LK-P VDE LK-P RELAYS 10 A Slim Power Relay FEATURES 24.0 .945 11.0 .433 25.0 .984 mm inch 4. Popular terminal pitch in AV equipment field 5. Space-saving slim type Base area: Width 11 × Length 24 mm Width .433 × Length .945 inch 6. Conforms to the various safety standards UL/CSA, VDE, TÜV and SEMKO, SEV approved 1. High switching capacity: 10 A 277V AC 2. High insulation resistance between contact and coil 1) Creepage distance and clearances between contact and coil: Min. 6 mm .236 inch (In compliance with IEC65) 2) Surge withstand voltage between contact and coil: 10,000 V or more 3. High noise immunity realized by the card separation structure between contact and coil SPECIFICATIONS Contact Characteristics Arrangement 1 Form A Initial contact resistance, max. Max. 100 mΩ (By voltage drop 6 V DC 1 A) Contact material Silver alloy Nominal switching 10 A 277 V AC, 5 A 30V DC capacity Max. switching power 2,770 V A, 150W Rating Max. switching (resistive load) 277 V AC, 30 V DC voltage Max. switching 10 A (AC), 5A (DC) current Mechanical 2 × 106 (at 180 cpm) Expected life (min. operations) Electrical (at 20 cpm) 105 (at rated load) Coil Nominal operating power Max. operating speed Initial insulation resistance*1 Between open Initial *2 contacts breakdown Between contact and voltage coil Initial surge voltage between contact and coil*3 Operate time*4 (at nominal voltage) Release time (without diode)*4 (at nominal voltage) Temperature rise (at 70°C) Functional*5 Destructive*6 Shock resistance 530 mW Functional*7 Remarks Vibration resistance * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage" section. *2 Detection current: 10mA *3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981 *4 Excluding contact bounce time. *5 Half-wave pulse of sine wave: 11 ms; detection time: 10 µs *6 Half-wave pulse of sine wave: 6 ms *7 Detection time: 10 µs *8 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24). Destructive Conditions for operation, transport and storage*8 (Not freezing and condensing at low temperature) 20 cpm (at rated load) Min. 1,000 MΩ (at 500 V DC) 1,000 Vrms for 1 min. 4,000 Vrms for 1 min. Min. 10,000 V Approx. 7 ms (at 20°C 68°F) Approx. 2 ms (at 20°C 68°F) Max. 45°C with nominal coil voltage and at 10 A contact carrying current (resistance method) Min. 200 m/s2{approx. 20 G} Min. 1,000 m/s2{approx. 100 G} 10 to 55Hz at double amplitude of 1.5mm 10 to 55Hz at double amplitude of 1.5mm –40°C to +70°C –40°F to +158°F 5 to 85% R.H. Ambient temp. Humidity Air pressure 86 to 106 kPa Unit weight TYPICAL APPLICATIONS • Audio visual equipment TVs, VTRs • Office equipment LBP, CRT • Home appliances Refrigerator, Air conditioner 56 Approx. 12 g .42 oz ORDERING INFORMATION Ex. LKP 1a F – 12V Contact arrangement Protective construction Coil voltage(DC) 1a: 1 Form A F: Flux-resistant type 12, 24V UL/CSA, TÜV, SEMKO, TV-5 approved type is standard. Notes 1. Standard packing Carton: 100 pcs. Case: 500 pcs. 2. 5 V, 9 V, 18 V DC types are also available. Please consult us for details. LK-P TYPES AND COIL DATA (at 20°C 68°F) Part No. Nominal voltage, V DC LKP1aF-12V LKP1aF-24V 12 24 Pick-up voltage, V DC (max.) (Initial) 8.4 16.8 Drop-out voltage, V DC (min.) (Initial) 1.2 2.4 Coil resistance, Ω (±10%) 272 1,087 Nominal operating current, mA (±10%) 44.2 22.1 Nominal operating power, mW 530 530 Maximum allowable voltage, V DC (at 20°C 68°F) 15.6 31.2 DIMENSIONS mm inch PC board pattern (Bottom view) 2-0.9 dia 2-.035 dia 2-1.3 dia 2-.051 dia 16.5 .650 7.5 .295 Max. 25.0 .984 0.5 .020 0.5 dia. .020 dia. Max. 24.0 .945 16.5 .650 Tolerance: ±0.1 ±.004 4 .157 0.3 .012 1.65 .065 20.0 .787 Schematic (Bottom view) 0.4 .016 Max. 11.0 .433 1.0 .039 Dimension: Max. 1mm .039 inch: 1 to 3mm .039 to .118 inch: Min. 3mm .118 inch: 7.5 .295 20.0 .787 General tolerance ±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012 REFERENCE DATA 1. Max. switching power 2. Coil temperature rise 3. Ambient temperature characteristics and coil applied voltage Sample: LKP1aF-12V, 6 pcs. Point measured: coil inside Contact current: 5 A, 10 A Contact current: 10 A 60 220 Temperature rise, °C Contact current, A 55 10 1 50 20°C 10A 20°C 5A 45 70°C 10A 70°C 5A 40 35 Coil applied voltage, %V 100 Allowable ambient temperatures against % coil voltages (max. inside the coil temperature set as 115°C 239°F) 180 140 100 Cold start 30 60 Pick-up voltage 25 0 10 20 100 Contact voltage, V 0 100 120 Coil applied voltage, %V 20 0 10 20 30 40 50 60 70 80 Ambient temperature, °C 4. Life curve Operation frequency: 20 times/min. (ON/OFF = 1.5s: 1.5s) Ambient temperature: room temperature 100 Life, ×104 250V AC resistive load 10 1 0 2 4 6 8 10 Contact current, A 57 LK-P 5. Electrical life test (10 A 277 V AC, resistive load) Change of pick-up and drop-out voltage 45 10 Pick-up voltage 8 Max. 6 x Min. 4 Drop-out voltage Max. x Min. 2 0 0 5 No. of operations, ×104 10 Contact resistance, mΩ Contact welding detection and Miscontacting detection circuit Pick-up and drop-out voltage, V Circuit: 12V DC 50 12 Sample: LKP1aF-12V, 6 pcs. Operation frequency: 20 times/min. (ON/OFF = 1.5s: 1.5s) Ambient temperature: 20°C 68°F 277V AC Change of contact resistance 40 35 30 25 20 Max. 15 x 10 Min. 5 0 0 5 No. of operations, ×104 For Cautions for Use, see Relay Technical Information (Page 11 to 39). 58 10