XPPOWER JCL2548S1V8

DC-DC
25 Watts
xppower.com
JCL Series
•
2:1 Input Range
•
High Efficiency up to 90%
•
-40 °C to +100 °C Operating Temperature
•
Fixed 300 kHz Switching Frequency
•
Regulated Single Outputs
•
Continuous Short Circuit Protection
•
Six-sided Metal Case or Open Frame
Specification
Input
Input Voltage Range
Input Current
Input Filter
Undervoltage Lockout
General
• 24 VDC (18-36 VDC)
48 VDC (36-75 VDC)
• See table
• Pi network
• Turn on >71% nominal input,
Turn off <67% nominal input
Output
Output Voltage
Output Voltage Adj
Minimum Load
Line Regulation
Load Regulation
Setpoint Accuracy
Ripple & Noise
Transient Response
Efficiency
Isolation Voltage
Switching Frequency
MTBF
• See table
• 1500 VDC Input to Output
1500 VDC Input to Case
-V Output is connected to case
• 300 kHz typical
• >750 kHrs to MIL-STD-217F
Environmental
•
•
•
•
•
•
•
See table
±10%
No minimum load required
±0.5% max
±0.5% max from 10% to full load
±1.0% max
1.8 V, 2.5 V, 3.3 V & 5.0 V models
75 mV pk-pk max (20 MHz bandwidth)
12.0 V & 15.0 V models
100 mV pk-pk max (20 MHz bandwidth)
• 5% max deviation, recovery to within
1% in 300 µs for a 25% load change
• 0.02%/°C
Temperature
Coefficient
Overvoltage Protection • 1.8 V & 2.5 V models 3.3 V typical,
3.3 V models 3.9 V typical,
5.0 V models 6.2 V typical,
12.0 V models 15.0 V typical,
15.0 V models 18.0 V typical
Overcurrent Protection • 110-150%
Short Circuit Protection • Trip & restart (hiccup mode)
Remote On/Off
• ON >3.5 VDC or open circuit
OFF <1.8 VDC
Optional negative logic, add suffix ‘-N’
to model number
Thermal Protection
• Shuts down when case measures
+110 °C typical
Operating Temperature
Case Temperature
Storage Temperature
Cooling
Operating Humidity
Shock
Vibration
•
•
•
•
•
•
-40 °C to +100 °C (see derating curve)
+100 °C max
-55 °C to +125 °C
Convection-cooled
Up to 90%, non-condensing
30 g, half sine wave 18 ms pulse applied
3 times on each of 6 axes
• 5-500 Hz, 3 g, for 10 mins on each
of 3 axes
EMC
Emissions
ESD Immunity
Radiated Immunity
Conducted Immunity
• EN55022, Level A conducted & radiated
with external components - contact
technical sales
• EN61000-4-2, Level 2 Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-6, 3 V rms Perf Criteria A
Input
Voltage
Output
Voltage
1.8 VDC
2.5 VDC
3.3 VDC
5.0 VDC
12.0 VDC
15.0 VDC
1.8 VDC
2.5 VDC
3.3 VDC
5.0 VDC
12.0 VDC
15.0 VDC
18-36 VDC
36-75 VDC
Input Current(1)
No Load
Full Load
60 mA
714 mA
55 mA
749 mA
55 mA
729 mA
60 mA
1157 mA
30 mA
1149 mA
30 mA
1149 mA
30 mA
397 mA
30 mA
473 mA
40 mA
463 mA
40 mA
579 mA
20 mA
568 mA
20 mA
568 mA
Output
Current
8.0 A
8.0 A
6.0 A
5.0 A
2.0 A
1.6 A
8.0 A
8.0 A
6.0 A
5.0 A
2.0 A
1.6 A
Model
Number(2, 3)
JCL2524S1V8
JCL2524S2V5
JCL2524S3V3
JCL2524S05
JCL2524S12
JCL2524S15
JCL2548S1V8
JCL2548S2V5
JCL2548S3V3
JCL2548S05
JCL2548S12
JCL2548S15
Efficiency
84%
88%
89%
90%
89%
89%
84%
88%
89%
80%
88%
88%
Notes
1. Input currents specified at nominal 24 V or 48 V input.
2. For optional open frame version, add suffix ‘-U’ to model number.
3. For optional negative logic Remote On/Off, add suffix ‘-N’ to model number.
Mechanical Details
All dimensions are in inches (mm)
Weight: 25 g (0.06 lbs)
Open Frame
1.60
(40.64)
0.70
0.50
(17.78)
(12.70)
0.30
0.10
(7.62)
(2.54)
6
7
8
0.600
(15.24)
0.22min
(5.60)
0.200
(5.08)
4
3
1
0.040
(1.02)
0.70
(17.78)
0.070
(1.78)
Metal Case
5
0.04 DIA
(1.02)
BOTTOM
2.00
(50.80)
VIEW
4
0.70
(17.78)
3
1
0.20
(5.08)
0.45
(11.43)
0.60
(15.24)
PIN CONNECTIONS
Pin
Function
1
On/Off Control
3
- V Input
4
+V Input
5
Trim
6 -V Output & Case
7
+V Output
8
No Pin
1.95
(49.50)
1.80
(45.72)
1.80
(45.72)
TOP VIEW
7
0.100
(2.54)
6
0.300
(7.62)
0.14
(3.60)
0.15
(3.80)
5
0.70
(17.78)
1.55
(39.40)
0.40
(10.16)
PIN CONNECTIONS
Pin
Function
1
On/Off Control
3
- V Input
4
+V Input
5
Trim
6
-V Output
7
+V Output
8
No Pin
Application Notes
Derating Curve
External Output Trim
Derating:
Metal case models above +70 °C, linearly to zero power at 100 °C.
Open frame models above +60 °C, linearly to zero power at 100 °C.
+Vout (3)
+Vout (3)
TRIM DOWN
-3.33%/°C for metal case models
100
TRIM (4)
TRIM (4)
-2.50%/°C for open frame models
10K ohms
TRIMPOT
Load (%)
80
TRIM U P
60
-Vout (5)
-Vout (5)
40
20
0
-40 -20
0
10
20 30 40 50 60
Ambient Temperature (ºC)
70
80
90
100
Remote On/Off Control
Standard ROF logic is positive.
Output On >3.5 VDC or open circuit
Output Off <1.8 VDC
Optional ROF logic is negative (‘-N’ version).
Output On <1.8 VDC
Output Off >3.5 VDC or open circuit
17-Apr-07
DC-DC
JCL
Models and Ratings