INTEGRAL ILMS5380 MICROCIRCUIT FOR REMOTE CONTROL SYSTEMS Description Microcircuit is mini photomodule designed for IR signal reception in remote control systems. Photomodule output signal can be decode directly by microprocessor. Advantage is resistant functioning and protection from uncontrolled output impulse. Characteristic: • Photodiode and preamplifier in one frame • Inside band-pass filter for subcarrier frequency (PCM) of 38 Hz • Frame material protects from daylight exposure • Special screen protects from external electric fields exposure • Supply voltage 5V • ТТL and CMOS compability Block diagram Korzhenevskogo 12, Minsk, 220108, Republic of Belarus Fax: +375 (17) 278 28 22, Phone: +375 (17) 278 07 11, 212 24 70, 212 24 61, 212 69 16 E-mail: [email protected] URL: www.bms.by ILMS5380 Limiting parameters values Tamb=25°C Title Measurements condition Supply voltage Power current Transition temperature Storage temperature Operating temperature Power consumption Notation Meaning Vs Is 4.5 ÷ 5.5 0.8 100 -25.÷.+85 -25 ÷+85 50 TJ Tstg Tamb Ptot (Tamb = 85 °C) Measu r-ement unit W мА °C °C °C mW Basic characteristics Tamb=25°C Title Current (Output 2) Current (Output 2) Measurements conditions consumtion Vs = 5 V, Ev = 0 consumption Vs = 5 V, Ev = 40 klx, sun light Transmission distance Ev = 0, test signal, IR-diode TSIP5201, lp = 1.5 A Output voltage of low level IOSL = 0.5 мА, Ее = 0.5 mW/M2, (Output 3) f=fo,tPI/N=0,4 Test signal Minimum density of IR- tPO=tPI ±160 мкс radiating power* Test signal Maximum radiation Test signal Notation MIN TYP MAX Measuremet unit. mA ISD 0.4 0.5 0.8 ISH - 1.0 - mA d - 32 - m VOSL - - 250 Eemin 0.6 0.4 - Eemax - - 20 mW mW/m2 W/m2 * - accordance with customer order programming of subcarrier frequency can be fulfilled (PCM) FO in range of(36-40) кHz Сircuit connection. ILMS5360 330 Ω 2 + 5V 4.7 µ F*) 3 ∗) > 10κΩ opflonal 1 µC + 5V *) - it is necessary only for power source interference suppression + 5V. Korzhenevskogo 12, Minsk, 220108, Republic of Belarus Fax: +375 (17) 278 28 22, Phone: +375 (17) 278 07 11, 212 24 70, 212 24 61, 212 69 16 E-mail: [email protected] URL: www.bms.by ILMS5380 Input test signal E0 ~ ~ ~ ~ t tPI=1/F0 tPI T=2,5 tPI Input signal V0 tPO=tPI+ 160 mcs V0H V0L 100 t Erel, % Srel, % 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 f/f0 0 0.75 0.8 0.9 1.0 1.1 1.2 Figure 1 – Dependence of sensitivity as function of normalized frequency, Tamb = 25°C (amplitude-frequency response). λ, mkm 0 0.65 0.7 0.8 0.9 1.0 1.1 Figure 2 – Dependence of sensitivity on IRradiation wave length by Tamb = 25°C (spectral response). Korzhenevskogo 12, Minsk, 220108, Republic of Belarus Fax: +375 (17) 278 28 22, Phone: +375 (17) 278 07 11, 212 24 70, 212 24 61, 212 69 16 E-mail: [email protected] URL: www.bms.by ILMS5380 Eemin, mW/m2 0.5 0.4 0.3 0.2 0.1 -30 0 30 60 90 Tamb, °C Figure 3 – Dependence of IR radiation minimum power density parameter on environment temperature (microcircuit sensibility) by Us = 5В. а) vertical direction b) horizontal direction Figure 4 – Dependence of relative sensitivity on infra-red source angle turn. Korzhenevskogo 12, Minsk, 220108, Republic of Belarus Fax: +375 (17) 278 28 22, Phone: +375 (17) 278 07 11, 212 24 70, 212 24 61, 212 69 16 E-mail: [email protected] URL: www.bms.by