LAL2066-50 Broadband Access Transformer Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation and 250V working voltage RoHS Compliant Excellent THD performance Operating Temperature -40°C to 85°C Electrical Specifications @25℃ OCL: PIN 16-9= 200uH ±10% @ 10KHz/0.1V/Ser. PIN 16-9= 30uH Max. Leakage Inductance: @ 100Hz/100mV PIN 16-9= 30uH Max. @ 100Hz/100mV IInterwinding Capacitance PIN 16-1= 50 pF Max. @ 100KHz/100mV PIN 16-5= 80 pF Max. @ 100KHz/100mV PIN 16-9 to PIN 1-4= -80dB Max. @ 30KHz/2V T.H.D PIN 16-9 to PIN 5-8= -80dB Max. @ 30KHz/2V PIN 1-4 = 10 ohm Max. D.C.R: PIN 5-8 = 2.0 ohm Max. PIN 16-9 = 5.0 ohm Max. Hi-POT : PRI. – SEC. =1875VAC/60Hz/2Seconds/1mA PIN16-9 : PIN 1-4 = 1±2% :1 Turn Ratio: PIN16-9 : PIN 5-8 = 3.8±2% :1 Dimensions (Units: mm) 3.40 3.40 X DATE CODE G F 19.0 14.4±0.5 LinkCom 14.0 Rx LAL**** 1.70 C 13.5±0.5 A 12.6±0.5 11 14 7 6 1.00 SUGGESTED PAD LAYOUT 16 3 2 4 5 Tx 1.7±0.3 PIN1 PRI 1 1.70 0.7TYP. 0.5TYP. 13.5±0.5 G SEC 5.10 5.1±0.3 3.4±0.3 Schematic 8 9 Mark 12.5 +1.00 -0.50 1.LAL****----LAL2066 2. X----PRODUCT LINE B 0.3 +0.15 -0.10 3. DATE CODE----YYWW Form Ver. A D 13.0±0.5 15.5±0.5 E 17.0 +1.0 -0.5 4. G----RoHS LINE