LINKCOM LAL2066-50

LAL2066-50
Broadband Access Transformer
Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation and
250V working voltage
RoHS Compliant
Excellent THD performance
Operating Temperature -40°C to 85°C
Electrical Specifications @25℃
OCL:
PIN 16-9= 200uH ±10% @ 10KHz/0.1V/Ser.
PIN 16-9= 30uH Max.
Leakage
Inductance:
@ 100Hz/100mV
PIN 16-9= 30uH Max. @ 100Hz/100mV
IInterwinding
Capacitance
PIN 16-1= 50 pF Max.
@ 100KHz/100mV
PIN 16-5= 80 pF Max.
@ 100KHz/100mV
PIN 16-9 to PIN 1-4= -80dB Max. @ 30KHz/2V
T.H.D
PIN 16-9 to PIN 5-8= -80dB Max. @ 30KHz/2V
PIN 1-4 = 10 ohm Max.
D.C.R:
PIN 5-8 = 2.0 ohm Max.
PIN 16-9 = 5.0 ohm Max.
Hi-POT :
PRI. – SEC. =1875VAC/60Hz/2Seconds/1mA
PIN16-9 : PIN 1-4 = 1±2% :1
Turn Ratio:
PIN16-9 : PIN 5-8 = 3.8±2% :1
Dimensions (Units: mm)
3.40
3.40
X DATE CODE G
F
19.0
14.4±0.5
LinkCom
14.0
Rx
LAL****
1.70
C
13.5±0.5
A
12.6±0.5
11
14
7
6
1.00
SUGGESTED PAD LAYOUT
16
3
2
4
5
Tx
1.7±0.3
PIN1
PRI
1
1.70
0.7TYP.
0.5TYP.
13.5±0.5
G
SEC
5.10
5.1±0.3
3.4±0.3
Schematic
8
9
Mark
12.5
+1.00
-0.50
1.LAL****----LAL2066
2. X----PRODUCT LINE
B
0.3
+0.15
-0.10
3. DATE CODE----YYWW
Form Ver. A
D
13.0±0.5
15.5±0.5
E 17.0 +1.0
-0.5
4. G----RoHS
LINE