XPPOWER JPS130PS12-M

AC-DC
130 Watts
xppower.com
JPS130/JPS130-M Series
•
High Efficiency - up to 90%
•
Medical Approval (JPS130-M Versions)
•
3” x 5” Footprint
•
Zero Voltage Switching Technology
•
High Power Density
•
100 W Convection-cooled
•
Single & Multi Outputs
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
General
•
•
•
•
•
•
90-264 VAC (130-370 VDC)
47-63 Hz
2.0/1.0 A max at 115/230 VAC
30 A at 115 VAC, 60 A at 230 VAC
0.9 typical
1.5 mA max at 264 VAC/60 Hz JPS130
250 µA max at 240 VAC/60 Hz JPS130-M
• Internal 3.15 A/250 V fuse
Both line & neutral fused (JPS130-M)
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
• Up to 90% nominal line, full load
• 3000 VAC Input to Output (JPS130),
4000 VAC Input to Output (JPS130-M),
1500 VAC Input to Ground,
500 VAC Output to Ground
• 120 kHz fixed, ±10% for both active
PFC & PWM
• 6.7 W/In3
• 250 kHrs per MIL-HDBK-217F at 25 °C
Environmental
Output
Output Voltage
Output Voltage Trim
• See table
• ±10% on single output models,
±5% on multi output models, other
voltages will track by the same percentage
Initial Set Accuracy
• At 60% rated load ±1% single outputs,
±3% on V1 for multi outputs
Minimum Load
• Single output: no minimum load required
Multi-outputs: (see note 1)
Start Up Rise Time
• <20 ms
Hold Up Time
• 16 ms typical at low line
Line Regulation
• ±0.5% Vmin to Vmax
Load Regulation
• ±1%, ±5% for auxiliaries, 20-100%
of rated load
Transient Response
• 4% max deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
• ±1% max pk-pk (see note 4)
Overvoltage Protection • 110-140% on V1 only,
recycle input to reset
Overload Protection
• 110-150%, auto recovery
Short Circuit Protection • Trip & restart (Hiccup mode)
Temperature
• 0.05%/°C
Coefficient
Remote Sense
• Single output models only, compensates
for up to 0.5 V drop
Fan Output
• 12 V, 450 mA multi-output models only
Operating Temperature • 0 °C to +70 °C, (see derating curves)
Cooling
• 130 W with 18 CFM airflow,
100 W with convection cooling
Operating Humidity
• 5-95% RH, non-condensing
Storage Temperature
• -20 °C to +85 °C
Operating Altitude
• 3000 m
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55022, level B conducted
FCC 20780, level B conducted
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, 10 V/m Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 3 V Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
95% 5000 ms Perf Criteria A, B, B
• JPS130:
EN60950-1:2001, UL60950-1,
CSA C22.2 No. 60950-1,
CE Mark LVD.
JPS130-M: UL2601-1, EN60601-1,
CSA C22.2 No. 601.1
CE Mark LVD.
Output Current
Convection-cooled
18 CFM
Output
Power(3)
Output
Voltage
100 W
3.3 V
25.0 A
30.0 A
50 mV
JPS130PS03^
5.0 V
20.0 A
26.0 A
50 mV
JPS130PS05†^
12.0 V
9.0 A
10.8 A
120 mV
JPS130PS12†^
15.0 V
7.0 A
8.7 A
120 mV
JPS130PS15†^
24.0 V
4.5 A
5.4 A
200 mV
JPS130PS24†^
48.0 V
2.3 A
2.7 A
200 mV
JPS130PS48†^
130 W
130 W
Ripple & Noise
Pk-Pk(4)
5.0 V
(1)
11.5 A
15.0 A
50 mV
12.0 V
(2)
3.0 A
5.0 A
100 mV
-12.0 V
(2)
0.5 A
0.5 A
100 mV
3.3 V
(1)
10.0 A
15.0 A
50 mV
5.0 V
(2)
8.0 A
15.0 A
50 mV
12.0 V
(2)
0.5 A
0.5 A
100 mV
130 W
Model
Number
JPS130PT31(2)†^
JPS130PT30(2)†^
Notes
1. 20% minimum load required on V1 to maintain stated regulation for auxiliary rails.
2. Load regulation of auxiliary rails is defined over the range of 60% of rated output ±40%.
3. Maximum power with 18 CFM of forced air.
4. Ripple and noise measured over 15 MHz bandwidth with a 47 µF electrolytic capacitor and 0.47 µF ceramic capacitor.
5. Covers available, order part number ‘JPS130 COVER’†^ or add suffix ‘-C’ to receive the unit with cover fitted. Overall dimensions 90.6 x 142.9 x 39.8 mm.
6. Connector kits and cable harnesses available. Consult sales for options.
† Available from Farnell. See pages 204-206.
^ Available from Newark. See pages 207-208.
Mechanical Details
All dimensions are in inches (mm).
Tolerance: 0.02 (0.4) max.
Weight: 0.5 lbs (240 g) approx.
0.225 (5.7)
0.16 (4.0) Dia Mounting Hole (4 Places)
1
N TB1
TB3
2.55 (64.8)
3.00 (76.2)
TB2
L
See page 29 for
TB2 pin connections
1
4.55 (115.6)
5.00 (127.0)
To Chassis Grounding x 2
1.18 (30.0)(1)
Pin
1
2
TB3 PIN CONNECTIONS
Single Output
Multi Output
- Sense
0V
+ Sense
+12 V Fan
0.10 (2.5)
Notes
1. Single output model shown, add extra 0.08” (2.0mm) to overall height for multi-output models.
2. AC input connector (TB1): Molex 5277-02A or equivalent. Mates with 5196-N housings.
3. DC output connector (TB2): Molex 5273 or equivalent, mates with 5195-N and 5239-N housings except JPS130PS03 which has a 6-position terminal screw
block: Dinkle part number EHK508V Series accepts 24-12 AWG wire.
4. TB3: Molex 5045-02A or equivalent. Single output units - TB3 is remote sense. Multi-output units - TB3 is 12 V, 450 mA fan output.
AC-DC
JPS130
Models and Ratings
Output
Power(3)
Output Current
Convection-cooled
18 CFM
Output
Voltage
130 W
130 W
130 W
130 W
Ripple & Noise
Pk-Pk(4)
Model
Number
5.0 V
20.0 A
26.0 A
50 mV
JPS130PS05-M†^
12.0 V
9.0 A
10.8 A
120 mV
JPS130PS12-M†^
15.0 V
7.0 A
8.7 A
120 mV
JPS130PS15-M†^
24.0 V
4.5 A
5.4 A
200 mV
JPS130PS24-M†^
28.0 V
3.8 A
4.6 A
200 mV
JPS130PS28-M†^
48.0 V
2.3 A
2.7 A
200 mV
JPS130PS48-M†^
5.0 V
(1)
10.0 A
15.0 A
50 mV
12.0 V
(2)
3.0 A
4.1 A
120 mV
-12.0 V
(2)
0.8 A
1.1 A
120 mV
5.0 V
(1)
10.0 A
15.0 A
50 mV
15.0 V
(2)
2.5 A
4.1 A
150 mV
-15.0 V
(2)
0.8 A
1.1 A
150 mV
5.0 V
(1)
2.5 A
4.0 A
50 mV
24.0 V
(2)
2.8 A
4.0 A
240 mV
12.0 V
(2)
0.7 A
1.0 A
120 mV
JPS130PT31-M(2)†^
JPS130PT32-M(2)†^
JPS130PT34-M(2)†
Notes
1. 20% minimum load required on V1 to maintain stated regulation for auxiliary rails.
2. Load regulation of auxiliary rails is defined over the range of 60% of rated output ±40%.
3. Maximum power with 18 CFM of forced air.
4. Ripple and noise measured over 15 MHz bandwidth with a 47 µF electrolytic capacitor and 0.47 µF ceramic capacitor.
5. Covers available, order part number ‘JPS130-M COVER’†^ or add suffix ‘-C’ to receive the unit with cover fitted. Overall dimensions 89.5 x 143.0 x 40.0 mm.
6. Connector kits and cable harnesses available. Consult sales for options.
† Available from Farnell. See pages 204-206.
^ Available from Newark. See pages 207-208.
Mechanical Details
All dimensions are in inches (mm).
Tolerance: ± 0.02 (0.4) max.
Weight: 0.5 lbs (240 g) approx.
0.20 (5.0)
0.16 (4.0) Dia Mounting Hole (4 Places)
2.60 (66.2)
3.00 (76.2)
TB2
L
N TB1
See page 29 for
TB2 pin connections
1
TB3
1
4.60 (117.0)
5.00 (127.0)
To Chassis Grounding x 2
Pin
1
2
1.18 (30.0)(1)
AC-DC
JPS130-M
Models and Ratings
TB3 PIN CONNECTIONS
Single Output
Multi Output
- Sense
0V
+ Sense
+12 V Fan
0.10 (2.5)
Notes
1. Single output model shown, add extra 0.08” (2.0 mm) to overall height for multi-output models.
2. AC input connector (TB1): Molex 5277-02A or equivalent. Mates with 5196-N housings.
3. DC output connector (TB2): Molex 5273 or equivalent. Mates with 5195-N and 5239-N housings.
4. TB3: Molex 5045-02A or equivalent. Single output units - TB3 is remote sense. Multi-output units - TB3 is 12 V, 450 mA fan output.
JPS130 PIN CONNECTIONS
TB2
1
2
3
4
5
6
7
8
9
10
Type
PS05
+V
+V
+V
+V
Return
Return
Return
Return
PS03, 12, 15, 24, 48
+V
+V
+V
Return
Return
Return
PT31
+5 V
+5 V
+5 V
Return
Return
Return
Return
+12 V
-12 V
Molex 5273-08A
Molex 5273-06A
Molex 5273-09A
PT30
+3.3 V
+3.3 V
Return
Return
Return
Return
Return
+5 V
+5 V
+12 V
Molex 5273-10A
JPS130-M PIN CONNECTIONS
TB2
1
2
3
4
5
6
7
8
9
Type
PS05
Return
Return
Return
Return
+V
+V
+V
+V
PS12, 15, 24, 28, 48
Return
Return
Return
+V
+V
+V
Molex 5273-08A
Molex 5273-06A
PT31
-12 V
+12 V
Return
Return
Return
Return
+5 V
+5 V
+5 V
PT32
-15 V
+15 V
Return
Return
Return
Return
+5 V
+5 V
+5 V
Molex 5273-09A
PT34
+12 V
+24 V
Return
Return
Return
Return
+5 V
+5 V
+5 V
Derating Curves
JPS130
130
A
A
JPS130 with 18 CFM fan (except JPS130PS03).
B
JPS130PS12, PS15, PS24 and PS48 with convection cooling.
JPS130PS03 with 18 CFM fan.
C
JPS130PS05, PT30, PT31, PT32 and PT34 with convection cooling.
D
JPS130PS03 with convection cooling.
A
JPS130-M with 18 CFM fan.
B
JPS130PS12-M, PS15-M, PS24-M and PS48-M with convection cooling.
C
JPS130PS05-M, PT30-M, PT31-M, PT32-M and PT34-M
with convection cooling.
Load (W)
100
C
B
D
80
60
40
20
0
-10
0
10
20
30
40
50
60
70
Ambient Temp (˚C)
JPS130-M
130
A
Load (W)
100
C
B
80
60
40
20
0
-10
0
10
20
30
40
50
60
70
Ambient Temp (˚C)
25-Sept-08
AC-DC
JPS130/JPS130-M
Pin Connections