HW HWS400

HWS400
April 2004
Features
QFN12L (3 x 3 mm)
•
• High Isolation: 55 dB @ 870 MHz
• 50 or 75 Ohm Systems
• Low DC Power Consumption
• Miniature QFN12L (3x3 mm) Plastic Package
Description
The HWS400 is a GaAs MMIC SPDT terminated
(non-reflective) switch in a low cost QFN12L (3x3
mm) plastic package and can be used in both 50
ohm and 75 ohm systems. The HWS400 features
low insertion loss and high isolation with very low
DC
power
consumption.
Typical
applications
include CATV and basestation systems for either
SPDT or SPST functions.
Electrical Specifications at 25°C with 0, +5V Control Voltages, 50 Ohm system
Parameter
Insertion Loss
Isolation
Test Conditions
Min.
Typ.
Max.
Unit
0.9
dB
dB
dB
DC-870 MHz
870-1000 MHz
1000-2000 MHz
0.5
0.6
0.6
DC-870 MHz
870-1000 MHz
1000-2000 MHz
55
53
39
dB
dB
dB
36
Return Loss
DC-2000 MHz
18
dB
Input Power for One dB
Compression
500-2000 MHz
28
dBm
Input Third Order Intermodulation
Intercept Point
500-2000 MHz
48
dBm
Switching Time
50
ns
Control Current
30
300
uA
Note: All measurements made in a 50 ohm system with 0/+5V control voltages, unless otherwise specified.
Hexawave Inc.
2 Prosperity Road II, Science Park, Hsinchu, Taiwan. TEL 886-3-578-5100 FAX 886-3-577-0512
http://www.hw.com.tw
All specifications are subject to change without notice.
V2
HWS400
April 2004
Typical Performance Data, 50 Ohm
System @ +25°C
Typical Performance Data, 75 Ohm
System @ +25°C
Insertion Loss vs Frequency
-0.2
-0.2
-0.3
-0.3
-0.4
-0.4
Insertion Loss(dB)
Insertion Loss(dB)
Insertion Loss vs Frequency
-0.5
-0.6
-0.7
-0.8
-0.9
0.0
0.5
1.0
1.5
Frequency(GHz)
2.0
-0.6
-0.7
-0.8
-1.0
2.5
0.0
0.5
1.0
1.5
Frequency(GHz)
2.0
2.5
2.0
2.5
Isolation vs Frequency
Isolation vs Frequency
-30
-30
-35
-35
-40
-40
-45
Isolation(dB)
Isolation(dB)
-0.5
-0.9
-1.0
-50
-55
-60
-65
-70
-75
-80
-45
-50
-55
-60
-65
-70
-75
-80
0.0
0.5
1.0
1.5
Frequency(GHz)
2.0
2.5
0
RFC
RF1, RF2 Off
-5
0.0
0.5
1.0
1.5
Frequency(GHz)
Return Loss vs Frequency
Return Loss vs Frequency
0
RF1, RF2 On
RFC
RF1, RF2 Off
-5
RF1, RF2 On
-10
-10
Return Loss (dB)
Return Loss (dB)
V2
-15
-15
-20
-20
-25
-25
-30
-30
-35
-35
-40
-40
0.0
0.5
Hexawave Inc.
1.0
1.5
Frequency (GHz)
2.0
2.5
0.0
0.5
1.0
1.5
Frequency (GHz)
2.0
2 Prosperity Road II, Science Park, Hsinchu, Taiwan. TEL 886-3-578-5100 FAX 886-3-577-0512
http://www.hw.com.tw
All specifications are subject to change without notice.
2.5
HWS400
April 2004
Absolute Maximum Ratings
Parameter
Logic Table for Switch On-Path
Absolute Maximum
RF Input Power
+32 dBm @ +5V
Control Voltage
+6V
Operating Temperature
-40°C to +85°C
Storage Temperature
-65°C to +150°C
Pin Out (Top View)
VC1
VC2
RFC-RF1
RFC-RF2
0
1
Insertion Loss
Isolation
1
0
Isolation
Insertion Loss
‘1’ = +3V to +5V
‘0’ = 0V to +0.2V
%
%
12
11
10
2
8
3
7
5
6
&
4
&
9
&
1
Exposed pad in the bottom must be connected to
ground by via holes.
Application Circuit
%
$
%
#
!
$
"
"
$
$
#
$
$
!
Note:
1. 0402 size components are recommended.
2. Capacitance values for C1, C2, C3, and C4 are critical
for isolation performance.
Hexawave Inc.
V2
2 Prosperity Road II, Science Park, Hsinchu, Taiwan. TEL 886-3-578-5100 FAX 886-3-577-0512
http://www.hw.com.tw