PANASONIC LH2H-FE-HMK

LH2H
LH2H
Hour Meters
DIN HALF SIZE
HOUR METER
Features
5. Battery Replacement Easy on
Environment
To replace battery simply remove body
for the one-touch installation type, and
remove battery lid for the installation
frame type.
6. Screw Terminals Designed for
Safety
Built in finger protection.
7. Panel Covers Replacable
(Standard color is ash gray.)
Change the panel design by replacing
with a black panel cover.
8. Conforms to IP66 Protective
Construction (Only installation frame
type.) (Front panel surface)
9. Input Methods
1) Non-voltage input method
2) Voltage input method
3) Free voltage input method
10. Backlight Type Added to Series
and Now 2-color Switchable (green/
red)
Easy viewing even in dark places and
switchable between green and red
(Voltage input type).
11. Compliant with UL, c-UL and CE
marking.
1. 8.7 mm Character Height
(previously 7 mm .343 inch)
Easy-to-read character height increased
from 7 mm to 8.7 mm .276 inch to .343
inch.
Panel mounting type
One-touch installation type
8.7mm
.343inch
2. Plenty of Digits
7 digits
Panel mounting type
Installation frame type
3. Select by switch between two time
ranges in a single meter.
0 to 999999.9h/0 to 3999d23.9h switchable
0 to 999h59m59s/0 to 9999h59.9m switchable
4. Panel Mounting Type Features 2
Installation Methods
Comes with very easy one-touch
installation type and also installation
frame type that uses the frame on the
timer/counter. Choose a method that
suits the application.
PC board mounting type
RoHS Directive compatibility information
http://www.nais-e.com/
Product chart
Type
Installation type
Panel
mounting
type
Non-voltage input type
Standard type
Voltage input type
(4.5 to 30 V DC)
Free voltage input type
(24 to 240 V AC/DC)
Backlight type
Voltage input type
(4.5 to 30 V DC)
One-touch installation type
Installation frame type
—
—
—
PC board mounting type
Product types
1. Panel mounting type
1) One-touch installation type
1 Standard type
No. digits
7 digits
Measurement time range
0 to 999999.9h/0 to 3999d23.9h switchable
0 to 999h59m59s/0 to 9999h59.9m switchable
0 to 999999.9h/0 to 3999d23.9h switchable
0 to 999h59m59s/0 to 9999h59.9m switchable
0 to 999999.9h/0 to 3999d23.9h switchable
0 to 999h59m59s/0 to 9999h59.9m switchable
Front reset
Input method
Non-voltage input type
Yes
Voltage input type (4.5 to 30 V DC)
Free voltage input type (24 to 240 V AC/DC)
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Part No.
LH2H-FE-DHK
LH2H-FE-HMK
LH2H-FE-DHK-DL
LH2H-FE-HMK-DL
LH2H-FE-DHK-FV
LH2H-FE-HMK-FV
LH2H
2 Backlight type
No. digits
7 digits
Measurement time range
0 to 999999.9h/0 to 3999d23.9h switchable
0 to 999h59m59s/0 to 9999h59.9m switchable
Front reset
Yes
Input method
Voltage input type (4.5 to 30 V DC)
Part No.
LH2H-FE-DHK-DL-B
LH2H-FE-HMK-DL-B
2) Installation frame type
1 Standard type
No. digits
7 digits
Measurement time range
0 to 999999.9h/0 to 3999d23.9h switchable
0 to 999h59m59s/0 to 9999h59.9m switchable
0 to 999999.9h/0 to 3999d23.9h switchable
0 to 999h59m59s/0 to 9999h59.9m switchable
0 to 999999.9h/0 to 3999d23.9h switchable
0 to 999h59m59s/0 to 9999h59.9m switchable
Front reset
Input method
Non-voltage input type
Yes
Voltage input type (4.5 to 30 V DC)
Free voltage input type (24 to 240 V AC/DC)
Part No.
LH2H-F-DHK
LH2H-F-HMK
LH2H-F-DHK-DL
LH2H-F-HMK-DL
LH2H-F-DHK-FV
LH2H-F-HMK-FV
2 Backlight type
No. digits
7 digits
Measurement time range
0 to 999999.9h/0 to 3999d23.9h switchable
0 to 999h59m59s/0 to 9999h59.9m switchable
Front reset
Yes
Input method
Voltage input type (4.5 to 30 V DC)
Part No.
LH2H-F-DHK-DL-B
LH2H-F-HMK-DL-B
2. PC board mounting type
No. digits
7 digits
Measurement time range
0 to 999999.9h
0 to 9999h59.9m
Front reset
No
Input method
Non-voltage input type
Part No.
LH2H-C-H-N
LH2H-C-HM-N
Specifications
1. Panel mounting type
Type
Item
No. digits
External power supply
Measurement time range
Min. input signal width
Input method (signal)
Start
input
Input impedance
Residual voltage
Min. input signal width
Input method (signal)
Reset
input
Input impedance
Residual voltage
Display method
Breakdown voltage (initial)
Insulation resistance (initial)
Backlight power
Protective construction (Note)
Accessories (Note)
Battery life
Standard type
Non-voltage input
Backlight type
Standard type
Voltage input
Free voltage type
7 digits
Not required (built-in battery)
0 to 999999.9h/0 to 3999d23.9h (Switchable by switch)
0 to 999h59m59s/0 to 9999h59.9m (Switchable by switch) Separate product type
200 ms
High level:
Non-voltage input using
High level: 4.5 to 30 V DC
24 to 240 V AC/DC
contacts or open collector
Low level: 0 to 2 V DC
Low level:
connection
0 to 2.4 V AC/DC
When shorted:
Max. 10 kΩ
Approx. 4.7 kΩ
—
When open:
Max. 750 kΩ
Max. 0.5 V
—
—
100 ms
Non-voltage input using
Non-voltage input using
High level: 4.5 to 30 V DC
contacts or open collector
contacts or open collector
Low level: 0 to 2 V DC
connection
connection
When shorted:
When shorted:
Max. 10 kΩ
Max. 10 kΩ
Appox. 4.7 kΩ
When open:
When open:
Max. 750 kΩ
Max. 750 kΩ
Max 0.5 V
—
Max. 0.5 V
7-segment LCD
7-segment LCD
7-segment LCD
With green/red backlight
Between charged and
Between charged and uncharged parts: 1,000 V AC for 1 minute.
uncharged parts:
2,000 V AC for 1 minute.
Min. 100 MΩ (measured at 500 V DC) Measurement location same as for break down voltage.
—
24 V DC (±10%)
—
IEC Standard IP66 (only panel front: when using rubber gasket)
Rubber gasket, mounting bracket
10 years (at 25°C 77°F)
Note) Only for installation frame type.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
LH2H
2. PC board mounting type
Type
Item
Input method
No. digits
Rated operation voltage
Allowable operation voltage range
Current consumption
Measurement time range
Min. input signal width
Input method
Start
input
Input impedance
Reset
input
Residual voltage
Min. input signal width
Input method
Input impedance
Residual power
Break down voltage (initial)
Insulation resistance (initial)
PC board mounting type
Non DC voltage input
7 digits
3 V DC
2.7 to 3.3 V DC
Max. 20 µA (max. 200 µA during reset input)
0 to 999999.9h
0 to 9999h59.9m
200 ms
Non-voltage input using contacts or open collector connection
When shorted: Max. 10 kΩ
When open: Max. 750 kΩ
Max. 0.5 V
10 ms
Non-voltage input using contacts or open collector connection
When shorted: Max. 10 kΩ
When open: Max. 750 kΩ
Max. 0.5 V
Between charged and uncharged parts: 1,000 V AC for 1 minute.
Min. 100 MΩ (measured at 500 V DC) Measurement location same as for break down voltage.
3. Common
Type
Panel mounting/PC board mounting types
Item
Time accuracy
±100 ppm (25°C 77°F)
10 to 55 Hz (1 cycle/min.), single amplitude: 0.15 mm (10 min. on 3 axes)
10 to 55 Hz (1 cycle/min.), single amplitude: 0.375 mm (1 hr. on 3 axes)
Min. 98 m/s2 (4 times on 3 axes)
Min. 294 m/s2 (5 times on 3 axes)
–10 to +55°C +14 to +131°F (without frost or dew)
–25 to +65°C –13 to +149°F (without frost or dew)
35 to 85% RH (non-condensing)
Functional
Vibration resistance
Destructive
Functional
Shock resistance
Destructive
Operation temperature
Storage temperature
Ambient humidity
Applicable standard
Safety standard
EN61010-1
(EMI)EN61000-6-4
Radiation interference electric field strength
Noise terminal voltage
(EMS)EN61000-6-2
Static discharge immunity
Pollution Degree 2/Overvoltage Category III
EN55011 Group1 ClassA
EN55011 Group1 ClassA
EN61000-4-2
EMC
RF electromagnetic field immunity
EN61000-4-3
EFT/B immunity
Conductivity noise immunity
Power frequency magnetic field immunity
EN61000-4-4
EN61000-4-6
EN61000-4-8
4 kV contact
8 kV air
10 V/m AM modulation (80 MHz to 1 GHz)
10 V/m pulse modulation (90 MHz)
2 kV (power supply line)
10 V/m AM modulation (0.15 MHz to 80 MHz)
30 A/m (50 Hz)
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
LH2H
Part names
1. Front reset button
Reset the elapsed time. It does not work
when the lock switch is ON. Be aware
that battery life will decrease if this switch
is used frequently.
2. Lock switch (Refer to chart on
right.)
Disable the front reset button.
HOUR METER
h
RESET
m
Time range switch
s
LH2H
Front reset button
Time unit seal
Lock switch
Note) Turn ON at the LCD side (reset disabled) and
OFF at the terminal block side (reset enabled).
3. Time range switch (See chart on
right).
Switch the time range.
0 to 999999.9h/0 to 3999d23.9h
Note) Always press the front reset button when
operating the time range switch.
4. Time unit sticker
Unit seals are included in the package.
Affix them in accordance with the time
range.
0 to 999h59m59s/0 to 9999h59.9m
(Terminal block side)
OFF❇
(LCD side)
ON
Lock switch
(Unit display 1)
(Terminal block side)
0 to 999999.9h❇ (Terminal block side)
0 to 9999h59.9m❇
0 to 3999d23.9h
0 to 999h59m59s
Count speed
switch
(Unit display 2)
(LCD side)
(LCD side)
Notes) 1. ❇Default setting when shipped.
2. Make the switch setting before installing to panel.
Dimensions
mm inch
General tolerance: ±1.0 ±.039
1. Panel mounting type
• External dimensions
1) One-touch installation type
• Panel installation diagram
44.8
1.764
M3.5
M.138
Panel (1 to 4.5mm
.039 to .177inch
thickness)
54.4
2.142
Rubber spacer
Note) When installing to a 4.5 mm .177 inch thick panel, remove the rubber spacer
first.
10.4
.409
(44)
(1.732)
5
.197
48
1.890
HOUR METER
22
.866
24
.945
RESET
LH2H
7
.276
Reset button
When installing the one-touch installation type model, make sure
that the installation spring does not pinch the rubber gasket.
To prevent the installation spring
from pinching the rubber gasket:
1. Set the rubber gasket on both
ends of the installation spring
(left and right).
2. Confirm that the installation
spring is not pinching the rubber
gasket, and then insert and fix the
installation spring in place from the
rear of the timer unit.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
LH2H
2) Installation frame type
• Panel mounting diagram
44.8
1.764
Mounting frame
ATH3803 (included)
Mounting screws
(found on mounting bracket)
M3.5
M.138
54.4
2.142
37
1.457
Rubber gasket
ATH3804 (included)
Panel
(1 to 4.5mm .039 to .177inch thickness)
10.4
.409
44
1.732
48
1.890
5
.197
HOUR METER
22
.866
24
.945
RESET
LH2H
7
.276
Reset button
• Panel cut-out dimensions
• For connected installation (sealed installation)
(Only installation frame type.)
The standard panel cut-out is shown below.
Use the mounting frame (ATH3803) and the rubber packing (ATH3804).
(Only installation frame type.)
22.2+0.5
0
.874+.020
0
A
A=(48×n-2.5)+1.0
0
A=(1.890×n-.098)+.039
0
60 min.
2.362 min.
45+0.5
0
1.772+.020
0
Notes) 1. Suitable installation panel thickness is 1 to 4.5 mm .039 to .177 inch.
2. Waterproofing will be lost when installing repeatedly (sealed installation).
+0.5
0
+.020
0
22.2
.874
• Terminal layout and wiring diagrams
1) Standard type
Non voltage input type
Start input
Voltage input type
Start input
+V
Reset input
1
2
3
1
4
Free voltage input type
Reset input
+V
2
3
4
Start input
or
0V
0V
W-R are connected internally.
2) Backlight type
Voltage input type
Start input
+V
Reset input
+V
<When green>
0V
+V
5
1
2
<When red>
5
3
4
1
6
0V
Backlight
2
5
3
4
1
6
2
3
4
6
0V
0V
+V
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Reset input
1
2
3
4
LH2H
General tolerance: ±1.0 ±.039 mm inch
2. PC board mounting type
• External dimensions
PC board pattern (BOTTOM VIEW)
33.02±0.3
1.300±.012
5.08±0.3
.200±.012
0.6±0.1
.024±.004
5.08±0.3
.200±.012
Mounting area
2.54
.100
DIP switch × 8
1.9
.075
2.54
.100
3.3±0.3
.130±.012
15.24 Connection sockets
.600 28 pin DIP terminal
8-0.8 dia.
8-.031 dia.
43.4
1.709
0.5±0.3
.020±.012
17.3
.681
5.19
.204
15.24±0.3
.600±.012
19
.748
1.9
5.19 .075
.204
5.08
.200
5.08
.200
33.02
1.300
HOUR METER LH2H
General tolerance: ±0.1 ±.004
0.3±0.1
.012±.004
Note: The AXS212811K is recommended as a compatible connection socket.
• Terminal layout and wiring diagrams
Start input
15 17
26 28
14 12
3
Reset input
1
Q-E, }-w, e-t and S-F are connected internally.
An external power supply is required.
Input method
1. Standard type
Non-voltage input type
Panel mounting type
Contact input
Start
input
1
2
3
4
PC board mounting type
Transistor input
Contact input
NPN transistor
Transistor input
NPN transistor
Reset
input
Start
input
1
2
3
Reset
input
4
0V
(W and R are connected internally.)
Start
input
15
17
26
28
14
12
3
1
Reset
input
Start
input
15
17
26
28
14
12
3
1
Reset
input
0V
(W and R are connected internally.)
3V DC
3V DC
Notes) 1. When using contact input, since current flow is small from terminals 1 and 3 on the panel mounting type and terminals e to t and S to F on the PC board
mounting type, please use relays and switches with high contact reliability.
2. When using transistor input, use the following as a guide for which transistors (Tr) to use for inputting. (Collector withstand voltage Q 50 V, leakage current < 1 µA)
Voltage input type
Transistor input
+V
Start
input
Reset
input
1
2
3
4
+V
Start
input
1
2
3
4
Free voltage input type
PNP transistor
+V
+V
Reset
input
Start
input
1
2
3
4
Reset
input
1
or
or
2
3
4
or
Reset input
NPN transistor
Start input
Contact input
Notes) 1. 2 and 4. (The input and reset circuits are functionally insulated.)
2. When using transistor (Tr) input, use the right as a guide. (Collector withstand voltage Q 50 V, leakage current < 1 µA)
3. Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input
terminal, can cause damage to the internal elements.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
LH2H
2. Backlight type
Voltage input type
Transistor input
Contact input
NPN transistor
+V
Start
input
Reset
input
5
1
2
3
Backlight connection
PNP transistor
+V
+V
Green
+V
Red
24V DC
Start
input
1
2
3
Reset
input
4
Start
input
4
6
5
1
2
3
4
6
Reset
input
5
1
2
6
5
3
4
1
2
6
3
4
24V DC
Notes) 1. Do not reverse the polarities when connecting the DC voltage for the backlight.
2. 2 and 4. (The input and reset circuits are functionally insulated.)
3. When using transistor (Tr) input, use the right as a guide. (Collector withstand voltage Q 50 V, leakage current < 1 µA)
4. Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input
terminal, can cause damage to the internal elements.
Explanation of operation
1. Time measuring takes place when the
start input is ON.
2. When the elapsed (measured) time
reaches full scale it returns to “0”, and
then measuring starts again from “0”.
3. When reset input is ON, the display
becomes “0”. You cannot measure during
reset input.
For PC board mounting type the display
disappears while the reset input is ON;
however, the display reads “0” when the
reset input turns OFF.
4. Press the front reset button if you want
to perform a manual reset (for panel
installation type)
ON
Start input
ON
OFF
ON
Reset input
OFF
Full scale
PC board type
Elapsed time
0
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
LH2H
Cautions for use
1. Non-voltage input type
For both panel mounting and PC
board mounting types
1) Never apply voltage to the non-voltage
input type. This will damage the internal
elements.
2) Since the current flow is very small
from the start input and reset input
terminals (1 and 3 on the panel
mounting type and terminals e to t and
S to F on the PC board mounting type)
please use relays and switches with high
contact reliability. When inputting with an
open collector of a transistor, use a
transistor for small signals in which ICBO
is 1 µA or less and always input with no
voltage.
3) When wiring, try to keep all the input
lines to the start and reset inputs as short
as possible and avoid running them
together with high voltage and power
transmission lines or in a power conduit.
Also, malfunctions might occur if the
floating capacitance of these wires
exceeds 500 pF (10 m 32.808 ft. for
parallel wires of 2 mm2). In particular,
when using shielded wiring, be careful of
the capacitance between wires.
PC board mounting type
1) For external power supply use
manganese dioxide or lithium batteries
(CR type: 3V).
2) Always reset after external power is
applied and confirm that the display
reads “0”.
3) Make the wiring from the battery to the
hour meter unit as short as absolutely
possible. Also, be careful of polarity.
4) Calculate battery life with the following
formula.
t = A/I
t: battery life [h]
I: LH2H current consumption [mA]
A: battery capacity until minimum
operation voltage is reached [mAh]
5) Hand solder to the lead terminal. Do
not dip solder. With the tip of the
soldering iron at 300°C 572°F perform
soldering within 3 seconds (for 30 to 60
W soldering iron).
2. Voltage input type
1) Be aware that applying more than 30 V
DC to start input terminals 1 and 2, and
reset input terminals 3 and 4 will cause
damage to the internal elements.
2) For external resetting use H level
(application of 4.5 to 30 V DC) between
reset terminals 3 and 4 of the rear
terminals. In this case, connect + to
terminal 3 and – to terminal 4. This is
the valid polarity; therefore, the hour
meter will not work if reversed.
3) When wiring, try to keep all the input
lines to the start and reset inputs as short
as possible and avoid running them
together with high voltage and power
transmission lines or in a power conduit.
Also, malfunctions might occur if the
floating capacitance of these wires
exceeds 500 pF (10 m 32.808 ft. for
parallel wires of 2 mm2).
3. Free voltage input type
1) Use start input terminals 1 and 2 for
free voltage input and reset terminals 3
and 4 for non-voltage input.
2) Be aware that the application of
voltage that exceeds the voltage range of
the H level to the start input terminal, and
the application of voltage to the reset
input terminal, can cause damage to the
internal elements.
3) Since the current flow is very small
from reset input terminal 3, please use
relays and switches with high contact
reliability.
4) When inputting a reset with an open
collector of a transistor, use a transistor
for small signals in which ICBO is 1 µA or
less and always input with no voltage.
5) To reset externally, short reset input
terminals 3 and 4 on the rear.
6) Input uses a high impedance circuit;
therefore, erroneous operation may occur
if the influence of induction voltage is
present. If you plan to use wiring for the
input signal that is 10 m or longer (wire
capacitance 120 pF/m at normal
temperature), we recommend the use of
a CR filter or the connection of a bleeder
resistor.
4. How to reset multiple panel
mounting type counters all at once
(input is the same for count)
Non-voltage input type
D
D
3 4
D
3 4
Tr
5. Backlight luminance
To prevent varying luminance among
backlights when using multiple Backlight
types, please use the same backlight
power supply.
24V DC
Voltage input type
3 4
3 4
3 4
+V
+V
or
2
5
2
2
6
6
24V DC
Red
6. Acquisition of CE marking
Please abide by the conditions below
when using in applications that comply
with EN 61010-1/IEC 61010-1
1) Ambient conditions
• Overvoltage category II, pollution level 2
• Indoor use
• Acceptable temperature and humidity
range: –10 to +55°C, 35 to 85%RH (with
no condensation at 20°C)
• Under 2000 m elevation
2) Use the main unit in a location that
matches the following conditions.
• There is minimal dust and no corrosive
gas.
• There is no combustible or explosive
gas.
• There is no mechanical vibration or
impacts.
• There is no exposure to direct sunlight.
• Located away from large-volume
electromagnetic switches and power
lines with large electrical currents.
3) Connect a breaker that conforms to
EN60947-1 or EN60947-3 to the voltage
input section.
4) Applied voltage should be protected
with an overcurrent protection device
(example: T 1A, 250 V AC time lag fuse)
that conforms to the EN/IEC standards.
(Free voltage input type)
7. Terminal connection
Tighten the terminal screws with a torque
of 0.8 N·cm or less.
Notes) 1. Use the following as a guide for choosing
transistors used for input (Tr).
Leakage current < 1 µA
2. Use as small a diode (D) as possible in the
forward voltage so that the voltage between
terminals 3 and 4 during reset input meets
the standard value (0.5 V).
( At IF = 20 µA, forward voltage 0.1 and
higher.)
R
Tr
5
Green
or
3 4
2
3 4
Note) Make sure that H (reset ON) level is at least 4.5
V.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.