r/m Segment Register to Register/Memory 10001100 mod 0 reg r/m 11111111 mod 1 1 0 r/m PUSH = Push: Register/Memory Register Segment Register 0 1 0 1 0 reg 0 0 0 reg 1 1 0 POP = Pop: Register/Memory Register Segment Register 10001111 mod 0 0 0 r/m 0 1 0 1 1 reg 0 0 0 reg 1 1 1 XCHG = Exchange: Register/Memory with Register Register with Accumulator 1000011w mod reg r/m 1 0 0 1 0 reg IN = Input from: Fixed Port 1110010w Variable Port 1110110w port OUT = Output to: Fixed Port 1110011w Variable Port 1110111w port XLAT = Translate Byte to AL 11010111 LEA = Load EA to Register2 10001101 mod reg r/m LDS = Load Pointer to DS 11000101 mod reg r/m LES = Load Pointer to ES 11000100 mod reg r/m LAHF = Load AH with Flags 10011111 SAHF = Store AH into Flags 10011110 PUSHF = Push Flags 10011100 POPF = Pop Flags 10011101 Spec Number 886 518055 HS-80C86RH Instruction Set Summary (Continued) INSTRUCTION CODE MNEMONIC AND DESCRIPTION 76543210 76543210 76543210 76543210 data if s:w = 01 ARITHMETIC ADD = Add: Register/Memory with Register to Either 000000dw mod reg r/m Immediate to Register/Memory 100000sw mod 0 0 0 r/m data Immediate to Accumulator 0000010w data data if w = 1 ADC = Add with Carry: Register/Memory with Register to Either 000100dw mod reg r/m Immediate to Register/Memory 100000sw mod 0 1 0 r/m data Immediate to Accumulator 0001010w data data if w = 1 1111111w mod 0 0 0 r/m data if s:w = 01 INC = Increment: Register/Memory Register 0 1 0 0 0 reg AAA = ASCll Adjust for Add 00110111 DAA = Decimal Adjust for Add 00100111 SUB = Subtract: Register/Memory and Register to Either 001010dw mod reg r/m Immediate from Register/Memory 100000sw mod 1 0 1 r/m data Immediate from Accumulator 0010110w data data if w = 1 Register/Memory and Register to Either 000110dw mod reg r/m Immediate from Register/Memory 100000sw mod 0 1 1 r/m data Immediate from Accumulator 0001110w data data if w = 1 1111111w mod 0 0 1 r/m data if s:w = 01 SBB = Subtract with Borrow data if s:w = 01 DEC = Decrement: Register/Memory Register NEG = Change Sign 0 1 0 0 1 reg 1111011w mod 0 1 1 r/m Register/Memory and Register 001110dw mod reg r/m Immediate with Register/Memory 100000sw mod 1 1 1 r/m data Immediate with Accumulator 0011110w data data if w = 1 AAS = ASCll Adjust for Subtract 00111111 DAS = Decimal Adjust for Subtract 00101111 MUL = Multiply (Unsigned) 1111011w mod 1 0 0 r/m IMUL = Integer Multiply (Signed) 1111011w mod 1 0 1 r/m AAM = ASCll Adjust for Multiply 11010100 00001010 DlV = Divide (Unsigned) 1111011w mod 1 1 0 r/m IDlV = Integer Divide (Signed) 1111011w mod 1 1 1 r/m AAD = ASClI Adjust for Divide 11010101 00001010 CBW = Convert Byte to Word 10011000 CWD = Convert Word to Double Word 10011001 CMP = Compare: data if s:w = 01 Spec Number 887 518055 HS-80C86RH Instruction Set Summary (Continued) INSTRUCTION CODE MNEMONIC AND DESCRIPTION 76543210 76543210 1111011w mod 0 1 0 r/m 76543210 76543210 data if w = 1 LOGIC NOT = Invert SHL/SAL = Shift Logical/Arithmetic Left 110100vw mod 1 0 0 r/m SHR = Shift Logical Right 110100vw mod 1 0 1 r/m SAR = Shift Arithmetic Right 110100vw mod 1 1 1 r/m ROL = Rotate Left 110100vw mod 0 0 0 r/m ROR = Rotate Right 110100vw mod 0 0 1 r/m RCL = Rotate Through Carry Flag Left 110100vw mod 0 1 0 r/m RCR = Rotate Through Carry Right 110100vw mod 0 1 1 r/m AND = And: Reg./Memory and Register to Either 0010000dw mod reg r/m Immediate to Register/Memory 1000000w mod 1 0 0 r/m data Immediate to Accumulator 0010010w data data if w = 1 TEST = And Function to Flags, No Result: Register/Memory and Register 1000010w mod reg r/m Immediate Data and Register/Memory 1111011w mod 0 0 0 r/m data Immediate Data and Accumulator 1010100w data data if w = 1 data if w = 1 OR = Or: Register/Memory and Register to Either 000010dw mod reg r/m Immediate to Register/Memory 1000000w mod 1 0 1 r/m data Immediate to Accumulator 0000110w data data if w = 1 data if w = 1 XOR = Exclusive or: Register/Memory and Register to Either 001100dw mod reg r/m Immediate to Register/Memory 1000000w mod 1 1 0 r/m data Immediate to Accumulator 0011010w data data if w = 1 disp-high data if w = 1 STRING MANIPULATION REP = Repeat 1111001z MOVS = Move Byte/Word 1010010w CMPS = Compare Byte/Word 1010011w SCAS = Scan Byte/Word 1010111w LODS = Load Byte/Word to AL/AX 1010110w STOS = Stor Byte/Word from AL/A 1010101w CONTROL TRANSFER CALL = Call: Direct Within Segment 11101000 disp-low Indirect Within Segment 11111111 mod 0 1 0 r/m Direct Intersegment 10011010 offset-low offset-high seg-low seg-high Indirect Intersegment 11111111 mod 0 1 1 r/m Spec Number 888 518055 HS-80C86RH Instruction Set Summary (Continued) INSTRUCTION CODE MNEMONIC AND DESCRIPTION 76543210 76543210 76543210 Direct Within Segment 11101001 disp-low disp-high Direct Within Segment-Short 11101011 disp Indirect Within Segment 11111111 mod 1 0 0 r/m Direct Intersegment 11101010 offset-low offset-high Direct Intersegment 11101010 offset-low offset-high seg-low seg-high Indirect Intersegment 11111111 mod 1 0 1 r/m 76543210 JMP = Unconditional Jump: RET = Return from CALL: Within Segment 11000011 Within Seg Adding lmmed to SP 11000010 Intersegment 11001011 Intersegment Adding Immediate to SP data-low data-high 11001010 data-low data-high JE/JZ = Jump on Equal/Zero 01110100 disp JL/JNGE = Jump on Less/Not Greater or Equal 01111100 disp JLE/JNG = Jump on Less or Equal/ Not Greater 01111110 disp JB/JNAE = Jump on Below/Not Above or Equal 01110010 disp JBE/JNA = Jump on Below or Equal/Not Above 01110110 disp JP/JPE = Jump on Parity/Parity Even 01111010 disp JO = Jump on Overtlow 01110000 disp JS = Jump on Sign 01111000 disp JNE/JNZ = Jump on Not Equal/Not Zero 01110101 disp JNL/JGE = Jump on Not Less/Greater or Equal 01111101 disp JNLE/JG = Jump on Not Less or Equal/Greater 01111111 disp JNB/JAE = Jump on Not Below/Above or Equal 01110011 disp JNBE/JA = Jump on Not Below or Equal/Above 01110111 disp JNP/JPO = Jump on Not Par/Par Odd 01111011 disp JNO = Jump on Not Overflow 01110001 disp JNS = Jump on Not Sign 01111001 disp LOOP = Loop CX Times 11100010 disp LOOPZ/LOOPE = Loop While Zero/Equal 11100001 disp LOOPNZ/LOOPNE = Loop While Not Zero/Equal 11100000 disp JCXZ = Jump on CX Zero 11100011 disp Type Specified 11001101 type Type 3 11001100 INTO = Interrupt on Overflow 11001110 IRET = Interrupt Return 11001111 INT = Interrupt Spec Number 889 518055 HS-80C86RH Instruction Set Summary (Continued) INSTRUCTION CODE MNEMONIC AND DESCRIPTION 76543210 76543210 76543210 76543210 PROCESSOR CONTROL CLC = Clear Carry 11111000 CMC = Complement Carry 11110101 STC = Set Carry 11111001 CLD = Clear Direction 11111100 STD = Set Direction 11111101 CLl = Clear Interrupt 11111010 ST = Set Interrupt 11111011 HLT = Halt 11110100 WAIT = Wait 10011011 ESC = Escape (to External Device) 11011xxx LOCK = Bus Lock Prefix 11110000 NOTES: AL = 8-bit accumulator AX = 16-bit accumulator CX = Count register DS= Data segment ES = Extra segment Above/below refers to unsigned value. Greater = more positive; Less = less positive (more negative) signed values if d = 1 then “to” reg; if d = 0 then “from” reg if w = 1 then word instruction; if w = 0 then byte instruction if mod = 11 then r/m is treated as a REG field if mod = 00 then DISP = O†, disp-low and disp-high are absent if mod = 01 then DISP = disp-low sign-extended 16-bits, disp-high is absent if mod = 10 then DISP = disp-high:disp-low if r/m = 000 then EA = (BX) + (SI) + DISP if r/m = 001 then EA = (BX) + (DI) + DISP if r/m = 010 then EA = (BP) + (SI) + DISP if r/m = 011 then EA = (BP) + (DI) + DISP if r/m = 100 then EA = (SI) + DISP if r/m = 101 then EA = (DI) + DISP if r/m = 110 then EA = (BP) + DISP † if r/m = 111 then EA = (BX) + DISP DISP follows 2nd byte of instruction (before data if required) † except if mod = 00 and r/m = 110 then EA = disp-high: disp-low. †† MOV CS, REG/MEMORY not allowed. mod x x x r/m if s:w = 01 then 16 bits of immediate data form the operand. if s:w. = 11 then an immediate data byte is sign extended to form the 16-bit operand. if v = 0 then “count” = 1; if v = 1 then “count” in (CL) x = don't care z is used for string primitives for comparison with ZF FLAG. SEGMENT OVERRIDE PREFIX 001 reg 11 0 REG is assigned according to the following table: 16-BIT (w = 1) 8-BIT (w = 0) SEGMENT 000 AX 000 AL 00 ES 001 CX 001 CL 01 CS 010 DX 010 DL 10 SS 011 BX 011 BL 11 DS 100 SP 100 AH 00 ES 101 BP 101 CH 00 ES 110 SI 110 DH 00 ES 111 DI 111 BH 00 ES Instructions which reference the flag register file as a 16-bit object use the symbol FLAGS to represent the file: FLAGS = X:X:X:X:(OF):(DF):(IF):(TF):(SF):(ZF):X:(AF):X:(PF):X:(CF) Mnemonics Intel, 1978 Spec Number 890 518055 HS-80C86RH Ceramic Dual-In-Line Metal Seal Packages (SBDIP) -A- D40.6 MIL-STD-1835 CDIP2-T40 (D-5, CONFIGURATION C) 40 LEAD CERAMIC DUAL-IN-LINE METAL SEAL PACKAGE LEAD FINISH c1 -D- BASE METAL E b1 M (b) M -Bbbb S C A - B S INCHES (c) SECTION A-A D S D BASE PLANE S2 Q -C- SEATING PLANE A L S1 eA A A b2 b e ccc M C A - B S D S eA/2 c aaa M C A - B S D S SYMBOL MIN MAX MIN MAX NOTES A - 0.225 - 5.72 - b 0.014 0.026 0.36 0.66 2 b1 0.014 0.023 0.36 0.58 3 b2 0.045 0.065 1.14 1.65 - b3 0.023 0.045 0.58 1.14 4 c 0.008 0.018 0.20 0.46 2 c1 0.008 0.015 0.20 0.38 3 D - 2.096 E 0.510 0.620 1. Index area: A notch or a pin one identification mark shall be located adjacent to pin one and shall be located within the shaded area shown. The manufacturer’s identification shall not be used as a pin one identification mark. 2. The maximum limits of lead dimensions b and c or M shall be measured at the centroid of the finished lead surfaces, when solder dip or tin plate lead finish is applied. 12.95 53.24 4 15.75 4 e 0.100 BSC 2.54 BSC - eA 0.600 BSC 15.24 BSC - eA/2 NOTES: MILLIMETERS 0.300 BSC 7.62 BSC - L 0.125 0.200 3.18 5.08 - Q 0.015 0.070 0.38 1.78 5 S1 0.005 - 0.13 - 6 S2 0.005 - 0.13 - 7 α 90o 105o 90o 105o - aaa - 0.015 - 0.38 - 3. Dimensions b1 and c1 apply to lead base metal only. Dimension M applies to lead plating and finish thickness. bbb - 0.030 - 0.76 - ccc - 0.010 - 0.25 - 4. Corner leads (1, N, N/2, and N/2+1) may be configured with a partial lead paddle. For this configuration dimension b3 replaces dimension b2. M - 0.0015 - 0.038 2 N 40 40 8 Rev. 0 4/94 5. Dimension Q shall be measured from the seating plane to the base plane. 6. Measure dimension S1 at all four corners. 7. Measure dimension S2 from the top of the ceramic body to the nearest metallization or lead. 8. N is the maximum number of terminal positions. 9. Braze fillets shall be concave. 10. Dimensioning and tolerancing per ANSI Y14.5M - 1982. 11. Controlling dimension: INCH. Spec Number 891 518055 HS-80C86RH Ceramic Metal Seal Flatpack Packages (Flatpack) E 1 K42.A TOP BRAZED 42 LEAD CERAMIC METAL SEAL FLATPACK PACKAGE N e INCHES A A D b E1 S1 L C A Q E2 c1 LEAD FINISH MIN MAX MIN MAX NOTES A - 0.100 - 2.54 - b 0.017 0.025 0.43 0.64 - b1 0.017 0.023 0.43 0.58 - c 0.007 0.013 0.18 0.33 - c1 0.007 0.010 0.18 0.25 3 D 1.045 1.075 26.54 27.31 E 0.630 0.650 16.00 16.51 - E1 - 0.680 17.27 3 E2 0.530 0.550 e BASE METAL (c) b1 M M (b) 13.46 0.050 BSC 13.97 - 1.27 BSC 11 k - - - - L 0.320 0.350 8.13 8.89 - Q 0.045 0.065 1.14 1.65 8 S1 0.000 - 0.00 - 6 M - 0.0015 - 0.04 N SECTION A-A MILLIMETERS SYMBOL 42 - - 42 Rev. 0 6/17/94 NOTES: 1. Index area: A notch or a pin one identification mark shall be located adjacent to pin one and shall be located within the shaded area shown. The manufacturer’s identification shall not be used as a pin one identification mark. Alternately, a tab (dimension k) may be used to identify pin one. 6. Measure dimension S1 at all four corners. 7. For bottom-brazed lead packages, no organic or polymeric materials shall be molded to the bottom of the package to cover the leads. 8. Dimension Q shall be measured at the point of exit (beyond the meniscus) of the lead from the body. Dimension Q minimum shall be reduced by 0.0015 inch (0.038mm) maximum when solder dip lead finish is applied. 2. If a pin one identification mark is used in addition to a tab, the limits of dimension k do not apply. 3. This dimension allows for off-center lid, meniscus, and glass overrun. 9. Dimensioning and tolerancing per ANSI Y14.5M - 1982. 4. Dimensions b1 and c1 apply to lead base metal only. Dimension M applies to lead plating and finish thickness. The maximum limits of lead dimensions b and c or M shall be measured at the centroid of the finished lead surfaces, when solder dip or tin plate lead finish is applied. 5. N is the maximum number of terminal positions. 10. Controlling dimension: INCH. 11. The basic lead spacing is 0.050 inch (1.27mm) between center lines. Each lead centerline shall be located within ±0.005 inch (0.13mm) of its exact longitudinal position relative to lead 1 and the highest numbered (N) lead. All Intersil semiconductor products are manufactured, assembled and tested under ISO9000 quality systems certification. Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries. For information regarding Intersil Corporation and its products, see web site http://www.intersil.com Sales Office Headquarters NORTH AMERICA Intersil Corporation P. O. Box 883, Mail Stop 53-204 Melbourne, FL 32902 TEL: (407) 724-7000 FAX: (407) 724-7240 EUROPE Intersil SA Mercure Center 100, Rue de la Fusee 1130 Brussels, Belgium TEL: (32) 2.724.2111 FAX: (32) 2.724.22.05 ASIA Intersil (Taiwan) Ltd. Taiwan Limited 7F-6, No. 101 Fu Hsing North Road Taipei, Taiwan Republic of China TEL: (886) 2 2716 9310 FAX: (886) 2 2715 3029 Spec Number 892 518055