Catalog 1308242 Issued 3-03 AGASTAT 2100 series Miniature Electropneumatic Timing Relay Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Design Features • High Repeat Accuracy over voltage and temperature extremes • Hermetically sealed units are designed for high shock and vibration applications • Instant recycling – easy linear adjustment • Exclusive Dial Head adjustment – no needle valves • Delay ranges from milliseconds to 3 minutes • DPDT contacts Design & Construction Sealed patented timing head circulates air under controlled pressure through a variable orifice to provide adjustable timing. Circular-path Dial Head principle replaces traditional needle valve. Snap-action switch assembly provides sustained contact pressure during timing cycles. Specially designed over center mechanism assures flutterfree load transfer after extended delay periods. Precision-wound solenoid assembly supplies the basic motive force when the control circuit is closed. These assemblies are mounted in a rigid self-supporting framework within a steel enclosure. This rugged construction assures permanent alignment of all operating members, the key to this unit's long trouble-free operation. Operation Series 2112 (On-Delay) - Applying rated voltage to the solenoid coil starts the preset time delay. At the end of the delay period the NC contacts break and the NO contacts make. Contacts remain in this position until the coil is deenergized, when the switch instantaneously returns to its original position. De-energizing the coil, either during or after the delay period, will immediately (within 25 msec.) recycle the unit. It will then provide another full delay period on re-energization. Series 2122 (Off-Delay) - Applying rated voltage to the coil for at least 75 msec. (for accurate timing) will instantaneously transfer the switch, breaking the NC contacts and making the NO contacts. Contacts remain in this position as long as the coil is energized. The preset time delay period begins as soon as the coil is de-energized, at the end of which the switch returns to its original position. No power is required during the timing period. Reenergizing the coil, either during or after the delay period, will immediately start a new cycle with full delay period. Repeat Accuracy: NORMAL VERTICAL POSITION +5% at 25°C; +7% at 85°C; +8% at -55°C. The average time between -55°C and 85°C will be within +20% of the average @ 25°C with a proportionally reduced effect at lesser extremes. In extremely short delay settings an additional 8 msec. variation may result on AC models due to "half cycle" alternating current effect. Setting Tolerance: Factory time setting, when specified, subject to additional +5% tolerance. Position Sensitivity: HORIZONTAL POSITION: Approximately 5% increase from the initial time in the vertical position. INVERTED POSITION: Approximately 10% increase from the initial time in the vertical position. Reset Time: 2112 Series: 25 msec.; 2122 Series: 75 msec. Relay Release Time: 25 msec. (2112 Series) Relay Operate Time: 75 msec. (2122 Series) Operating Voltage: Coil Data Nominal Resistance Operating Ohms Code Voltage ±10% M N P R Y 12VDC 28VDC 48VDC 110VDC 125VDC Code 30 131 500 3200 3380 S S T U Nominal Operating Voltage Resistance Ohms ±10% 120V 60 Hz 190 (2112 Series) 120V 60Hz 285 (2122 Series) 240V 60Hz 765 115V 400Hz 2600 Transients: Insensitive to transients of +1500 VAC for 10 milliseconds Dielectric: 1000V RMS @ 60Hz between non-connected terminals. Contact Rating (DPDT Contacts): 30V DC 110V DC 120V 60Hz 120V 400Hz 240V 60Hz Inductive (Amps) 2 .75 3 2 1.5 Resistive (Amps) 10 1 10 10 5 Based on 100,000 operations electrical, 1,000,000 mechanical. Inductive and capacitive load should not have inrush currents that exceed five times normal operating load. Ambient Temperature Range: -55°C to +85°C Weight: Maximum, any unit - 17 ozs. Mounting/Terminals: Chassis mounting tabs, octal plugs and external (-4) or internal (-5) adjustment. Panel mounting back plate, internal adjustment, and solder hook terminals (-9). Operation (Listed values at nom. voltage, 25°C unless noted). Operating Mode: 2112: On-delay (delay on pull-in); 2122: Off-delay (delay on drop-out) Timing Adjustment: All standard models offer easy linear adjustment over one of nine timing ranges listed below. For applications requiring frequent readjustment, the external knob model with calibrated dial is recommended. For tamper-proof installation or where readjustment is infrequent, the internal key model may be preferred. This model requires removal of the cover plate for timing adjustment. Hermetically sealed models provide a slotted adjusting screw under the cap nut on the top cover. Timing Ranges: Code Range Code Range A B C D E F .03 to .1 sec. .1 to .3 sec. .15 to 1.0 sec. .375 to 3.0 sec. .75 to 10.0 sec. 1.0 to 30.0 sec. G H J K L 2.0 to 60.0 sec. 5.0 to 120.0 sec. 5.0 to 180.0 sec. 1.5 to 30.0 cycles 3.0 to 120.0 cycles Dimensions are shown for 1254 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. --4 --5 --9 These are minimum standards; where more severe environmental conditions must be met, please consult the factory. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT Outline Dimensions for Industrial Models (Dimensions in inches. Multiply by 25.4 to obtain millimeters.) Ordering Information for Industrial Models Typical Part No. ➤ 21 1 2 D 4 N B 1. Basic Series: 21 = 2100 Miniature electropneumatic timing relay 2. Operation: 1 = On-delay 2 = Off-delay 3. Contact Arrangement: 2 = DPDT (2 form C) 4. Operating Voltage: A = AC D = DC 5. Physical Characteristics: Code Enclosure Adjustment Connector Mounting 4= Unsealed External Knob Octal Plug Chassis Mount 5= Unsealed Internal Key Octal Plug Chassis Mount 9= Unsealed Internal Key Solder Hook Panel Mount Plate 6. Coil Voltage: M = 12VDC N = 28VDC P = 48VDC R = 110VDC Y = 125VDC S = 120VAC, 50/60 Hz. T = 240VAC, 60 Hz. 7. Timing Range: A = .03 to .1 sec. C = .15 to 1.0 sec. E = .75 to 10.0 sec. H = 5.0 to 120.0 sec. K = 1.5 to 30.0 cycles B = .1 to .3 sec. D = .375 to 3.0 sec. F = 1.0 to 30.0 sec. J = 5.0 to 180.0 sec. L = 3.0 to 120.0 cycles Our authorized distributors are more likely to maintain the following items in stock for immediate delivery.. None at present. Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1255 Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT Specifications for MIL-Spec and Hermetically Sealed Models Dielectric: In accordance with specification MIL-R6106E (ASG). Also withstands 1,000 Volts RMS at 60 Hz between non-connected terminals. Agastat timing relays perform to military specifications in Patriot missiles. Other: Agastat Miniature Timing Relays also conform to applicable Mil-Spec. requirements covering: Moisture Ozone Humidity Sunshine Sand/Dust Acoustic Noise Salt Spray Prolonged Storage Outline Dimensions for MIL-Spec and Hermetically Sealed Models (In inches. Multiply by 25.4 for millimeters). 8 pin solder hook or MS/AN Connector 8 pin solder hook or MS/AN Connector Panel Mount —9 Panel Mount —H1, —H3 Octal Plug (with internal adjustment or external adjustment knob Octal Plug (with internal adjustment or external adjustment knob Chassis Mount —H2 Chassis Mount —4, —5 Ordering Information for MIL-Spec and Hermetically Sealed Models Typical Part No. ➤ 21 1 2 D H1 N B 1. Basic Series: 21 = 2100 Miniature electropneumatic timing relay 2. Operation: 1 = On-delay 2 = Off-delay 3. Contact Arrangement: 2 = DPDT (2 form C) 4. Operating Voltage: A = AC D = DC 5. Physical Characteristics: Code Enclosure Adjustment Connector Mounting H1 = Hermetically Sealed External Screw Solder Hook Panel Mount Plate H2 = Hermetically Sealed External Screw Octal Plug Chassis Mount H3 = Hermetically Sealed External Screw “AN” Connector Panel Mount Plate 4= Unsealed External Knob Octal Plug Chassis Mount 5= Unsealed Internal Key Octal Plug Chassis Mount 9= Unsealed Internal Key Solder Hook Panel Mount Plate 6. Coil Voltage: M = 12VDC N = 28VDC P = 48VDC R = 110VDC Y = 125VDC S = 120VAC, 50/60 Hz. T = 240VAC, 60 Hz. U = 115VAC, 400 Hz. 7. Timing Range: A = .03 to .1 sec. C = .15 to 1.0 sec. E = .75 to 10.0 sec. H = 5.0 to 120.0 sec. K = 1.5 to 30.0 cycles B = .1 to .3 sec. D = .375 to 3.0 sec. F = 1.0 to 30.0 sec. J = 5.0 to 180.0 sec. L = 3.0 to 120.0 cycles Our authorized distributors are more likely to maintain the following items in stock for immediate delivery.. None at present. Dimensions are shown for 1256 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover.