FEATURES / BENEFITS p Fully modular linear arrays of ultra high brightness LEDs p Utilizes the latest 100+ lumen LUXEON® Rebel™ PWM SERIES LV LEDs for cool white, 100+ lumen for neutral white & 50+ lumen for warm white LINEAR MODULES p Onboard 350mA constant current driver runs off low voltage input p ETL listed to UL2108 standards p Choice of colour temperatures & optical patterns p >70% lumen maintenance @ 50,000 hours at max acceptable ambient temperature p Primary heatsinking included p Color binned for consistent color APPLICATION OPERATING CONDITIONS p Operating Ambient temperature -30ºC to +55ºC p Onboard driver model operates off 12-24VDC / 11-17VAC input p Max modules per run = 10 @ 12VAC, 16 @ 24VDC input p Typical power consumption 8.0W per module p Additional heatsinking required for optimal performance p Current draw 580mA @ 12VDC input* 290mA @ 24VDC input* p Linear lighting p Accent lighting p Flood lighting p Street & area lighting p General illumination *Note:- 750mA per unit required for initial start-up ORDERING INFORMATION MATERIALS / FINISH p Six premium LUXEON Rebel LEDs per module p Anodized cast aluminum heatsink p Dialight-Lumidrives optics (OPC 11 Series) p Onboard 350mA constant current driver p Required Entry Cable, Power Supply to 1st module (sold seperately): LML6-LV-CON-CAB Typical Colour (AA) Temperature Optic (BB) SP = 5 degree spot CW = 5000K - 6350K NW = 3800K - 4100K WW = 2850K - 3250K MD = 8 degree med. WD = 20 degree wide OV = 5X25 degree oval FR = 7 degree frosted spot *All angles are half divergence www.dialight.com Connectors LML6-LV-CON-CAB (sold separately) Entry cable, power supply to 1st module LML6-LV-M2M-CAB (ships w/ 1 in box) Connection cable (module to module) * Cables use AWG 20 wires MECHANICAL DIMENSIONS 11.7” x 1.498” x 0.585” (297.18mm x 38.05mm x 14.86mm) Mounting hole spacing = 3.22” [81.8mm]. Max screw size #8 Total length for “Z” units connected end to end = (Z x 11.7) - ((Z-1) x 0.25) (inches) (Z x 297.2) - ((Z-1) x 6.35) (mm) Top View Side View Example: 2 units total length = 23.15” [588.01] ASSEMBLY INFORMATION 1) Remove cover from module (Do not remove mask) 2) Connect LML6-LV-M2M-CAB quick connect cables between modules as indicated in the photo. If desired, insert 8/32 or M6 mounting screws in holes provided. 3) Wire between cables may be routed through end as indicated in photo or around side of module. 4) Connect LML6-LV-CON-CAB into front of first module. 5) Replace cover. 6) Connect leads on LML6-LV-CON-CAB to low voltage power supply. Red wire to +, black wire to - PHOTOMETRIC DATA IES 32 files available, consult factory Dialight reserves the right to make changes at any time in order to supply the best product possible. The most current version of this document will always be available at: www.dialight.com/Assets\Brochures_And_Catalogs\Illumination\MDEXLUMPWMLV.pdf MDEXLUMPWMLV_C www.dialight.com 2