OMRON K34-C1

Weighing Indicator
K3HB-V
CSM_K3HB-V_DS_E_8_1
An Ideal Indicator for OK/NG Judgements in Automated and
Picking Machines, Measuring Factors such as Pressure,
Load, Torque, and Weight Using Load Cell Signal Input.
• Easy recognition of judgement results using color display that can be switched
between red and green. *
• Equipped with a position meter for monitoring operating status trends.
• External event input allows use in various measurement and discrimination applications.
• Input 0.001 mVDC or higher (0.000 to 19.999 mV range supported).
External power takeoff of 100 mA at 10 VDC provided. (Models with
5-VDC power takeoff also available.)
• Series expanded to include DeviceNet models.
• Short body with depth of only 95 mm (from behind the front panel), or 97 mm
for DeviceNet models.
• UL certification approval (Certification Mark License).
• CE Marking conformance by third party assessment body.
• Water-resistant enclosure conforms to NEMA 4X (equivalent to IP66).
• Capable of high-speed sampling at 50 times per second (20 ms)
• Easy-to-set two-point scaling allows conversion and display of any user-set values.
* Visual confirmation of judgement results is not supported on models that do not have an
output or models that do not support DeviceNet.
You can change the display color by setting it, but you cannot switch it based on the judgement results.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Refer to Safety Precautions for All Digital Panel
Meters.
Model Number Structure
■ Model Number Legend
Base Units and Optional Boards can be ordered individually or as sets.
Base Units
Base Units with Optional Boards
K3HB-V@
K3HB-V@-@@@
1
5
1. Input Sensor Code
LC: Load cell input (DC low-voltage input)
5. Supply Voltage
100-240 VAC: 100 to 240 VAC
24 VAC/VDC: 24 VAC/VDC
1 2 3 4
5
2. Sensor Power Supply/Output Type Code
None:
CPB:
L1B:
L2B:
B:
FLK1B:
FLK3B:
CPE:
L1E:
L2E:
E:
FLK1E:
FLK3E:
None
Relay output (PASS: SPDT) + Sensor power supply
(10 VDC +/−5%, 100 mA) (See note 1.)
Linear current output (0 to 20 or 4 to 20 mA DC) + Sensor power
supply (10 VDC +/−5%, 100 mA) (See note 2.)
Linear voltage output (0 to 5, 1 to 5, or 0 to 10 VDC) + Sensor
power supply (10 VDC +/−5%, 100 mA) (See note 2.)
Sensor power supply (10 VDC +/−5%, 100 mA)
Communications (RS-232C) + Sensor power supply
(10 VDC +/−5%, 100 mA) (See note 2.)
Communications (RS-485) + Sensor power supply
(10 VDC +/−5%, 100 mA) (See note 2.)
Relay output (PASS: SPDT) + Sensor power supply
(5 VDC +/−5%, 100 mA) (See note1.)
Linear current output (DC0(4) −20 mA) + Sensor power supply
(5 VDC +/−5%, 100 mA) (See note 2.)
Linear voltage output (DC0(1) −5 V, 0−10 V)+ Sensor power
supply (5 VDC +/−5%, 100 mA) (See note 2.)
Sensor power supply (5 VDC +/−5%, 100 mA)
Communications (RS-232C) + Sensor power supply
(5 VDC +/−5%, 100 mA) (See note 2.)
Communications RS-485) + Sensor power supply
(5 VDC +/−5%, 100 mA) (See note 2.)
Optional Boards
Sensor Power Supply/Output Boards
K33-@
2
Relay/Transistor Output Boards
K34-@
3
Event Input Boards
K35-@
4
3. Relay/Transistor Output Type Code
None: None
C1: Relay contact (H/L: SPDT each)
C2: Relay contact (HH/H/LL/L: SPST-NO each)
T1: Transistor (NPN open collector: HH/H/PASS/L/LL)
T2: Transistor (PNP open collector: HH/H/PASS/L/LL)
BCD *: BCD output + transistor output (NPN open collector: HH/H/PASS/L/LL)
DRT: DeviceNet (See note 2.)
* A Special BCD Output Cable (sold separately) is required.
4. Event Input Type Code
None: None
1: 5 inputs (M3 terminal blocks), NPN open collector
2: 8 inputs (10-pin MIL connector), NPN open collector
3: 5 inputs (M3 terminal blocks), PNP open collector
4: 8 inputs (10-pin MIL connector), PNP open collector
Note: 1. CPB, CPE can be combined with relay outputs only.
2. Only one of the following can be used by each Digital Indicator: RS-232C/RS-485 communications, a linear output, or DeviceNet communications.
Accessories (Sold Separately)
K32-DICN: Special Cable (for event inputs, with 8-pin connector)
K32-BCD: Special BCD Output Cable
Rubber Packing
Model
K32-P1
Note: Rubber packing is provided with the Controller.
1
K3HB-V
Specifications
■ Ratings
Power supply voltage
100 to 240 VAC (50/60 Hz), 24 VAC/VDC, DeviceNet power supply: 24 VDC
Allowable power supply voltage range
85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC
Power consumption
(See note 1.)
100 to 240 V: 18 VA max. (max. load)
24 VAC/DC: 11 VA/7 W max. (max. load)
Current consumption
DeviceNet power supply: 50 mA max. (24 VDC)
Input
DC voltage
A/D conversion method
Delta-Sigma method
External power supply
10 VDC ±5%, 100 mA (models with external power supply only) or 5 VDC, 100 mA (models with external
power supply only)
Event inputs
(See note 2.)
Timing input
NPN open collector or no-voltage contact signal
ON residual voltage: 3 V max.
ON current at 0 Ω: 17 mA max.
Max. applied voltage: 30 VDC max.
OFF leakage current: 1.5 mA max.
Startup compensation
timer input
NPN open collector or no-voltage contact signal
ON residual voltage: 2 V max.
ON current at 0 Ω: 4 mA max.
Max. applied voltage: 30 VDC max.
OFF leakage current: 0.1 mA max.
Hold input
Reset input
Forced-zero input
Bank input
Output ratings (depends Relay output
on the model)
250 VAC, 30 VDC, 5 A (resistive load)
Mechanical life expectancy: 5,000,000 operations, Electrical life expectancy: 100,000 operations
Transistor output
Maximum load voltage: 24 VDC, Maximum load current: 50 mA, Leakage current: 100 µA max.
Linear output
Linear output 0 to 20 mA DC, 4 to 20 mA DC:
Load: 500 Ω max, Resolution: Approx. 10,000, Output error: ±0.5% FS
Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC:
Load: 5 kΩ max, Resolution: Approx. 10,000, Output error: ±0.5% FS
(1 V or less: ±0.15 V; no output for 0 V or less)
Display method
Negative LCD (backlit LED) display
7-segment digital display (Character height: PV: 14.2 mm (green/red); SV: 4.9 mm (green)
Main functions
Scaling function, measurement operation selection, averaging, previous average value comparison, forcedzero, zero-limit, output hysteresis, output OFF delay, output test, teaching, display value selection, display
color selection, key protection, bank selection, display refresh period, maximum/minimum hold, reset
Ambient operating temperature
−10 to 55°C (with no icing or condensation)
Ambient operating humidity
25% to 85%
Storage temperature
−25 to 65°C (with no icing or condensation)
Altitude
2,000 m max.
Accessories
Watertight packing, 2 fixtures, terminal cover, unit stickers, operation manual. DeviceNet models also include
a DeviceNet connector (Hirose HR31-5.08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note
3.)
Note: 1. DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular attention is required
when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommended.
2. PNP input types are also available.
3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for Thin Cables.
2
K3HB-V
■ Characteristics
Display range
−19,999 to 99,999
Sampling period
20 ms (50 times/second)
Comparative output response time 100 ms max.
Linear output response time
150 ms max.
Insulation resistance
20 MΩ min. (at 500 VDC)
Dielectric strength
2,300 VAC for 1 min between external terminals and case
Noise immunity
100 to 240 VAC models:
±1,500 V at power supply terminals in normal or common mode
(waveform with 1-ns rising edge and pulse width of 1 μs/100 ns)
24 VAC/VDC models:
±1,500 V at power supply terminals in normal or common mode
(waveform with 1-ns rising edge and pulse width of 1 μs/100 ns)
Vibration resistance
Frequency: 10 to 55 Hz; Acceleration: 50 m/s2, 10 sweeps of 5 min each in X, Y, and Z directions
Shock resistance
150 m/s2 (100 m/s2 for relay outputs) 3 times each in 3 axes, 6 directions
Weight
Degree of
protection
Approx. 300 g (Base Unit only)
Front panel
Conforms to NEMA 4X for indoor use (equivalent to IP66)
Rear case
IP20
Terminals
IP00 + finger protection (VDE0106/100)
Memory protection
EEPROM (non-volatile memory)
Number of rewrites: 100,000
Applicable standards
UL61010-1, CSA C22.2 No. 61010-1-04
EN61010-1 (IEC61010-1): Pollution degree 2/Overvoltage category II
EN61326-1
EMC
EMI: EN61326 industrial applications
Electromagnetic radiation interference
CISPR 11 Group 1, Class A
Terminal interference voltage
CISPR 11 Group 1, Class A
EMS: EN61326 industrial applications
Electrostatic Discharge Immunity
EN61000-4-2: 4 kV (contact), 8 kV (in air)
Radiated Electromagnetic Field Immunity
EN61000-4-3: 10 V/m 1 kHz sine wave amplitude modulation (80 MHz to 1 GHz, 1.4 to 2 GHz)
Electrical Fast Transient/Burst Immunity
EN61000-4-4: 2 kV (power line), 1 kV (I/O signal line)
Surge Immunity
EN61000-4-5: 1 kV with line (power line), 2 kV with ground (power line)
Conducted Disturbance Immunity
EN61000-4-6: 3 V (0.15 to 80 MHz)
Power Frequency Magnetic Immunity
EN61000-4-8: 30 A/m (50 Hz) continuous time
Voltage Dips and Interruptions Immunity
EN61000-4-11: 0.5 cycle, 0°/180°, 100% (rated voltage)
3
K3HB-V
■ Input Ranges (Measurement Range and Accuracy)
Input type
Range
K3HB-VLC
Load Cell, mV
Set value
Measurement range
Input impedance
Accuracy
±0.1% rdg ±1 digit max.
A
a lc
0.00 to 199.99 mV
B
b lc
0.000 to 19.999 mV
±0.1% rdg ±5 digits max.
1 MΩ min.
C
c lc
±100.00 mV
±0.1% rdg ±3 digits max.
D
d lc
±199.99 mV
±0.1% rdg ±1 digit max.
Allowable
instantaneous
overload (30 s)
±200 V
Note: 1. The accuracy is for an ambient temperature of 23±5°C. For all ranges,10% or less of max. input ±0.1% FS.
2. The letters “rdg” mean “reading.”
Input type
Connected
terminals
(mV)
200.000
150.000
100.000
50.000
0.00
−50.00
−100.00
−150.00
−200.00
Maximum
measurement range
a lc
E2
b lc
E6
E3
c lc
E6
E4
E6
199.99
d lc
E5
E6
199.99
100.00
19.999
0.00
0.000
−100.00
−199.99
-19.99 to 219.99 mV -1.999 to 21.999 mV -110.00 to 110.00 mV -199.99 to 219.99 mV
The area shown in dark shading indicates the factory setting.
■ Load Cell Wiring Example
B
E
+10 V (10-VDC, 100-mA
external power supply)
or
+5 V (5-VDC, 100-mA
external power supply)
E2
■ Scaling Example Using Range A
Indicated on the K3HB-V as 0 to 49N in the load cell specifications
(rated load 49N, recommended applied voltage 10 V, rated output
2 mV/V) (See note.)
Display value
+IN
Scaling values:
49 N
E3
E4
B5
E5
B6
E6
+OUT
Load cell
inp.a1=000.00
dsp.a1=00000
inp.a2=020.00
dsp.a2=49000
dp decimal point position: 00.000
−OUT
+
−IN
20 mV
−
0V
Input value
Note: “2 mV/V” indicates a load cell output of 2 mV for 1 V applied
voltage for the rated load (when using a load of 1 N). When the
applied voltage is 10 V, the load cell output is 20 mV (2 mV ×
10).
The precision can be increased by entering the A1 and A2 input
values by teaching, and then scaling the results.
4
K3HB-V
Common Specifications
■ Event Input Ratings
Input type
S-TMR, HOLD, RESET, ZERO, BANK1, BANK2,
BANK4
TIMING
Contact
ON: 1 kΩ max., OFF: 100 kΩ min.
---
No-contact
ON residual voltage: 2 V max.
OFF leakage current: 0.1 mA max.
Load current: 4 mA max.
Maximum applied voltage: 30 VDC max.
ON residual voltage: 3 V max.
OFF leakage current: 1.5 mA max.
Load current: 17 mA max.
Maximum applied voltage: 30 VDC max.
■ Output Ratings
Contact Output
Item
Transistor Output
Inductive loads
(250 VAC, closed
circuit, cosφ=0.4;
30 VDC, L/R=7 ms)
Resistive loads
(250 VAC, cosφ=1;
30 VDC, L/R=0 ms)
Rated load
5 A at 250 VAC
5 A at 30 VDC
Rated through
current
5A
Maximum load voltage
24 VDC
Maximum load current
50 mA
Leakage current
100 µA max.
1 A at 250 VAC
1 A at 30 VDC
Mechanical life 5,000,000 operations
expectancy
Electrical life
expectancy
100,000 operations
Linear Output
Item
0 to 20 mA
Allowable load impedance
500 Ω max.
Resolution
Approx. 10,000
Output error
±0.5%FS
4 to 20 mA
Serial Communications Output
Item
RS-232C, RS-485
Start-stop synchronization
Baud rate
9,600, 19,200, or 38,400 bps
Transmission code
ASCII
Data length
7 bits or 8 bits
Stop bit length
2 bits or 1 bit
Error detection
Vertical parity and FCS
Parity check
Odd, even
Note: For details on serial and DeviceNet communications, refer to
the Digital Indicator K3HB Communications User's Manual
(Cat.No. N129).
1 to 5 V
0 to 10 V
±0.5%FS (1 V or less: no output for ±0.15 V; 0 V or less)
BCD Output I/O Ratings
(Input Signal Logic: Negative)
Communications method Half duplex
Synchronization method
0 to 5 V
5 kΩ min.
I/O signal name
Inputs
REQUEST
HOLD
MAX
MIN
RESET
Outputs DATA
POLARITY
OVER
DATA VALID
RUN
HH
H
PASS
L
LL
Item
Rating
Input signal
No-voltage
contact input
Input current for
no-voltage input
10 mA
Signal ON voltage 1.5 V max.
level
OFF voltage 3 V min.
Maximum load
voltage
Maximum load
current
Leakage current
Maximum load
voltage
Maximum load
current
Leakage current
24 VDC
10 mA
100 µA max.
24 VDC
50 mA
100 µA max.
Note: For details on serial and DeviceNet communications, refer to
the Digital Indicator K3HB Communications User's Manual
(Cat.No. N129).
5
K3HB-V
DeviceNet Communications
Communications protocol
Conforms to DeviceNet
Supported communi- Remote I/O communications
cations
Master-Slave connection (polling, bit-strobe, COS, cyclic)
Conforms to DeviceNet communications standards.
I/O allocations
Allocate any I/O data using the Configurator.
Allocate any data, such as DeviceNet-specific parameters and variable area for Digital
Indicators.
Input area: 2 blocks, 60 words max.
Output area: 1 block, 29 words max.
(The first word in the area is always allocated for the Output Execution Enabled Flags.)
Message communications
Explicit message communications
CompoWay/F communications commands can be executed (using explicit message
communications)
Connection methods
Combination of multi-drop and T-branch connections (for trunk and drop lines)
Baud rate
DeviceNet: 500, 250, or 125 Kbps (automatic follow-up)
Communications media
Special 5-wire cable (2 signal lines, 2 power supply lines, 1 shield line)
Communications distance
Baud rate
Network length
(max.)
Drop line length
(max.)
Total drop line
length (max.)
500 Kbps
100 m (100 m)
6m
39 m
250 Kbps
100 m
(250 m)
6m
78 m
125 Kbps
100 m
(500 m)
6m
156 m
The values in parentheses are for Thick Cable.
Communications power supply
24-VDC DeviceNet power supply
Allowable voltage fluctuation range
11 to 25-VDC DeviceNet power supply
Current consumption
50 mA max. (24 VDC)
Maximum number of nodes
64 (DeviceNet Configurator is counted as one node when connected)
Maximum number of slaves
63
Error control checks
CRC errors
DeviceNet power supply
Supplied from DeviceNet communications connector
■ Internal Block Diagram
Analog input
Input
circuit
ADC
Keys
EEP-ROM
Indications
• Input circuit
• Output circuit
• Transistor
output circuit
Drive
circuit
Drive
circuit
Event input
Digital input
circuit
Waveform
shaping circuit
Linear output
Linear output
circuit
Drive
circuit
Sensor power
supply
Filter
BCD
BCD I/O
Microcomputer
Drive
circuit
Transistor
output
Relay output
X
Drive
circuit
DeviceNet
circuit
DeviceNet
Drive
circuit
Communications
driver
Communications
VDD
VO
Power supply circuit (isolated)
VCOM
VO
DC-DC
Converter (isolated)
Power supply
6
K3HB-V
■ Power Supply Derating Curve for Sensor (Reference Value)
With 12 V
With 10 V
Max. current (mA)
140
Max. current (mA)
140
1
1
120
120
100
100
80
80
60
60
40
40
20
20
0
−20
−10
0
10
20
30
40
50
0
−20
60
−10
0
10
Ambient temperature (°C)
20
30
40
50
60
Ambient temperature (°C)
Note: 1. The above values are for standard mounting. The derating curve differs depending on the mounting conditions.
2. Do not use the Sensor outside of the derating area (i.e., do not use it in the area labeled A in the above graphics). Doing so may occasionally cause deterioration or damage to internal components.
■ Component Names and Functions
PV display
Max/Min status indicator
Displays PVs, maximum values,
minimum values, parameter
names, and error names.
Turns ON when the maximum value or minimum value is
displayed in the RUN level.
Level/bank display
Position meter
In RUN level, displays the bank if the bank function is
ON. (Turns OFF if the bank function is OFF.)
In other levels, displays the current level.
Displays the position of the PV with
respect to a desired scale.
SV display
Comparative output
status indicators
HH
Display the status of comparative outputs.
H
P
L
LL
Displays SV and monitor values.
Max
Min
L
T-ZR CMW
Zero Hold
TG
HH
H
T
LL
L
Status indicators
Display
T-ZR
Zero
Hold
SV display status indicators
MAX/MIN
Function
LEVEL
MODE
SHIFT
Turns ON when the tare zero function is
executed. Turns OFF if it is not executed or
is cleared.
Turns ON when the forced-zero function is
executed. Turns OFF if it is not executed or
is cleared. (Excluding the K3HB-H.)
Turns ON/OFF when hold input turns
ON/OFF.
MAX/MIN Key
Used to switch the
display between the
PV, maximum value,
and minimum value and
to reset the maximum
and minimum values.
LEVEL Key
Used to switch level.
UP
Display
TG
T
HH, H,
L, LL
MODE Key
Used to switch the
parameters displayed.
SHIFT Key
Used to change
parameter settings.
When changing a set
value, this key is used
to move along the
digits.
Function
Turns ON when the timing signal turns
ON. Otherwise OFF.
Turns ON when parameters for which
teaching can be performed are
displayed.
In RUN level, turn ON when the
comparative set values HH, H, L, and
LL are displayed.
UP Key
When changing a set value,
this key is used to change
the actual value.
When a measurement value
is displayed, this key is
used to execute or clear the
forced-zero function or to
execute teaching.
7
K3HB-V
■ BCD Output Timing Chart
A REQUEST signal from a Programmable Controller or other external device is required to read BCD data.
Single Sampling Data Output
Continuous Data Output
20-ms pulse min. (50 ms max.)
REQ.
MAX.MIN.
REQ.
MAX.MIN.
DATA
DATA
All data "High"
All data "High"
Data 1
Data 2
All data "High"
Data
DATA
VALID
DATA
VALID
Approx.
30 ms
40 ms
40 ms
Approx.
30 ms
16 ms
The data is set in approximately 30 ms from the rising edge of the
REQUEST signal and the DATA VALID signal is output.
When reading the data from a Programmable Controller, start
reading the data when the DATA VALID signal turns ON.
The DATA VALID signal will turn OFF 40 ms later, and the data will
turn OFF 16 ms after that.
24 ms
64 ms
40 ms
24 ms
64 ms
Measurement data is output every 64 ms while the REQUEST signal
remains ON.
Note: If HOLD is executed when switching between data 1 and data
2, either data 1 or data 2 is output depending on the timing of
the hold signal. The data will not go LOW.
REQ. (1)
K3HB
(1)
Programmable
Controller
REQ. (2)
K3HB
(2)
REQ. (3)
DATA (including POL and
OVER) and DATA VALID can
be used in a wired OR.
RUN, HH, H, PASS, L, and
LL are always output, with or
without a REQUEST signal.
Do not used a wired OR
connect for these signals.
K3HB
(3)
(1)
DATA
(2)
(3)
DATA
VALID
(See note.)
(See note.)
(See note.)
Note: Leave 20 ms min. between DATA VALID turning OFF and the REQUEST signal.
Programmable Controller Connection Example
Display Unit Connection Example
Digital Indicator
Digital Indicator
SYSMAC Programmable Controller
DC Input Unit
Connector pin No. (See note.)
1.COMMON
2.1
3.2
IN
2.1
IN
3.2
10°
5.8
Internal circuit
4.4
Connector pin No. (See note.)
1.COMMON
COM
IN
IN
4.4
5.8
23.DATA VALID
24.RUN
10°
23.DATA VALID
IN
24.RUN
IN
To 101
To 102
240 Ω
240 Ω
240 Ω
25.COMMON
Short26.REQUEST circuit
240 Ω
Internal circuit
+5 V
Transistor Output Unit
OUT
30.RESET
OUT
31.POLARITY
(+/− polarity)
COM
(0 V)
+5 V
240 Ω
240 Ω
30.RESET
240 Ω
240 Ω
24 VDC
31.POLARITY
(+/− polarity)
V
O
D
C
B
A
DP
LE
V
O
D
C
B
A
DP
LE
V
O
D
C
B
A
DP
LE
V
O
26.REQUEST
Internal circuit
25.COMMON
8
8
8
SEC
M7E-01D@N2, 01H@N2
+24 V
0V
<M7E Digital Display Unit>
DC power
supply
Note: The BCD output connector pin number is the D-sub connector pin number when
the BCD Output Cable (sold separately) is connected. This number differs from
the pin number for the Digital Indicator narrow pitch connector (manufactured by
Honda Tsushin Kogyo Co., Ltd.).
Refer to the following User's Manual for application precautions and other information required when using the Digital Indicator:
K3HB-S/-X/-V/-H Digital Indicator User's Manual (Cat. No. N128)
The manual can be downloaded from the following site in PDF format: OMRON Industrial Web http://www.fa.omron.co.jp
8
K3HB-V
9
K3HB-V
■ Connections
Terminal Arrangement
Note: Insulation is used between signal input, event input, output, and power supply terminals.
A
A Operating Power Supply
B
C
D
E
1
2
3
100 to 240 VAC
24 VAC/ VDC
4
5
6
A1
A2
*Check the required power supply type.
B Sensor Power Supply/Output
Sensor power supply +
PASS output
C Relays, Transistors, BCD and DeviceNet
B1
Relay Outputs
<C1>
B2
<K33CPB>
Sensor power supply
10 VDC 100 mA
<K33CPE>
12 VDC 80 mA
5 VDC 100 mA
B3
N/C B4
+
B5
B6
−
C1
H
<K33CPA>
L
10 VDC 100 mA
12 VDC 80 mA
12 VDC 80 mA
<K33L2E>
<K33L1E>
<K33L2B>
<K33L1B>
<K33L2A>
<K33L1A>
H
C2
HH
C1
H
C2
NPN
DeviceNet Connector (Included)
<DRT>
PNP
PASS C3
L
C4
L
C4
C5
LL
C5
LL
C5
COM C6
COM C6
B1
− B2
+
B3
− B4
+
B5
− B6
BCD (NPN Open Collector): BCD
Sensor power supply
10 VDC 100 mA
0-20/
4-20 mA
5 VDC 100 mA
0-20/
N/C
4-20 mA
5 VDC 100 mA
N/C
0-20/
N/C
4-20 mA
0-5/1-5/
N/C
0-10 V
C1
C4
C6
+
0-5/1-5/
N/C
0-10 V
HH
Transistor Outputs
<T1> <T2>
COM C3
C3
Sensor power supply +
linear output
0-5/1-5/
N/C
0-10 V
C2
Relay Outputs
<C2>
1 2 3 4 5
PASS
1: V− (Power supply cable: Black)
2: CAN L (Communications cable: Blue)
3: Shield
4: CAN H (Communications cable: White)
5: V+ (Power supply cable: Red)
Applicable Connector:
HR31-5.08P-5SC (01)
(HIROSE ELECTRIC CO., LTD.)
* Attach the provided crimp terminals.
Applicable Connector (Sold separately)
HDR-E50MAG1
(HONDA TSUSHIN KOGYO CO., LTD.)
Special Cable (Sold separately)
K32-BCD (OMRON)
(HDR-E50MAG1 with 0.3-m cable)
The BCD COMMON is shared.
The pins indicated in the above diagram
as blank (white) boxes have been removed.
*Only one of the following can be used for each Digital Indicator: communications, BCD, or DeviceNet.
Sensor power supply
B1
B2
Contact output
N/C
B4
<K33-B>
12 VDC 80 mA
10 VDC 100 mA
5 VDC 100 mA
<K33-E>
Sensor power supply
B3
+
−
B5
B6
5V
<K33-A>
SD
B (+) SD
B1
A (−)
RD
A (−)
RD
A (−) RD
B2
B (+)
SG
B (+)
SG
B (+) SG
B3
A (−)
N/C
A (−)
N/C
A (−) N/C
5 VDC 100 mA
10 VDC 100 mA
10 VDC 100 mA
B4
−
RS-485 RS-232C RS-485 RS-232C RS-485 RS-232C
<K33- <K33<K33- <K33<K33- <K33FLK3E> FLK1E> FLK3B> FLK1B> FLK3A> FLK1A>
B5
B6
Sensor power supply
B (+)
12 VDC 80 mA
SD
12 VDC 80 mA
B (+)
5 VDC 100 mA
Sensor power supply +
communications
+
Transistor Output
(NPN Open Collector)
HH
HH
H
H
L
L
LL
LL
PASS
PASS
Safety Standards Conformance
• Always use a EN/IEC-compliant power supply with reinforced insulation or
double insulation for the DeviceNet power supply.
• The product must be used indoors for the above applicable standards to
apply.
• The K3HB-XVA@@ complies with UL standards when the applied input
voltage is within the range 0 to 150 VAC.
10
K3HB-V
E Analog Input
Process Indicator
K3HB-X
Weighing Indicator
K3HB-V
Temperature Indicator
K3HB-H
Linear Sensor Indicator
K3HB-S
AC voltage only
E1 N/C
A, B
E1 N/C
E2
A
N/C
E2
E3
B
C
E3
B
E4
C
D
E4
C
E5
D
N/C
E5
D
COM
E6 COM
E1
A
N/C
E1 Input B
Current input
E2
E2 Input A
E3
A
Pt
E4
-
E3 COM
E4 Input A
Voltage input
E5
E5 Input B
B TC
E6 COM
B' +
E6 COM
N/C E6
D Event Input
• Use terminal pin D6 as the common terminal.
• Use NPN open collector or no-voltage contacts for event input.
PNP types are also available.
Models with Terminal Blocks
<K35-1><K35-3>
D1 TIMING
D2 S-TMR
12 V
S-TMR: D2
HOLD: D3
RESET: D4
ZERO: D5
D3 HOLD
4.7 kΩ
D4 RESET
12 V
TIMING
D5 ZERO
560 Ω
D1
750 Ω
3.9 kΩ
D6 COM
D6
Models with Connectors
<K35-2><K35-4>
1: TIMING
1
3: HOLD
5: ZERO
7: BANK4
9: BANK1 9
D6
COM
COM
2: S-TMR
4: RESET
6: COM
8: BANK2
10 10: COM
2
• Applicable Connector (Sold separately)
XG4M-1030 (OMRON)
• Special Cable (Sold separately)
K32-DICN (OMRON)
(XG4M-1030 with 3 m cable)
BCD Output Cable
Model
Shape
K32-BCD
Pin arrangement
Connected device end
(PLC, display device, etc.)
K3HB end
1
COMMON
100
101
102
300 mm
38 mm
Cover:
HDR-E50LPA5
(manufactured by Honda Tsushin Co., Ltd.)
Connector: HDR-E50MAG1
(manufactured by Honda Tsushin Co., Ltd.)
46.5 mm
D-sub connector (37-pin female)
Cover:
17JE-37H-1A (manufactured by DDK)
Connector: Equivalent to 17JE-13370-02
(manufactured by DDK)
Stand:
17L-002A (manufactured by DDK)
103
104
1
2
4
8
1
2
4
8
1
2
4
8
1
2
4
8
1
2
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
4 104
8
OVER
DATA VALID
RUN
COMMON
REQUEST
MAX REQ.
MIN REQ.
HOLD
RESET
POLARITY
HH
H
PASS
L
LL
COMMON
Note: The BCD Output Cable has a D-sub plug. Cover: 17JE-37H-1A (manufactured by DDK); Connector: equivalent to 17JE-23370-02 (D1) (manufactured by DDK)
Special Cable (for Event Inputs with 8-pin Connector)
Model
Appearance
K32-DICN
9
10
1
2
Cable marking
3,000 mm
(3 m)
Wiring
Pin No.
1
2
3
4
5
6
7
8
9
10
Signal name
N/C
S-TMR
HOLD
RESET
N/C
COM
BANK4
BANK2
BANK1
COM
11
K3HB-V
■ Main Functions
Measurement
Timing Hold
Normal
Sampling Hold
• Continuously performs measurement and always outputs based on
comparative results.
• Holds the measurement at the rising edge of the TIMING signal.
Input
Sampling hold value
Input
H comparative set value
Measurement value
Measurement value
Time
Time
H output
Peak-to-peak Hold
Peak Hold/Bottom Hold
• Measures the maximum (or minimum) value in a specified period.
Input
TIMING ON
input OFF
Peak hold value
• Measures the difference between the maximum and minimum values in a specified period.
Input
Peak-to-peak value
(b2−a2)
(b1−a1)
Measurement value
Measurement value
b1
a1
Bottom hold value
'b2
'a2
Time
Time
TIMING ON
input OFF
TIMING ON
input OFF
Scaling
Previous Average Value Comparison
Scaling converts input signals in any way required before displaying
them. The values can be manipulated by shifting, inverting, or +/–
reversing.
Slight changes can be removed from input signals to detect only
extreme changes.
Display value
Display value
Display value 2
(dsp.a2)
Display value 2
(dsp.a2)
Display value 1
(dsp.a1)
Display value 1
(dsp.a1)
Input value 1 Input value 2
Input value
(inp.a2)
(inp.a1)
(Scaling)
Input value 2 Input value 1
(inp.a2)
(inp.a1)
Input value
(Reverse scaling)
Teaching
Settings for scaling can be made using the present measurement
values instead of inputting values with the SHIFT and UP Keys. This
is a convenient function for making settings while monitoring the
operating status, for calculating amounts by tare reduction (to
measure only the contents), or when the result should be zero but
the display is not zero for some reason.
Standby Sequence
Turns the comparative output OFF until the measurement value
enters the PASS range.
Average Processing
Average processing of input signals with extreme changes or noise
smooths out the display and makes control stable.
12
K3HB-V
■ Input Compensation/Display
Display Value Selection
Forced-zero
Forces the present value to 0. (Convenient for setting reference values or deducting tares for weight measurement.)
The current display value can be selected from the present value, the
maximum value, and the minimum value.
Step Value
Tare Zero
Shifts the current value measured with a forced zero to 0 again. It is
possible to measure two or more compounds separately and then, by
releasing the tare zero and forced-zero, measure the combined total.
Zero-trimming
It is possible to specify (i.e., restrict) the values that the smallest displayed digit can change by. For example, if the setting is 2, the smallest digit will only take the values 0, 2, 4, 6, or 8 and if the setting is 5,
it will only take the values 0 or 5. If the setting is 10, it will only take
the value of 0.
Compensates for mild fluctuations in input signals due to factors
such as sensor temperature drift, based on OK (PASS) data at measurement. (This function can be used with sampling hold, peak hold,
or bottom hold.)
Zero-limit
Changes the display value to 0 for input values less than the set
value. It is enabled in normal mode only. (This function can be used,
for example, to stop negative values being displayed or to eliminate
flickering and minor inconsistencies near 0.)
Display
Zero-limit
setting
Input
Interruption Memory
• The minimum and maximum values when the power supply is
turned OFF can be saved if interruption memory is turned ON.
• If interruption memory is ON, the maximum and minimum values
after the last resetting will be displayed.
• If interruption memory is OFF, the maximum and minimum values
will be displayed after the power supply is turned ON (or after the
reset input is performed).
Display Refresh Period
The display refresh period can be lengthened to reduce flickering
and thereby make the display easier to read.
Display Color Selection
Values can be displayed in either red or green. With comparative output models, the display color can also be set to change according to
the status of comparative outputs (e.g., green to red or red to green).
Example) Setting: grn-r
Red
H
Green
P
100.05
110.00
Comparative set value L
L
110.01
110.00
Comparative set value H
99.87
110.00
Red
13
K3HB-V
■ Output
Comparative Output Pattern
Hysteresis
The output pattern for comparative outputs can be selected. In addition to high/low comparison with set values, output based on level
changes is also possible. (Use the type of output pattern appropriate
for the application.)
Prevents comparative output chattering when the measurement
value fluctuates slightly near the set value.
Comparative
set value HH
Comparative
set value H
Comparative
set value L
Comparative
set value LL
Standard Output
Measurement
Comparative
value
set value HH
Higher Comparative
set value H
Comparative
set value L
Hysteresis
Comparative set value H
Measurement
value
Higher
Level Output
Hysteresis
Comparative set value L
Comparative output H
Lower
Lower Comparative
set value LL
Output HH
ON Output HH
OFF Output H
Output H
Output PASS
Output PASS
Output L
Output L
Output LL
Output LL
Comparative
set value HH
Comparative
set value H
Comparative
set value L
Comparative
set value LL
Example: Comparative Output Pattern (Standard Output)
Zone Output
Comparative output L
ON
OFF
Startup Compensation Timer
Measurement can be stopped for a set time using external input.
Measurement
value
Higher
Output HH
Output H
Input
H comparative set value
Lower
ON
OFF
Time
Output PASS
Startup
compensation
time set time
H output
Output L
Output LL
H input
Output Logic
PASS Output Change
Reverses the output operation of comparative outputs for comparative results.
Comparative results other than PASS and error signals can be output
from the PASS output terminal.
■ Dimensions
101.2
91
Terminal cover (included)
Character Size for Main Display (mm)
PV display
SV display
120 min.
4.9
14.2
100
Panel Cutout Dimensions
3.5
(112)
7.6
75 min.
92+0.8
0
45+0.6
0
12
1.3
95*
2
96
48
44.8
Mounting Recommended Panel Thickness
1 to 8 mm.
Mount the product horizontally.
*DeviceNet models: 97 mm
Terminal: M3, Terminal Cover: Accessory
14
K3HB-V
■ Wiring Precautions
■ Mounting Method
• For terminal blocks, use the crimp terminals suitable for M3 screws.
• Tighten the terminal screws to the recommended tightening torque
of approx. 0.5 N⋅m.
• To prevent inductive noise, separate the wiring for signal lines from
that for power lines.
1. Insert the K3HB into the mounting cutout in the panel.
2. Insert watertight packing around the Unit to make the mounting
watertight.
Watertight
packing
Wiring
• Use the crimp terminals suitable for M3 screws shown below.
5.8 mm max.
5.8 mm max.
Unit Stickers
3. Insert the adapter into the grooves on the left and right sides of
the rear case and push until it reaches the panel and is fixed in
place.
Adapter
• Select the appropriate units from the unit sticker sheets provided
and attach the sticker to the Indicator.
■ LCD Field of Vision
Note: When using for meters, such as weighing meters, use the units
specified by regulations on weights and measures.
The K3HB is designed to have the best visibility at the angles shown
in the following diagram.
10°
30°
■ Rubber Packing
(Sold Separately)
K32-P1
If the rubber packing is lost or damaged, it can
be ordered using the following model number:
K32-P1.
(Depending on the operating environment
deterioration, contraction, or hardening of the
rubber packing may occur and so, in order to
ensure the level of waterproofing specified in
NEMA4, periodic replacement is
recommended.)
Note: Rubber packing is provided with the
Controller.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
15
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
 Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
 Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
 Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2012.9
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2012 All Right Reserved.