VOLGEN KTPS10

Volgen 10 Watt Series
Wall Mount Type
www.volgen.com
USA / Japan / Taiwan / Europe / U.K.
KTPS-□□□ □□ □
WA- UL AC Pin / E2- EU Pin / B2- UK Pin
Green Mode
O/P Current
Meet CEC, Energy Star & ERP Regulations
No Load Power Consumption Less Than 0.3W
O/P Voltage
Safety Approvals
Features:
■
■
■
■
100-240VAC Universal Input
Single Output to 10W
Regulated Output with Low Ripple Noise
Meets Safety Agency Requirements and Complies
EMI/EMS,
■ Modified and Custom Designs Available
■ 1 Year Warranty
Model
For USA- CB / UL / cUL / FCC / PSE / BSMI / LPS
For Europe- CB / GS / CE / LPS
For U.K.- CB / CE / LPS
Electrical
Topology
Switching Flyback
Dielectric Withstand
3000 VAC Primary - Secondary
Leakage Current
Watt
0.25mA @ 2 Pin
Meet Energy Star Level V &
Efficiency
ERP Stage 2
EMI Conduction & Radiation Compliance to EN55022 Class B
O/P Voltage
O/P Current
KTPS10-03320WA
3.3V
2.0A
6.60W
KTPS10-0452WA
4.5V
2.0A
9.00W
KTPS10-05020WA
5.0V
2.0A
10.00W
KTPS10-05026WA
5.0V
2.5A
12.50W
KTPS10-06020WA
6.0V
2.0A
12.00W
KTPS10-07514WA
7.5V
1.4A
10.50W
KTPS10-08413WA
8.4V
1.3A
10.92W
KTPS10-09012WA
9.0V
1.2A
10.80W
KTPS10-12010WA
12.0V
1.0A
12.00W
KTPS10-13508WA
13.5V
0.8A
10.80W
KTPS10-15008WA
15.0V
0.8A
12.00W
KTPS10-18006 WA
18.0V
0.66A
11.88W
Cooling
KTPS10-24005WA
24.0V
0.5A
12.00W
Mechanical
Harmonic Current
Compliance to EN61000-3-2,3
EMS Immunity
Compliance to EN61000-42,3,4,5,6,8,11
MTBF
50,000 Calculated Hours at 25ºC, by
MIL-HDBK-217F
Environmental
Operaturing Temperature
Storage Temperature
Relative Humidity
Input
0 to +40ºC
-20 to +80ºC
Operating: 20 to 80% RH
Storage: 10 to 90% RH
Natural Convection Cooling
U2 - L 72 x W 34 x H 59 (mm)
Voltage
100-240 VAC
Line Frequency
50-60Hz
Current
0.31A Max.
Protection
Internal Primary Current Fuse, Inrush Limiting
AC Inlet
WA for UL AC Pin (Side)
E2 for EU Pin
B2 for UK Pin
Case Dimensions
E2 - L 72 x W 34 x H 80 (mm)
B2 - L 72 x W 50 x H 72 (mm)
Weight
U2:126g / E2:128g / B2:130g (reference)
Output
Load Regulation
± 5% Typical
Ripple
1~2%V p-p Max. for Output Voltage@ Full Load
Transient Response
0.5mS for 50% Load Change Typical
Holdup Time
10mS @ Full Load
Protection
Short Circuit Protection/ Over Voltage
Protection/ Over Current Protection
DC Cord
22AWG / 20AWG / 18AWG
Ferrite Core
Yes
2