ETC 228002

AXIAL LEAD AND CARTRIDGE FUSES
DESIGNED TO IEC STANDARD
5 x 20 mm Time Lag Fuse (Slo-Blo
®
Type Fuse)
D
®
®
V
E
• Designed to International (IEC) Standards for use globally.
• Meets the IEC 127-2, Sheet 3 specification for Time Lag
Fuses.
• Available in Cartridge and Axial Lead Form.
• Available in ratings of 0.032 to 10 amperes.
ELECTRICAL CHARACTERISTICS:
% of Ampere
Rating
150%
210%
275%
400%
1000%
Ampere
Rating
.032 – .100
.125 – 6.3
.032 – .100
.125 – 6.3
.032 – .100
.125 – 6.3
.032 – .100
.125 – 6.3
.032 – .100
.125 – 6.3
Opening
Time
60 minutes, Minimum
60 minutes, Minimum
2 minutes, Maximum
2 minutes, Maximum
0.2 sec., Min.; 10 sec. Max.
0.6 sec., Min.; 10 sec. Max.
.04 sec., Min.; 3 sec. Max.
.15 sec., Min.; 3 sec. Max.
.01 sec., Min.; 0.3 sec. Max.
0.02 sec., Min.; 0.3 sec. Max.
AGENCY APPROVALS: Sheet III IEC 127:* SEMKO, VDE
approved thru 6.3 amps. BSI approved 0.08-6.3 amps.
Recognized under the Components Program of
Underwriters Laboratories and recognized by CSA.
218 000 Series
213 000 Series
228 000 Series
223 000 Series
.635
(.025")
5
(.197")
20
(.787")
5.25
(.207")
20.24
(.797")
40
(1.58")
Average Time Current Curves for 218/228
.032A
.040A
.050A
.063A
.080A
.100A
.125A
.160A
.200A
.250A
.315A
.400A
.500A
.630A
.800A
1A
1.25A
1.6A
2A
2.5A
3.15A
4A
5A
6.3A
8A
10A
15A
VOLTAGE RATING: 250 VAC
INTERRUPTING RATINGS: 35 amperes or 10 x rated
current; whichever is greater.
100
ORDERING INFORMATION:
For axial leaded change 218 to 228 and 213 to 223.
Ampere
Rating
.032
.040
.050
.063
.080
.100
.125
.160
.200
.250
.315
.400
.500
.630
.800
1
1.25
1.6
2
2.5
3.15
4
5
6.3
8
10
15
218.032
218.040
218.050
218.063
218.080
218.100
218.125
218.160
218.200
218.250
218.315
218.400
218.500
218.630
218.800
218 001
218 1.25
218 01.6
218 002
218 02.5
218 3.15
218 004
218 005
218 06.3
218 008
218 010
218 015
213/223 Surge Withstand
Nominal
Nominal
Resistance Melting I2t
Cold Ohmns
A2Sec.
58.45
35.70
23.30
18.1
12.6
8.95
4.41
2.44
1.60
1.05
0.848
0.535
0.370
0.275
0.073
0.055
0.042
0.032
0.029
0.022
0.017
0.013
0.010
0.0075
0.0059
0.0045
0.0030
0.00305
0.0055
0.0071
0.012
0.0265
0.0495
0.150
0.225
0.350
0.555
1.14
1.35
2.90
4.80
1.99
3.33
5.80
10.61
14.80
23.85
39.20
70.95
114.0
204.0
350.5
583.0
1441.0
Cartridge
Catalog
Number
–
–
–
–
–
–
–
–
–
–
–
–
–
–
0213.800
0213 001.
0213 1.25
0213 01.6
0213 002.
0213 02.5
0213 3.15
0213 004.
0213 005.
0213 06.3
–
–
Nominal Nominal
Resistance Melting
Cold Ohms I2t A2Sec.
–
–
–
–
–
–
–
–
–
–
–
–
–
–
0.165
0.117
0.081
0.055
0.044
0.030
0.022
0.017
0.011
0.08
–
–
* IEC Standards for 5x20 fuses do not include ratings above 6.3A.
56
–
–
–
–
–
–
–
–
–
–
–
–
–
–
9.42
19.20
27.15
44.2
92.7
138.0
226.5
202
314
600
–
–
10
TIME IN SECONDS
218/228
Cartridge
Catalog
Number
1
0.1
0.01
0.001
0.05 0.1
1
10
CURRENT IN AMPERES
100
Please contact Littelfuse for Average Time Current Curve
for 213/223 surge withstand.
500