AGERE LU3X54FTL

Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Introduction
■
Autopolarity detection and correction
■
Adjustable squelch level for extended line length
capability (two levels)
■
Interfaces with IEEE 802.3u media independent
interface (MII) or a serial 10 Mbits/s 7-pin interface
■
On-chip filtering eliminates the need for external
filters
■
Half- and full-duplex operations
Configuration
The LU3X54FTL is a four-channel, single-chip complete transceiver designed specifically for dual-speed
10Base-T, 100Base-TX, and 100Base-FX repeaters
and switches. It supports simultaneous operation in
three separate IEEE standard modes: 10Base-T,
100Base-TX, and 100Base-FX. The LU3X54FTL
provides a 3.3 V or 5.0 V MII interface logic level.
Each channel implements:
■
10Base-T transceiver function of IEEE 802.3.
■
Physical coding sublayer (PCS) of IEEE 802.3u.
■
Physical medium attachment (PMA) of IEEE
802.3u.
■
Autonegotiation of IEEE 802.3u.
■
MII management of IEEE 802.3u.
■
Physical medium dependent (PMD) of IEEE 802.3.
The LU3X54FTL supports operations over two pairs
of unshielded twisted-pair (UTP) cable (10Base-T
and 100Base-TX), and over fiber-optic cable
(100Base-FX).
It has been designed with a flexible system interface
that allows configuration for optimum performance
and effortless design. The individual per-port interface can be configured as 100 Mbits/s MII, 10 Mbits/s
MII, 7-pin 10 Mbits/s serial, or bused mode.
Features
100 Mbits/s TX Transceiver
■
Compatible with IEEE 802.3u MII (clause 22), PCS
(clause 23), PMA (clause 24), autonegotiation
(clause 28), and PMD (clause 25) specifications
■
Scrambler/descrambler bypass
■
Encoder/decoder bypass
■
3-statable MII in 100 Mbits/s mode
■
Selectable carrier sense signal generation (CRS)
asserted during either transmission or reception in
half duplex (CRS asserted during reception only in
full duplex)
■
Selectable MII or 5-bit code group interface
■
Full- or half-duplex operations
■
Optional carrier integrity monitor (CIM)
■
On-chip filtering and adaptive equalization that
eliminates the need for external filters
100 Mbits/s FX Transceiver
■
10 Mbits/s Transceiver
■
Compatible with IEEE 802.3U 100Base-FX standard
Compatible with IEEE * 802.3 10Base-T standard
for twisted-pair cable
* IEEE is a registered trademark of The Institute of Electrical and Electronics Engineers, Inc.
Note: Advisories are issued as needed to update product information. When using this data sheet for design purposes, please contact
your Lucent Technologies Microelectronics Group Account Manager to obtain the latest advisory on this product.
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
Table of Contents
Contents
Page
Introduction................................................................................................................................................................ 1
Configuration........................................................................................................................................................... 1
Features .................................................................................................................................................................... 1
10 Mbits/s Transceiver ............................................................................................................................................ 1
100 Mbits/s TX Transceiver ..................................................................................................................................... 1
100 Mbits/s FX Transceiver ..................................................................................................................................... 1
General ................................................................................................................................................................... 4
Description ................................................................................................................................................................ 4
Bused MII Mode...................................................................................................................................................... 4
Clocking .................................................................................................................................................................. 5
FX Mode .................................................................................................................................................................6
Functional Block Diagrams ..................................................................................................................................... 7
Application Diagrams .............................................................................................................................................. 9
Block Diagrams .....................................................................................................................................................11
Pin Information ........................................................................................................................................................13
Pin Diagram for Normal MII Mode.........................................................................................................................13
Pin Diagram for Bused MII Mode ..........................................................................................................................14
Pin Maps ...............................................................................................................................................................15
Pin Descriptions ....................................................................................................................................................16
MII Station Management .........................................................................................................................................29
Basic Operations...................................................................................................................................................29
MII Management Frames ......................................................................................................................................29
Management Registers (MR) ................................................................................................................................30
Unmanaged Operations ........................................................................................................................................40
Mode Select ..........................................................................................................................................................40
Absolute Maximum Ratings (TA = 25 °C) ................................................................................................................41
Electrical Characteristics .........................................................................................................................................41
Timing Characteristics (Preliminary) .......................................................................................................................42
Outline Diagram.......................................................................................................................................................51
208-Pin SQFP.......................................................................................................................................................51
Ordering Information................................................................................................................................................52
Tables
Page
Table 1. LU3X54FTL Crystal Specifications ............................................................................................................ 6
Table 2. LU3X54FTL Pin Maps.............................................................................................................................. 15
Table 3. MII/Serial Interface Pins in Normal MII Mode (Four Separate MII Ports) ................................................. 16
Table 4. MII/Serial Interface Pins in Bused MII Mode ............................................................................................ 18
Table 5. MII Management Pins .............................................................................................................................. 22
Table 6. 10/100 Mbits/s Twisted-Pair (TP) Interface Pins....................................................................................... 22
Table 7. Miscellaneous Pins .................................................................................................................................. 23
Table 8. MII Management Frame Format............................................................................................................... 29
Table 9. MII Management Frames Field Descriptions............................................................................................ 29
Table 10. MII Management Registers (MR) ........................................................................................................... 30
Table 11. MR0—Control Register Bit Descriptions ................................................................................................ 31
Table 12. MR1—Status Register Bit Descriptions ................................................................................................. 32
Table 13. MR2, 3—PHY Identifier Registers (1 and 2) Bit Descriptions ................................................................ 33
Table 14. MR4—Autonegotiation Advertisement Register Bit Descriptions........................................................... 33
Table 15. MR5—Autonegotiation Link Partner (LP) Ability Register (Base Page) Bit Descriptions ....................... 34
Table 16. MR5—Autonegotiation Link Partner (LP) Ability Register (Next Page) Bit Descriptions ........................ 34
2
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Table of Contents (continued)
Tables
Page
Table 17. MR6—Autonegotiation Expansion Register Bit Descriptions..................................................................35
Table 18. MR7—Next-Page Transmit Register Bit Descriptions .............................................................................35
Table 19. MR28—Device-Specific Register 1 (Status Register) Bit Descriptions...................................................36
Table 20. MR29—Device-Specific Register 2 (100 Mbits/s Control) Bit Descriptions ............................................37
Table 21. MR30—Device-Specific Register 3 (10 Mbits/s Control) Bit Descriptions ..............................................38
Table 22. MR31—Device-Specific Register 4 (Quick Status) Bit Descriptions.......................................................39
Table 23. Output Pins .............................................................................................................................................40
Table 24. LU3X54FTL Modes.................................................................................................................................40
Table 25. Absolute Maximum Ratings ....................................................................................................................41
Table 26. Operating Conditions ..............................................................................................................................41
Table 27. dc Characteristics ...................................................................................................................................41
Table 28. MII Management Interface Timing (25 pF Load).....................................................................................42
Table 29. MII Data Timing (25 pF Load) .................................................................................................................43
Table 30. Serial 10 Mbits/s Timing for TPIN, CRS, and RX_CLK...........................................................................45
Table 31. Serial 10 Mbits/s Timing for TX_EN, TPOUT, CRS, and RX_CLK..........................................................45
Table 32. Serial 10 Mbits/s Timing for TX_EN, TPIN, and COL .............................................................................46
Table 33. Serial 10 Mbits/s Timing for RX_CLK, CRS, RXD, TX_CLK, TX_EN, and TXD (25 pF Load)................47
Table 34. Serial 10 Mbits/s Timing for RX_CLK and TX_CLK (25 pF Load) ..........................................................48
Table 35. 100 Mbits/s MII Transmit Timing .............................................................................................................49
Table 36. 100 Mbits/s MII Receive Timing..............................................................................................................50
Figures
Page
Figure 1. LU3X54FTL Device Overview...................................................................................................................7
Figure 2. LU3X54FTL Single-Channel Detail Functions ..........................................................................................8
Figure 3. Typical Single-Channel Twisted-Pair (TP) Interface ..................................................................................9
Figure 4. Typical Single-Channel Fiber-Optic Interface ..........................................................................................10
Figure 5. Smart 10/100 Mbits/s Bused MII Mode...................................................................................................11
Figure 6. Separate 10/100 Mbits/s Bused MII Mode ..............................................................................................12
Figure 7. LU3X54FTL Pinout for Normal MII Mode................................................................................................13
Figure 8. LU3X54FTL Pinout for Bused MII Mode .................................................................................................14
Figure 9. MDIO Input Timing..................................................................................................................................42
Figure 10. MDIO Output Timing .............................................................................................................................42
Figure 11. MDIO During TA (Turnaround) of a Read Transaction ..........................................................................43
Figure 12. MII Timing Requirements for LU3X54FTL ............................................................................................44
Figure 13. Serial 10 Mbits/s Timing for TPIN, CRS, and RX_CLK.........................................................................45
Figure 14. Serial 10 Mbits/s Timing for TX_EN, TPOUT, CRS, and RX_CLK........................................................45
Figure 15. Serial 10 Mbits/s Timing for TX_EN, TPIN, and COL ...........................................................................46
Figure 16. Serial 10 Mbits/s Timing for RX_CLK, CRS, RXD, TX_CLK, TX_EN, and TXD ...................................47
Figure 17. Serial 10 Mbits/s Timing Diagram for RX_CLK and TX_CLK ...............................................................48
Figure 18. 100 Mbits/s MII Transmit Timing ...........................................................................................................49
Figure 19. 100 Mbits/s MII Receive Timing ............................................................................................................50
Lucent Technologies Inc.
3
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
Features (continued)
■
Reuses existing twisted-pair I/O pins for compatible
fiber-optic transceiver pseudo-ECL (PECL) data:
— No additional data pins required
— Reuses existing LU3X54FTL pins for fiber-optic
signal detect (FOSD) inputs
■
Fiber mode automatically configures port:
— Disables autonegotiation
— Disables 10Base-T
— Enables 100Base-FX remote fault signaling
— Disables MLT-3 encoder/decoder
— Disables scrambler/descrambler
■
FX mode enable is pin- or register-selectable on an
individual per-port basis
— 10 Mbits/s repeater reference select
— Internal 20 MHz clock synthesizer
— FX mode select
■
Single 25 MHz crystal input or 25 MHz clock input,
optional 20 MHz clock input
■
Supports half- and full-duplex operations
■
Provides six status signals:
— Receive activity
— Transmit activity
— Full duplex
— Collision/jabber
— Link integrity
— Speed indication
■
Optional LED pulse stretching
■
Per-channel powerdown mode for 10 Mbits/s and
100 Mbits/s operation
■
Loopback for 10 Mbits/s and 100 Mbits/s operation
■
Internal pull-up or pull-down resistors to set default
powerup mode
General
■
Autonegotiation (IEEE 802.3u, clause 28):
— Fast link pulse (FLP) burst generator
— Arbitration function
■
Bused interfaces:
— Supports either separate 10 Mbits/s and
100 Mbits/s multiport repeaters (100 Mbits/s
MII and 10 Mbits/s serial data stream), or singlechip multispeed repeaters
— Connects ports to either the 10 Mbits/s or
100 Mbits/s buses controlled by autonegotiation
— Separate TX_EN, RX_EN, CRS, and COL pins for
each port
— Drivers on bused signal can drive up to eight
LU3X54FTLs (32 ports)
■
■
4
Supports the station management protocol and
frame format (clause 22):
— Basic and extended registers
— Supports next-page function
— Operates up to 12.5 MHz
— Accepts preamble suppression
— Maskable status interrupts
Supports the following management functions via
pins if MII station management is unavailable:
— Speed select
— Carrier integrity enable
— Encoder/decoder bypass
— Scrambler/descrambler bypass
— Full duplex
— No link pulse mode
— Carrier sense select
— Autonegotiation
■
0.35 µm low-power CMOS technology
■
208-pin SQFP
Description
Bused MII Mode
The LU3X54FTL has been designed for operation in
two basic system interface modes of operation:
■
Normal MII Mode (Four Separate MII Ports). The
separate mode provides four independent RJ-45 to
MII ports and is similar to having four independent
10/100 transceivers.
■
Bused MII Mode. This mode is designed specifically
for repeater applications to save pins. In bused
mode:
— Data from all of the ports operating at 100 Mbits/s
will be internally bused to system interface port A
(100 Mbits/s MII interface).
— Data from all of the ports operating at 10 Mbits/s
will be internally bused to system interface port B
(7-pin 10 Mbits/s serial interface).
The LU3X54FTL will automatically detect the speed of
each port (10 Mbits/s or 100 Mbits/s) and route the
data to the appropriate port.
Lucent Technologies Inc.
Data Sheet
July 2000
Description (continued)
The bused mode has two additional submodes of
operation:
■
Separate Bused MII Mode. This mode is designed
to operate with two independent repeater ICs, one
repeater operating at 100 Mbits/s and the other operating at 10 Mbits/s.
The bused interface allows each of the four transceivers to be connected to one of two system interfaces:
■
Port A: 100 Mbits/s MII interface.
■
Port B: 7-pin 10 Mbits/s serial interface.
This configuration allows 10/100 Mbits/s segment segregation or port switching with conventional multiport
shared-media repeaters.
Figure 6 shows a block diagram of this mode in
which separate pins (four of each) are used for
COL_10(4), COL_100(4), CRS_10(4), CRS_100(4),
RX_EN10(4), RX_EN100(4), TX_EN10 (4), and
TX_EN100(4).
The port speed configuration and connection to the
appropriate bused output is done automatically and is
controlled by autonegotiation.
The signals RX_CLK10, RXD_10, TX_CLK10, and
TXD_10 (all from ports A, B, C, and D) are internally
bused together and connected to MII port B.
Figure 3 shows how the LU3X54FTL single-channel
interfaces to the twisted pair (TP).
The signals TX_CLK25, TXD_100[3:0], TX_ER,
RX_CLK25, RXD_100[3:0], RX_DV, and RX_ER (all
from ports A, B, C, D) are internally bused together
and connected to MII port A.
The repeater ICs will enable the particular port to
which it will communicate by enabling the port with
TX_EN 10, TX_EN100, RX_EN10, or RX_EN100.
■
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Smart Bused MII Mode. This mode is used when
the LU3X54FTL is communicating with a single
(smart) 10/100 Mbits/s repeater IC, and allows the
use of the security feature.
Figure 5 shows a block diagram of the smart bused
mode of operation. In this mode, a common set of
pins is used for CRS_10/100[D:A],
RX_EN10/100[D:A], TX_EN10/100, and
COL_10/100.
Figure 1 gives a functional overview of the LU3X54FTL
while Figure 2 details its single-channel functions.
Clocking
The LU3X54FTL requires an internal 25 MHz clock and
a 20 MHz clock to run the 100Base-TX transceiver and
10Base-T transceiver.
These clocks can be supplied as follows:
■
As separate clock inputs: 25 MHz and 20 MHz.
■
The 20 MHz clock can be internally synthesized from
the 25 MHz clock.
■
The 25 MHz clock can also be internally generated
by an on-chip oscillator if an external crystal is supplied.
The LU3X54FTL will automatically detect if a 25 MHz
clock is supplied, or if a crystal is being used to generate the 25 MHz clock.
The 10 Mbits/s (7-pin 10 Mbits/s serial interface) signals are still routed to port B (RX_CLK10, RXD_10,
TX_CLK10, and TXD_10).
The 100 Mbits/s signals are still routed to port A
(TX_CLK25, TXD_100[3:0], TX_ER, RX_CLK25,
RXD_100[3:0], RX_DV, and RX_ER).
Lucent Technologies Inc.
5
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
Description (continued)
FX Mode
Either the on-chip 20 MHz clock synthesizer (default
clock) can be used, or H-DUPLED[A]/CLK20_SEL
(pin 198) can be pulled high (sensed on powerup and
reset) to select the external 20 MHz clock input.
Each individual port of the LU3X54FTL can be operated in 100Base-FX mode by selecting it through the
pin program option RXLED[D:A]/FX_MODE_EN[D:A],
or through the register bit (register 29, bit 0).
The crystal specifications for the device are listed in
Table 1, and the crystal circuit is shown in Figure 3 and
Figure 4.
When operating in FX mode, the twisted-pair I/O pins
are reused as the fiber-optic transceiver I/O data pins,
and the fiber-optic signal detect (FOSD) inputs are
enabled.
Table 1. LU3X54FTL Crystal Specifications
Figure 4 shows a typical FX port interface. Note that no
additional external components, excluding those
needed by the fiber transceiver, are required.
Parameter
Type
Frequency
Stability
Shunt Capacitor
Load Capacitor
Series Resistance
6
Requirement
Quartz Fundamental Mode
25 MHz
±25 ppm, 0—70 °C
7 pF
20 pF
<30 Ω
When a port is placed in FX mode, it will automatically
configure the port for 100Base-FX operation (and the
register bit control will be ignored) such that:
■
The far-end fault signaling option will be enabled.
■
The MLT-3 encoding/decoding will be disabled.
■
Scrambler/descrambler will be disabled.
■
Autonegotiation will be disabled.
■
The signal detect inputs will be activated.
■
10Base-T will be disabled.
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Description (continued)
Functional Block Diagrams
Device Overview
FX_MODE_EN
MANAGEMENT
MII/SERIAL
INTERFACE
PMA
PCS
AUTONEGOTIATION
10 Mbits/s TRANSCEIVER
DRIVER AND FILTERS
MANAGEMENT
MII/SERIAL
INTERFACE
25 MHz
DPLL
10 Mbits/s TRANSCEIVER
DRIVER AND FILTERS
MUX
FX_MODE_EN
AUTONEGOTIATION
TX PMD/
FX PORT
DRIVER AND
FILTERS
10 Mbits/s TRANSCEIVER
DRIVER AND FILTERS
MUX
PMA
PCS
MANAGEMENT
PMA
PCS
25 MHz
LSCLK
FX_MODE_EN
AUTONEGOTIATION
MANAGEMENT
MII/SERIAL
INTERFACE
MUX
TX PMD/
FX PORT
DRIVER AND
FILTERS
PMA
PCS
MII/SERIAL
INTERFACE
TX PMD/
FX PORT
DRIVER AND
FILTERS
AUTONEGOTIATION
TP
MAGNETICS
INTERFACE
FX_MODE_EN
TX PMD/
FX PORT
DRIVER AND
FILTERS
125 MHz
10 Mbits/s TRANSCEIVER
DRIVER AND FILTERS
20 MHz
25 MHz
CRYSTAL
MUX
10 MHz
20 MHz
5-5137(F).fr2
Figure 1. LU3X54FTL Device Overview
Lucent Technologies Inc.
7
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
Description (continued)
Single-Channel Detail Functions
FX_MODE_EN
100 Mbits/s TRANSCEIVER
100 OFF
CRS
COL
RXD[3:0]
RX_DV
RX_ER/RXD[4]
RX_CLK
TX_CLK
TXD[3:0]
TX_EN
TX_ER/TXD[4]
4B/5B
ENCODER
TX STATE
MACHINE
MII
MDC
MDIO
FAR-END
FAULT GEN
SD
COLLISION
SD
DETECT
PMD
TX/
FIBER PORT
PDT
SCRAMBLER
RX STATE
MACHINE
SD
TPOUT±
DCRU
CAR_STAT
CIM
FX_MODE_EN
CARRIER
RXERR_ST DETECT
5B/4B
DECODER
ALIGNER
DESCRAMBLER
PMD
RX/
FIBER
PORT
PDR
FAR-END
FAULT DETECT
SD
REF10
RX_CLK
RXD[0]
TX_CLK
TX_EN
TXD[0]
CLK20
MANAGEMENT
INTERFACE
SERIAL
INTERFACE
MII
INTERFACE
TXD[3:0]
FOSD
TPIN±
10 Mbits/s TRANSCEIVER
LC100
LC10 LS10
MII
MANAGEMENT
LS100
AUTONEGOTIATION
AND LINK MONITOR
25 MHz
LSCLK
DPLL
25 MHZ
125 MHz
20 MHz
25 MHz
CRYSTAL
5-5136(F).j
Figure 2. LU3X54FTL Single-Channel Detail Functions
8
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Description (continued)
Application Diagrams
Single-Channel Twisted-Pair Interface
VDDO
RJ-45
LU3X54FTL
1:1
TPOUT+
1
50 Ω
220 Ω
50 Ω
TPOUT–
220 Ω
2
3
75 Ω
4
0.01 µF
0.01 µF
5
TPIN+
6
50 Ω
88
87
25 MHz
33 pF
50 Ω
TPIN–
8
75 Ω
1:1
XTALIN
XTALOUT
7
33 pF
75 Ω
0.01 µF
0.01 µF
0.01 µF
75 Ω
0.01 µF
5-5433(F).r9
Figure 3. Typical Single-Channel Twisted-Pair (TP) Interface
Lucent Technologies Inc.
9
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
Description (continued)
Single-Channel Fiber-Optic Interface
VDDA
0.01 µF
VDDO
LU3X54FTL
TPOUT+
TD
50 Ω
220 Ω
50 Ω
TPOUT–
220 Ω
82 Ω
82 Ω
82 Ω
0.01 µF
FOSD
SD
TPIN+
RD
33 pF
25 MHz
XTALIN
XTALOUT
TPIN–
87
50 Ω
TDN
0.01 µF
88
50 Ω
RDN
130 Ω
130 Ω
130 Ω
33 pF
5-5433(F).dr2
Figure 4. Typical Single-Channel Fiber-Optic Interface
10
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Description (continued)
Block Diagrams
Smart Bused MII Mode
RX_CLK10
RX_CLK10
RXD_10
RXD_10
TX_CLK10
TXD_10
10/100 Mbits/s
SMART
REPEATER
TX_CLK10
TXD_10
CRS_10/100
4
RX_EN10/100
TX_EN10/100
4
COL_10/100
4
4
SECURITY10/100
4
TX_CLK25
TXD_100[3:0]
TX_ER
RX_CLK25
RXD_100[3:0]
RX_DV
RX_ER
MDC
MDIO
CRS_100
RX_EN100
TX_EN100
COL_100
TX_EN10/SECURITY_10/100
TX_CLK25
LU3X54FTL
TXD_100[3:0]
TX_ER
RX_CLK25
RXD_100[3:0]
RX_DV
RX_ER
MDC
MDIO
SMART_MODE_SELECT
BUSED_MII_MODE
5-5599.gr1
Figure 5. Smart 10/100 Mbits/s Bused MII Mode
Lucent Technologies Inc.
11
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
Description (continued)
Separate Bused MII Mode
RX_CLK10
RX_CLK10
RXD_10
RXD_10
TX_CLK10
TXD_10
10 Mbits/s
REPEATER
COL_10
CRS_10
TX_CLK10
4
4
RX_EN10
TX_EN10
4
CRS_100
TX_EN100
4
4
4
TX_CLK25
TXD_100[3:0]
CRS_10
RX_EN10
TX_EN10
CRS_100
TX_EN100
LU3X54FTL
TXD_100[3:0]
TX_ER
RX_CLK25
RX_CLK25
RXD_100[3:0]
RXD_100[3:0]
RX_DV
RX_DV
RX_ER
COL_100
4
RX_EN100
4
MDC
MANAGEMENT
COL_10
TX_CLK25
TX_ER
100 Mbits/s
REPEATER
TXD_10
MDIO
RX_ER
COL_100
RX_EN100
MDC
MDIO
SMART_MODE_SELECT
BUSED_MII_MODE
5-5599.ar7
Figure 6. Separate 10/100 Mbits/s Bused MII Mode
12
Lucent Technologies Inc.
MASK_STAT_INT
NC
MODE[4]
TXD[0][C]
TXD[1][C]
VSS
TXD[2][C]
TXD[3][C]
VDD3
TX_ER[C]/TXD[4][C]
TX_EN[C]
VSS
TX_CLK[C]
CRS[C]
COL[C]
RX_DV[C]
VDD3
RX_ER[C]/RXD[4][C]
RX_CLK[C]
RXD[0][C]
VSS
RXD[1][C]
RXD[2][C]
RXD[3][C]
VDD
MII_EN[C]
VSS
VDDPLL
CKREF
VSSPLL
VDDPD
FOSD[A]
FOSD[B]
VSSPD
LSCLK/XTALIN
XTALOUT
TXD[0][D]
TXD[1][D]
VSS
TXD[2][D]
TXD[3][D]
VDD
TX_ER[D]TXD[4][D]
TX_EN[D]
VSS
TX_CLK[D]
CRS[D]
COL[D]
RX_DV[D]
VDD3
RX_ER[D]/RXD[4][D]
RX_CLK[D]
GNDA
FOSD[C]
FOSD[D]
VDDA
TPIN+/FOIN+[D]
TPIN–/FOIN–[D]
GNDA
VDDA
TPIN+/FOIN+[C]
TPIN–/FOIN–[C]
GNDA
VDDA
BGREF[0]
GNDA
VDDA
TPIN+/FOIN+[B]
TPIN–/FOIN–[B]
GNDA
VDDA
TPIN+/FOIN+[A]
TPIN–/FOIN–[A]
GNDA
VDDA
GNDA
BGREF[1]
GNDD
CLK20
VDDD
GNDAA
VDDAA
GNDO
TPOUT+/FOOUT+[D]
TPOUT–/FOOUT–[D]
VDDO
GNDO
TPOUT+/FOOUT+[C]
TPOUT–/FOOUT–[C]
VDDO
GNDM
VDDM
GNDAP
ISET_10
ISET_100
VDDAP
GNDO
TPOUT+/FOOUT+[B]
TPOUT–/FOOUT–[B]
VDDO
GNDO
TPOUT+/FOOUT+[A]
TPOUT–/FOOUT–[A]
VDDO
208
207
206
205
204
203
202
201
200
199
198
197
196
195
194
193
192
191
190
189
188
187
186
185
184
183
182
181
180
179
178
177
176
175
174
173
172
171
170
169
168
167
166
165
164
163
162
161
160
159
158
157
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
VSS
MODE[3]
MODE[2]
MODE[1]
MODE[0]
RESET
VDD
H_DUPLED[D]/FULL_DUP
H_DUPLED[C]/SERIAL_SEL
H_DUPLED[B]/CRS_SEL
H_DUPLED[A]/CLK20_SEL
AUTO_EN
3ST_EN
VDD
SPEEDLED[D]/SPEED
SPEEDLED[C]/SMART_MODE_SELECT
SPEEDLED[B]/BUSED_MII_MODE
SPEEDLED[A]/ISOLATE_MODE
LINKLED[D]/PHYADD[2]
LINKLED[C]PHYADD[1]
LINKLED[B]/PHYADD[0]
LINKLED[A]/NO_LP
VSS
VDDA
ATEST[B]
ATEST[A]
GNDA
GNDC
VDDC
VDDC
GNDC
VSS
COLED[D]
COLED[C]
COLED[B]
COLED[A]
VDD
RXLED[D]/FX_MODE_EN[D]
RXLED[C]/FX_MODE_EN[C]
RXLED[B]/FX_MODE_EN[B]
RXLED[A]/FX_MODE_EN[A]
VDD
TXLED[D]/CARIN_EN
TXLED[C]/ENC_DEC_BYPASS
TXLED[B]/SCRAM_DESC_BYPASS
VSS
TXLED[A]/REF_SEL
MII_EN[B]
VDD3
RXD[3][B]
RXD[2][B]
RXD[1][B]
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Pin Information
Pin Diagram for Normal MII Mode
Lucent Technologies Inc.
LU3X54FTL
156
155
154
153
152
151
150
149
148
147
146
145
144
143
142
141
140
139
138
137
136
135
134
133
132
131
130
129
128
127
126
125
124
123
122
121
120
119
118
117
116
115
114
113
112
111
110
109
108
107
106
105
VSS
RXD[0][B]
RX_CLK[B]
RX_ER[B]/RXD[4][B]
VDD3
RX_DV[B]
COL[B]
CRS[B]
TX_CLK[B]
VSS
TX_EN[B]
TX_ER[B]/TXD[4][B]
VDD
TXD[3][B]
TXD[2][B]
VSS
TXD[1][B]
TXD[0][B]
MII_EN[A]
VDD3
RXD[3][A]
RXD[2][A]
RXD[1][A]
VSS
RXD[0][A]
RX_CLK[A]
RX_ER[A]/RXD[4][A]
VDD3
RX_DV[A]
COL[A]
CRS[A]
TX_CLK[A]
VSS
TX_EN[A]
TX_ER[A]/TXD[4][A]
VDD3
TXD[3][A]
TXD[2][A]
VSS
TXD[1][A]
TXD[0][A]
VSS
REF10
MDC
MDIO
VDD
MII_EN[D]
RXD[3][D]
RXD[2][D]
RXD[1][D]
VSS
RXD[0][D]
5-5616(F).cr3
Figure 7. LU3X54FTL Pinout for Normal MII Mode
13
MASK_STAT_INT
NC
MODE[4]
RX_EN10[A]
RX_EN10[B]
VSS
RX_EN10[C]
RX_EN10[D]
VDD3
NC
TX_EN100[C]/TX_EN10/100
VSS
NC
CRS_100[C]/CRS_10/100[C]
COL_100[C]/COL_10/100[C]
NC
VDD3
NC
NC
COL_10[A]
VSS
COL_10[B]
COL_10[C]
COL_10[D]
VDD
RX_EN100[C]/RX_EN10/100[C]
VSS
VDDPLL
CKREF
VSSPLL
VDDPD
FOSD[A]
FOSD[B]
VSSPD
LSCLK/XTALIN
XTALOUT
TX_EN10[A]/SECURITY_10/100
TX_EN10[B]/SECURITY_10/100
VSS
TX_EN10[C]/SECURITY_10/100
TX_EN10[D]/SECURITY_10/100
VDD
NC
TX_EN100[D]/TX_EN10/100
VSS
NC
CRS_100[D]/CRS_10/100[D]
COL_100[D]/COL_10/100[D]
NC
VDD3
NC
NC
GNDA
FOSD[C]
FOSD[D]
VDDA
TPIN+/FOIN+[D]
TPIN–/FOIN–[D]
GNDA
VDDA
TPIN+/FOIN+[C]
TPIN–/FOIN–[C]
GNDA
VDDA
BGREF[0]
GNDA
VDDA
TPIN+/FOIN+[B]
TPIN–/FOIN–[B]
GNDA
VDDA
TPIN+/FOIN+[A]
TPIN–/FOIN–[A]
GNDA
VDDA
GNDA
BGREF[1]
GNDD
CLK20
VDDD
GNDAA
VDDAA
GNDO
TPOUT+/FOOUT+[D]
TPOUT–/FOOUT–[D]
VDDO
GNDO
TPOUT+/FOOUT+[C]
TPOUT–/FOOUT–[C]
VDDO
GNDM
VDDM
GNDAP
ISET_10
ISET_100
VDDAP
GNDO
TPOUT+/FOOUT+[B]
TPOUT–/FOOUT–[B]
VDDO
GNDO
TPOUT+/FOOUT+[A]
TPOUT–/FOOUT–[A]
VDDO
14
208
207
206
205
204
203
202
201
200
199
198
197
196
195
194
193
192
191
190
189
188
187
186
185
184
183
182
181
180
179
178
177
176
175
174
173
172
171
170
169
168
167
166
165
164
163
162
161
160
159
158
157
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
VSS
MODE[3]
MODE[2]
MODE[1]
MODE[0]
RESET
VDD
H_DUPLED[D]/FULL_DUP
H_DUPLED[C]/SERIAL_SEL
H_DUPLED[B]/CRS_SEL
H_DUPLED[A]/CLK20_SEL
AUTO_EN
3ST_EN
VDD
SPEEDLED[D]/SPEED
SPEEDLED[C]/SMART_MODE_SELECT
SPEEDLED[B]/BUSED_MII_MODE
SPEEDLED[A]/ISOLATE_MODE
LINKLED[D]/PHYADD[2]
LINKLED[C]PHYADD[1]
LINKLED[B]/PHYADD[0]
LINKLED[A]/NO_LP
VSS
VDDA
ATEST[B]
ATEST[A]
GNDA
GNDC
VDDC
VDDC
GNDC
VSS
COLED[D]
COLED[C]
COLED[B]
COLED[A]
VDD
RXLED[D]/FX_MODE_EN[D]
RXLED[C]/FX_MODE_EN[C]
RXLED[B]/FX_MODE_EN[B]
RXLED[A]/FX_MODE_EN[A]
VDD
TXLED[D]/CARIN_EN
TXLED[C]/ENC_DEC_BYPASS
TXLED[B]/SCRAM_DESC_BYPASS
VSS
TXLED[A]/REF_SEL
RX_EN100[B]/RX_EN10/100[B]
VDD3
NC
NC
NC
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
LU3X54FTL
Data Sheet
July 2000
Pin Information (continued)
Pin Diagram for Bused MII Mode
156
155
154
153
152
151
150
149
148
147
146
145
144
143
142
141
140
139
138
137
136
135
134
133
132
131
130
129
128
127
126
125
124
123
122
121
120
119
118
117
116
115
114
113
112
111
110
109
108
107
106
105
VSS
RXD_10
RX_CLK10
NC
VDD3
NC
COL_100[B]/COL_10/100[B]
CRS_100[B]/CRS_10/100[B]
TX_CLK10
VSS
TX_EN100[B]/TX_EN10/100
NC
VDD
NC
NC
VSS
NC
TXD_10
RX_EN100[A]/RX_EN10/100[A]
VDD3
RXD_100[3]
RXD_100[2]
RXD_100[1]
VSS
RXD_100[0]
RX_CLK25
RX_ER
VDD3
RX_DV
COL_100[A]/COL_10/100[A]
CRS_100[A]/CRS_10/100[A]
TX_CLK25
VSS
TX_EN100[A]/TX_EN10/100
TX_ER
VDD3
TXD_100[3]
TXD_100[2]
VSS
TXD_100[1]
TXD_100[0]
VSS
REF10
MDC
MDIO
VDD
RX_EN100[D]/RX_EN10/100[D]
CRS_10[D]
CRS_10[C]
CRS_10[B]
VSS
CRS_10[A]
5-5616(F).dr2
Figure 8. LU3X54FTL Pinout for Bused MII Mode
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Pin Information (continued)
Pin Maps
Table 2. LU3X54FTL Pin Maps
Normal Mode Pins
Bused Mode Pins
10/100 Mbits/s Smart Mode Pins
Separate Mode Pins
RXD[3:0][D]
CRS_10[D:A]
Not used
CRS_10
CRS[D:A]
CRS_100[D:A]
CRS_10/100
CRS_100
TXD[3:0][C]
RX_EN10/100
Not used
RX_EN10
MII_EN[D:A]
RX_EN100[D:A]
RX_EN10/100
RX_EN100
TXD[3:0][D]
TX_EN10[D:A]
SECURITY_10/100
TX_EN10
TX_EN[D:A]
TX_EN100[D:A]
TX_EN10/100
TX_EN100
RXD[3:0][C]
COL_10[D:A]
Not used
COL_10
COL[D:A]
COL_100[D:A]
COL_10/100
COL_100
SPEEDLED[C]
SMART_MODE_SELECT
SMART_MODE_SELECT
SMART_MODE_SELECT
SPEEDLED[B]
BUSED_MII_MODE
BUSED_MII_MODE
BUSED_MII_MODE
TX_CLK[A]
TX_CLK25
TX_CLK25
TX_CLK25
TX_CLK[B]
TX_CLK10
TX_CLK10
TX_CLK10
RX_CLK[B]
RX_CLK10
RX_CLK10
RX_CLK10
RX_CLK[A]
RX_CLK25
RX_CLK25
RX_CLK25
RXD[0][B]
RXD_10
RXD_10
RXD_10
RXD[3:0][A]
RXD_100[3:0]
RXD_100
RXD_100
RX_DV[A]
RX_DV
RX_DV
RX_DV
RX_ER[A]
RX_ER
RX_ER
RX_ER
TXD[0][B]
TXD_10
TXD_10
TXD_10
TXD[3:0][A]
TXD_100[3:0]
TXD_100
TXD_100
TX_ER[A]/TXD[4][A]
TX_ER
TX_ER
TX_ER
Lucent Technologies Inc.
15
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
Pin Information (continued)
Pin Descriptions
This section describes the LU3X54FTL signal pins. Note that any register bit referenced includes the register number and bit position. For example, register bit [29.8] is register 29, bit 8.
Table 3. MII/Serial Interface Pins in Normal MII Mode (Four Separate MII Ports)
16
Pin
Signal
Type
Description
100
67
150
127
COL[D:A]
O
99
66
149
126
CRS[D:A]
O
104
71
154
131
109
76
159
136
108
75
158
135
107
74
157
134
105
72
155
132
101
68
151
128
103
70
153
130
RX_CLK[D:A]
O
RXD[3:0][D:A]
O
Collision Detect. This signal signifies in half-duplex mode that a collision
has occurred on the network. COL is asserted high whenever there is
transmit and receive activity on the UTP media. COL is the logical AND of
TX_EN and receive activity, and is an asynchronous output. When
SERIAL_SEL is high and in 10Base-T mode, this signal indicates the jabber timer has expired.
Carrier Sense. When CRS_SEL is low, this signal is asserted high when
either the transmit or receive medium is nonidle. This signal remains
asserted throughout a collision condition. When CRS_SEL is high, CRS is
asserted on receive activity only. CRS_SEL is set via the MII management
interface or the CRS_SEL pin.
Receive Clock. 25 MHz clock output in 100 Mbits/s mode, 2.5 MHz output
in 10 Mbits/s nibble mode, 10 MHz in 10 Mbits/s serial mode. RX_CLK has
a worst-case 45/55 duty cycle. RX_CLK provides the timing reference for
the transfer of RX_DV, RXD, and RX_ER signals.
Receive Data. 4-bit parallel data outputs that are synchronous to RX_CLK.
When RX_ER[D:A] is asserted high in 100 Mbits/s mode, an error code will
be presented on RXD[3:0][D:A] where appropriate. The codes are as follows:
■
Packet errors: ERROR_CODES = 2h.
■
Link errors: ERROR_CODES = 3h. (Packet and link error codes will only
be repeated if registers [29.9] and [29.8] are enabled.)
■
Premature end errors: ERROR_CODES = 4h.
■
Code errors: ERROR_CODES = 5h.
When SERIAL_SEL is active-high and 10 Mbits/s mode is selected, RXD[0]
is used for data output and RXD[3:1] are 3-stated.
RX_DV[D:A]
O
RX_ER[D:A]/
RXD[4][D:A]
O
Receive Data Valid. When this pin is high, it indicates the LU3X54FTL is
recovering and decoding valid nibbles on RXD[3:0], and the data is synchronous with RX_CLK. RX_DV is synchronous with RX_CLK. This pin is
not used in serial 10 Mbits/s mode.
Receive Error. When high, RX_ER indicates the LU3X54FTL has detected
a coding error in the frame presently being transferred. RX_ER is synchronous with RX_CLK.
Receive Data[4]. When encoder/decoder bypass (ENC_DEC_BYPASS) is
selected through the MII management interface, this output serves as the
RXD[4] output. This pin is only valid when the LU3X54FTL is in 100 Mbits/s
mode.
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Pin Information (continued)
Table 3. MII/Serial Interface Pins in Normal MII Mode (Four Separate MII Ports) (continued)
Pin
Signal
Type
Description
98
65
148
125
93, 60
143, 120
92, 59
142, 119
90, 57
140, 117
89, 56
139, 116
96
63
146
123
95
62
145
122
TX_CLK[D:A]
O
TXD[3:0][D:A]
I
Transmit Clock. 25 MHz clock output in 100 Mbits/s mode, 2.5 MHz output
in 10 Mbits/s MII mode, 10 MHz output in 10 Mbits/s serial mode. TX_CLK
provides timing reference for the transfer of the TX_EN, TXD, and TX_ER
signals sampled on the rising edge of TX_CLK.
Transmit Data. 4-bit parallel input synchronous with TX_CLK. When
SERIAL_SEL is active-high and 10 Mbits/s mode is selected, only
TXD[0][D:A] are valid.
TX_EN[D:A]
I
TX_ER[D:A]/
TXD[4][D:A]
I
MII_EN[D:A]
I
110
78
161
138
Lucent Technologies Inc.
Transmit Enable. When driven high, this signal indicates there is valid data
on TXD[3:0]. TX_EN is synchronous with TX_CLK. When SERIAL_SEL is
active-high and 10 Mbits/s mode is selected, this pin indicates there is valid
data on TXD[0].
Transmit Coding Error. When driven high, this signal causes the encoder
to intentionally corrupt the byte being transmitted across the MII (00100 will
be transmitted).
Transmit Data[4]. When the encoder/decoder bypass bit is set, this input
serves as the TXD[4] input. When in 10 Mbits/s mode and SERIAL_SEL is
active-high, this pin is ignored.
MII Enable. For normal MII mode of operation (nonbused mode), MII_EN
for each channel must be tied high to enable each individual port being
used.
17
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
Pin Information (continued)
When operating in bused MII mode, 100 Mbits/s data is bused to MII port A, and 10 Mbits/s data is bused to MII
port B.
Table 4. MII/Serial Interface Pins in Bused MII Mode
Pin
Signal
Type
Description
125
TX_CLK25
O
148
TX_CLK10
O
Shared Transmit Clock (25 MHz). 25 MHz clock output in 100 Mbits/s mode.
TX_CLK25 provides timing reference for the transfer of the TX_EN100,
TXD_100, and TX_ER signals that are sampled on the rising edge of
TX_CLK25.
Shared Transmit Clock (10 MHz). 10 MHz clock output in 10 Mbits/s serial
mode. TX_CLK10 provides timing reference for the transfer of the TX_EN10
and TXD_10 signals that are sampled on the rising edge of TX_CLK10.
109
108
107
105
CRS_10[D:A]
O
99
66
149
126
CRS_100[D:A]/
CRS_10/100[D:A]
O
154
RX_CLK10
O
131
RX_CLK25
O
155
RXD_10
O
18
When operating in 10 Mbits/s bused mode, the REF10 input clock must be
used, and the REF_SEL pin must be pulled high through a 4.7 kΩ resistor
(TXLED[A] pin).
Carrier Sense—10 Mbits/s Mode. When CRS_SEL is low, this signal is
asserted high when either the transmit or receive medium is nonidle. This signal remains asserted throughout a collision condition. When CRS_SEL is
high, CRS_10 is asserted on receive activity only. CRS_SEL is set via the MII
management interface or the CRS_SEL pin.
When SMART_MODE_SELECT is asserted, the LU3X54FTL will internally
OR together the CRS_10 and the CRS_100 signals and output them on the
CRS_100 signals.
Carrier Sense—100 Mbits/s Mode. When CRS_SEL is low, this signal is
asserted high when either the transmit or receive medium is nonidle. This signal remains asserted throughout a collision condition. When CRS_SEL is
high, CRS_100 is asserted on receive activity only. CRS_SEL is set via the MII
management interface or the CRS_SEL pin.
Carrier Sense—10/100 Mbits/s Smart Mode. When
SMART_MODE_SELECT is asserted, the LU3X54FTL will internally OR
together the CRS_10 and the CRS_100 signals and output them on the
CRS_100 signals.
Shared Receive Clock. 10 MHz clock output in 10 Mbits/s serial mode.
RX_CLK10 has a worst-case 45/55 duty cycle. RX_CLK10 provides the timing
reference for the transfer of RXD_10 when in the 10 Mbits/s mode. This signal
is sampled on the rising edge of RX_CLK10.
Shared Receive Clock. 25 MHz clock output in the 100 Mbits/s mode.
RX_CLK25 has a worst-case 45/55 duty cycle. RX_CLK25 provides the timing
reference for the transfer of RX_DV, RXD_100, and RX_ER signals when in
the 100 Mbits/s mode. These signals are sampled on the rising edge of
RX_CLK100.
Shared Receive Data. Serial data output that is synchronous to the falling
edge of RX_CLK10.
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Pin Information (continued)
When operating in bused MII mode, 100 Mbits/s data is bused to MII port A, and 10 Mbits/s data is bused to MII
port B.
Table 4. MII/Serial Interface Pins in Bused MII Mode (continued)
Pin
Signal
Type
Description
136
135
134
132
RXD_100[3:0]
O
Shared Receive Data. 4-bit parallel data outputs that are synchronous to the
falling edge of RX_CLK25. When RX_ER is asserted high, an error code will
be presented on RXD_100[3:0] where appropriate. The codes are as follows:
60
59
57
56
RX_EN10[D:A]
I
■
Packet errors, ERROR_CODES = 2h.
■
Link errors, ERROR_CODES = 3h (packet and link error codes will only be
repeated if registers [29.9] and [29.8] are enabled).
■
Premature end errors, ERROR_CODES = 4h.
■ Code errors, ERROR_CODES = 5h.
Receive Enable—10 Mbits/s Mode. When SMART_MODE_SELECT is not
enabled and RX_EN10 is driven high, its channel’s data and clock (RXD0 and
RX_CLK) are driven onto the shared serial bus. If the individual channel is not
configured for 10 Mbits/s mode, this input will be ignored. When RX_EN10s
are all set low, the serial bus will float.
Note: Care should be taken that no more than one RX_EN is asserted at a
time.
110
78
161
138
RX_EN100[D:A]/
RX_EN10/100[D:A]
I
128
RX_DV
O
130
RX_ER
O
139
120
119
117
116
TXD_10
TXD_100[3:0]
I
I
Lucent Technologies Inc.
When SMART_MODE_SELECT is enabled, these pins are ignored.
Receive Enable—100 Mbits/s Mode. When SMART_MODE_SELECT is not
enabled and RX_EN100 is driven high, its channel’s data, clock, and receive
data valid signals (RXD_100, RX_DV, RX_ER, and RX_CLK25) are driven
onto the shared MII bus. If the individual channel is not configured for
100 Mbits/s mode, this input will be ignored. When RX_EN100s are all set low,
the MII bus will float.
Note: Care should be taken that no more than one RX_EN is asserted at a
time.
Receive Enable—10/100 Mbits/s Smart Mode. When
SMART_MODE_SELECT is asserted and RX_EN100 is driven high, its channel’s data, clock, and receive data valid signals [RXD, RX_ER (100 Mbits/s
only), RX_DV (100 Mbits/s only), and RX_CLK] are driven onto the shared bus
corresponding to the speed of the channel.
Shared Receive Data Valid. When this pin is driven high, it indicates that the
LU3X54FTL is recovering and decoding valid nibbles on RXD[3:0] and that the
data is synchronous with RX_CLK. RX_DV is synchronous with RX_CLK. This
pin is not used in serial 10 Mbits/s mode.
Shared Receive Error. When asserted high, it indicates that the LU3X54FTL
has detected a coding error in the frame presently being transferred. RX_ER is
synchronous with RX_CLK25. This signal is not used in 10 Mbits/s mode.
Shared Transmit Data. 10 Mbits/s serial input synchronous with TX_CLK10.
Shared Transmit Data. 4-bit parallel input synchronous with TX_CLK25.
19
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
Pin Information (continued)
When operating in bused MII mode, 100 Mbits/s data is bused to MII port A, and 10 Mbits/s data is bused to MII
port B.
Table 4. MII/Serial Interface Pins in Bused MII Mode (continued)
Pin
Signal
Type
Description
93
92
90
89
TX_EN10/[D:A]/
SECURITY_10/100
I
Transmit Enable—10 Mbits/s Mode. When driven high, this signal indicates
that there is valid data on TXD when the corresponding channel is in
10 Mbits/s serial mode.
Security for 10/100 Mbits/s Smart Mode. When SMART_MODE_SELECT
is enabled, these pins are redefined to be the security input pins for both
10 Mbits/s and 100 Mbits/s. When security is activated, the LU3X54FTL will
ignore the transmit data, and a fixed pattern is transmitted (all 1s for 10Base-T,
alternating 1, 0 for 100TX).
96
63
146
123
TX_EN100[D:A]/
TX_EN10/100
I
122
TX_ER
I
76
75
74
72
COL_10[D:A]
O
100
67
150
127
20
COL_100[D:A]/
COL_10/100[D:A]
O
Security should not be asserted until after the entire preamble has been transmitted. When in smart mode, the 10 Mbits/s transmit channels will be enabled
through the TX_EN100 inputs.
Transmit Enable—100 Mbits/s Mode. When SMART_MODE_SELECT is not
enabled and TX_EN100 is driven high, this signal indicates that there is valid
data on TXD_100[3:0] when in 100 Mbits/s mode. If the individual channel is
not configured for 100 Mbits/s mode, this input will be ignored.
Transmit Enable—10/100 Mbits/s Smart Mode. When
SMART_MODE_SELECT is asserted and TX_EN100 is driven high, this signal indicates that its channel’s input data is valid. The input data is selected by
the speed of the corresponding channel.
Shared Transmit Coding Error. When asserted high, this signal causes the
encoder to intentionally corrupt the byte being transmitted across the MII
(00100 will be transmitted). This signal is not used in 10 Mbits/s mode.
Collision Detect for 10 Mbits/s Mode. In half-duplex mode, this signal signifies that a collision has occurred on the network. COL_10 is asserted high
whenever there is transmit and receive activity on the UTP media. COL_10 is
the logical AND of TX_EN and receive activity, and it is an asynchronous output.
When SERIAL_SEL is high and in 10Base-T mode, this signal indicates that
the jabber timer has expired. When SMART_MODE_SELECT is asserted, the
LU3X54FTL will internally OR together the COL_10 and COL_100 signals and
output them on the COL_100 pins.
Collision Detect for 100 Mbits/s Mode. In half-duplex mode, this signal signifies that a collision has occurred on the network. COL_100 is asserted high
whenever there is transmit and receive activity on the UTP media. COL_100 is
the logical AND of TX_EN and receive activity, and it is an asynchronous output.
Collision Detect for 10/100 Mbits/s Smart Mode. When SERIAL_SEL is
high and in 10Base-T mode, this signal indicates that the jabber timer has
expired. When SMART_MODE_SELECT is asserted, the LU3X54FTL will
internally OR together the COL_10 and COL_100 signals and output them on
the COL_100 pins.
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Pin Information (continued)
When operating in bused MII mode, 100 Mbits/s data is bused to MII port A, and 10 Mbits/s data is bused to MII
port B.
Table 4. MII/Serial Interface Pins in Bused MII Mode (continued)
Pin
Signal
Type
65
68
70
71
98
101
103
104
62
95
140
142
143
145
151
153
157
158
159
NC
O
No Connect. Do not connect these pins.
NC
I
No Connect. These inputs should be grounded.
Lucent Technologies Inc.
Description
21
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
Pin Information (continued)
Table 5. MII Management Pins
Pin
Signal
Type
Description
113
MDC
I
Management Data Clock. This is the timing reference for the transfer of
data on the MDIO signal. This signal may be asynchronous to RX_CLK and
TX_CLK. The maximum clock rate is 12.5 MHz.
112
MDIO
I/O
53
MASK_STAT_INT
O
When running MDC above 6.25 MHz, MDC must be synchronous with
LSCLK and have a setup time of 15 ns and a hold time of 5 ns with respect
to LSCLK. When using an external crystal instead of an LSCLK input, the
maximum MDC rate is 6.25 MHz.
Management Data Input/Output. This I/O is used to transfer control and
status information between the LU3X54FTL and the station management.
Control information is driven by the station management synchronous with
MDC. Status information is driven by the LU3X54FTL synchronous with
MDC. This pin requires an external 1.5 kΩ pull-up resistor.
Maskable Status Interrupt. This pin will go high whenever there is a
change in status as defined in Table 22.
Table 6. 10/100 Mbits/s Twisted-Pair (TP) Interface Pins
Pin
Signal
Type
Description
5
9
16
20
TPIN+/
FOIN+[D:A]
I
Received Data. Positive differential received 125 Mbaud MLT3, or 10 Mbaud
Manchester data from magnetics.
6
10
17
21
TPIN–/
FOIN–[D:A]
32
36
46
50
TPOUT+/
FOOUT+[D:A]
33
37
47
51
TPOUT–/
FOOUT–[D:A]
3
2
85
84
FOSD[D:A]
22
Fiber-Optic Data Input. Positive differential received 125 Mbaud pseudoECL data from fiber transceiver.
I
Received Data. Negative differential received 125 Mbaud MLT3 or 10 Mbaud
Manchester data from magnetics.
Fiber-Optic Data Input. Negative differential received 125 Mbaud pseudoECL data from fiber transceiver.
O
Transmit Data. Positive differential transmit 125 Mbaud MLT3 or 10 Mbaud
Manchester data to magnetics.
Fiber-Optic Data Output. Positive differential transmit 125 Mbaud pseudoECL compatible data to fiber transceiver.
O
Transmit Data. Negative differential transmit 125 Mbaud MLT3 or 10 Mbaud
Manchester data to magnetics.
Fiber-Optic Data Output. Negative differential transmit 125 Mbaud pseudoECL compatible data to fiber transceiver.
I
Fiber-Optic Signal Detect. Pseudo-ECL input signal which indicates
whether or not the fiber-optic receive pairs (FOIN±) are receiving valid signal
levels. These inputs are ignored when not in fiber mode, and should be
grounded.
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Pin Information (continued)
Table 7. Miscellaneous Pins
Pin
Signal
Type
81
CKREF
I
184
183
197
ATEST[B:A]
O
AUTO_EN
I
1, 7,
11, 14,
18, 22,
24, 26,
29, 31,
35, 39,
41, 45,
49, 58,
64, 73,
79, 82,
86, 91,
97, 106,
115, 118,
124, 133,
141, 147,
156, 163,
177, 178,
181, 182,
186, 208
4, 8, 12,
15, 19,
23, 28,
30, 34,
38, 40,
44, 48,
52, 77,
80, 83,
94, 111,
144, 167,
172, 179,
180, 185,
195, 202
61, 69,
102, 121,
129, 137,
152, 160
196
GND/VSS
3ST_EN
I
25
13
42
BGREF[1:0]
I
ISET_10
I
Description
Clock Reference. Connect this pin to a 1 nF ± 10% capacitor to
ground.
Reserved. For normal operation, leave these pins unconnected.
Autonegotiation Enable. When this pin is high, autonegotiation is
enabled. Pulsing this pin will cause autonegotiation to restart. This
input has the same function as register 0, bit 12. This input and the register bit are ANDed together.
PWR Ground. (38 pins.)
VDD
PWR VDD. 5.0 V ± 5% power supply (27 pins.)
VDD3
PWR VDD3. 3.3 V ± 5% or 5.0 V ± 5% power supply (8 pins.)
Lucent Technologies Inc.
3-State Enable. When this pin is high, all digital outputs will be
3-stated. For normal operating conditions, pull this pin low.
Band Gap Reference. Connect these pins to a 24.9 kΩ ± 1% resistor
to ground. The parasitic load capacitance should be less than 15 pF.
Current Set 10 Mbits/s. An external resistor (22.1 kΩ) is placed from
this pin to ground to set the 10 Mbits/s TP driver transmit output level.
23
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
Pin Information (continued)
Table 7. Miscellaneous Pins (continued)
Pin
Signal
Type
Description
43
ISET_100
I
114
REF10
I
27
CLK20
I
166
TXLED[D]/
CARIN_EN
I/O
Current Set 100 Mbits/s. An external resistor (nominally 24.9 kΩ) is
placed from this pin to ground to set the 100 Mbits/s TP driver transmit
output level.
10 MHz Input Clock. Optional reference clock for 10 Mbits/s repeater
mode for phase alignment. When used, TX_CLK will be driven from
REF10. If not used, let this pin float.
20 MHz Input Clock. 20 MHz (±100 ppm) TTL level clock with
45%—55% duty cycle. If the internal 20 MHz clock synthesizer is being
used, ground this pin (default).
Transmit LED[D]. This pin indicates transmit activity on port D. External buffers are necessary to drive the LEDs.
Carrier Integrity Enable. At powerup or reset, if this pin is pulled high
through a 4.7 kΩ resistor, it will enable the carrier integrity function of
register 29, bit 3, if station management is unavailable.
165
164
162
TXLED[C]/
ENC_DEC_BYPASS
TXLED[B]/
SCRAM_DESC_BYPASS
TXLED[A]/
REF_SEL
I/O
I/O
I/O
This pin has an internal 50 kΩ pull-down resistor for normal operation
(CARIN_EN is disabled). This input and register bits [29.3] are ORed
together.
Transmit LED[C]. This pin indicates transmit activity on port C. External buffers are necessary to drive the LEDs.
Encoder/Decoder Bypass. At powerup or reset, if this pin is pulled
high through a 4.7 kΩ resistor, it will enable the ENC_DEC_BYPASS
function of register 29, bit 6, if station management is unavailable.
This pin has an internal 50 kΩ pull-down resistor for normal operation
(encoder/decoder ON). This input and the register bit [29.6] are ORed
together enabling the encoder/decoder bypass function for all four
channels.
Transmit LED[B]. This pin indicates transmit activity on port B. External buffers are necessary to drive the LEDs.
Scrambler/Descrambler Bypass. At powerup or reset, this pin may
be used to enable the SCRAM_DESC_BYPASS function by pulling this
pin high through a 4.7 kΩ resistor, if station management is unavailable. This is the same function as register 29, bit 4.
This pin has an internal 50 kΩ pull-down resistor for normal operation
(scrambler/descrambler ON). This input and the register bit [29.4] are
ORed together during powerup and reset.
Transmit LED[A]. This pin indicates transmit activity on port A. External buffers are necessary to drive the LEDs.
Reference Select. At powerup, this pin may be used to select the
10 MHz reference input of pin REF10 by pulling it high through a 4.7 kΩ
resistor, if station management is unavailable. This is the same function
as register 30, bit 2.
This pin has an internal 50 kΩ pull-down resistor for normal operation
(REF10 not used). This input and the register bit are ORed together.
24
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Pin Information (continued)
Table 7. Miscellaneous Pins (continued)
Pin
Signal
Type
Description
171—168
RXLED[D:A]/
FX_MODE_EN[D:A]
I/O
Receive LED[D:A]. This pin indicates receive activity. External buffers
are necessary to drive the LEDs.
FX Mode Enable. At powerup or reset, when pulled high through a
4.7 kΩ resistor, this pin will enable the FX mode (10Base-T and
100Base-TX disabled). When pulled low, it will enable 10Base-T and
100Base_TX modes (100Base-FX mode disabled). These pins are
ORed with register 29, bit 0 [29.0].
176—173
COLED[D:A]
O
These pins have internal 50 kΩ pull-down resistors.
Collision LED. This pin indicates collision occurrence. External buffers
are necessary to drive the LEDs.
I/O
Channels A and B have internal 50 kΩ pull-down resistors but not
channels C and D.
Link LED[D]. This pin indicates good link status on port D. External
buffers are necessary to drive the LEDs.
PHY Address 2. At powerup or reset, this pin is used to set the PHY
address bit 2.
I/O
If this pin is pulled high through a 50 kΩ resistor, it will set PHYADD[2]
to a 1. If this pin is pulled low through a 50 kΩ resistor, it will set
PHYADD[2] to a 0.
Link LED[C]. This pin indicates good link status on port C. External
buffers are necessary to drive the LEDs.
PHY Address 1. At powerup or reset, this pin is used to set the PHY
address bit 1.
I/O
If this pin is pulled high through a 50 kΩ resistor, it will set PHYADD[1]
to a 1. If this pin is pulled low through a 50 kΩ resistor, it will set
PHYADD[1] to a 0.
Link LED[B]. This pin indicates good link status on port B. External
buffers are necessary to drive the LEDs.
PHY Address 0. At powerup or reset, this pin may be used to set the
PHY address bit 0.
190
189
188
187
LINKLED[D]/
PHYADD[2]
LINKLED[C]/
PHYADD[1]
LINKLED[B]/
PHYADD[0]
LINKLED[A]/
NO_LP
I/O
If this pin is pulled high through a 50 kΩ resistor, it will set PHYADD[0]
to a 1. If this pin is pulled low through a 50 kΩ resistor, it will set
PHYADD[0] to a 0.
Link LED[A]. This pin indicates good link status on port A. External
buffers are necessary to drive the LEDs.
No Link Pulse. This pin is used at powerup or reset to select the
NO_LP function of register 30, bit 0 for all four channels by pulling this
pin high through a 4.7 kΩ resistor. This input and the register bit [30.0]
are ORed together.
This pin has an internal 50 kΩ pull-down resistor to set the default to
normal link pulse ON mode.
Lucent Technologies Inc.
25
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
Pin Information (continued)
Table 7. Miscellaneous Pins (continued)
Pin
Signal
Type
Description
194
SPEEDLED[D]/
SPEED
I/O
Speed LED[D]. This pin indicates the operating speed of port D on the
LU3X54FTL. A high on this pin indicates 100 Mbits/s operation. A low
indicates 10 Mbits/s operation. External buffers are necessary to drive
the LEDs.
Speed. This pin is used at powerup or reset to select the operating
speed on all four channels and is the same function as register 0,
bit 13:
193
SPEEDLED[C]/
SMART_MODE_SELECT
I/O
■
This pin is internally pulled high through a 100 kΩ resistor to enable
100 Mbits/s operation (defaults to 100 Mbits/s).
■
If this pin is pulled low through a 4.7 kΩ resistor, it will enable
10 Mbits/s operation.
This pin is ignored when autonegotiation is enabled. This pin and the
register bit are ANDed.
Speed LED[C]. This pin indicates the operating speed of port C on the
LU3X54FTL. A high on this pin indicates 100 Mbits/s operation. A low
indicates 10 Mbits/s operation. External buffers are necessary to drive
the LEDs.
Smart Mode Select. At powerup or reset, if this pin is pulled high
through a 4.7 kΩ resistor, the smart mode will be selected which
enables the use of the security feature and redefines the CRS, COL,
and TX_EN10 pins. This pin is internally pulled low through a 50 kΩ
pull-down resistor. The default value is SMART_MODE _SELECT disabled.
When SMART_MODE_SELECT is asserted, the TX_EN10 inputs are
used as the security inputs for both 10 Mbits/s mode and 100 Mbits/s
mode. When security is activated high, the LU3X54FTL will transmit a
jam signal instead of data.
192
SPEEDLED[B]/
BUSED_MII_MODE
I/O
When SMART_MODE_SELECT is asserted high, both the CRS_10
and CRS_100 signals will be output on the CRS_100 pins, and both
the COL_10 and COL_100 signals will be output on the COL_100 pins.
Speed LED[B]. This pin indicates the operating speed of port B on the
LU3X54FTL. A high on this pin indicates 100 Mbits/s operation. A low
indicates 10 Mbits/s operation. External buffers are necessary to drive
the LEDs.
Bused MII Mode Select. At powerup or reset, if the bused MII mode
select pin is pulled high through a 4.7 kΩ resistor, data streams from
ports running at 100 Mbits/s will appear on the single 100 Mbits/s MII
(port A), and data streams from ports running at 10 Mbits/s will appear
at the single 10 Mbits/s serial interface (port B). In addition, control signals TX_EN10, TX_EN100, RX_EN10, RX_EN100, CRS_10, and
CRS_100 become active.
This pin is internally pulled low through a 50 kΩ pull-down resistor. The
default value is bused mode disabled.
26
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Pin Information (continued)
Table 7. Miscellaneous Pins (continued)
Pin
Signal
Type
Description
191
SPEEDLED[A]/
ISOLATE_MODE
I/O
Speed LED[A]. This pin indicates the operating speed of port A on the
LU3X54FTL. A high on this pin indicates 100 Mbits/s operation. A low
indicates 10 Mbits/s operation. External buffers are necessary to drive
the LEDs.
Isolate Mode. As an input, this pin can be used at powerup or reset to
select the isolate operation mode. If this pin is pulled high through a
4.7 kΩ resistor, the LU3X54FTL will powerup or reset to the isolate
mode. (MII outputs to high-impedance state.)
201
H_DUPLED[D]/
FULL_DUP
I/O
198
H_DUPLED[A]/
CLK20_SEL
I/O
87
LSCLK/XTALIN
I
88
XTALOUT
I
55
207—204
MODE[4:0]
I
Lucent Technologies Inc.
This pin is internally pulled low through a 50 kΩ resistor. The default
state is for the LU3X54FTL to powerup or reset in a nonisolate mode.
This pin and register bit [10.0] are ORed together during powerup and
reset.
Half-Duplex LED[D]. When this output is high, it indicates half-duplex
mode. When it is low, it indicates full duplex. External buffers are necessary to drive the LEDs. This output is only valid when the link is up.
Full Duplex. At powerup, this pin may be used to select full-duplex
operation for all four channels by pulling it high through a 4.7 kΩ resistor, if station management is unavailable. This is the same function as
register 0, bit 8. This pin has an internal 50 kΩ pull-down resistor to
default to half duplex for normal operation. This input and the register
bit [0.8] are ORed together during powerup and reset.
Half-Duplex LED[A]. When this output is high, it indicates half-duplex
mode. When low, it indicates full duplex. External buffers are necessary
to drive the LEDs. This output is only valid when the link is up.
20 MHz Clock Select. When this signal is pulled high through a
4.7 kΩ resistor, it will enable the two-clock input mode (20 MHz and
25 MHz). This pin is internally pulled low through a 50 kΩ resistor to set
the default to internal 20 MHz. When low, this signal enables the singleclock input mode (25 MHz with 20 MHz clock internally generated).
This pin has the same function as register 30, bit 6, if station management is unavailable. This input and the register bit [30.6] are ORed
together during powerup and reset.
CMOS Local Symbol Clock. A 25 MHz clock, ±100 ppm, 40%—60%
duty cycle.
Crystal Oscillator Input. A 25 MHz crystal ±25 ppm can be connected
across XTALIN and XTALOUT.
Crystal Oscillator Output. A 25 MHz crystal ±25 ppm can be connected across XTALIN and XTALOUT. If a single-ended external clock
(LSCLK) is connected to XTALIN, the crystal output pin should be left
floating.
Test Mode Select. Reserved for manufacturing testing. These pins
should be tied low for normal operation.
27
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
Pin Information (continued)
Table 7. Miscellaneous Pins (continued)
Pin
Signal
Type
Description
203
RESET
I
199
H_DUPLED[B]/
CRS_SEL
I/O
Full Chip Reset. Reset must be asserted high for at least five LSCLK
cycles. The LU3X54FTL will come out of reset after 400 µs. LSCLK
must remain running during reset.
Half-Duplex LED[B]. When this output is high, it indicates half-duplex
mode. When it is low, it indicates full duplex. External buffers are necessary to drive the LEDs. This output is only valid when the link is up.
Carrier Sense Select. At powerup, this pin may be used to select the
mode of CRS operation. When this pin is pulled high through a 4.7 kΩ
resistor, CRS will be asserted on receive activity only. This is the same
function as register 29, bit 10.
200
54
28
H_DUPLED[C]/
SERIAL_SEL
NC
I/O
—
This pin has an internal 50 kΩ pull-down resistor for normal mode operation (default: CRS asserted on transmit or receive activity). This input
and the register bit [29.10] are ORed together during powerup and
reset.
Half-Duplex LED[C]. When this output is high, it indicates half-duplex
mode. When low, it indicates full duplex. External buffers are necessary
to drive the LEDs. This output is only valid when the link is up.
Serial Select. At powerup, this pin may be used to set the
SERIAL_SEL function of register 30, bit 1 for all four channels by pulling it high through a 4.7 kΩ resistor if station management is unavailable.
This pin has an internal 50 kΩ pull-down resistor for normal mode operation (default). This input and the register bit [30.1] are ORed together
during powerup and reset.
No Connect. Do not connect these pins.
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
MII Station Management
Basic Operations
The primary function of station management is to
transfer control and status information about the
LU3X54FTL to a management entity. This function is
accomplished by the MDC clock input, which has a
maximum frequency of 12.5 MHz, along with the MDIO
pin. This pin (112) requires an external 1.5 kΩ pull-up
resistor.
The management interface (MII) uses MDC and MDIO
to physically transport information between the PHY
and the station management entity.
A specific set of registers and their contents (described
in Table 8) defines the nature of the information transferred across this interface. Frames transmitted on the
MII management interface will have the frame structure
shown in Table 8. The order of bit transmission is from
left to right. Note that reading and writing of the management register must be completed without interruption.
Since the LU3X54FTL is a four-channel device, each of
the management registers is duplicated four times as
depicted in the functional block diagram shown in
Figure 1. To select a particular channel [D:A], write to
that channel’s unique PHY address as described in
Table 9.
MII Management Frames
The fields and format for management frames are
described in the following tables.
Table 8. MII Management Frame Format
Read/Write
(R/W)
Pre
ST
OP
PHYADD
REGAD
TA
DATA
Idle
R
W
1...1
1...1
01
01
10
01
AAAAA
AAAAA
RRRRR
RRRRR
Z0
10
DDDDDDDDDDDDDDDD
DDDDDDDDDDDDDDDD
Z
Z
Table 9. MII Management Frames Field Descriptions
Field
Description
Pre
Preamble. The preamble is a series of 32 ones. The LU3X54FTL will accept frames with no preamble. This is indicated by a 1 in register 1, bit 6.
Start of Frame. The start of frame is indicated by a 01 pattern.
Operation Code. The operation code for a read transaction is 10. The operation code for a write
transaction is 01.
PHY Address. The PHY address is 5 bits, allowing for 32 unique addresses. The first PHY address
bit transmitted and received is the MSB of the address. A station management entity, which is
attached to multiple PHY entities, must have prior knowledge of the appropriate PHY address for
each entity. The address 00000 is the broadcast address. This address will produce a match
regardless of the local address.
ST
OP
PHYADD
The LU3X54FTL maps the PHYADD[2:0] to the most significant 3 bits, while the least significant
2 bits address the channel within the LU3X54FTL as follows:
REGAD
TA
DATA
00: Channel A.
01: Channel B.
10: Channel C.
11: Channel D.
Register Address. The register address is 5 bits, allowing for 32 unique registers within each PHY.
The first register address bit transmitted and received is the MSB of the address.
Turnaround. The turnaround time is a 2-bit time spacing between the register address field and the
data field of a frame to avoid drive contention on MDIO during a read transaction. During a write to
the LU3X54FTL, these bits are driven to a 10 by the station. During a read, the MDIO is not driven
during the first bit time and is driven to a 0 by the LU3X54FTL during the second bit time.
Data. The data field is 16 bits. The first bit transmitted and received is bit 15 of the register being
addressed.
Lucent Technologies Inc.
29
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
MII Station Management (continued)
Management Registers (MR)
Register Overview
The MII management 16-bit register (MR) set is implemented as described in the table below.
Table 10. MII Management Registers (MR)
30
Register
Address
Symbol
Default
(Hex Code)
0
MR0
Control Register
3000
1
MR1
Status Register
7849
2
MR 2
PHY Identifier Register 1
0180
3
MR 3
PHY Identifier Register 2
7641
4
MR4
Autonegotiation Advertisement Register
01E1
5
MR5
Autonegotiation Link Partner Ability Register
(base page)
0000
5
MR5
Autonegotiation Link Partner Ability Register
(next page)
—
6
MR6
Autonegotiation Expansion Register
0000
7
MR7
Next-Page Transmit Register
0000
8—27
MR8—MR27
Reserved
0000
28
MR28
Device-Specific Register 1
—
29
MR29
Device-Specific Register 2
1080
0000
Name
30
MR30
Device-Specific Register 3
31
MR31
Quick Status Register
—
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
MII Station Management (continued)
This section provides a detailed discussion of each management register and its bit definitions.
Table 11. MR0—Control Register Bit Descriptions
Register/Bit1
Type2
Description
0.15 (SW_RESET)
R/W
0.14 (LOOPBACK)
R/W
0.13 (SPEED100)
R/W
0.12 (NWAY_ENA)
R/W
0.11 (PWRDN)
R/W
0.10 (ISOLATE)
R/W
0.9 (REDONWAY)
R/W
0.8 (FULL_DUP)
R/W
0.7 (COLTST)
R/W
0.6:0 (RESERVED)
NA
Reset. Setting this bit to a 1 will reset the entire (all 4 ports, even when only 1
port is addressed) LU3X54FTL. All registers will be set to their default state.
This bit is self-clearing. The default is 0.
Loopback. When this bit is set to 1, no data transmission will take place on
the media. Any receive data will be ignored. The loopback signal path will contain all circuitry up to but not including the PMD. The default value is a 0.
Speed Selection. The value of this bit reflects the current speed of operation
(1 = 100 Mbits/s, 0 = 10 Mbits/s). This bit will only affect operating speed when
the autonegotiation enable bit (register 0, bit 12) is disabled (0). This bit is
ignored when autonegotiation is enabled (register 0, bit 12). This bit is ANDed
with the SPEEDLED[D] pin during powerup and reset. The default state is a 1.
Autonegotiation Enable. The autonegotiation process will be enabled by setting this bit to a 1. The default state is a 1.
Powerdown. The LU3X54FTL may be placed in a low-power state by setting
this bit to a 1, both the 10 Mbits/s transceiver and the 100 Mbits/s transceiver
will be powered down. While in the powerdown state, the LU3X54FTL will
respond to management transactions. The default state is a 0.
Isolate Mode. When this bit is set to a 1, the MII outputs will be brought to the
high-impedance state. The default state is a 0. This bit is ORed with the
SPEEDLED[A]/ISOLATE_MODE pin during powerup and reset.
Restart Autonegotiation. Normally, the autonegotiation process is started at
powerup. The process may be restarted by setting this bit to a 1. The default
state is a 0. The NWAYDONE bit (register 1, bit 5) is reset when this bit goes
to a 1. This bit is self-cleared when autonegotiation restarts.
Duplex Mode. This bit reflects the mode of operation (1 = full duplex, 0 = half
duplex). This bit is ignored when the autonegotiation enable bit (register 0,
bit 12) is enabled. The default state is a 0. This bit is ORed with the
H_DUPLED[D] pin during powerup or reset.
Collision Test. When this bit is set to a 1, the LU3X54FTL will assert the COL
signal in response to TX_EN. This bit should only be set when in loopback
mode.
Reserved. All bits will read 0.
1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the
register, and the name of the instantiated pad is in capital letters.
2. R = read, W = write, NA = not applicable.
Lucent Technologies Inc.
31
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
MII Station Management (continued)
Table 12. MR1—Status Register Bit Descriptions
Register/Bit1
Type2
1.15 (T4ABLE)
R
100Base-T4 Ability. This bit will always be a 0.
R
0: Not able.
1: Able.
100Base-TX Full-Duplex Ability. This bit will always be a 1.
R
0: Not able.
1: Able.
100Base-TX Half-Duplex Ability. This bit will always be a 1.
R
0: Not able.
1: Able.
10Base-T Full-Duplex Ability. This bit will always be a 1.
R
0: Not able.
1: Able.
10Base-T Half-Duplex Ability. This bit will always be a 1.
1.14 (TXFULDUP)
1.13 (TXHAFDUP)
1.12 (ENFULDUP)
1.11 (ENHAFDUP)
1.10:7 (RESERVED)
1.6 (NO_PA_OK)
R
R
1.5 (NWAYDONE)
R
1.4 (REM_FLT)
R
1.3 (NWAYABLE)
R
1.2 (LSTAT_OK)
R
1.1 (JABBER)
R
1.0 (EXT_ABLE)
R
Description
0: Not able.
1: Able.
Reserved. All bits will read as a 0.
Suppress Preamble. This bit is set to a 1 indicating that the LU3X54FTL
accepts management frames with the preamble suppressed.
Autonegotiation Complete. When this bit is a 1, it indicates the autonegotiation process has been completed. The contents of registers MR4, MR5, MR6,
and MR7 are now valid. The default value is a 0. This bit is reset when autonegotiation is started.
Remote Fault. When this bit is a 1, it indicates a remote fault has been
detected. This bit will remain set until cleared by reading the register. The default
is a 0.
Autonegotiation Ability. When this bit is a 1, it indicates the ability to perform
autonegotiation. The value of this bit is always a 1.
Link Status. When this bit is a 1, it indicates a valid link has been established.
This bit has a latching function: a link failure will cause the bit to clear and stay
cleared until it has been read via the management interface.
Jabber Detect. This bit will be a 1 whenever a jabber condition is detected. It
will remain set until it is read, and the jabber condition no longer exists.
Extended Capability. This bit indicates that the LU3X54FTL supports the
extended register set (MR2 and beyond). It will always read a 1.
1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the
register, and the name of the instantiated pad is in capital letters.
2. R = read.
32
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
MII Station Management (continued)
Table 13. MR2, 3—PHY Identifier Registers (1 and 2) Bit Descriptions
Register/Bit1
Type2
Description
2.15:0 (OUI[3:18])
R
3.15:10 (OUI[19:24])
R
3.9:4 (MODEL[5:0])
R
3.3:0 (VERSION[3:0])
R
Organizationally Unique Identifier. The third through the twenty-fourth bit
of the OUI assigned to the PHY manufacturer by the IEEE are to be placed
in bits [2.15:0] and [3.15:10]. The value for bits 15:0 is 0180h.
Organizationally Unique Identifier. The remaining 6 bits of the OUI. The
value for bits 15:10 is 1Dh.
Model Number. 6-bit model number of the device. The model number is
54 DEC.
Revision Number. The value of the present revision number. The value is
01h for the first version.
1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the
register, and the name of the instantiated pad is in capital letters.
2. R = read.
Table 14. MR4—Autonegotiation Advertisement Register Bit Descriptions
Register/Bit1
Type2
4.15 (NEXT_PAGE)
R/W
Next Page. The next-page function is activated by setting this bit to a 1.
This will allow the exchange of additional data. Data is carried by optional
next pages of information.
4.14 (ACK)
R/W
Acknowledge. This bit is the acknowledge bit from the link code word.
4.13 (REM_FAULT)
R/W
Remote Fault. When set to 1, the LU3X54FTL indicates to the link partner
a remote fault condition.
4.12:11 (RESERVED)
NA
Reserved. These bits will read 0.
4.10 (PAUSE)
R/W
Pause. When set to a 1, it indicates that the LU3X54FTL wishes to
exchange flow control information with its link partner.
4.9 (100BASET4)
R/W
100Base-T4. This bit should always be set to 0.
4.8 (100BASET_FD)
R/W
100Base-TX Full Duplex. If written to 1, autonegotiation will advertise that
the LU3X54FTL is capable of 100Base-TX full-duplex operation.
4.7 (100BASETX)
R/W
100Base-TX. If written to 1, autonegotiation will advertise that the
LU3X54FTL is capable of 100Base-TX operation.
4.6 (10BASET_FD)
R/W
10Base-T Full Duplex. If written to 1, autonegotiation will advertise that
the LU3X54FTL is capable of 10Base-T full-duplex operation.
4.5 (10BASET)
R/W
10Base-T. If written to 1, autonegotiation will advertise that the
LU3X54FTL is capable of 10Base-T operation.
4.4:0 (SELECT)
R/W
Selector Field. Reset with the value 00001 for IEEE 802.3.
Description
1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the
register, and the name of the instantiated pad is in capital letters.
2. R = read, W = write, NA = not applicable.
Lucent Technologies Inc.
33
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
MII Station Management (continued)
Table 15. MR5—Autonegotiation Link Partner (LP) Ability Register (Base Page) Bit Descriptions
Register/Bit1
Type2
Description
5.15 (LP_NEXT_PAGE)
R
5.14 (LP_ACK)
R
5.13 (LP_REM_FAULT)
R
5.12:5
(LP_TECH_ABILITY)
R
5.4:0 (LP_SELECT)
R
Link Partner Next Page. When this bit is set to 1, it indicates that the link
partner wishes to engage in next-page exchange.
Link Partner Acknowledge. When this bit is set to 1, it indicates that the
link partner has successfully received at least three consecutive and consistent FLP bursts.
Remote Fault. When this bit is set to 1, it indicates that the link partner has
a fault.
Technology Ability Field. This field contains the technology ability of the
link partner. These bits are similar to the bits defined for the MR4 register
(see Table 14).
Selector Field. This field contains the type of message sent by the link partner. For IEEE 802.3u compliant link partners, this field should read 00001.
1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the
register, and the name of the instantiated pad is in capital letters.
2. R = read.
Table 16. MR5—Autonegotiation Link Partner (LP) Ability Register (Next Page) Bit Descriptions
Register/Bit1
Type2
Description
5.15 (LP_NEXT_PAGE)
R
5.14 (LP_ACK)
R
5.13 (LP_MES_PAGE)
R
5.12 (LP_ACK2)
R
5.11 (LP_TOGGLE)
R
5.10:0 (MCF)
R
Next Page. When this bit is set to a logic 0, it indicates that this is the last
page to be transmitted. A logic 1 indicates that additional pages will follow.
Acknowledge. When this bit is set to a logic 1, it indicates that the link
partner has successfully received its partner’s link code word.
Message Page. This bit is used by the NEXT_PAGE function to differentiate a message page (logic 1) from an unformatted page (logic 0).
Acknowledge 2. This bit is used by the NEXT_PAGE function to indicate
that a device has the ability to comply with the message (logic 1) or not
(logic 0).
Toggle. This bit is used by the arbitration function to ensure synchronization with the link partner during next-page exchange. Logic 0 indicates that
the previous value of the transmitted link code word was logic 1. Logic 1
indicates that the previous value of the transmitted link code word was
logic 0.
Message/Unformatted Code Field. With these 11 bits, there are 2048 possible messages. Message code field definitions are described in annex 28C of
the IEEE 802.3u standard.
1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the
register, and the name of the instantiated pad is in capital letters.
2. R = read.
34
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
MII Station Management (continued)
Table 17. MR6—Autonegotiation Expansion Register Bit Descriptions
Register/Bit1
Type2
Description
6.15:5 (RESERVED)
6.4 (PAR_DET_FAULT)
R
R/LH
6.3
(LP_NEXT_PAGE_ABLE)
6.2 (NEXT_PAGE_ABLE)
R
R
6.1 (PAGE_REC)
R/LH
6.0 (LP_NWAY_ABLE)
R
Reserved.
Parallel Detection Fault. When this bit is set to 1, it indicates that a fault has
been detected in the parallel detection function. This fault is due to more than
one technology detecting concurrent link conditions. This bit can only be
cleared by reading this register.
Link Partner Next Page Able. When this bit is set to 1, it indicates that the
link partner supports the next-page function.
Next Page Able. This bit is set to 1, indicating that this device supports the
next-page function.
Page Received. When this bit is set to 1, it indicates that a NEXT_PAGE has
been received.
Link Partner Autonegotiation Capable. When this bit is set to 1, it indicates
that the link partner is autonegotiation capable.
1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the
register, and the name of the instantiated pad is in capital letters.
2. R = read, LH = latched high.
Table 18. MR7—Next-Page Transmit Register Bit Descriptions
Register/Bit1
Type2
Description
7.15 (NEXT_PAGE)
R/W
7.14 (ACK)
7.13 (MESSAGE)
R
R/W
7.12 (ACK2)
R/W
Next Page. This bit indicates whether or not this is the last NEXT_PAGE to be transmitted. When this bit is 0, it indicates that this is the last NEXT_PAGE. When this bit is 1, it
indicates there is an additional NEXT_PAGE.
Acknowledge. This bit is the acknowledge bit from the link code word.
Message Page. This bit is used to differentiate a message page from an unformatted
page. When this bit is 0, it indicates an unformatted page. When this bit is 1, it indicates
a formatted page.
Acknowledge 2. This bit is used by the next-page function to indicate that a device has
the ability to comply with the message. It is set as follows:
■
7.11 (TOGGLE)
R
When this bit is 0, it indicates the device cannot comply with the message.
■ When this bit is 1, it indicates the device will comply with the message.
Toggle. This bit is used by the arbitration function to ensure synchronization with the link
partner during next-page exchange.
This bit will always take the opposite value of the toggle bit in the previously exchanged
link code word:
7.10:0 (MCF)
R/W
■
If the bit is a logic 0, the previous value of the transmitted link code word was a logic 1.
■
If the bit is a 1, the previous value of the transmitted link code word was a 0.
The initial value of the toggle bit in the first next-page transmitted is the inverse of the
value of bit 11 in the base link code word, and may assume a value of 1 or 0.
Message/Unformatted Code Field. With these 11 bits, there are 2048 possible messages. Message code field definitions are described in annex 28C of the IEEE 802.3u
standard.
1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the
register, and the name of the instantiated pad is in capital letters.
2. R = read, W = write.
Lucent Technologies Inc.
35
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
MII Station Management (continued)
Table 19. MR28—Device-Specific Register 1 (Status Register) Bit Descriptions
Register/Bit1
Type2
Description
28.15:9 (R28[15:9])
28.8 (BAD_FRM)
R
R/LH
Unused. Read as 0.
Bad Frame. If this bit is a 1, it indicates a packet has been received without an
SFD. This bit is only valid in 10 Mbits/s mode.
28.7 (CODE)
28.6 (APS)
R/LH
R
28.5 (DISCON)
R/LH
28.4 (UNLOCKED)
R/LH
28.3 (RXERR_ST)
R/LH
28.2 (FRC_JAM)
R/LH
28.1 (LNK100UP)
R
28.0 (LNK10UP)
R
This bit is latching high and will only clear after it has been read or the device
has been reset. This bit defaults to 0.
Code Violation. When this bit is a 1, it indicates a Manchester code violation
has occurred. The error code will be output on the RXD lines. Refer to Table 3
for a detailed description of the RXD pin error codes. This bit is only valid in
10 Mbits/s mode.
This bit is latching high and will only clear after it has been read or the device
has been reset. This bit defaults to 0.
Autopolarity Status. When register 30, bit 3 is set and this bit is a 1, it indicates the LU3X54FTL has detected and corrected a polarity reversal on the
twisted pair.
If the APF_EN bit (register 30, bit 3) is set, the reversal will be corrected inside
the LU3X54FTL. This bit is not valid in 100 Mbits/s operation. This bit defaults
to 0.
Disconnect. If this bit is a 1, it indicates a disconnect. This bit will latch high
until read. This bit is only valid in 100 Mbits/s mode. This bit defaults to 0.
Unlocked. Indicates that the TX scrambler lost lock. This bit will latch high until
read. This bit is only valid in 100 Mbits/s mode. This bit defaults to 0.
RX Error Status. Indicates a false carrier. This bit will latch high until read. This
bit is only valid in 100 Mbits/s mode. This bit defaults to 0.
Force Jam. This bit will latch high until read. This bit is only valid in 100 Mbits/s
mode. This bit defaults to 0.
Link Up 100. This bit, when set to a 1, indicates a 100 Mbits/s transceiver is up
and operational. This bit defaults to 0.
Link Up 10. This bit, when set to a 1, indicates a 10 Mbits/s transceiver is up
and operational. This bit defaults to 0.
1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the
register, and the name of the instantiated pad is in capital letters.
2. R = read, LH = latched high.
36
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
MII Station Management (continued)
Table 20. MR29—Device-Specific Register 2 (100 Mbits/s Control) Bit Descriptions
Register/Bit1
Type2
Description
29.15 (LOCALRST)
R/W
29.14 (RST1)
29.13 (RST2)
29.12 (100OFF)
R/W
R/W
R/W
29.11 (RESERVED)
29.10 (CRS_SEL)
R/W
R/W
29.9 (LINK_ERR)
R/W
29.8 (PKT_ERR)
R/W
29.7 (PULSE_STR)
R/W
29.6
(ENC_DEC_BYPASS)
R/W
29.5 (SAB)
R/W
29.4
(SCRAM_DESC_BYPASS)
R/W
29.3 (CARIN_EN)
R/W
29.2 (JAM_COL)
R/W
29.1 (FEF_EN)
R/W
29.0 FX_MODE_EN
R/W
Management Reset. This is the local management reset bit. Writing a logic 1 to
this bit will cause register zero and registers 28 and 29 to be reset to their default
values. This bit is self-clearing. Default state is 0.
Generic Reset 1. This register is used for manufacture test only. Default state is 0.
Generic Reset 2. This register is used for manufacture test only. Default state is 0.
100 Mbits/s Transmitter Off. When this bit is set to 0, it forces TPOUT+[D:A] low
and TPOUT–[D:A] high. This bit defaults to 1.
Reserved. Program to zero.
Carrier Sense Select. CRS will be asserted on receive only when this bit is set to
a 1. If this bit is set to logic 0, CRS will by asserted on receive or transmit. This bit
is ORed with the H_DUPLED[B] pin during powerup and reset. Default state is 0.
Link Error Indication. When this bit is a 1, a link error code will be reported on
RXD[3:0] of the LU3X54FTL when RX_ER is asserted on the MII. The specific
error codes are listed in the RXD pin description. If it is 0, it will disable this function. Default state is 0.
Packet Error Indication Enable. When this bit is a 1, a packet error code, which
indicates that the scrambler is not locked, will be reported on RXD[3:0] of the
LU3X54FTL when RX_ER is asserted on the MII. When this bit is 0, it will disable
this function. Default state is 0.
Pulse Stretching. When this bit is set to 1, the COLED[D:A], TXLED[D:A], and
RXLED[D:A] output signal will be stretched between approximately 42 ms—84 ms.
If this bit is set to 0, it will disable this feature. Default state is 1.
Encoder/Decoder Bypass. When this bit is set to 1, the 4B/5B encoder and
5B/4B decoder function will be disabled. This bit is ORed with the TXLED[C] pin
during powerup and reset. Default state is 0.
Symbol Aligner Bypass. When this bit is set to 1, the aligner function will be disabled. Default state is 0.
Scrambler/Descrambler Bypass. When this bit is set to 1, the scrambling/
descrambling functions will be disabled. This bit is ORed with the TXLED[B] pin
during powerup and reset. Default state is 0.
Carrier Integrity Enable. When this bit is set to a 1, carrier integrity is enabled.
This bit is ORed with the TXLED[D] pin during powerup and reset. Default state
is 0.
Jam Enable. When this bit is a 1, it enables JAM associated with carrier integrity
to be ORed with COL. Default state is 0.
Far-End Fault Enable. This bit is used to enable the far-end fault detection and
transmission capability. This capability may only be used if autonegotiation is disabled. This capability is to be used only with media which does not support autonegotiation. Setting this bit to 1 enables far-end fault detection and generation.
Logic 0 will disable the function. Default state is 0.
FX Mode Enable. When set high, this bit will enable the FX mode (10Base-T and
100Base-TX disabled). When low, it will enable 10Base-T and 100Base-TX mode
(100Base-FX mode disabled). This bit defaults to zero. It is ORed with the FX
mode enable pin.
1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the
register, and the name of the instantiated pad is in capital letters.
2. R = read, W = write.
Lucent Technologies Inc.
37
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
MII Station Management (continued)
Table 21. MR30—Device-Specific Register 3 (10 Mbits/s Control) Bit Descriptions
Register/Bit1
Type2
Description
30.15:7 (R28[15:7])
30.6 (CLK_SEL)
R/W
R/W
30.5 (HBT_EN)
R/W
30.4 (ELL_EN)
R/W
30.3 (APF_DIS)
R/W
Unused. Read as 0.
20 MHz Clock Select. When this bit is a 1, it enables the two-clock input mode
(20 MHz and 25 MHz). When this bit is a 0, it enables the single-clock input
mode 25 MHz (with 20 MHz clock internally generated). Default state is 0.
Heartbeat Enable. When this bit is a 1, the heartbeat function will be
enabled. Valid in 10 Mbits/s mode only. Default state is 0.
Extended Line Length Enable. When this bit is a 1, the receive squelch
levels are reduced from a nominal 435 mV to 350 mV, allowing reception of
signals with a lower amplitude. Valid in 10 Mbits/s mode only. Default state is
0.
Autopolarity Function Disable. When this bit is a 0 and the LU3X54FTL is in
10 Mbits/s mode, the autopolarity function will determine if the TP link is wired
with a polarity reversal.
30.2 (REF_SEL)
R/W
30.1 (SERIAL _SEL)
R/W
30.0 (ENA_NO_LP)
R/W
If there is a polarity reversal, the LU3X54FTL will assert the APS bit (register
28, bit 6) and correct the polarity reversal. If this bit is a 1 and the device is in
10 Mbits/s mode, the reversal will not be corrected. Default state is 0.
Reference Select. When this bit is a 1, the external 10 MHz reference input
clock REF10 is used for phase alignment. Default state is 0.
Serial Select. When this bit is set to a 1, 10 Mbits/s serial mode will be
selected. When the LU3X54FTL is in 100 Mbits/s mode, this bit will be
ignored. This bit is ORed with the H_DUPLED[C] pin during powerup and
reset. Default state is 0.
No Link Pulse Mode. Setting this bit to a 1 will allow 10 Mbits/s operation
with link pulses disabled. If the LU3X54FTL is configured for 100 Mbits/s operation, setting this bit will not affect operation. This bit is ORed with the
LINKLED[A] pin during powerup and reset. Default state is 0.
1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the
register, and the name of the instantiated pad is in capital letters.
2 R = read, W = write.
38
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
MII Station Management (continued)
Table 22. MR31—Device-Specific Register 4 (Quick Status) Bit Descriptions
Register/Bit1
Type2
Description
31.15 (ERROR)
R
31.14 (RXERR_ST)/
(LINK_STAT_CHANGE)
R
31.13 (REM_FLT)
R
31.12 (UNLOCKED)/
(JABBER)
R
31.11 (LSTAT_OK)
R
31.10 (PAUSE)
R
31.9 (SPEED100)
R
31.8 (FULL_DUP)
R
31.7 (INT_CONF)
R/W
31.6 (INT_MASK)
R/W
31.5:3
(LOW_AUTO__STATE)
R
Receiver Error. When this bit is a 1, it indicates that a receive error has been
detected. This bit is valid in 100 Mbits/s only. This bit will remain set until cleared by
reading the register. Default is a 0.
False Carrier. When bit [31.7] is set to 0 and this bit is a 1, it indicates that the carrier
detect state machine has found a false carrier. This bit is valid in 100 Mbits/s only. This
bit will remain set until cleared by reading the register. Default is 0.
Link Status Change. When bit [31.7] is set to a 1, this bit is redefined to become the
LINK_STAT_CHANGE bit and goes high whenever there is a change in link status (bit
[31.11] changes state).
Remote Fault. When this bit is a 1, it indicates a remote fault has been detected. This
bit will remain set until cleared by reading the register. Default is a 0.
Unlocked/Jabber. If this bit is set when operating in 100 Mbits/s mode, it indicates
that the TX descrambler has lost lock. If this bit is set when operating in 10 Mbits/s
mode, it indicates a jabber condition has been detected. This bit will remain set until
cleared by reading the register.
Link Status. When this bit is a 1, it indicates a valid link has been established. This bit
has a latching low function: a link failure will cause the bit to clear and stay cleared
until it has been read via the management interface.
Link Partner Pause. When this bit is set to a 1, it indicates that the LU3X54FTL
wishes to exchange flow control information.
Link Speed. When this bit is set to a 1, it indicates that the link has negotiated to
100 Mbits/s. When this bit is a 0, it indicates that the link is operating at 10 Mbits/s.
Duplex Mode. When this bit is set to a 1, it indicates that the link has negotiated to
full-duplex mode. When this bit is a 0, it indicates that the link has negotiated to halfduplex mode.
Interrupt Configuration. When this bit is set to a 0, it defines bit [31.14] to be the
RXERR_ST bit and the interrupt pin (MASK_STAT_INT) goes high whenever any of
bits [31.15:12] go high, or bit [31.11] goes low. When this bit is set high, it redefines
bit [31.14] to become the LINK_STAT_CHANGE bit, and the interrupt pin
(MASK_STAT_INT) goes high only when the link status changes (bit [31.14] goes
high). This bit defaults to 0.
Interrupt Mask. When set high, no interrupt is generated by this channel under any
condition. When set low, interrupts are generated according to bit [31.7].
Lowest Autonegotiation State. These 3 bits report the state of the lowest autonegotiation state reached since the last register read, in the priority order defined below:
31.2:0
(HI_AUTO_STATE)
R
000: Autonegotiation enable.
001: Transmit disable or ability detect.
010: Link status check.
011: Acknowledge detect.
100: Complete acknowledge.
101: FLP link good check.
110: Next-page wait.
111: FLP link good.
Highest Autonegotiation State. These 3 bits report the state of the highest autonegotiation state reached since the last register read, as defined above for bit [31.5:3].
1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the
register, and the name of the instantiated pad is in capital letters.
2 R = read; W = write.
Lucent Technologies Inc.
39
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
MII Station Management (continued)
Unmanaged Operations
The LU3X54FTL allows the user to set some of the station management functions during powerup or reset by
strapping outputs high or low through weak resistors (50 kΩ). Table 23 shows the functions and their associated
output pin. For detailed information on the function of these output pins, refer to the section on management registers described earlier in this data sheet. Also, information on how these output pins should be strapped is discussed in the Pin Descriptions section (Table 3 through Table 7).
Table 23. Output Pins
Function (Register/Bit)
Pin
Internal Pull-Up/Pull-Down
PHYADD[2:0]
NO_LP
SPEED
CARIN_EN
ENC_DEC_BYPASS
SCRAM_DESC_BYPASS
REF_SEL
CLK20_SEL
FULL _DUP
SERIAL_SEL
CRS_SEL
BUSED_MII_MODE
SMART_MODE_SELECT
ISOLATE_MODE
FX_MODE_EN
RESERVED
LINKLED[D:B]
LINKLED[A]
SPEEDLED[D]
TXLED[D]
TXLED[C]
TXLED[B]
TXLED[A]
H_DUPLED[A]
H_DUPLED[D]
H_DUPLED[C]
H_DUPLED[B]
SPEEDLED[B]
SPEEDLED[C]
SPEEDLED[A]
RXLED[D:A]
COLED[B:A]
None
50 kΩ down
100 kΩ up
50 kΩ down
50 kΩ down
50 kΩ down
50 kΩ down
50 kΩ down
50 kΩ down
50 kΩ down
50 kΩ down
50 kΩ down
50 kΩ down
50 kΩ down
50 kΩ down
50 kΩ down
Mode Select
Table 24. LU3X54FTL Modes
MODE[4:0]
00000
00001—11111
40
Description
Normal operation
Reserved
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Absolute Maximum Ratings (TA = 25 °C)
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operational sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Table 25. Absolute Maximum Ratings
Parameter
Ambient Operating Temperature
Storage Temperature
Power Dissipation
Voltage on Any Pin with Respect to Ground
Maximum Supply Voltage
Symbol
Min
Max
Unit
TA
Tstg
PD
—
—
0
–40
—
–0.5
—
70
125
3.5
DD
V + 0.5
5.5
°C
°C
W
V
V
Table 26. Operating Conditions
Parameter
Operating Supply Voltage
Power Dissipation:
All Ports 100 Mbits/s TX
All Ports 100 Mbits/s FX
All Ports 10 Mbits/s
All Ports Autonegotiating
Symbol
—
Min
4.75
Typ*
5.0
Max
5.25
Unit
V
PD
PD
PD
PD
—
—
—
—
3.0
2.2
2.0
1.5
—
—
—
—
W
W
W
W
* Typical power dissipations are specified at 5.0 V and 25 °C. This is the power dissipated by the LU3X54FTL. An additional 0.2 W of power is
required for the external twisted-pair driver termination resistors.
Electrical Characteristics
The following specifications apply for VDD = 5 V ± 5%, VDD3 = 5 V ± 5% or VDD3 = 3.3 V ± 5%.
Table 27. dc Characteristics
Parameter
Symbol
Min
Typ
Max
Unit
TTL Inputs: VDD3 = 3.3 V ± 5%
Input High Voltage
Input Low Voltage
Input High Current
Input Low Current
Input Leakage Current
VIH
VIL
IIH
IIL
IL
2.0
—
—
—
—
—
—
—
—
—
—
0.8
50
–400
50
V
V
µA
µA
µA
CMOS Inputs: VDD3 = 5.0 V ± 5%
Input High Voltage
Input Low Voltage
Input High Current
Input Low Current
Input Leakage Current
VIH
VIL
IIH
IIL
IL
3.0
—
—
—
—
—
—
—
—
—
—
0.5
1
–1
1
V
V
µA
µA
µA
TTL Outputs: VDD3 = 3.3 V ± 5% or VDD3 = 5.0 V ± 5%
Output High Voltage
Output Low Voltage
Output Short-circuit Current
VOH
VOL
ISC
2.4
—
–4
—
—
—
—
0.45
–85
V
V
mA
Lucent Technologies Inc.
41
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
Electrical Characteristics (continued)
Table 27. dc Characteristics (continued)
Parameter
Symbol
Min
Typ
Max
Unit
10 Mbits/s Twisted Pair: Input Voltage
VDIFF
0.35
—
2.0
V
100 Mbits/s Twisted Pair: Input Voltage
VDIFF
—
—
1.5
V
10 Mbits/s Twisted Pair: Output Current
VDIFF
45
50
55
mA
100 Mbits/s Twisted Pair: Output Current
VDIFF
19
20
21
mA
Timing Characteristics (Preliminary)
Table 28. MII Management Interface Timing (25 pF Load)
Name
t1
t2
t3
t4
t5
t6
Parameter
MDIO Valid to Rising Edge of MDC (setup)
Rising Edge of MDC to MDIO Invalid (hold)
MDC Falling Edge to MDIO Valid (prop. delay)
MDC High*
MDC Low*
MDC Period*
Min
Typ
Max
Unit
10
10
0
—
40
80
—
—
—
200
200
400
—
—
40
—
—
—
ns
ns
ns
ns
ns
ns
* When operating MDC above 6.25 MHz, MDC must be synchronous with LSCLK and have a setup time of 15 ns and a hold time of 5 ns,
with respect to LSCLK.
MDC
MDIO
t1
t2
5-4959(F).r1
Figure 9. MDIO Input Timing
t6
MDC
t5
t4
MDIO
t3
5-4960(F).c
Figure 10. MDIO Output Timing
42
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Timing Characteristics (Preliminary) (continued)
<R>
<Z>
<O>
MDC
MDIO
5-5312(F)
Note: MDIO turnaround (TA) time is a 2-bit time spacing between the register address field, and the data field of a frame to avoid drive contention on MDIO during a read transaction. During a write to the LU3X54FTL, these bits are driven to a 10 by the station. During a read, the
MDIO is not driven during the first bit time and is driven to a 0 by the LU3X54FTL during the second bit time.
Figure 11. MDIO During TA (Turnaround) of a Read Transaction
Table 29. MII Data Timing (25 pF Load)
Name
Parameter
Min
Typ
Max
Unit
t1
t2
t3
t4
t5
t6
t7
t8
t9
t10
t11
t12
t13
t14
RXD[3:0], RX_ER, RX_DV Valid to RX_CLK High
RX_CLK High to RXD[3:0], RX_DV, RX_ER Invalid
RX_CLK High
RX_CLK Low
RX_CLK Period
TX_CLK High
TX_CLK Low
TX_CLK Period
TXD, TX_EN, TX_ER, Setup to TX_CLK
TXD, TX_EN, TX_ER, Hold to TX_CLK
TXD, TX_EN, TX_ER, Setup to LSCLK*
TXD, TX_EN, TX_ER, Hold to LSCLK*
TX_CLK Skew from LSCLK
First Bit of J on TPIN± While Transmitting Data to COL
Assert (half-duplex mode)
First Bit of T Received on TPIN± While Transmitting to COL
Deasserted (half-duplex mode)
10/100
10/100
14/180
14/180
—
14/180
14/180
—
18/140
0/0
12
0
TBD
—
—
—
—
—
40
—
—
40
—
—
—
—
—
—
—
—
26/220
26/220
—
26/220
26/220
—
—
—
—
—
TBD
170
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
—
—
210
ns
t15
* 100 Mbits/s only.
Lucent Technologies Inc.
43
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
Timing Characteristics (Preliminary) (continued)
t5
t4
t3
RX_CLK
RXD[3:0]
RX_DV
RX_ER
t1
t2
t8
TX_CLK
t7
TXD[3:0]
TX_EN
TX_ER
t6
t9
t10
LSCLK
TXD[3:0]
TX_EN
TX_ER
t11
t12
LSCLK
TX_CLK
t13
1st BIT OF J
1st BIT OF T
TPIN±
COL
t14
t15
5-5432(F).r2
Figure 12. MII Timing Requirements for LU3X54FTL
44
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Timing Characteristics (Preliminary) (continued)
Table 30. Serial 10 Mbits/s Timing for TPIN, CRS, and RX_CLK
Name
t16
t17
t18
t19
Parameter
TPIN Activity to CRS Assertion
TPIN Activity to RX_CLK Valid
IDL to CRS Deassertion
Dead Signal to CRS Deassertion
Min
Max
Unit
40
800
200
400
500
2300
550
1000
ns
ns
ns
ns
(RECEIVE—DEAD SIGNAL)
(NOT IDL)
(RECEIVE—START OF PACKET)
(RECEIVE—END OF PACKET)
TPIN±
IDL
CRS
t16
t19
t18
RX_CLK
t17
5-5293(F).cr3
Figure 13. Serial 10 Mbits/s Timing for TPIN, CRS, and RX_CLK
Table 31. Serial 10 Mbits/s Timing for TX_EN, TPOUT, CRS, and RX_CLK
Name
t20
t21
t22
t23
t24
Parameter
TX_EN Asserted to Transmit Pair Activity
TX_EN Asserted to CRS Asserted Due to Internal Loopback
TX_EN Asserted to RX_CLK Valid Due to Internal Loopback
TX_EN Deasserted to IDL Transmission
IDL Pulse Width
(TRANSMIT—START OF PACKET)
Min
Max
Unit
50
5
1000
50
250
400
1900
1700
300
350
ns
ns
ns
ns
ns
(TRANSMIT—END OF PACKET)
TX_EN
TPOUT±
IDL
t20
t23
t24
CRS
t21
RX_CLK
t22
5-5293(F).dr3
Figure 14. Serial 10 Mbits/s Timing for TX_EN, TPOUT, CRS, and RX_CLK
Lucent Technologies Inc.
45
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
Timing Characteristics (Preliminary) (continued)
Table 32. Serial 10 Mbits/s Timing for TX_EN, TPIN, and COL
Name
Parameter
Min
Max
Unit
t25
t26
Time to Assert COL; LU3X54FTL Is Transmitting; Receive Activity Starts
Time to Deassert COL; LU3X54FTL Is Transmitting; Receive Activity
Ceases
Time to Assert COL; LU3X54FTL Is Receiving; Transmit Activity Starts
Time to Deassert COL; LU3X54FTL Is Receiving; Transmit Activity Ceases
COL Pulse Width
40
300
400
900
ns
ns
5
5
100
400
900
—
ns
ns
ns
t27
t28
t29
(TRANSMITTING—RECEIVE COLLISION DETECTED)
(RECEIVING—TRANSMIT COLLISON DETECTED)
TX_EN
TPIN±
IDL
COL
t25
t26
t27
t28
t29
5-5293(F).er3
Figure 15. Serial 10 Mbits/s Timing for TX_EN, TPIN, and COL
46
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Timing Characteristics (Preliminary) (continued)
Table 33. Serial 10 Mbits/s Timing for RX_CLK, CRS, RXD, TX_CLK, TX_EN, and TXD (25 pF Load)
Name
Parameter
t30
t31
t32
t33
t34
t35
t36
RXD Setup Before RX_CLK Rising Edge
RXD Held Past RX_CLK Edge
RX_CLK Low to CRS Deassertion (at end of received packet)
TX_EN Setup Before TX_CLK Rising Edge
TX_EN Held Past TX_CLK Rising Edge
TXD Setup Before TX_CLK Rising Edge
TXD Held Past TX_CLK Rising Edge
Min
Max
Unit
30
30
40
30
0
30
0
—
—
—
—
—
—
—
ns
ns
ns
ns
ns
ns
ns
RX_CLK
CRS
t32
RXD
t30
(START OF PACKET)
t31
(END OF PACKET)
TX_CLK
t33
t34
TX_EN
t35
t36
TXD
LAST BIT
5-2736(C).b
Figure 16. Serial 10 Mbits/s Timing for RX_CLK, CRS, RXD, TX_CLK, TX_EN, and TXD
Lucent Technologies Inc.
47
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
Timing Characteristics (Preliminary) (continued)
Table 34. Serial 10 Mbits/s Timing for RX_CLK and TX_CLK (25 pF Load)
Name
t37
t38
t39
t40
Parameter
RX_CLK Low Pulse Width
RX_CLK High Pulse Width
TX_CLK Low Pulse Width
TX_CLK High Pulse Width
t37
t38
t39
t40
Min
Max
Unit
45
45
45
45
55
55
55
55
ns
ns
ns
ns
RX_CLK
TX_CLK
5-2737(F).br3
Figure 17. Serial 10 Mbits/s Timing Diagram for RX_CLK and TX_CLK
48
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Timing Characteristics (Preliminary) (continued)
Table 35. 100 Mbits/s MII Transmit Timing
Name
Parameter
Min
Max
Unit
t41
t42
t43
Rising Edge of TX_CLK Following TX_EN Assertion to CRS Assertion
Rising Edge of TX_CLK Following TX_EN Assertion to TPOUT±
Rising Edge of TX_CLK Following TX_EN Deassertion to CRS Deassertion
—
—
—
40
60
40
ns
ns
ns
TX_CLK
TX_EN
TXD[3:0]
t43
t41
CRS
1st BIT OF J
1st BIT OF T
t42
TPOUT±
5-3745(F).br4
Figure 18. 100 Mbits/s MII Transmit Timing
Lucent Technologies Inc.
49
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
Timing Characteristics (Preliminary) (continued)
Table 36. 100 Mbits/s MII Receive Timing
Name
Parameter
Min
Max
Unit
t44
t45
t46
t47
TPIN± 1st Bit of J Receive Activity to CRS Asserted
TPIN± Receive Activity to Receive Data Valid
TPIN± Receive Activity Cease (1st bit of T) to CRS Deasserted
TPIN± Receive Activity Cease (1st bit of T) to Receive Data Not Valid
—
—
—
—
170
210
210
210
ns
ns
ns
ns
1st BIT OF J
1st BIT OF T
TPIN±
t46
t44
CRS
RX_CLK
t45
RX_DV
t47
RX_ER
RXD[3:0]
5-3747(F).br4
Figure 19. 100 Mbits/s MII Receive Timing
50
Lucent Technologies Inc.
Data Sheet
July 2000
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Outline Diagram
208-Pin SQFP
Dimensions are in millimeters.
30.60 ± 0.20
28.00 ± 0.20
PIN #1 IDENTIFIER ZONE
208
157
1
1.30 REF
156
0.25
GAGE PLANE
SEATING PLANE
0.50/0.75
28.00
± 0.20
DETAIL A
30.60
± 0.20
0.090/0.200
105
52
0.17/0.27
53
0.10
104
DETAIL A
M
DETAIL B
DETAIL B
3.40 ± 0.20
4.10 MAX
SEATING PLANE
0.08
0.50 TYP
0.25 MIN
5-2196(F).r13
Lucent Technologies Inc.
51
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
Ordering Information
Device Code
Comcode
Package
Temperature
LU3X54FTL-HS208-DB
108420167
208-Pin SQFPH (Heat Spreader)
0 °C to 70 °C
For additional information, contact your Microelectronics Group Account Manager or the following:
http://www.lucent.com/micro
INTERNET:
[email protected]
E-MAIL:
N. AMERICA: Microelectronics Group, Lucent Technologies Inc., 555 Union Boulevard, Room 30L-15P-BA, Allentown, PA 18109-3286
1-800-372-2447, FAX 610-712-4106 (In CANADA: 1-800-553-2448, FAX 610-712-4106)
ASIA PACIFIC: Microelectronics Group, Lucent Technologies Singapore Pte. Ltd., 77 Science Park Drive, #03-18 Cintech III, Singapore 118256
Tel. (65) 778 8833, FAX (65) 777 7495
CHINA:
Microelectronics Group, Lucent Technologies (China) Co., Ltd., A-F2, 23/F, Zao Fong Universe Building, 1800 Zhong Shan Xi Road,
Shanghai 200233 P. R. China Tel. (86) 21 6440 0468, ext. 325, FAX (86) 21 6440 0652
JAPAN:
Microelectronics Group, Lucent Technologies Japan Ltd., 7-18, Higashi-Gotanda 2-chome, Shinagawa-ku, Tokyo 141, Japan
Tel. (81) 3 5421 1600, FAX (81) 3 5421 1700
EUROPE:
Data Requests: MICROELECTRONICS GROUP DATALINE: Tel. (44) 1189 324 299, FAX (44) 1189 328 148
Technical Inquiries: GERMANY: (49) 89 95086 0 (Munich), UNITED KINGDOM: (44) 1344 865 900 (Bracknell),
FRANCE: (33) 1 48 83 68 00 (Paris), SWEDEN: (46) 8 600 7070 (Stockholm), FINLAND: (358) 9 4354 2800 (Helsinki),
ITALY: (39) 2 6608131 (Milan), SPAIN: (34) 1 807 1441 (Madrid)
Lucent Technologies Inc. reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No
rights under any patent accompany the sale of any such product(s) or information.
Copyright © 2000 Lucent Technologies Inc.
All Rights Reserved
Printed in U.S.A.
July 2000
DS00-354LAN (Replaces DS98-277LAN)