LAL2094-50 Broadband Access Transformer Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation RoHS Compliant Operating Temperature -40°C to 85°C Electrical Specifications @25℃ ℃ OCL: PIN 16-9= 200uH ±10% @ 10KHz/0.1V/Ser. (PIN 11-14 Short) Leakage Inductance: Interwinding Capacitance T.H.D PIN 16-9= 30uH Max. @ 100KHz/100mV (PIN 11-14,PIN 2-3,1-4 Short) PIN 16-9= 30uH Max. @ 100KHz/100mV ( PIN 11-14,PIN 7-6,5-8 Short) PIN 16-5= 80pF Max. @ 100KHz/100mV ( PIN 11-14,PIN 7-6 Short) PIN 16-1= 50pF Max. @ 100KHz/100mV ( PIN 11-14,PIN 2-3 Short) PIN 16-9 to PIN 1-4= -80dB Max. @ 30KHz/2V ( PIN 11-14,PIN 2-3 Short) PIN 16-9 to PIN 5-8= -80dB Max. @ 30KHz/2V ( PIN 11-14,PIN 7-6 Short) PIN 16-9 = 5.0 ohm Max. D.C.R PIN 1-4= 10 ohm Max. ( PIN 2-3 Short) Hi-POT : ( PIN 11-14 Short) PIN 5-8= 2.0 ohm Max. ( PIN 7-6 Short) PRI. – SEC. =1875VAC/60Hz/2Seconds/1mA PIN16-9 : PIN 1-4 = 1±2% :1 Turn Ratio: ( PIN 11-14,PIN 2-3 Short) PIN16-9 : PIN 5-8 = 3.8±2% :1 Dimensions (Units: mm) ( PIN 11-14,PIN 7-6 Short) Schematic LALXXXX LinkCom X DATE CODE G DOT PIN1 S Mark 1.LAL****----LAL2094 2. X----PRODUCT LINE 3. DATE CODE----YYWW There shall be no breakdown between winding 1,3,2,4,5,7,6,8 & 16,11,14 ,9 when tested according to ITU-TK.21:2003 Enhanced level 6kV, par. 2.1.1.b using the test procedures of K.44:2003. 2-1 Rev.B 4. G----RoHS