General Purpose Relays Force Guided Relays SCHRACK Force Guided Relay SR2M n2 pole relay with force guided contacts according to EN 50205 insulation between poles nReinforced Typical applications Emergency shut-off, press control, machine control, elevator and escalator control, safety relays F0188-D VZT Approvals Coil Data (contunied) Technical data of approved types on request Coil versions, DC-coil Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ω±10%1) mW 015 15 11.3 1.5 321 701 018 18 13.5 1.8 483 671 021 21 16 2.1 630 700 024 24 18 2.4 823 700 036 36 27 3.6 1851 700 040 40 30 4.0 2286 700 048 48 36 4.8 32911) 700 060 60 45 6 51421) 700 080 85 63.8 8.5 91431) 790 110 110 83 11 172851) 700 VDE 116064, UL E214025, TUV 968/EZ 111, CQC0617015579 Contact Data Contact arrangement 1 form A + 1 form B contacts (1 NO + 1 NC) or 2 form C contacts (2 CO) According EN50205 only 1NO / 1NC (11-14 and 22-21 or 12-11 and 21-24) shall be used as force guided contacts. Rated voltage 250VAC Max. switching voltage 400VAC Rated current 6A Contact material AgNi Contact style single contact, force guided 1 form A + B, 1 NO + 1NC type A according to EN 50205 2 form C, 2CO type B according to EN 50205 Min. recommended contact load 5V/10mA Initial contact resistance ≤100mΩ at 1A, 24VDC ≤20Ω at 10mA, 5VDC Frequency of operation, with/without load 6/300min-1 Contact ratings, IEC60947-5-1, on 1 form A (NO) contact AC15-3A DC13-6A Mechanical endurance 10x106 operations 1) Coil resistance ±12%. All figures are given for coil without pre-energization, at ambient temperature +23°C. Insulation Coil Data Coil voltage range 5 to 110VDC Coil versions, DC-coil Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ω±10%1) mW 005 5 3.8 0.5 35.7 700 006 6 4.5 0.6 51 706 009 9 6.8 0.9 116 698 012 12 9 1.2 206 699 04-2011, Rev. 0411 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between open contacts between contact and coil between adjacent contacts Insulation to EN 50178, type of insulation between contact and coil between adjacent contacts Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions 1500Vrms 4000Vrms 3000Vrms microdisconnection ≥8/8mm ≥5.5/5.5mm reinforced reinforced Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 1 General Purpose Relays Force Guided Relays SCHRACK Force Guided Relay SR2M (Continued) Other Data Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at www.te.com/customersupport/rohssupportcenter Ambient temperature -25 to 70°C Category of environmental Protection IEC 61 810 RTIII Weight 20g Resistance to soldering heat THT IEC 60068-2-20 260°C/5s Packaging/unit tube/20 pcs. PCB layout / terminal assignment Bottom view on solder pins 2 form C, 2 CO contacts For more detailed information see product specification 2158001 S0163-CO S0163-BJ Dimensions 1 form A + 1 form B contacts, 1 NO + 1 NC S0163_CU S0273-BB S0163-CV 2 04-2011, Rev. 0411 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. General Purpose Relays Force Guided Relays SCHRACK Force Guided Relay SR2M (Continued) Product code structure Typical product code V23047 -A1 012 -A 5 11 Type V23047 Relay with force guided contacts SR2M Version A1 standard Coil Coil code: please refer to coil versions table (e.g. 024=24VDC) Contact set A single contact Contact material 5 AgNi Contact configuration 01 2 form C contacts (2 CO) 11 1 form A + 1 form B contacts ( 1 NO + 1 NC) Other types on request Product code Version Cont. material Contact arrangement Coil V23047-A1005-A501 Standard AgNi 2 form C (CO) 5VDC V23047-A1005-A511 wash tight 1 A + 1 B, (1 NO + 1 NC) V23047-A1006-A501 2 form C (CO) 6VDC V23047-A1006-A511 1 A + 1 B, (1 NO + 1 NC) V23047-A1009-A501 2 form C (CO) 9VDC V23047-A1009-A511 1 A + 1 B, (1 NO + 1 NC) V23047-A1012-A501 2 form C (CO) 12VDC V23047-A1012-A511 1 A + 1 B, (1 NO + 1 NC) V23047-A1018-A501 2 form C (CO) 18VDC V23047-A1018-A511 1 A + 1 B, (1 NO + 1 NC) V23047-A1021-A501 2 form C (CO) 21VDC V23047-A1021-A511 1 A + 1 B, (1 NO + 1 NC) V23047-A1024-A501 2 form C (CO) 24VDC V23047-A1024-A511 1 A + 1 B, (1 NO + 1 NC) V23047-A1036-A501 2 form C (CO) 36VDC V23047-A1036-A511 1 A + 1 B, (1 NO + 1 NC) V23047-A1040-A501 2 form C (CO) 40VDC V23047-A1040-A511 1 A + 1 B, (1 NO + 1 NC) V23047-A1048-A501 2 form C (CO) 48VDC V23047-A1048-A511 1 A + 1 B, (1 NO + 1 NC) V23047-A1060-A511 60VDC V23047-A1110-A501 2 form C (CO) 110VDC V23047-A1110-A511 1 A + 1 B, (1 NO + 1 NC) 04-2011, Rev. 0411 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Part number 1393258-2 7-1415006-1 3-1415011-1 6-1415011-1 1393258-3 7-1415011-1 1393258-4 1393258-5 1393258-8 1393258-9 1-1393258-1 1-1393258-2 1-1393258-5 1-1393258-7 2-1393258-0 8-1415011-1 2-1393258-1 2-1393258-2 3-1415006-1 9-1415011-1 2-1393258-3 1-1415012-1 2-1415012-1 Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 3