AXIAL LEAD AND CARTRIDGE FUSES DESIGNED TO MEET UL/CSA STANDARDS 5 x 20 mm Fast-Acting Type U® L 1 ® • Designed to UL/CSA/ANCE 248 Standard. • Available in Cartridge and Axial Lead Format. • Available in ratings of 0.100 to 6 amperes. ELECTRICAL CHARACTERISTICS: % of Ampere Rating 110% 135% 200% Opening Time 4 hours, Minimum 1 hour, Maximum 1 second, Maximum AGENCY APPROVALS: Listed by Underwriters Laboratories and Certified by CSA. Approved by MITI from 1 through 5 amperes. ORDERING INFORMATION: Nominal Resistance Cold Ohms 8.40 5.75 3.15 2.25 1.60 1.08 0.455 0.318 0.263 0.195 0.153 0.106 0.0775 0.0600 0.0438 0.0348 0.0248 0.0185 0.0150 Nominal Melting I2t A2 Sec. 0.00160 0.00280 0.00890 0.0170 0.0330 0.0600 0.0710 0.115 0.160 0.260 0.480 1.12 2.08 2.72 5.59 8.62 17.60 28.15 48.60 235 000 Series 236 000 Series .635 (.025") 5 (.197") 20 (.787") 5.25 (.207") 20.24 (.797") 40 (1.58") Average Time Current Curves .100A .125A .200A .250A .300A .400A .500A .600A .700A .800A 1A 1.25A 1.6A 2A 2.5A 3A 4A 5A 6A Axial Lead Catalog Ampere Voltage Number Rating Rating 236.100 .100 250 236.125 .125 250 236.200 .200 250 236.250 .250 250 236.300 .300 250 236.400 .400 250 236.500 .500 250 236.600 .600 250 236.700 .700 250 236.800 .800 250 236 001 1 250 236 1.25 1.25 250 236 01.6 1.6 250 236 002 2 250 236 02.5 2.5 250 236 003 3 250 236 004 4 125 236 005 5 125 236 006 6 125 10000 1000 100 TIME IN SECONDS Cartridge Catalog Number 235.100 235.125 235.200 235.250 235.300 235.400 235.500 235.600 235.700 235.800 235 001 235 1.25 235 01.6 235 002 235 02.5 235 003 235 004 235 005 235 006 10 1 0.1 0.01 0.001 0.1 1 10 CURRENT IN AMPERES 100 1000 59