Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Introduction ■ Autopolarity detection and correction ■ Adjustable squelch level for extended line length capability (two levels) ■ Interfaces with IEEE 802.3u media independent interface (MII) or a serial 10 Mbits/s 7-pin interface ■ On-chip filtering eliminates the need for external filters ■ Half- and full-duplex operations Configuration The LU3X54FTL is a four-channel, single-chip complete transceiver designed specifically for dual-speed 10Base-T, 100Base-TX, and 100Base-FX repeaters and switches. It supports simultaneous operation in three separate IEEE standard modes: 10Base-T, 100Base-TX, and 100Base-FX. The LU3X54FTL provides a 3.3 V or 5.0 V MII interface logic level. Each channel implements: ■ 10Base-T transceiver function of IEEE 802.3. ■ Physical coding sublayer (PCS) of IEEE 802.3u. ■ Physical medium attachment (PMA) of IEEE 802.3u. ■ Autonegotiation of IEEE 802.3u. ■ MII management of IEEE 802.3u. ■ Physical medium dependent (PMD) of IEEE 802.3. The LU3X54FTL supports operations over two pairs of unshielded twisted-pair (UTP) cable (10Base-T and 100Base-TX), and over fiber-optic cable (100Base-FX). It has been designed with a flexible system interface that allows configuration for optimum performance and effortless design. The individual per-port interface can be configured as 100 Mbits/s MII, 10 Mbits/s MII, 7-pin 10 Mbits/s serial, or bused mode. Features 100 Mbits/s TX Transceiver ■ Compatible with IEEE 802.3u MII (clause 22), PCS (clause 23), PMA (clause 24), autonegotiation (clause 28), and PMD (clause 25) specifications ■ Scrambler/descrambler bypass ■ Encoder/decoder bypass ■ 3-statable MII in 100 Mbits/s mode ■ Selectable carrier sense signal generation (CRS) asserted during either transmission or reception in half duplex (CRS asserted during reception only in full duplex) ■ Selectable MII or 5-bit code group interface ■ Full- or half-duplex operations ■ Optional carrier integrity monitor (CIM) ■ On-chip filtering and adaptive equalization that eliminates the need for external filters 100 Mbits/s FX Transceiver ■ 10 Mbits/s Transceiver ■ Compatible with IEEE 802.3U 100Base-FX standard Compatible with IEEE * 802.3 10Base-T standard for twisted-pair cable * IEEE is a registered trademark of The Institute of Electrical and Electronics Engineers, Inc. Note: Advisories are issued as needed to update product information. When using this data sheet for design purposes, please contact your Lucent Technologies Microelectronics Group Account Manager to obtain the latest advisory on this product. LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 Table of Contents Contents Page Introduction................................................................................................................................................................ 1 Configuration........................................................................................................................................................... 1 Features .................................................................................................................................................................... 1 10 Mbits/s Transceiver ............................................................................................................................................ 1 100 Mbits/s TX Transceiver ..................................................................................................................................... 1 100 Mbits/s FX Transceiver ..................................................................................................................................... 1 General ................................................................................................................................................................... 4 Description ................................................................................................................................................................ 4 Bused MII Mode...................................................................................................................................................... 4 Clocking .................................................................................................................................................................. 5 FX Mode .................................................................................................................................................................6 Functional Block Diagrams ..................................................................................................................................... 7 Application Diagrams .............................................................................................................................................. 9 Block Diagrams .....................................................................................................................................................11 Pin Information ........................................................................................................................................................13 Pin Diagram for Normal MII Mode.........................................................................................................................13 Pin Diagram for Bused MII Mode ..........................................................................................................................14 Pin Maps ...............................................................................................................................................................15 Pin Descriptions ....................................................................................................................................................16 MII Station Management .........................................................................................................................................29 Basic Operations...................................................................................................................................................29 MII Management Frames ......................................................................................................................................29 Management Registers (MR) ................................................................................................................................30 Unmanaged Operations ........................................................................................................................................40 Mode Select ..........................................................................................................................................................40 Absolute Maximum Ratings (TA = 25 °C) ................................................................................................................41 Electrical Characteristics .........................................................................................................................................41 Timing Characteristics (Preliminary) .......................................................................................................................42 Outline Diagram.......................................................................................................................................................51 208-Pin SQFP.......................................................................................................................................................51 Ordering Information................................................................................................................................................52 Tables Page Table 1. LU3X54FTL Crystal Specifications ............................................................................................................ 6 Table 2. LU3X54FTL Pin Maps.............................................................................................................................. 15 Table 3. MII/Serial Interface Pins in Normal MII Mode (Four Separate MII Ports) ................................................. 16 Table 4. MII/Serial Interface Pins in Bused MII Mode ............................................................................................ 18 Table 5. MII Management Pins .............................................................................................................................. 22 Table 6. 10/100 Mbits/s Twisted-Pair (TP) Interface Pins....................................................................................... 22 Table 7. Miscellaneous Pins .................................................................................................................................. 23 Table 8. MII Management Frame Format............................................................................................................... 29 Table 9. MII Management Frames Field Descriptions............................................................................................ 29 Table 10. MII Management Registers (MR) ........................................................................................................... 30 Table 11. MR0—Control Register Bit Descriptions ................................................................................................ 31 Table 12. MR1—Status Register Bit Descriptions ................................................................................................. 32 Table 13. MR2, 3—PHY Identifier Registers (1 and 2) Bit Descriptions ................................................................ 33 Table 14. MR4—Autonegotiation Advertisement Register Bit Descriptions........................................................... 33 Table 15. MR5—Autonegotiation Link Partner (LP) Ability Register (Base Page) Bit Descriptions ....................... 34 Table 16. MR5—Autonegotiation Link Partner (LP) Ability Register (Next Page) Bit Descriptions ........................ 34 2 Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Table of Contents (continued) Tables Page Table 17. MR6—Autonegotiation Expansion Register Bit Descriptions..................................................................35 Table 18. MR7—Next-Page Transmit Register Bit Descriptions .............................................................................35 Table 19. MR28—Device-Specific Register 1 (Status Register) Bit Descriptions...................................................36 Table 20. MR29—Device-Specific Register 2 (100 Mbits/s Control) Bit Descriptions ............................................37 Table 21. MR30—Device-Specific Register 3 (10 Mbits/s Control) Bit Descriptions ..............................................38 Table 22. MR31—Device-Specific Register 4 (Quick Status) Bit Descriptions.......................................................39 Table 23. Output Pins .............................................................................................................................................40 Table 24. LU3X54FTL Modes.................................................................................................................................40 Table 25. Absolute Maximum Ratings ....................................................................................................................41 Table 26. Operating Conditions ..............................................................................................................................41 Table 27. dc Characteristics ...................................................................................................................................41 Table 28. MII Management Interface Timing (25 pF Load).....................................................................................42 Table 29. MII Data Timing (25 pF Load) .................................................................................................................43 Table 30. Serial 10 Mbits/s Timing for TPIN, CRS, and RX_CLK...........................................................................45 Table 31. Serial 10 Mbits/s Timing for TX_EN, TPOUT, CRS, and RX_CLK..........................................................45 Table 32. Serial 10 Mbits/s Timing for TX_EN, TPIN, and COL .............................................................................46 Table 33. Serial 10 Mbits/s Timing for RX_CLK, CRS, RXD, TX_CLK, TX_EN, and TXD (25 pF Load)................47 Table 34. Serial 10 Mbits/s Timing for RX_CLK and TX_CLK (25 pF Load) ..........................................................48 Table 35. 100 Mbits/s MII Transmit Timing .............................................................................................................49 Table 36. 100 Mbits/s MII Receive Timing..............................................................................................................50 Figures Page Figure 1. LU3X54FTL Device Overview...................................................................................................................7 Figure 2. LU3X54FTL Single-Channel Detail Functions ..........................................................................................8 Figure 3. Typical Single-Channel Twisted-Pair (TP) Interface ..................................................................................9 Figure 4. Typical Single-Channel Fiber-Optic Interface ..........................................................................................10 Figure 5. Smart 10/100 Mbits/s Bused MII Mode...................................................................................................11 Figure 6. Separate 10/100 Mbits/s Bused MII Mode ..............................................................................................12 Figure 7. LU3X54FTL Pinout for Normal MII Mode................................................................................................13 Figure 8. LU3X54FTL Pinout for Bused MII Mode .................................................................................................14 Figure 9. MDIO Input Timing..................................................................................................................................42 Figure 10. MDIO Output Timing .............................................................................................................................42 Figure 11. MDIO During TA (Turnaround) of a Read Transaction ..........................................................................43 Figure 12. MII Timing Requirements for LU3X54FTL ............................................................................................44 Figure 13. Serial 10 Mbits/s Timing for TPIN, CRS, and RX_CLK.........................................................................45 Figure 14. Serial 10 Mbits/s Timing for TX_EN, TPOUT, CRS, and RX_CLK........................................................45 Figure 15. Serial 10 Mbits/s Timing for TX_EN, TPIN, and COL ...........................................................................46 Figure 16. Serial 10 Mbits/s Timing for RX_CLK, CRS, RXD, TX_CLK, TX_EN, and TXD ...................................47 Figure 17. Serial 10 Mbits/s Timing Diagram for RX_CLK and TX_CLK ...............................................................48 Figure 18. 100 Mbits/s MII Transmit Timing ...........................................................................................................49 Figure 19. 100 Mbits/s MII Receive Timing ............................................................................................................50 Lucent Technologies Inc. 3 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 Features (continued) ■ Reuses existing twisted-pair I/O pins for compatible fiber-optic transceiver pseudo-ECL (PECL) data: — No additional data pins required — Reuses existing LU3X54FTL pins for fiber-optic signal detect (FOSD) inputs ■ Fiber mode automatically configures port: — Disables autonegotiation — Disables 10Base-T — Enables 100Base-FX remote fault signaling — Disables MLT-3 encoder/decoder — Disables scrambler/descrambler ■ FX mode enable is pin- or register-selectable on an individual per-port basis — 10 Mbits/s repeater reference select — Internal 20 MHz clock synthesizer — FX mode select ■ Single 25 MHz crystal input or 25 MHz clock input, optional 20 MHz clock input ■ Supports half- and full-duplex operations ■ Provides six status signals: — Receive activity — Transmit activity — Full duplex — Collision/jabber — Link integrity — Speed indication ■ Optional LED pulse stretching ■ Per-channel powerdown mode for 10 Mbits/s and 100 Mbits/s operation ■ Loopback for 10 Mbits/s and 100 Mbits/s operation ■ Internal pull-up or pull-down resistors to set default powerup mode General ■ Autonegotiation (IEEE 802.3u, clause 28): — Fast link pulse (FLP) burst generator — Arbitration function ■ Bused interfaces: — Supports either separate 10 Mbits/s and 100 Mbits/s multiport repeaters (100 Mbits/s MII and 10 Mbits/s serial data stream), or singlechip multispeed repeaters — Connects ports to either the 10 Mbits/s or 100 Mbits/s buses controlled by autonegotiation — Separate TX_EN, RX_EN, CRS, and COL pins for each port — Drivers on bused signal can drive up to eight LU3X54FTLs (32 ports) ■ ■ 4 Supports the station management protocol and frame format (clause 22): — Basic and extended registers — Supports next-page function — Operates up to 12.5 MHz — Accepts preamble suppression — Maskable status interrupts Supports the following management functions via pins if MII station management is unavailable: — Speed select — Carrier integrity enable — Encoder/decoder bypass — Scrambler/descrambler bypass — Full duplex — No link pulse mode — Carrier sense select — Autonegotiation ■ 0.35 µm low-power CMOS technology ■ 208-pin SQFP Description Bused MII Mode The LU3X54FTL has been designed for operation in two basic system interface modes of operation: ■ Normal MII Mode (Four Separate MII Ports). The separate mode provides four independent RJ-45 to MII ports and is similar to having four independent 10/100 transceivers. ■ Bused MII Mode. This mode is designed specifically for repeater applications to save pins. In bused mode: — Data from all of the ports operating at 100 Mbits/s will be internally bused to system interface port A (100 Mbits/s MII interface). — Data from all of the ports operating at 10 Mbits/s will be internally bused to system interface port B (7-pin 10 Mbits/s serial interface). The LU3X54FTL will automatically detect the speed of each port (10 Mbits/s or 100 Mbits/s) and route the data to the appropriate port. Lucent Technologies Inc. Data Sheet July 2000 Description (continued) The bused mode has two additional submodes of operation: ■ Separate Bused MII Mode. This mode is designed to operate with two independent repeater ICs, one repeater operating at 100 Mbits/s and the other operating at 10 Mbits/s. The bused interface allows each of the four transceivers to be connected to one of two system interfaces: ■ Port A: 100 Mbits/s MII interface. ■ Port B: 7-pin 10 Mbits/s serial interface. This configuration allows 10/100 Mbits/s segment segregation or port switching with conventional multiport shared-media repeaters. Figure 6 shows a block diagram of this mode in which separate pins (four of each) are used for COL_10(4), COL_100(4), CRS_10(4), CRS_100(4), RX_EN10(4), RX_EN100(4), TX_EN10 (4), and TX_EN100(4). The port speed configuration and connection to the appropriate bused output is done automatically and is controlled by autonegotiation. The signals RX_CLK10, RXD_10, TX_CLK10, and TXD_10 (all from ports A, B, C, and D) are internally bused together and connected to MII port B. Figure 3 shows how the LU3X54FTL single-channel interfaces to the twisted pair (TP). The signals TX_CLK25, TXD_100[3:0], TX_ER, RX_CLK25, RXD_100[3:0], RX_DV, and RX_ER (all from ports A, B, C, D) are internally bused together and connected to MII port A. The repeater ICs will enable the particular port to which it will communicate by enabling the port with TX_EN 10, TX_EN100, RX_EN10, or RX_EN100. ■ LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Smart Bused MII Mode. This mode is used when the LU3X54FTL is communicating with a single (smart) 10/100 Mbits/s repeater IC, and allows the use of the security feature. Figure 5 shows a block diagram of the smart bused mode of operation. In this mode, a common set of pins is used for CRS_10/100[D:A], RX_EN10/100[D:A], TX_EN10/100, and COL_10/100. Figure 1 gives a functional overview of the LU3X54FTL while Figure 2 details its single-channel functions. Clocking The LU3X54FTL requires an internal 25 MHz clock and a 20 MHz clock to run the 100Base-TX transceiver and 10Base-T transceiver. These clocks can be supplied as follows: ■ As separate clock inputs: 25 MHz and 20 MHz. ■ The 20 MHz clock can be internally synthesized from the 25 MHz clock. ■ The 25 MHz clock can also be internally generated by an on-chip oscillator if an external crystal is supplied. The LU3X54FTL will automatically detect if a 25 MHz clock is supplied, or if a crystal is being used to generate the 25 MHz clock. The 10 Mbits/s (7-pin 10 Mbits/s serial interface) signals are still routed to port B (RX_CLK10, RXD_10, TX_CLK10, and TXD_10). The 100 Mbits/s signals are still routed to port A (TX_CLK25, TXD_100[3:0], TX_ER, RX_CLK25, RXD_100[3:0], RX_DV, and RX_ER). Lucent Technologies Inc. 5 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 Description (continued) FX Mode Either the on-chip 20 MHz clock synthesizer (default clock) can be used, or H-DUPLED[A]/CLK20_SEL (pin 198) can be pulled high (sensed on powerup and reset) to select the external 20 MHz clock input. Each individual port of the LU3X54FTL can be operated in 100Base-FX mode by selecting it through the pin program option RXLED[D:A]/FX_MODE_EN[D:A], or through the register bit (register 29, bit 0). The crystal specifications for the device are listed in Table 1, and the crystal circuit is shown in Figure 3 and Figure 4. When operating in FX mode, the twisted-pair I/O pins are reused as the fiber-optic transceiver I/O data pins, and the fiber-optic signal detect (FOSD) inputs are enabled. Table 1. LU3X54FTL Crystal Specifications Figure 4 shows a typical FX port interface. Note that no additional external components, excluding those needed by the fiber transceiver, are required. Parameter Type Frequency Stability Shunt Capacitor Load Capacitor Series Resistance 6 Requirement Quartz Fundamental Mode 25 MHz ±25 ppm, 0—70 °C 7 pF 20 pF <30 Ω When a port is placed in FX mode, it will automatically configure the port for 100Base-FX operation (and the register bit control will be ignored) such that: ■ The far-end fault signaling option will be enabled. ■ The MLT-3 encoding/decoding will be disabled. ■ Scrambler/descrambler will be disabled. ■ Autonegotiation will be disabled. ■ The signal detect inputs will be activated. ■ 10Base-T will be disabled. Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Description (continued) Functional Block Diagrams Device Overview FX_MODE_EN MANAGEMENT MII/SERIAL INTERFACE PMA PCS AUTONEGOTIATION 10 Mbits/s TRANSCEIVER DRIVER AND FILTERS MANAGEMENT MII/SERIAL INTERFACE 25 MHz DPLL 10 Mbits/s TRANSCEIVER DRIVER AND FILTERS MUX FX_MODE_EN AUTONEGOTIATION TX PMD/ FX PORT DRIVER AND FILTERS 10 Mbits/s TRANSCEIVER DRIVER AND FILTERS MUX PMA PCS MANAGEMENT PMA PCS 25 MHz LSCLK FX_MODE_EN AUTONEGOTIATION MANAGEMENT MII/SERIAL INTERFACE MUX TX PMD/ FX PORT DRIVER AND FILTERS PMA PCS MII/SERIAL INTERFACE TX PMD/ FX PORT DRIVER AND FILTERS AUTONEGOTIATION TP MAGNETICS INTERFACE FX_MODE_EN TX PMD/ FX PORT DRIVER AND FILTERS 125 MHz 10 Mbits/s TRANSCEIVER DRIVER AND FILTERS 20 MHz 25 MHz CRYSTAL MUX 10 MHz 20 MHz 5-5137(F).fr2 Figure 1. LU3X54FTL Device Overview Lucent Technologies Inc. 7 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 Description (continued) Single-Channel Detail Functions FX_MODE_EN 100 Mbits/s TRANSCEIVER 100 OFF CRS COL RXD[3:0] RX_DV RX_ER/RXD[4] RX_CLK TX_CLK TXD[3:0] TX_EN TX_ER/TXD[4] 4B/5B ENCODER TX STATE MACHINE MII MDC MDIO FAR-END FAULT GEN SD COLLISION SD DETECT PMD TX/ FIBER PORT PDT SCRAMBLER RX STATE MACHINE SD TPOUT± DCRU CAR_STAT CIM FX_MODE_EN CARRIER RXERR_ST DETECT 5B/4B DECODER ALIGNER DESCRAMBLER PMD RX/ FIBER PORT PDR FAR-END FAULT DETECT SD REF10 RX_CLK RXD[0] TX_CLK TX_EN TXD[0] CLK20 MANAGEMENT INTERFACE SERIAL INTERFACE MII INTERFACE TXD[3:0] FOSD TPIN± 10 Mbits/s TRANSCEIVER LC100 LC10 LS10 MII MANAGEMENT LS100 AUTONEGOTIATION AND LINK MONITOR 25 MHz LSCLK DPLL 25 MHZ 125 MHz 20 MHz 25 MHz CRYSTAL 5-5136(F).j Figure 2. LU3X54FTL Single-Channel Detail Functions 8 Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Description (continued) Application Diagrams Single-Channel Twisted-Pair Interface VDDO RJ-45 LU3X54FTL 1:1 TPOUT+ 1 50 Ω 220 Ω 50 Ω TPOUT– 220 Ω 2 3 75 Ω 4 0.01 µF 0.01 µF 5 TPIN+ 6 50 Ω 88 87 25 MHz 33 pF 50 Ω TPIN– 8 75 Ω 1:1 XTALIN XTALOUT 7 33 pF 75 Ω 0.01 µF 0.01 µF 0.01 µF 75 Ω 0.01 µF 5-5433(F).r9 Figure 3. Typical Single-Channel Twisted-Pair (TP) Interface Lucent Technologies Inc. 9 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 Description (continued) Single-Channel Fiber-Optic Interface VDDA 0.01 µF VDDO LU3X54FTL TPOUT+ TD 50 Ω 220 Ω 50 Ω TPOUT– 220 Ω 82 Ω 82 Ω 82 Ω 0.01 µF FOSD SD TPIN+ RD 33 pF 25 MHz XTALIN XTALOUT TPIN– 87 50 Ω TDN 0.01 µF 88 50 Ω RDN 130 Ω 130 Ω 130 Ω 33 pF 5-5433(F).dr2 Figure 4. Typical Single-Channel Fiber-Optic Interface 10 Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Description (continued) Block Diagrams Smart Bused MII Mode RX_CLK10 RX_CLK10 RXD_10 RXD_10 TX_CLK10 TXD_10 10/100 Mbits/s SMART REPEATER TX_CLK10 TXD_10 CRS_10/100 4 RX_EN10/100 TX_EN10/100 4 COL_10/100 4 4 SECURITY10/100 4 TX_CLK25 TXD_100[3:0] TX_ER RX_CLK25 RXD_100[3:0] RX_DV RX_ER MDC MDIO CRS_100 RX_EN100 TX_EN100 COL_100 TX_EN10/SECURITY_10/100 TX_CLK25 LU3X54FTL TXD_100[3:0] TX_ER RX_CLK25 RXD_100[3:0] RX_DV RX_ER MDC MDIO SMART_MODE_SELECT BUSED_MII_MODE 5-5599.gr1 Figure 5. Smart 10/100 Mbits/s Bused MII Mode Lucent Technologies Inc. 11 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 Description (continued) Separate Bused MII Mode RX_CLK10 RX_CLK10 RXD_10 RXD_10 TX_CLK10 TXD_10 10 Mbits/s REPEATER COL_10 CRS_10 TX_CLK10 4 4 RX_EN10 TX_EN10 4 CRS_100 TX_EN100 4 4 4 TX_CLK25 TXD_100[3:0] CRS_10 RX_EN10 TX_EN10 CRS_100 TX_EN100 LU3X54FTL TXD_100[3:0] TX_ER RX_CLK25 RX_CLK25 RXD_100[3:0] RXD_100[3:0] RX_DV RX_DV RX_ER COL_100 4 RX_EN100 4 MDC MANAGEMENT COL_10 TX_CLK25 TX_ER 100 Mbits/s REPEATER TXD_10 MDIO RX_ER COL_100 RX_EN100 MDC MDIO SMART_MODE_SELECT BUSED_MII_MODE 5-5599.ar7 Figure 6. Separate 10/100 Mbits/s Bused MII Mode 12 Lucent Technologies Inc. MASK_STAT_INT NC MODE[4] TXD[0][C] TXD[1][C] VSS TXD[2][C] TXD[3][C] VDD3 TX_ER[C]/TXD[4][C] TX_EN[C] VSS TX_CLK[C] CRS[C] COL[C] RX_DV[C] VDD3 RX_ER[C]/RXD[4][C] RX_CLK[C] RXD[0][C] VSS RXD[1][C] RXD[2][C] RXD[3][C] VDD MII_EN[C] VSS VDDPLL CKREF VSSPLL VDDPD FOSD[A] FOSD[B] VSSPD LSCLK/XTALIN XTALOUT TXD[0][D] TXD[1][D] VSS TXD[2][D] TXD[3][D] VDD TX_ER[D]TXD[4][D] TX_EN[D] VSS TX_CLK[D] CRS[D] COL[D] RX_DV[D] VDD3 RX_ER[D]/RXD[4][D] RX_CLK[D] GNDA FOSD[C] FOSD[D] VDDA TPIN+/FOIN+[D] TPIN–/FOIN–[D] GNDA VDDA TPIN+/FOIN+[C] TPIN–/FOIN–[C] GNDA VDDA BGREF[0] GNDA VDDA TPIN+/FOIN+[B] TPIN–/FOIN–[B] GNDA VDDA TPIN+/FOIN+[A] TPIN–/FOIN–[A] GNDA VDDA GNDA BGREF[1] GNDD CLK20 VDDD GNDAA VDDAA GNDO TPOUT+/FOOUT+[D] TPOUT–/FOOUT–[D] VDDO GNDO TPOUT+/FOOUT+[C] TPOUT–/FOOUT–[C] VDDO GNDM VDDM GNDAP ISET_10 ISET_100 VDDAP GNDO TPOUT+/FOOUT+[B] TPOUT–/FOOUT–[B] VDDO GNDO TPOUT+/FOOUT+[A] TPOUT–/FOOUT–[A] VDDO 208 207 206 205 204 203 202 201 200 199 198 197 196 195 194 193 192 191 190 189 188 187 186 185 184 183 182 181 180 179 178 177 176 175 174 173 172 171 170 169 168 167 166 165 164 163 162 161 160 159 158 157 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 VSS MODE[3] MODE[2] MODE[1] MODE[0] RESET VDD H_DUPLED[D]/FULL_DUP H_DUPLED[C]/SERIAL_SEL H_DUPLED[B]/CRS_SEL H_DUPLED[A]/CLK20_SEL AUTO_EN 3ST_EN VDD SPEEDLED[D]/SPEED SPEEDLED[C]/SMART_MODE_SELECT SPEEDLED[B]/BUSED_MII_MODE SPEEDLED[A]/ISOLATE_MODE LINKLED[D]/PHYADD[2] LINKLED[C]PHYADD[1] LINKLED[B]/PHYADD[0] LINKLED[A]/NO_LP VSS VDDA ATEST[B] ATEST[A] GNDA GNDC VDDC VDDC GNDC VSS COLED[D] COLED[C] COLED[B] COLED[A] VDD RXLED[D]/FX_MODE_EN[D] RXLED[C]/FX_MODE_EN[C] RXLED[B]/FX_MODE_EN[B] RXLED[A]/FX_MODE_EN[A] VDD TXLED[D]/CARIN_EN TXLED[C]/ENC_DEC_BYPASS TXLED[B]/SCRAM_DESC_BYPASS VSS TXLED[A]/REF_SEL MII_EN[B] VDD3 RXD[3][B] RXD[2][B] RXD[1][B] Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Pin Information Pin Diagram for Normal MII Mode Lucent Technologies Inc. LU3X54FTL 156 155 154 153 152 151 150 149 148 147 146 145 144 143 142 141 140 139 138 137 136 135 134 133 132 131 130 129 128 127 126 125 124 123 122 121 120 119 118 117 116 115 114 113 112 111 110 109 108 107 106 105 VSS RXD[0][B] RX_CLK[B] RX_ER[B]/RXD[4][B] VDD3 RX_DV[B] COL[B] CRS[B] TX_CLK[B] VSS TX_EN[B] TX_ER[B]/TXD[4][B] VDD TXD[3][B] TXD[2][B] VSS TXD[1][B] TXD[0][B] MII_EN[A] VDD3 RXD[3][A] RXD[2][A] RXD[1][A] VSS RXD[0][A] RX_CLK[A] RX_ER[A]/RXD[4][A] VDD3 RX_DV[A] COL[A] CRS[A] TX_CLK[A] VSS TX_EN[A] TX_ER[A]/TXD[4][A] VDD3 TXD[3][A] TXD[2][A] VSS TXD[1][A] TXD[0][A] VSS REF10 MDC MDIO VDD MII_EN[D] RXD[3][D] RXD[2][D] RXD[1][D] VSS RXD[0][D] 5-5616(F).cr3 Figure 7. LU3X54FTL Pinout for Normal MII Mode 13 MASK_STAT_INT NC MODE[4] RX_EN10[A] RX_EN10[B] VSS RX_EN10[C] RX_EN10[D] VDD3 NC TX_EN100[C]/TX_EN10/100 VSS NC CRS_100[C]/CRS_10/100[C] COL_100[C]/COL_10/100[C] NC VDD3 NC NC COL_10[A] VSS COL_10[B] COL_10[C] COL_10[D] VDD RX_EN100[C]/RX_EN10/100[C] VSS VDDPLL CKREF VSSPLL VDDPD FOSD[A] FOSD[B] VSSPD LSCLK/XTALIN XTALOUT TX_EN10[A]/SECURITY_10/100 TX_EN10[B]/SECURITY_10/100 VSS TX_EN10[C]/SECURITY_10/100 TX_EN10[D]/SECURITY_10/100 VDD NC TX_EN100[D]/TX_EN10/100 VSS NC CRS_100[D]/CRS_10/100[D] COL_100[D]/COL_10/100[D] NC VDD3 NC NC GNDA FOSD[C] FOSD[D] VDDA TPIN+/FOIN+[D] TPIN–/FOIN–[D] GNDA VDDA TPIN+/FOIN+[C] TPIN–/FOIN–[C] GNDA VDDA BGREF[0] GNDA VDDA TPIN+/FOIN+[B] TPIN–/FOIN–[B] GNDA VDDA TPIN+/FOIN+[A] TPIN–/FOIN–[A] GNDA VDDA GNDA BGREF[1] GNDD CLK20 VDDD GNDAA VDDAA GNDO TPOUT+/FOOUT+[D] TPOUT–/FOOUT–[D] VDDO GNDO TPOUT+/FOOUT+[C] TPOUT–/FOOUT–[C] VDDO GNDM VDDM GNDAP ISET_10 ISET_100 VDDAP GNDO TPOUT+/FOOUT+[B] TPOUT–/FOOUT–[B] VDDO GNDO TPOUT+/FOOUT+[A] TPOUT–/FOOUT–[A] VDDO 14 208 207 206 205 204 203 202 201 200 199 198 197 196 195 194 193 192 191 190 189 188 187 186 185 184 183 182 181 180 179 178 177 176 175 174 173 172 171 170 169 168 167 166 165 164 163 162 161 160 159 158 157 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 VSS MODE[3] MODE[2] MODE[1] MODE[0] RESET VDD H_DUPLED[D]/FULL_DUP H_DUPLED[C]/SERIAL_SEL H_DUPLED[B]/CRS_SEL H_DUPLED[A]/CLK20_SEL AUTO_EN 3ST_EN VDD SPEEDLED[D]/SPEED SPEEDLED[C]/SMART_MODE_SELECT SPEEDLED[B]/BUSED_MII_MODE SPEEDLED[A]/ISOLATE_MODE LINKLED[D]/PHYADD[2] LINKLED[C]PHYADD[1] LINKLED[B]/PHYADD[0] LINKLED[A]/NO_LP VSS VDDA ATEST[B] ATEST[A] GNDA GNDC VDDC VDDC GNDC VSS COLED[D] COLED[C] COLED[B] COLED[A] VDD RXLED[D]/FX_MODE_EN[D] RXLED[C]/FX_MODE_EN[C] RXLED[B]/FX_MODE_EN[B] RXLED[A]/FX_MODE_EN[A] VDD TXLED[D]/CARIN_EN TXLED[C]/ENC_DEC_BYPASS TXLED[B]/SCRAM_DESC_BYPASS VSS TXLED[A]/REF_SEL RX_EN100[B]/RX_EN10/100[B] VDD3 NC NC NC LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX LU3X54FTL Data Sheet July 2000 Pin Information (continued) Pin Diagram for Bused MII Mode 156 155 154 153 152 151 150 149 148 147 146 145 144 143 142 141 140 139 138 137 136 135 134 133 132 131 130 129 128 127 126 125 124 123 122 121 120 119 118 117 116 115 114 113 112 111 110 109 108 107 106 105 VSS RXD_10 RX_CLK10 NC VDD3 NC COL_100[B]/COL_10/100[B] CRS_100[B]/CRS_10/100[B] TX_CLK10 VSS TX_EN100[B]/TX_EN10/100 NC VDD NC NC VSS NC TXD_10 RX_EN100[A]/RX_EN10/100[A] VDD3 RXD_100[3] RXD_100[2] RXD_100[1] VSS RXD_100[0] RX_CLK25 RX_ER VDD3 RX_DV COL_100[A]/COL_10/100[A] CRS_100[A]/CRS_10/100[A] TX_CLK25 VSS TX_EN100[A]/TX_EN10/100 TX_ER VDD3 TXD_100[3] TXD_100[2] VSS TXD_100[1] TXD_100[0] VSS REF10 MDC MDIO VDD RX_EN100[D]/RX_EN10/100[D] CRS_10[D] CRS_10[C] CRS_10[B] VSS CRS_10[A] 5-5616(F).dr2 Figure 8. LU3X54FTL Pinout for Bused MII Mode Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Pin Information (continued) Pin Maps Table 2. LU3X54FTL Pin Maps Normal Mode Pins Bused Mode Pins 10/100 Mbits/s Smart Mode Pins Separate Mode Pins RXD[3:0][D] CRS_10[D:A] Not used CRS_10 CRS[D:A] CRS_100[D:A] CRS_10/100 CRS_100 TXD[3:0][C] RX_EN10/100 Not used RX_EN10 MII_EN[D:A] RX_EN100[D:A] RX_EN10/100 RX_EN100 TXD[3:0][D] TX_EN10[D:A] SECURITY_10/100 TX_EN10 TX_EN[D:A] TX_EN100[D:A] TX_EN10/100 TX_EN100 RXD[3:0][C] COL_10[D:A] Not used COL_10 COL[D:A] COL_100[D:A] COL_10/100 COL_100 SPEEDLED[C] SMART_MODE_SELECT SMART_MODE_SELECT SMART_MODE_SELECT SPEEDLED[B] BUSED_MII_MODE BUSED_MII_MODE BUSED_MII_MODE TX_CLK[A] TX_CLK25 TX_CLK25 TX_CLK25 TX_CLK[B] TX_CLK10 TX_CLK10 TX_CLK10 RX_CLK[B] RX_CLK10 RX_CLK10 RX_CLK10 RX_CLK[A] RX_CLK25 RX_CLK25 RX_CLK25 RXD[0][B] RXD_10 RXD_10 RXD_10 RXD[3:0][A] RXD_100[3:0] RXD_100 RXD_100 RX_DV[A] RX_DV RX_DV RX_DV RX_ER[A] RX_ER RX_ER RX_ER TXD[0][B] TXD_10 TXD_10 TXD_10 TXD[3:0][A] TXD_100[3:0] TXD_100 TXD_100 TX_ER[A]/TXD[4][A] TX_ER TX_ER TX_ER Lucent Technologies Inc. 15 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 Pin Information (continued) Pin Descriptions This section describes the LU3X54FTL signal pins. Note that any register bit referenced includes the register number and bit position. For example, register bit [29.8] is register 29, bit 8. Table 3. MII/Serial Interface Pins in Normal MII Mode (Four Separate MII Ports) 16 Pin Signal Type Description 100 67 150 127 COL[D:A] O 99 66 149 126 CRS[D:A] O 104 71 154 131 109 76 159 136 108 75 158 135 107 74 157 134 105 72 155 132 101 68 151 128 103 70 153 130 RX_CLK[D:A] O RXD[3:0][D:A] O Collision Detect. This signal signifies in half-duplex mode that a collision has occurred on the network. COL is asserted high whenever there is transmit and receive activity on the UTP media. COL is the logical AND of TX_EN and receive activity, and is an asynchronous output. When SERIAL_SEL is high and in 10Base-T mode, this signal indicates the jabber timer has expired. Carrier Sense. When CRS_SEL is low, this signal is asserted high when either the transmit or receive medium is nonidle. This signal remains asserted throughout a collision condition. When CRS_SEL is high, CRS is asserted on receive activity only. CRS_SEL is set via the MII management interface or the CRS_SEL pin. Receive Clock. 25 MHz clock output in 100 Mbits/s mode, 2.5 MHz output in 10 Mbits/s nibble mode, 10 MHz in 10 Mbits/s serial mode. RX_CLK has a worst-case 45/55 duty cycle. RX_CLK provides the timing reference for the transfer of RX_DV, RXD, and RX_ER signals. Receive Data. 4-bit parallel data outputs that are synchronous to RX_CLK. When RX_ER[D:A] is asserted high in 100 Mbits/s mode, an error code will be presented on RXD[3:0][D:A] where appropriate. The codes are as follows: ■ Packet errors: ERROR_CODES = 2h. ■ Link errors: ERROR_CODES = 3h. (Packet and link error codes will only be repeated if registers [29.9] and [29.8] are enabled.) ■ Premature end errors: ERROR_CODES = 4h. ■ Code errors: ERROR_CODES = 5h. When SERIAL_SEL is active-high and 10 Mbits/s mode is selected, RXD[0] is used for data output and RXD[3:1] are 3-stated. RX_DV[D:A] O RX_ER[D:A]/ RXD[4][D:A] O Receive Data Valid. When this pin is high, it indicates the LU3X54FTL is recovering and decoding valid nibbles on RXD[3:0], and the data is synchronous with RX_CLK. RX_DV is synchronous with RX_CLK. This pin is not used in serial 10 Mbits/s mode. Receive Error. When high, RX_ER indicates the LU3X54FTL has detected a coding error in the frame presently being transferred. RX_ER is synchronous with RX_CLK. Receive Data[4]. When encoder/decoder bypass (ENC_DEC_BYPASS) is selected through the MII management interface, this output serves as the RXD[4] output. This pin is only valid when the LU3X54FTL is in 100 Mbits/s mode. Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Pin Information (continued) Table 3. MII/Serial Interface Pins in Normal MII Mode (Four Separate MII Ports) (continued) Pin Signal Type Description 98 65 148 125 93, 60 143, 120 92, 59 142, 119 90, 57 140, 117 89, 56 139, 116 96 63 146 123 95 62 145 122 TX_CLK[D:A] O TXD[3:0][D:A] I Transmit Clock. 25 MHz clock output in 100 Mbits/s mode, 2.5 MHz output in 10 Mbits/s MII mode, 10 MHz output in 10 Mbits/s serial mode. TX_CLK provides timing reference for the transfer of the TX_EN, TXD, and TX_ER signals sampled on the rising edge of TX_CLK. Transmit Data. 4-bit parallel input synchronous with TX_CLK. When SERIAL_SEL is active-high and 10 Mbits/s mode is selected, only TXD[0][D:A] are valid. TX_EN[D:A] I TX_ER[D:A]/ TXD[4][D:A] I MII_EN[D:A] I 110 78 161 138 Lucent Technologies Inc. Transmit Enable. When driven high, this signal indicates there is valid data on TXD[3:0]. TX_EN is synchronous with TX_CLK. When SERIAL_SEL is active-high and 10 Mbits/s mode is selected, this pin indicates there is valid data on TXD[0]. Transmit Coding Error. When driven high, this signal causes the encoder to intentionally corrupt the byte being transmitted across the MII (00100 will be transmitted). Transmit Data[4]. When the encoder/decoder bypass bit is set, this input serves as the TXD[4] input. When in 10 Mbits/s mode and SERIAL_SEL is active-high, this pin is ignored. MII Enable. For normal MII mode of operation (nonbused mode), MII_EN for each channel must be tied high to enable each individual port being used. 17 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 Pin Information (continued) When operating in bused MII mode, 100 Mbits/s data is bused to MII port A, and 10 Mbits/s data is bused to MII port B. Table 4. MII/Serial Interface Pins in Bused MII Mode Pin Signal Type Description 125 TX_CLK25 O 148 TX_CLK10 O Shared Transmit Clock (25 MHz). 25 MHz clock output in 100 Mbits/s mode. TX_CLK25 provides timing reference for the transfer of the TX_EN100, TXD_100, and TX_ER signals that are sampled on the rising edge of TX_CLK25. Shared Transmit Clock (10 MHz). 10 MHz clock output in 10 Mbits/s serial mode. TX_CLK10 provides timing reference for the transfer of the TX_EN10 and TXD_10 signals that are sampled on the rising edge of TX_CLK10. 109 108 107 105 CRS_10[D:A] O 99 66 149 126 CRS_100[D:A]/ CRS_10/100[D:A] O 154 RX_CLK10 O 131 RX_CLK25 O 155 RXD_10 O 18 When operating in 10 Mbits/s bused mode, the REF10 input clock must be used, and the REF_SEL pin must be pulled high through a 4.7 kΩ resistor (TXLED[A] pin). Carrier Sense—10 Mbits/s Mode. When CRS_SEL is low, this signal is asserted high when either the transmit or receive medium is nonidle. This signal remains asserted throughout a collision condition. When CRS_SEL is high, CRS_10 is asserted on receive activity only. CRS_SEL is set via the MII management interface or the CRS_SEL pin. When SMART_MODE_SELECT is asserted, the LU3X54FTL will internally OR together the CRS_10 and the CRS_100 signals and output them on the CRS_100 signals. Carrier Sense—100 Mbits/s Mode. When CRS_SEL is low, this signal is asserted high when either the transmit or receive medium is nonidle. This signal remains asserted throughout a collision condition. When CRS_SEL is high, CRS_100 is asserted on receive activity only. CRS_SEL is set via the MII management interface or the CRS_SEL pin. Carrier Sense—10/100 Mbits/s Smart Mode. When SMART_MODE_SELECT is asserted, the LU3X54FTL will internally OR together the CRS_10 and the CRS_100 signals and output them on the CRS_100 signals. Shared Receive Clock. 10 MHz clock output in 10 Mbits/s serial mode. RX_CLK10 has a worst-case 45/55 duty cycle. RX_CLK10 provides the timing reference for the transfer of RXD_10 when in the 10 Mbits/s mode. This signal is sampled on the rising edge of RX_CLK10. Shared Receive Clock. 25 MHz clock output in the 100 Mbits/s mode. RX_CLK25 has a worst-case 45/55 duty cycle. RX_CLK25 provides the timing reference for the transfer of RX_DV, RXD_100, and RX_ER signals when in the 100 Mbits/s mode. These signals are sampled on the rising edge of RX_CLK100. Shared Receive Data. Serial data output that is synchronous to the falling edge of RX_CLK10. Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Pin Information (continued) When operating in bused MII mode, 100 Mbits/s data is bused to MII port A, and 10 Mbits/s data is bused to MII port B. Table 4. MII/Serial Interface Pins in Bused MII Mode (continued) Pin Signal Type Description 136 135 134 132 RXD_100[3:0] O Shared Receive Data. 4-bit parallel data outputs that are synchronous to the falling edge of RX_CLK25. When RX_ER is asserted high, an error code will be presented on RXD_100[3:0] where appropriate. The codes are as follows: 60 59 57 56 RX_EN10[D:A] I ■ Packet errors, ERROR_CODES = 2h. ■ Link errors, ERROR_CODES = 3h (packet and link error codes will only be repeated if registers [29.9] and [29.8] are enabled). ■ Premature end errors, ERROR_CODES = 4h. ■ Code errors, ERROR_CODES = 5h. Receive Enable—10 Mbits/s Mode. When SMART_MODE_SELECT is not enabled and RX_EN10 is driven high, its channel’s data and clock (RXD0 and RX_CLK) are driven onto the shared serial bus. If the individual channel is not configured for 10 Mbits/s mode, this input will be ignored. When RX_EN10s are all set low, the serial bus will float. Note: Care should be taken that no more than one RX_EN is asserted at a time. 110 78 161 138 RX_EN100[D:A]/ RX_EN10/100[D:A] I 128 RX_DV O 130 RX_ER O 139 120 119 117 116 TXD_10 TXD_100[3:0] I I Lucent Technologies Inc. When SMART_MODE_SELECT is enabled, these pins are ignored. Receive Enable—100 Mbits/s Mode. When SMART_MODE_SELECT is not enabled and RX_EN100 is driven high, its channel’s data, clock, and receive data valid signals (RXD_100, RX_DV, RX_ER, and RX_CLK25) are driven onto the shared MII bus. If the individual channel is not configured for 100 Mbits/s mode, this input will be ignored. When RX_EN100s are all set low, the MII bus will float. Note: Care should be taken that no more than one RX_EN is asserted at a time. Receive Enable—10/100 Mbits/s Smart Mode. When SMART_MODE_SELECT is asserted and RX_EN100 is driven high, its channel’s data, clock, and receive data valid signals [RXD, RX_ER (100 Mbits/s only), RX_DV (100 Mbits/s only), and RX_CLK] are driven onto the shared bus corresponding to the speed of the channel. Shared Receive Data Valid. When this pin is driven high, it indicates that the LU3X54FTL is recovering and decoding valid nibbles on RXD[3:0] and that the data is synchronous with RX_CLK. RX_DV is synchronous with RX_CLK. This pin is not used in serial 10 Mbits/s mode. Shared Receive Error. When asserted high, it indicates that the LU3X54FTL has detected a coding error in the frame presently being transferred. RX_ER is synchronous with RX_CLK25. This signal is not used in 10 Mbits/s mode. Shared Transmit Data. 10 Mbits/s serial input synchronous with TX_CLK10. Shared Transmit Data. 4-bit parallel input synchronous with TX_CLK25. 19 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 Pin Information (continued) When operating in bused MII mode, 100 Mbits/s data is bused to MII port A, and 10 Mbits/s data is bused to MII port B. Table 4. MII/Serial Interface Pins in Bused MII Mode (continued) Pin Signal Type Description 93 92 90 89 TX_EN10/[D:A]/ SECURITY_10/100 I Transmit Enable—10 Mbits/s Mode. When driven high, this signal indicates that there is valid data on TXD when the corresponding channel is in 10 Mbits/s serial mode. Security for 10/100 Mbits/s Smart Mode. When SMART_MODE_SELECT is enabled, these pins are redefined to be the security input pins for both 10 Mbits/s and 100 Mbits/s. When security is activated, the LU3X54FTL will ignore the transmit data, and a fixed pattern is transmitted (all 1s for 10Base-T, alternating 1, 0 for 100TX). 96 63 146 123 TX_EN100[D:A]/ TX_EN10/100 I 122 TX_ER I 76 75 74 72 COL_10[D:A] O 100 67 150 127 20 COL_100[D:A]/ COL_10/100[D:A] O Security should not be asserted until after the entire preamble has been transmitted. When in smart mode, the 10 Mbits/s transmit channels will be enabled through the TX_EN100 inputs. Transmit Enable—100 Mbits/s Mode. When SMART_MODE_SELECT is not enabled and TX_EN100 is driven high, this signal indicates that there is valid data on TXD_100[3:0] when in 100 Mbits/s mode. If the individual channel is not configured for 100 Mbits/s mode, this input will be ignored. Transmit Enable—10/100 Mbits/s Smart Mode. When SMART_MODE_SELECT is asserted and TX_EN100 is driven high, this signal indicates that its channel’s input data is valid. The input data is selected by the speed of the corresponding channel. Shared Transmit Coding Error. When asserted high, this signal causes the encoder to intentionally corrupt the byte being transmitted across the MII (00100 will be transmitted). This signal is not used in 10 Mbits/s mode. Collision Detect for 10 Mbits/s Mode. In half-duplex mode, this signal signifies that a collision has occurred on the network. COL_10 is asserted high whenever there is transmit and receive activity on the UTP media. COL_10 is the logical AND of TX_EN and receive activity, and it is an asynchronous output. When SERIAL_SEL is high and in 10Base-T mode, this signal indicates that the jabber timer has expired. When SMART_MODE_SELECT is asserted, the LU3X54FTL will internally OR together the COL_10 and COL_100 signals and output them on the COL_100 pins. Collision Detect for 100 Mbits/s Mode. In half-duplex mode, this signal signifies that a collision has occurred on the network. COL_100 is asserted high whenever there is transmit and receive activity on the UTP media. COL_100 is the logical AND of TX_EN and receive activity, and it is an asynchronous output. Collision Detect for 10/100 Mbits/s Smart Mode. When SERIAL_SEL is high and in 10Base-T mode, this signal indicates that the jabber timer has expired. When SMART_MODE_SELECT is asserted, the LU3X54FTL will internally OR together the COL_10 and COL_100 signals and output them on the COL_100 pins. Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Pin Information (continued) When operating in bused MII mode, 100 Mbits/s data is bused to MII port A, and 10 Mbits/s data is bused to MII port B. Table 4. MII/Serial Interface Pins in Bused MII Mode (continued) Pin Signal Type 65 68 70 71 98 101 103 104 62 95 140 142 143 145 151 153 157 158 159 NC O No Connect. Do not connect these pins. NC I No Connect. These inputs should be grounded. Lucent Technologies Inc. Description 21 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 Pin Information (continued) Table 5. MII Management Pins Pin Signal Type Description 113 MDC I Management Data Clock. This is the timing reference for the transfer of data on the MDIO signal. This signal may be asynchronous to RX_CLK and TX_CLK. The maximum clock rate is 12.5 MHz. 112 MDIO I/O 53 MASK_STAT_INT O When running MDC above 6.25 MHz, MDC must be synchronous with LSCLK and have a setup time of 15 ns and a hold time of 5 ns with respect to LSCLK. When using an external crystal instead of an LSCLK input, the maximum MDC rate is 6.25 MHz. Management Data Input/Output. This I/O is used to transfer control and status information between the LU3X54FTL and the station management. Control information is driven by the station management synchronous with MDC. Status information is driven by the LU3X54FTL synchronous with MDC. This pin requires an external 1.5 kΩ pull-up resistor. Maskable Status Interrupt. This pin will go high whenever there is a change in status as defined in Table 22. Table 6. 10/100 Mbits/s Twisted-Pair (TP) Interface Pins Pin Signal Type Description 5 9 16 20 TPIN+/ FOIN+[D:A] I Received Data. Positive differential received 125 Mbaud MLT3, or 10 Mbaud Manchester data from magnetics. 6 10 17 21 TPIN–/ FOIN–[D:A] 32 36 46 50 TPOUT+/ FOOUT+[D:A] 33 37 47 51 TPOUT–/ FOOUT–[D:A] 3 2 85 84 FOSD[D:A] 22 Fiber-Optic Data Input. Positive differential received 125 Mbaud pseudoECL data from fiber transceiver. I Received Data. Negative differential received 125 Mbaud MLT3 or 10 Mbaud Manchester data from magnetics. Fiber-Optic Data Input. Negative differential received 125 Mbaud pseudoECL data from fiber transceiver. O Transmit Data. Positive differential transmit 125 Mbaud MLT3 or 10 Mbaud Manchester data to magnetics. Fiber-Optic Data Output. Positive differential transmit 125 Mbaud pseudoECL compatible data to fiber transceiver. O Transmit Data. Negative differential transmit 125 Mbaud MLT3 or 10 Mbaud Manchester data to magnetics. Fiber-Optic Data Output. Negative differential transmit 125 Mbaud pseudoECL compatible data to fiber transceiver. I Fiber-Optic Signal Detect. Pseudo-ECL input signal which indicates whether or not the fiber-optic receive pairs (FOIN±) are receiving valid signal levels. These inputs are ignored when not in fiber mode, and should be grounded. Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Pin Information (continued) Table 7. Miscellaneous Pins Pin Signal Type 81 CKREF I 184 183 197 ATEST[B:A] O AUTO_EN I 1, 7, 11, 14, 18, 22, 24, 26, 29, 31, 35, 39, 41, 45, 49, 58, 64, 73, 79, 82, 86, 91, 97, 106, 115, 118, 124, 133, 141, 147, 156, 163, 177, 178, 181, 182, 186, 208 4, 8, 12, 15, 19, 23, 28, 30, 34, 38, 40, 44, 48, 52, 77, 80, 83, 94, 111, 144, 167, 172, 179, 180, 185, 195, 202 61, 69, 102, 121, 129, 137, 152, 160 196 GND/VSS 3ST_EN I 25 13 42 BGREF[1:0] I ISET_10 I Description Clock Reference. Connect this pin to a 1 nF ± 10% capacitor to ground. Reserved. For normal operation, leave these pins unconnected. Autonegotiation Enable. When this pin is high, autonegotiation is enabled. Pulsing this pin will cause autonegotiation to restart. This input has the same function as register 0, bit 12. This input and the register bit are ANDed together. PWR Ground. (38 pins.) VDD PWR VDD. 5.0 V ± 5% power supply (27 pins.) VDD3 PWR VDD3. 3.3 V ± 5% or 5.0 V ± 5% power supply (8 pins.) Lucent Technologies Inc. 3-State Enable. When this pin is high, all digital outputs will be 3-stated. For normal operating conditions, pull this pin low. Band Gap Reference. Connect these pins to a 24.9 kΩ ± 1% resistor to ground. The parasitic load capacitance should be less than 15 pF. Current Set 10 Mbits/s. An external resistor (22.1 kΩ) is placed from this pin to ground to set the 10 Mbits/s TP driver transmit output level. 23 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 Pin Information (continued) Table 7. Miscellaneous Pins (continued) Pin Signal Type Description 43 ISET_100 I 114 REF10 I 27 CLK20 I 166 TXLED[D]/ CARIN_EN I/O Current Set 100 Mbits/s. An external resistor (nominally 24.9 kΩ) is placed from this pin to ground to set the 100 Mbits/s TP driver transmit output level. 10 MHz Input Clock. Optional reference clock for 10 Mbits/s repeater mode for phase alignment. When used, TX_CLK will be driven from REF10. If not used, let this pin float. 20 MHz Input Clock. 20 MHz (±100 ppm) TTL level clock with 45%—55% duty cycle. If the internal 20 MHz clock synthesizer is being used, ground this pin (default). Transmit LED[D]. This pin indicates transmit activity on port D. External buffers are necessary to drive the LEDs. Carrier Integrity Enable. At powerup or reset, if this pin is pulled high through a 4.7 kΩ resistor, it will enable the carrier integrity function of register 29, bit 3, if station management is unavailable. 165 164 162 TXLED[C]/ ENC_DEC_BYPASS TXLED[B]/ SCRAM_DESC_BYPASS TXLED[A]/ REF_SEL I/O I/O I/O This pin has an internal 50 kΩ pull-down resistor for normal operation (CARIN_EN is disabled). This input and register bits [29.3] are ORed together. Transmit LED[C]. This pin indicates transmit activity on port C. External buffers are necessary to drive the LEDs. Encoder/Decoder Bypass. At powerup or reset, if this pin is pulled high through a 4.7 kΩ resistor, it will enable the ENC_DEC_BYPASS function of register 29, bit 6, if station management is unavailable. This pin has an internal 50 kΩ pull-down resistor for normal operation (encoder/decoder ON). This input and the register bit [29.6] are ORed together enabling the encoder/decoder bypass function for all four channels. Transmit LED[B]. This pin indicates transmit activity on port B. External buffers are necessary to drive the LEDs. Scrambler/Descrambler Bypass. At powerup or reset, this pin may be used to enable the SCRAM_DESC_BYPASS function by pulling this pin high through a 4.7 kΩ resistor, if station management is unavailable. This is the same function as register 29, bit 4. This pin has an internal 50 kΩ pull-down resistor for normal operation (scrambler/descrambler ON). This input and the register bit [29.4] are ORed together during powerup and reset. Transmit LED[A]. This pin indicates transmit activity on port A. External buffers are necessary to drive the LEDs. Reference Select. At powerup, this pin may be used to select the 10 MHz reference input of pin REF10 by pulling it high through a 4.7 kΩ resistor, if station management is unavailable. This is the same function as register 30, bit 2. This pin has an internal 50 kΩ pull-down resistor for normal operation (REF10 not used). This input and the register bit are ORed together. 24 Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Pin Information (continued) Table 7. Miscellaneous Pins (continued) Pin Signal Type Description 171—168 RXLED[D:A]/ FX_MODE_EN[D:A] I/O Receive LED[D:A]. This pin indicates receive activity. External buffers are necessary to drive the LEDs. FX Mode Enable. At powerup or reset, when pulled high through a 4.7 kΩ resistor, this pin will enable the FX mode (10Base-T and 100Base-TX disabled). When pulled low, it will enable 10Base-T and 100Base_TX modes (100Base-FX mode disabled). These pins are ORed with register 29, bit 0 [29.0]. 176—173 COLED[D:A] O These pins have internal 50 kΩ pull-down resistors. Collision LED. This pin indicates collision occurrence. External buffers are necessary to drive the LEDs. I/O Channels A and B have internal 50 kΩ pull-down resistors but not channels C and D. Link LED[D]. This pin indicates good link status on port D. External buffers are necessary to drive the LEDs. PHY Address 2. At powerup or reset, this pin is used to set the PHY address bit 2. I/O If this pin is pulled high through a 50 kΩ resistor, it will set PHYADD[2] to a 1. If this pin is pulled low through a 50 kΩ resistor, it will set PHYADD[2] to a 0. Link LED[C]. This pin indicates good link status on port C. External buffers are necessary to drive the LEDs. PHY Address 1. At powerup or reset, this pin is used to set the PHY address bit 1. I/O If this pin is pulled high through a 50 kΩ resistor, it will set PHYADD[1] to a 1. If this pin is pulled low through a 50 kΩ resistor, it will set PHYADD[1] to a 0. Link LED[B]. This pin indicates good link status on port B. External buffers are necessary to drive the LEDs. PHY Address 0. At powerup or reset, this pin may be used to set the PHY address bit 0. 190 189 188 187 LINKLED[D]/ PHYADD[2] LINKLED[C]/ PHYADD[1] LINKLED[B]/ PHYADD[0] LINKLED[A]/ NO_LP I/O If this pin is pulled high through a 50 kΩ resistor, it will set PHYADD[0] to a 1. If this pin is pulled low through a 50 kΩ resistor, it will set PHYADD[0] to a 0. Link LED[A]. This pin indicates good link status on port A. External buffers are necessary to drive the LEDs. No Link Pulse. This pin is used at powerup or reset to select the NO_LP function of register 30, bit 0 for all four channels by pulling this pin high through a 4.7 kΩ resistor. This input and the register bit [30.0] are ORed together. This pin has an internal 50 kΩ pull-down resistor to set the default to normal link pulse ON mode. Lucent Technologies Inc. 25 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 Pin Information (continued) Table 7. Miscellaneous Pins (continued) Pin Signal Type Description 194 SPEEDLED[D]/ SPEED I/O Speed LED[D]. This pin indicates the operating speed of port D on the LU3X54FTL. A high on this pin indicates 100 Mbits/s operation. A low indicates 10 Mbits/s operation. External buffers are necessary to drive the LEDs. Speed. This pin is used at powerup or reset to select the operating speed on all four channels and is the same function as register 0, bit 13: 193 SPEEDLED[C]/ SMART_MODE_SELECT I/O ■ This pin is internally pulled high through a 100 kΩ resistor to enable 100 Mbits/s operation (defaults to 100 Mbits/s). ■ If this pin is pulled low through a 4.7 kΩ resistor, it will enable 10 Mbits/s operation. This pin is ignored when autonegotiation is enabled. This pin and the register bit are ANDed. Speed LED[C]. This pin indicates the operating speed of port C on the LU3X54FTL. A high on this pin indicates 100 Mbits/s operation. A low indicates 10 Mbits/s operation. External buffers are necessary to drive the LEDs. Smart Mode Select. At powerup or reset, if this pin is pulled high through a 4.7 kΩ resistor, the smart mode will be selected which enables the use of the security feature and redefines the CRS, COL, and TX_EN10 pins. This pin is internally pulled low through a 50 kΩ pull-down resistor. The default value is SMART_MODE _SELECT disabled. When SMART_MODE_SELECT is asserted, the TX_EN10 inputs are used as the security inputs for both 10 Mbits/s mode and 100 Mbits/s mode. When security is activated high, the LU3X54FTL will transmit a jam signal instead of data. 192 SPEEDLED[B]/ BUSED_MII_MODE I/O When SMART_MODE_SELECT is asserted high, both the CRS_10 and CRS_100 signals will be output on the CRS_100 pins, and both the COL_10 and COL_100 signals will be output on the COL_100 pins. Speed LED[B]. This pin indicates the operating speed of port B on the LU3X54FTL. A high on this pin indicates 100 Mbits/s operation. A low indicates 10 Mbits/s operation. External buffers are necessary to drive the LEDs. Bused MII Mode Select. At powerup or reset, if the bused MII mode select pin is pulled high through a 4.7 kΩ resistor, data streams from ports running at 100 Mbits/s will appear on the single 100 Mbits/s MII (port A), and data streams from ports running at 10 Mbits/s will appear at the single 10 Mbits/s serial interface (port B). In addition, control signals TX_EN10, TX_EN100, RX_EN10, RX_EN100, CRS_10, and CRS_100 become active. This pin is internally pulled low through a 50 kΩ pull-down resistor. The default value is bused mode disabled. 26 Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Pin Information (continued) Table 7. Miscellaneous Pins (continued) Pin Signal Type Description 191 SPEEDLED[A]/ ISOLATE_MODE I/O Speed LED[A]. This pin indicates the operating speed of port A on the LU3X54FTL. A high on this pin indicates 100 Mbits/s operation. A low indicates 10 Mbits/s operation. External buffers are necessary to drive the LEDs. Isolate Mode. As an input, this pin can be used at powerup or reset to select the isolate operation mode. If this pin is pulled high through a 4.7 kΩ resistor, the LU3X54FTL will powerup or reset to the isolate mode. (MII outputs to high-impedance state.) 201 H_DUPLED[D]/ FULL_DUP I/O 198 H_DUPLED[A]/ CLK20_SEL I/O 87 LSCLK/XTALIN I 88 XTALOUT I 55 207—204 MODE[4:0] I Lucent Technologies Inc. This pin is internally pulled low through a 50 kΩ resistor. The default state is for the LU3X54FTL to powerup or reset in a nonisolate mode. This pin and register bit [10.0] are ORed together during powerup and reset. Half-Duplex LED[D]. When this output is high, it indicates half-duplex mode. When it is low, it indicates full duplex. External buffers are necessary to drive the LEDs. This output is only valid when the link is up. Full Duplex. At powerup, this pin may be used to select full-duplex operation for all four channels by pulling it high through a 4.7 kΩ resistor, if station management is unavailable. This is the same function as register 0, bit 8. This pin has an internal 50 kΩ pull-down resistor to default to half duplex for normal operation. This input and the register bit [0.8] are ORed together during powerup and reset. Half-Duplex LED[A]. When this output is high, it indicates half-duplex mode. When low, it indicates full duplex. External buffers are necessary to drive the LEDs. This output is only valid when the link is up. 20 MHz Clock Select. When this signal is pulled high through a 4.7 kΩ resistor, it will enable the two-clock input mode (20 MHz and 25 MHz). This pin is internally pulled low through a 50 kΩ resistor to set the default to internal 20 MHz. When low, this signal enables the singleclock input mode (25 MHz with 20 MHz clock internally generated). This pin has the same function as register 30, bit 6, if station management is unavailable. This input and the register bit [30.6] are ORed together during powerup and reset. CMOS Local Symbol Clock. A 25 MHz clock, ±100 ppm, 40%—60% duty cycle. Crystal Oscillator Input. A 25 MHz crystal ±25 ppm can be connected across XTALIN and XTALOUT. Crystal Oscillator Output. A 25 MHz crystal ±25 ppm can be connected across XTALIN and XTALOUT. If a single-ended external clock (LSCLK) is connected to XTALIN, the crystal output pin should be left floating. Test Mode Select. Reserved for manufacturing testing. These pins should be tied low for normal operation. 27 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 Pin Information (continued) Table 7. Miscellaneous Pins (continued) Pin Signal Type Description 203 RESET I 199 H_DUPLED[B]/ CRS_SEL I/O Full Chip Reset. Reset must be asserted high for at least five LSCLK cycles. The LU3X54FTL will come out of reset after 400 µs. LSCLK must remain running during reset. Half-Duplex LED[B]. When this output is high, it indicates half-duplex mode. When it is low, it indicates full duplex. External buffers are necessary to drive the LEDs. This output is only valid when the link is up. Carrier Sense Select. At powerup, this pin may be used to select the mode of CRS operation. When this pin is pulled high through a 4.7 kΩ resistor, CRS will be asserted on receive activity only. This is the same function as register 29, bit 10. 200 54 28 H_DUPLED[C]/ SERIAL_SEL NC I/O — This pin has an internal 50 kΩ pull-down resistor for normal mode operation (default: CRS asserted on transmit or receive activity). This input and the register bit [29.10] are ORed together during powerup and reset. Half-Duplex LED[C]. When this output is high, it indicates half-duplex mode. When low, it indicates full duplex. External buffers are necessary to drive the LEDs. This output is only valid when the link is up. Serial Select. At powerup, this pin may be used to set the SERIAL_SEL function of register 30, bit 1 for all four channels by pulling it high through a 4.7 kΩ resistor if station management is unavailable. This pin has an internal 50 kΩ pull-down resistor for normal mode operation (default). This input and the register bit [30.1] are ORed together during powerup and reset. No Connect. Do not connect these pins. Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX MII Station Management Basic Operations The primary function of station management is to transfer control and status information about the LU3X54FTL to a management entity. This function is accomplished by the MDC clock input, which has a maximum frequency of 12.5 MHz, along with the MDIO pin. This pin (112) requires an external 1.5 kΩ pull-up resistor. The management interface (MII) uses MDC and MDIO to physically transport information between the PHY and the station management entity. A specific set of registers and their contents (described in Table 8) defines the nature of the information transferred across this interface. Frames transmitted on the MII management interface will have the frame structure shown in Table 8. The order of bit transmission is from left to right. Note that reading and writing of the management register must be completed without interruption. Since the LU3X54FTL is a four-channel device, each of the management registers is duplicated four times as depicted in the functional block diagram shown in Figure 1. To select a particular channel [D:A], write to that channel’s unique PHY address as described in Table 9. MII Management Frames The fields and format for management frames are described in the following tables. Table 8. MII Management Frame Format Read/Write (R/W) Pre ST OP PHYADD REGAD TA DATA Idle R W 1...1 1...1 01 01 10 01 AAAAA AAAAA RRRRR RRRRR Z0 10 DDDDDDDDDDDDDDDD DDDDDDDDDDDDDDDD Z Z Table 9. MII Management Frames Field Descriptions Field Description Pre Preamble. The preamble is a series of 32 ones. The LU3X54FTL will accept frames with no preamble. This is indicated by a 1 in register 1, bit 6. Start of Frame. The start of frame is indicated by a 01 pattern. Operation Code. The operation code for a read transaction is 10. The operation code for a write transaction is 01. PHY Address. The PHY address is 5 bits, allowing for 32 unique addresses. The first PHY address bit transmitted and received is the MSB of the address. A station management entity, which is attached to multiple PHY entities, must have prior knowledge of the appropriate PHY address for each entity. The address 00000 is the broadcast address. This address will produce a match regardless of the local address. ST OP PHYADD The LU3X54FTL maps the PHYADD[2:0] to the most significant 3 bits, while the least significant 2 bits address the channel within the LU3X54FTL as follows: REGAD TA DATA 00: Channel A. 01: Channel B. 10: Channel C. 11: Channel D. Register Address. The register address is 5 bits, allowing for 32 unique registers within each PHY. The first register address bit transmitted and received is the MSB of the address. Turnaround. The turnaround time is a 2-bit time spacing between the register address field and the data field of a frame to avoid drive contention on MDIO during a read transaction. During a write to the LU3X54FTL, these bits are driven to a 10 by the station. During a read, the MDIO is not driven during the first bit time and is driven to a 0 by the LU3X54FTL during the second bit time. Data. The data field is 16 bits. The first bit transmitted and received is bit 15 of the register being addressed. Lucent Technologies Inc. 29 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 MII Station Management (continued) Management Registers (MR) Register Overview The MII management 16-bit register (MR) set is implemented as described in the table below. Table 10. MII Management Registers (MR) 30 Register Address Symbol Default (Hex Code) 0 MR0 Control Register 3000 1 MR1 Status Register 7849 2 MR 2 PHY Identifier Register 1 0180 3 MR 3 PHY Identifier Register 2 7641 4 MR4 Autonegotiation Advertisement Register 01E1 5 MR5 Autonegotiation Link Partner Ability Register (base page) 0000 5 MR5 Autonegotiation Link Partner Ability Register (next page) — 6 MR6 Autonegotiation Expansion Register 0000 7 MR7 Next-Page Transmit Register 0000 8—27 MR8—MR27 Reserved 0000 28 MR28 Device-Specific Register 1 — 29 MR29 Device-Specific Register 2 1080 0000 Name 30 MR30 Device-Specific Register 3 31 MR31 Quick Status Register — Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX MII Station Management (continued) This section provides a detailed discussion of each management register and its bit definitions. Table 11. MR0—Control Register Bit Descriptions Register/Bit1 Type2 Description 0.15 (SW_RESET) R/W 0.14 (LOOPBACK) R/W 0.13 (SPEED100) R/W 0.12 (NWAY_ENA) R/W 0.11 (PWRDN) R/W 0.10 (ISOLATE) R/W 0.9 (REDONWAY) R/W 0.8 (FULL_DUP) R/W 0.7 (COLTST) R/W 0.6:0 (RESERVED) NA Reset. Setting this bit to a 1 will reset the entire (all 4 ports, even when only 1 port is addressed) LU3X54FTL. All registers will be set to their default state. This bit is self-clearing. The default is 0. Loopback. When this bit is set to 1, no data transmission will take place on the media. Any receive data will be ignored. The loopback signal path will contain all circuitry up to but not including the PMD. The default value is a 0. Speed Selection. The value of this bit reflects the current speed of operation (1 = 100 Mbits/s, 0 = 10 Mbits/s). This bit will only affect operating speed when the autonegotiation enable bit (register 0, bit 12) is disabled (0). This bit is ignored when autonegotiation is enabled (register 0, bit 12). This bit is ANDed with the SPEEDLED[D] pin during powerup and reset. The default state is a 1. Autonegotiation Enable. The autonegotiation process will be enabled by setting this bit to a 1. The default state is a 1. Powerdown. The LU3X54FTL may be placed in a low-power state by setting this bit to a 1, both the 10 Mbits/s transceiver and the 100 Mbits/s transceiver will be powered down. While in the powerdown state, the LU3X54FTL will respond to management transactions. The default state is a 0. Isolate Mode. When this bit is set to a 1, the MII outputs will be brought to the high-impedance state. The default state is a 0. This bit is ORed with the SPEEDLED[A]/ISOLATE_MODE pin during powerup and reset. Restart Autonegotiation. Normally, the autonegotiation process is started at powerup. The process may be restarted by setting this bit to a 1. The default state is a 0. The NWAYDONE bit (register 1, bit 5) is reset when this bit goes to a 1. This bit is self-cleared when autonegotiation restarts. Duplex Mode. This bit reflects the mode of operation (1 = full duplex, 0 = half duplex). This bit is ignored when the autonegotiation enable bit (register 0, bit 12) is enabled. The default state is a 0. This bit is ORed with the H_DUPLED[D] pin during powerup or reset. Collision Test. When this bit is set to a 1, the LU3X54FTL will assert the COL signal in response to TX_EN. This bit should only be set when in loopback mode. Reserved. All bits will read 0. 1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the register, and the name of the instantiated pad is in capital letters. 2. R = read, W = write, NA = not applicable. Lucent Technologies Inc. 31 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 MII Station Management (continued) Table 12. MR1—Status Register Bit Descriptions Register/Bit1 Type2 1.15 (T4ABLE) R 100Base-T4 Ability. This bit will always be a 0. R 0: Not able. 1: Able. 100Base-TX Full-Duplex Ability. This bit will always be a 1. R 0: Not able. 1: Able. 100Base-TX Half-Duplex Ability. This bit will always be a 1. R 0: Not able. 1: Able. 10Base-T Full-Duplex Ability. This bit will always be a 1. R 0: Not able. 1: Able. 10Base-T Half-Duplex Ability. This bit will always be a 1. 1.14 (TXFULDUP) 1.13 (TXHAFDUP) 1.12 (ENFULDUP) 1.11 (ENHAFDUP) 1.10:7 (RESERVED) 1.6 (NO_PA_OK) R R 1.5 (NWAYDONE) R 1.4 (REM_FLT) R 1.3 (NWAYABLE) R 1.2 (LSTAT_OK) R 1.1 (JABBER) R 1.0 (EXT_ABLE) R Description 0: Not able. 1: Able. Reserved. All bits will read as a 0. Suppress Preamble. This bit is set to a 1 indicating that the LU3X54FTL accepts management frames with the preamble suppressed. Autonegotiation Complete. When this bit is a 1, it indicates the autonegotiation process has been completed. The contents of registers MR4, MR5, MR6, and MR7 are now valid. The default value is a 0. This bit is reset when autonegotiation is started. Remote Fault. When this bit is a 1, it indicates a remote fault has been detected. This bit will remain set until cleared by reading the register. The default is a 0. Autonegotiation Ability. When this bit is a 1, it indicates the ability to perform autonegotiation. The value of this bit is always a 1. Link Status. When this bit is a 1, it indicates a valid link has been established. This bit has a latching function: a link failure will cause the bit to clear and stay cleared until it has been read via the management interface. Jabber Detect. This bit will be a 1 whenever a jabber condition is detected. It will remain set until it is read, and the jabber condition no longer exists. Extended Capability. This bit indicates that the LU3X54FTL supports the extended register set (MR2 and beyond). It will always read a 1. 1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the register, and the name of the instantiated pad is in capital letters. 2. R = read. 32 Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX MII Station Management (continued) Table 13. MR2, 3—PHY Identifier Registers (1 and 2) Bit Descriptions Register/Bit1 Type2 Description 2.15:0 (OUI[3:18]) R 3.15:10 (OUI[19:24]) R 3.9:4 (MODEL[5:0]) R 3.3:0 (VERSION[3:0]) R Organizationally Unique Identifier. The third through the twenty-fourth bit of the OUI assigned to the PHY manufacturer by the IEEE are to be placed in bits [2.15:0] and [3.15:10]. The value for bits 15:0 is 0180h. Organizationally Unique Identifier. The remaining 6 bits of the OUI. The value for bits 15:10 is 1Dh. Model Number. 6-bit model number of the device. The model number is 54 DEC. Revision Number. The value of the present revision number. The value is 01h for the first version. 1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the register, and the name of the instantiated pad is in capital letters. 2. R = read. Table 14. MR4—Autonegotiation Advertisement Register Bit Descriptions Register/Bit1 Type2 4.15 (NEXT_PAGE) R/W Next Page. The next-page function is activated by setting this bit to a 1. This will allow the exchange of additional data. Data is carried by optional next pages of information. 4.14 (ACK) R/W Acknowledge. This bit is the acknowledge bit from the link code word. 4.13 (REM_FAULT) R/W Remote Fault. When set to 1, the LU3X54FTL indicates to the link partner a remote fault condition. 4.12:11 (RESERVED) NA Reserved. These bits will read 0. 4.10 (PAUSE) R/W Pause. When set to a 1, it indicates that the LU3X54FTL wishes to exchange flow control information with its link partner. 4.9 (100BASET4) R/W 100Base-T4. This bit should always be set to 0. 4.8 (100BASET_FD) R/W 100Base-TX Full Duplex. If written to 1, autonegotiation will advertise that the LU3X54FTL is capable of 100Base-TX full-duplex operation. 4.7 (100BASETX) R/W 100Base-TX. If written to 1, autonegotiation will advertise that the LU3X54FTL is capable of 100Base-TX operation. 4.6 (10BASET_FD) R/W 10Base-T Full Duplex. If written to 1, autonegotiation will advertise that the LU3X54FTL is capable of 10Base-T full-duplex operation. 4.5 (10BASET) R/W 10Base-T. If written to 1, autonegotiation will advertise that the LU3X54FTL is capable of 10Base-T operation. 4.4:0 (SELECT) R/W Selector Field. Reset with the value 00001 for IEEE 802.3. Description 1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the register, and the name of the instantiated pad is in capital letters. 2. R = read, W = write, NA = not applicable. Lucent Technologies Inc. 33 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 MII Station Management (continued) Table 15. MR5—Autonegotiation Link Partner (LP) Ability Register (Base Page) Bit Descriptions Register/Bit1 Type2 Description 5.15 (LP_NEXT_PAGE) R 5.14 (LP_ACK) R 5.13 (LP_REM_FAULT) R 5.12:5 (LP_TECH_ABILITY) R 5.4:0 (LP_SELECT) R Link Partner Next Page. When this bit is set to 1, it indicates that the link partner wishes to engage in next-page exchange. Link Partner Acknowledge. When this bit is set to 1, it indicates that the link partner has successfully received at least three consecutive and consistent FLP bursts. Remote Fault. When this bit is set to 1, it indicates that the link partner has a fault. Technology Ability Field. This field contains the technology ability of the link partner. These bits are similar to the bits defined for the MR4 register (see Table 14). Selector Field. This field contains the type of message sent by the link partner. For IEEE 802.3u compliant link partners, this field should read 00001. 1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the register, and the name of the instantiated pad is in capital letters. 2. R = read. Table 16. MR5—Autonegotiation Link Partner (LP) Ability Register (Next Page) Bit Descriptions Register/Bit1 Type2 Description 5.15 (LP_NEXT_PAGE) R 5.14 (LP_ACK) R 5.13 (LP_MES_PAGE) R 5.12 (LP_ACK2) R 5.11 (LP_TOGGLE) R 5.10:0 (MCF) R Next Page. When this bit is set to a logic 0, it indicates that this is the last page to be transmitted. A logic 1 indicates that additional pages will follow. Acknowledge. When this bit is set to a logic 1, it indicates that the link partner has successfully received its partner’s link code word. Message Page. This bit is used by the NEXT_PAGE function to differentiate a message page (logic 1) from an unformatted page (logic 0). Acknowledge 2. This bit is used by the NEXT_PAGE function to indicate that a device has the ability to comply with the message (logic 1) or not (logic 0). Toggle. This bit is used by the arbitration function to ensure synchronization with the link partner during next-page exchange. Logic 0 indicates that the previous value of the transmitted link code word was logic 1. Logic 1 indicates that the previous value of the transmitted link code word was logic 0. Message/Unformatted Code Field. With these 11 bits, there are 2048 possible messages. Message code field definitions are described in annex 28C of the IEEE 802.3u standard. 1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the register, and the name of the instantiated pad is in capital letters. 2. R = read. 34 Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX MII Station Management (continued) Table 17. MR6—Autonegotiation Expansion Register Bit Descriptions Register/Bit1 Type2 Description 6.15:5 (RESERVED) 6.4 (PAR_DET_FAULT) R R/LH 6.3 (LP_NEXT_PAGE_ABLE) 6.2 (NEXT_PAGE_ABLE) R R 6.1 (PAGE_REC) R/LH 6.0 (LP_NWAY_ABLE) R Reserved. Parallel Detection Fault. When this bit is set to 1, it indicates that a fault has been detected in the parallel detection function. This fault is due to more than one technology detecting concurrent link conditions. This bit can only be cleared by reading this register. Link Partner Next Page Able. When this bit is set to 1, it indicates that the link partner supports the next-page function. Next Page Able. This bit is set to 1, indicating that this device supports the next-page function. Page Received. When this bit is set to 1, it indicates that a NEXT_PAGE has been received. Link Partner Autonegotiation Capable. When this bit is set to 1, it indicates that the link partner is autonegotiation capable. 1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the register, and the name of the instantiated pad is in capital letters. 2. R = read, LH = latched high. Table 18. MR7—Next-Page Transmit Register Bit Descriptions Register/Bit1 Type2 Description 7.15 (NEXT_PAGE) R/W 7.14 (ACK) 7.13 (MESSAGE) R R/W 7.12 (ACK2) R/W Next Page. This bit indicates whether or not this is the last NEXT_PAGE to be transmitted. When this bit is 0, it indicates that this is the last NEXT_PAGE. When this bit is 1, it indicates there is an additional NEXT_PAGE. Acknowledge. This bit is the acknowledge bit from the link code word. Message Page. This bit is used to differentiate a message page from an unformatted page. When this bit is 0, it indicates an unformatted page. When this bit is 1, it indicates a formatted page. Acknowledge 2. This bit is used by the next-page function to indicate that a device has the ability to comply with the message. It is set as follows: ■ 7.11 (TOGGLE) R When this bit is 0, it indicates the device cannot comply with the message. ■ When this bit is 1, it indicates the device will comply with the message. Toggle. This bit is used by the arbitration function to ensure synchronization with the link partner during next-page exchange. This bit will always take the opposite value of the toggle bit in the previously exchanged link code word: 7.10:0 (MCF) R/W ■ If the bit is a logic 0, the previous value of the transmitted link code word was a logic 1. ■ If the bit is a 1, the previous value of the transmitted link code word was a 0. The initial value of the toggle bit in the first next-page transmitted is the inverse of the value of bit 11 in the base link code word, and may assume a value of 1 or 0. Message/Unformatted Code Field. With these 11 bits, there are 2048 possible messages. Message code field definitions are described in annex 28C of the IEEE 802.3u standard. 1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the register, and the name of the instantiated pad is in capital letters. 2. R = read, W = write. Lucent Technologies Inc. 35 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 MII Station Management (continued) Table 19. MR28—Device-Specific Register 1 (Status Register) Bit Descriptions Register/Bit1 Type2 Description 28.15:9 (R28[15:9]) 28.8 (BAD_FRM) R R/LH Unused. Read as 0. Bad Frame. If this bit is a 1, it indicates a packet has been received without an SFD. This bit is only valid in 10 Mbits/s mode. 28.7 (CODE) 28.6 (APS) R/LH R 28.5 (DISCON) R/LH 28.4 (UNLOCKED) R/LH 28.3 (RXERR_ST) R/LH 28.2 (FRC_JAM) R/LH 28.1 (LNK100UP) R 28.0 (LNK10UP) R This bit is latching high and will only clear after it has been read or the device has been reset. This bit defaults to 0. Code Violation. When this bit is a 1, it indicates a Manchester code violation has occurred. The error code will be output on the RXD lines. Refer to Table 3 for a detailed description of the RXD pin error codes. This bit is only valid in 10 Mbits/s mode. This bit is latching high and will only clear after it has been read or the device has been reset. This bit defaults to 0. Autopolarity Status. When register 30, bit 3 is set and this bit is a 1, it indicates the LU3X54FTL has detected and corrected a polarity reversal on the twisted pair. If the APF_EN bit (register 30, bit 3) is set, the reversal will be corrected inside the LU3X54FTL. This bit is not valid in 100 Mbits/s operation. This bit defaults to 0. Disconnect. If this bit is a 1, it indicates a disconnect. This bit will latch high until read. This bit is only valid in 100 Mbits/s mode. This bit defaults to 0. Unlocked. Indicates that the TX scrambler lost lock. This bit will latch high until read. This bit is only valid in 100 Mbits/s mode. This bit defaults to 0. RX Error Status. Indicates a false carrier. This bit will latch high until read. This bit is only valid in 100 Mbits/s mode. This bit defaults to 0. Force Jam. This bit will latch high until read. This bit is only valid in 100 Mbits/s mode. This bit defaults to 0. Link Up 100. This bit, when set to a 1, indicates a 100 Mbits/s transceiver is up and operational. This bit defaults to 0. Link Up 10. This bit, when set to a 1, indicates a 10 Mbits/s transceiver is up and operational. This bit defaults to 0. 1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the register, and the name of the instantiated pad is in capital letters. 2. R = read, LH = latched high. 36 Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX MII Station Management (continued) Table 20. MR29—Device-Specific Register 2 (100 Mbits/s Control) Bit Descriptions Register/Bit1 Type2 Description 29.15 (LOCALRST) R/W 29.14 (RST1) 29.13 (RST2) 29.12 (100OFF) R/W R/W R/W 29.11 (RESERVED) 29.10 (CRS_SEL) R/W R/W 29.9 (LINK_ERR) R/W 29.8 (PKT_ERR) R/W 29.7 (PULSE_STR) R/W 29.6 (ENC_DEC_BYPASS) R/W 29.5 (SAB) R/W 29.4 (SCRAM_DESC_BYPASS) R/W 29.3 (CARIN_EN) R/W 29.2 (JAM_COL) R/W 29.1 (FEF_EN) R/W 29.0 FX_MODE_EN R/W Management Reset. This is the local management reset bit. Writing a logic 1 to this bit will cause register zero and registers 28 and 29 to be reset to their default values. This bit is self-clearing. Default state is 0. Generic Reset 1. This register is used for manufacture test only. Default state is 0. Generic Reset 2. This register is used for manufacture test only. Default state is 0. 100 Mbits/s Transmitter Off. When this bit is set to 0, it forces TPOUT+[D:A] low and TPOUT–[D:A] high. This bit defaults to 1. Reserved. Program to zero. Carrier Sense Select. CRS will be asserted on receive only when this bit is set to a 1. If this bit is set to logic 0, CRS will by asserted on receive or transmit. This bit is ORed with the H_DUPLED[B] pin during powerup and reset. Default state is 0. Link Error Indication. When this bit is a 1, a link error code will be reported on RXD[3:0] of the LU3X54FTL when RX_ER is asserted on the MII. The specific error codes are listed in the RXD pin description. If it is 0, it will disable this function. Default state is 0. Packet Error Indication Enable. When this bit is a 1, a packet error code, which indicates that the scrambler is not locked, will be reported on RXD[3:0] of the LU3X54FTL when RX_ER is asserted on the MII. When this bit is 0, it will disable this function. Default state is 0. Pulse Stretching. When this bit is set to 1, the COLED[D:A], TXLED[D:A], and RXLED[D:A] output signal will be stretched between approximately 42 ms—84 ms. If this bit is set to 0, it will disable this feature. Default state is 1. Encoder/Decoder Bypass. When this bit is set to 1, the 4B/5B encoder and 5B/4B decoder function will be disabled. This bit is ORed with the TXLED[C] pin during powerup and reset. Default state is 0. Symbol Aligner Bypass. When this bit is set to 1, the aligner function will be disabled. Default state is 0. Scrambler/Descrambler Bypass. When this bit is set to 1, the scrambling/ descrambling functions will be disabled. This bit is ORed with the TXLED[B] pin during powerup and reset. Default state is 0. Carrier Integrity Enable. When this bit is set to a 1, carrier integrity is enabled. This bit is ORed with the TXLED[D] pin during powerup and reset. Default state is 0. Jam Enable. When this bit is a 1, it enables JAM associated with carrier integrity to be ORed with COL. Default state is 0. Far-End Fault Enable. This bit is used to enable the far-end fault detection and transmission capability. This capability may only be used if autonegotiation is disabled. This capability is to be used only with media which does not support autonegotiation. Setting this bit to 1 enables far-end fault detection and generation. Logic 0 will disable the function. Default state is 0. FX Mode Enable. When set high, this bit will enable the FX mode (10Base-T and 100Base-TX disabled). When low, it will enable 10Base-T and 100Base-TX mode (100Base-FX mode disabled). This bit defaults to zero. It is ORed with the FX mode enable pin. 1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the register, and the name of the instantiated pad is in capital letters. 2. R = read, W = write. Lucent Technologies Inc. 37 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 MII Station Management (continued) Table 21. MR30—Device-Specific Register 3 (10 Mbits/s Control) Bit Descriptions Register/Bit1 Type2 Description 30.15:7 (R28[15:7]) 30.6 (CLK_SEL) R/W R/W 30.5 (HBT_EN) R/W 30.4 (ELL_EN) R/W 30.3 (APF_DIS) R/W Unused. Read as 0. 20 MHz Clock Select. When this bit is a 1, it enables the two-clock input mode (20 MHz and 25 MHz). When this bit is a 0, it enables the single-clock input mode 25 MHz (with 20 MHz clock internally generated). Default state is 0. Heartbeat Enable. When this bit is a 1, the heartbeat function will be enabled. Valid in 10 Mbits/s mode only. Default state is 0. Extended Line Length Enable. When this bit is a 1, the receive squelch levels are reduced from a nominal 435 mV to 350 mV, allowing reception of signals with a lower amplitude. Valid in 10 Mbits/s mode only. Default state is 0. Autopolarity Function Disable. When this bit is a 0 and the LU3X54FTL is in 10 Mbits/s mode, the autopolarity function will determine if the TP link is wired with a polarity reversal. 30.2 (REF_SEL) R/W 30.1 (SERIAL _SEL) R/W 30.0 (ENA_NO_LP) R/W If there is a polarity reversal, the LU3X54FTL will assert the APS bit (register 28, bit 6) and correct the polarity reversal. If this bit is a 1 and the device is in 10 Mbits/s mode, the reversal will not be corrected. Default state is 0. Reference Select. When this bit is a 1, the external 10 MHz reference input clock REF10 is used for phase alignment. Default state is 0. Serial Select. When this bit is set to a 1, 10 Mbits/s serial mode will be selected. When the LU3X54FTL is in 100 Mbits/s mode, this bit will be ignored. This bit is ORed with the H_DUPLED[C] pin during powerup and reset. Default state is 0. No Link Pulse Mode. Setting this bit to a 1 will allow 10 Mbits/s operation with link pulses disabled. If the LU3X54FTL is configured for 100 Mbits/s operation, setting this bit will not affect operation. This bit is ORed with the LINKLED[A] pin during powerup and reset. Default state is 0. 1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the register, and the name of the instantiated pad is in capital letters. 2 R = read, W = write. 38 Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX MII Station Management (continued) Table 22. MR31—Device-Specific Register 4 (Quick Status) Bit Descriptions Register/Bit1 Type2 Description 31.15 (ERROR) R 31.14 (RXERR_ST)/ (LINK_STAT_CHANGE) R 31.13 (REM_FLT) R 31.12 (UNLOCKED)/ (JABBER) R 31.11 (LSTAT_OK) R 31.10 (PAUSE) R 31.9 (SPEED100) R 31.8 (FULL_DUP) R 31.7 (INT_CONF) R/W 31.6 (INT_MASK) R/W 31.5:3 (LOW_AUTO__STATE) R Receiver Error. When this bit is a 1, it indicates that a receive error has been detected. This bit is valid in 100 Mbits/s only. This bit will remain set until cleared by reading the register. Default is a 0. False Carrier. When bit [31.7] is set to 0 and this bit is a 1, it indicates that the carrier detect state machine has found a false carrier. This bit is valid in 100 Mbits/s only. This bit will remain set until cleared by reading the register. Default is 0. Link Status Change. When bit [31.7] is set to a 1, this bit is redefined to become the LINK_STAT_CHANGE bit and goes high whenever there is a change in link status (bit [31.11] changes state). Remote Fault. When this bit is a 1, it indicates a remote fault has been detected. This bit will remain set until cleared by reading the register. Default is a 0. Unlocked/Jabber. If this bit is set when operating in 100 Mbits/s mode, it indicates that the TX descrambler has lost lock. If this bit is set when operating in 10 Mbits/s mode, it indicates a jabber condition has been detected. This bit will remain set until cleared by reading the register. Link Status. When this bit is a 1, it indicates a valid link has been established. This bit has a latching low function: a link failure will cause the bit to clear and stay cleared until it has been read via the management interface. Link Partner Pause. When this bit is set to a 1, it indicates that the LU3X54FTL wishes to exchange flow control information. Link Speed. When this bit is set to a 1, it indicates that the link has negotiated to 100 Mbits/s. When this bit is a 0, it indicates that the link is operating at 10 Mbits/s. Duplex Mode. When this bit is set to a 1, it indicates that the link has negotiated to full-duplex mode. When this bit is a 0, it indicates that the link has negotiated to halfduplex mode. Interrupt Configuration. When this bit is set to a 0, it defines bit [31.14] to be the RXERR_ST bit and the interrupt pin (MASK_STAT_INT) goes high whenever any of bits [31.15:12] go high, or bit [31.11] goes low. When this bit is set high, it redefines bit [31.14] to become the LINK_STAT_CHANGE bit, and the interrupt pin (MASK_STAT_INT) goes high only when the link status changes (bit [31.14] goes high). This bit defaults to 0. Interrupt Mask. When set high, no interrupt is generated by this channel under any condition. When set low, interrupts are generated according to bit [31.7]. Lowest Autonegotiation State. These 3 bits report the state of the lowest autonegotiation state reached since the last register read, in the priority order defined below: 31.2:0 (HI_AUTO_STATE) R 000: Autonegotiation enable. 001: Transmit disable or ability detect. 010: Link status check. 011: Acknowledge detect. 100: Complete acknowledge. 101: FLP link good check. 110: Next-page wait. 111: FLP link good. Highest Autonegotiation State. These 3 bits report the state of the highest autonegotiation state reached since the last register read, as defined above for bit [31.5:3]. 1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the register, and the name of the instantiated pad is in capital letters. 2 R = read; W = write. Lucent Technologies Inc. 39 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 MII Station Management (continued) Unmanaged Operations The LU3X54FTL allows the user to set some of the station management functions during powerup or reset by strapping outputs high or low through weak resistors (50 kΩ). Table 23 shows the functions and their associated output pin. For detailed information on the function of these output pins, refer to the section on management registers described earlier in this data sheet. Also, information on how these output pins should be strapped is discussed in the Pin Descriptions section (Table 3 through Table 7). Table 23. Output Pins Function (Register/Bit) Pin Internal Pull-Up/Pull-Down PHYADD[2:0] NO_LP SPEED CARIN_EN ENC_DEC_BYPASS SCRAM_DESC_BYPASS REF_SEL CLK20_SEL FULL _DUP SERIAL_SEL CRS_SEL BUSED_MII_MODE SMART_MODE_SELECT ISOLATE_MODE FX_MODE_EN RESERVED LINKLED[D:B] LINKLED[A] SPEEDLED[D] TXLED[D] TXLED[C] TXLED[B] TXLED[A] H_DUPLED[A] H_DUPLED[D] H_DUPLED[C] H_DUPLED[B] SPEEDLED[B] SPEEDLED[C] SPEEDLED[A] RXLED[D:A] COLED[B:A] None 50 kΩ down 100 kΩ up 50 kΩ down 50 kΩ down 50 kΩ down 50 kΩ down 50 kΩ down 50 kΩ down 50 kΩ down 50 kΩ down 50 kΩ down 50 kΩ down 50 kΩ down 50 kΩ down 50 kΩ down Mode Select Table 24. LU3X54FTL Modes MODE[4:0] 00000 00001—11111 40 Description Normal operation Reserved Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Absolute Maximum Ratings (TA = 25 °C) Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operational sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability. Table 25. Absolute Maximum Ratings Parameter Ambient Operating Temperature Storage Temperature Power Dissipation Voltage on Any Pin with Respect to Ground Maximum Supply Voltage Symbol Min Max Unit TA Tstg PD — — 0 –40 — –0.5 — 70 125 3.5 DD V + 0.5 5.5 °C °C W V V Table 26. Operating Conditions Parameter Operating Supply Voltage Power Dissipation: All Ports 100 Mbits/s TX All Ports 100 Mbits/s FX All Ports 10 Mbits/s All Ports Autonegotiating Symbol — Min 4.75 Typ* 5.0 Max 5.25 Unit V PD PD PD PD — — — — 3.0 2.2 2.0 1.5 — — — — W W W W * Typical power dissipations are specified at 5.0 V and 25 °C. This is the power dissipated by the LU3X54FTL. An additional 0.2 W of power is required for the external twisted-pair driver termination resistors. Electrical Characteristics The following specifications apply for VDD = 5 V ± 5%, VDD3 = 5 V ± 5% or VDD3 = 3.3 V ± 5%. Table 27. dc Characteristics Parameter Symbol Min Typ Max Unit TTL Inputs: VDD3 = 3.3 V ± 5% Input High Voltage Input Low Voltage Input High Current Input Low Current Input Leakage Current VIH VIL IIH IIL IL 2.0 — — — — — — — — — — 0.8 50 –400 50 V V µA µA µA CMOS Inputs: VDD3 = 5.0 V ± 5% Input High Voltage Input Low Voltage Input High Current Input Low Current Input Leakage Current VIH VIL IIH IIL IL 3.0 — — — — — — — — — — 0.5 1 –1 1 V V µA µA µA TTL Outputs: VDD3 = 3.3 V ± 5% or VDD3 = 5.0 V ± 5% Output High Voltage Output Low Voltage Output Short-circuit Current VOH VOL ISC 2.4 — –4 — — — — 0.45 –85 V V mA Lucent Technologies Inc. 41 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 Electrical Characteristics (continued) Table 27. dc Characteristics (continued) Parameter Symbol Min Typ Max Unit 10 Mbits/s Twisted Pair: Input Voltage VDIFF 0.35 — 2.0 V 100 Mbits/s Twisted Pair: Input Voltage VDIFF — — 1.5 V 10 Mbits/s Twisted Pair: Output Current VDIFF 45 50 55 mA 100 Mbits/s Twisted Pair: Output Current VDIFF 19 20 21 mA Timing Characteristics (Preliminary) Table 28. MII Management Interface Timing (25 pF Load) Name t1 t2 t3 t4 t5 t6 Parameter MDIO Valid to Rising Edge of MDC (setup) Rising Edge of MDC to MDIO Invalid (hold) MDC Falling Edge to MDIO Valid (prop. delay) MDC High* MDC Low* MDC Period* Min Typ Max Unit 10 10 0 — 40 80 — — — 200 200 400 — — 40 — — — ns ns ns ns ns ns * When operating MDC above 6.25 MHz, MDC must be synchronous with LSCLK and have a setup time of 15 ns and a hold time of 5 ns, with respect to LSCLK. MDC MDIO t1 t2 5-4959(F).r1 Figure 9. MDIO Input Timing t6 MDC t5 t4 MDIO t3 5-4960(F).c Figure 10. MDIO Output Timing 42 Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Timing Characteristics (Preliminary) (continued) <R> <Z> <O> MDC MDIO 5-5312(F) Note: MDIO turnaround (TA) time is a 2-bit time spacing between the register address field, and the data field of a frame to avoid drive contention on MDIO during a read transaction. During a write to the LU3X54FTL, these bits are driven to a 10 by the station. During a read, the MDIO is not driven during the first bit time and is driven to a 0 by the LU3X54FTL during the second bit time. Figure 11. MDIO During TA (Turnaround) of a Read Transaction Table 29. MII Data Timing (25 pF Load) Name Parameter Min Typ Max Unit t1 t2 t3 t4 t5 t6 t7 t8 t9 t10 t11 t12 t13 t14 RXD[3:0], RX_ER, RX_DV Valid to RX_CLK High RX_CLK High to RXD[3:0], RX_DV, RX_ER Invalid RX_CLK High RX_CLK Low RX_CLK Period TX_CLK High TX_CLK Low TX_CLK Period TXD, TX_EN, TX_ER, Setup to TX_CLK TXD, TX_EN, TX_ER, Hold to TX_CLK TXD, TX_EN, TX_ER, Setup to LSCLK* TXD, TX_EN, TX_ER, Hold to LSCLK* TX_CLK Skew from LSCLK First Bit of J on TPIN± While Transmitting Data to COL Assert (half-duplex mode) First Bit of T Received on TPIN± While Transmitting to COL Deasserted (half-duplex mode) 10/100 10/100 14/180 14/180 — 14/180 14/180 — 18/140 0/0 12 0 TBD — — — — — 40 — — 40 — — — — — — — — 26/220 26/220 — 26/220 26/220 — — — — — TBD 170 ns ns ns ns ns ns ns ns ns ns ns ns ns ns — — 210 ns t15 * 100 Mbits/s only. Lucent Technologies Inc. 43 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 Timing Characteristics (Preliminary) (continued) t5 t4 t3 RX_CLK RXD[3:0] RX_DV RX_ER t1 t2 t8 TX_CLK t7 TXD[3:0] TX_EN TX_ER t6 t9 t10 LSCLK TXD[3:0] TX_EN TX_ER t11 t12 LSCLK TX_CLK t13 1st BIT OF J 1st BIT OF T TPIN± COL t14 t15 5-5432(F).r2 Figure 12. MII Timing Requirements for LU3X54FTL 44 Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Timing Characteristics (Preliminary) (continued) Table 30. Serial 10 Mbits/s Timing for TPIN, CRS, and RX_CLK Name t16 t17 t18 t19 Parameter TPIN Activity to CRS Assertion TPIN Activity to RX_CLK Valid IDL to CRS Deassertion Dead Signal to CRS Deassertion Min Max Unit 40 800 200 400 500 2300 550 1000 ns ns ns ns (RECEIVE—DEAD SIGNAL) (NOT IDL) (RECEIVE—START OF PACKET) (RECEIVE—END OF PACKET) TPIN± IDL CRS t16 t19 t18 RX_CLK t17 5-5293(F).cr3 Figure 13. Serial 10 Mbits/s Timing for TPIN, CRS, and RX_CLK Table 31. Serial 10 Mbits/s Timing for TX_EN, TPOUT, CRS, and RX_CLK Name t20 t21 t22 t23 t24 Parameter TX_EN Asserted to Transmit Pair Activity TX_EN Asserted to CRS Asserted Due to Internal Loopback TX_EN Asserted to RX_CLK Valid Due to Internal Loopback TX_EN Deasserted to IDL Transmission IDL Pulse Width (TRANSMIT—START OF PACKET) Min Max Unit 50 5 1000 50 250 400 1900 1700 300 350 ns ns ns ns ns (TRANSMIT—END OF PACKET) TX_EN TPOUT± IDL t20 t23 t24 CRS t21 RX_CLK t22 5-5293(F).dr3 Figure 14. Serial 10 Mbits/s Timing for TX_EN, TPOUT, CRS, and RX_CLK Lucent Technologies Inc. 45 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 Timing Characteristics (Preliminary) (continued) Table 32. Serial 10 Mbits/s Timing for TX_EN, TPIN, and COL Name Parameter Min Max Unit t25 t26 Time to Assert COL; LU3X54FTL Is Transmitting; Receive Activity Starts Time to Deassert COL; LU3X54FTL Is Transmitting; Receive Activity Ceases Time to Assert COL; LU3X54FTL Is Receiving; Transmit Activity Starts Time to Deassert COL; LU3X54FTL Is Receiving; Transmit Activity Ceases COL Pulse Width 40 300 400 900 ns ns 5 5 100 400 900 — ns ns ns t27 t28 t29 (TRANSMITTING—RECEIVE COLLISION DETECTED) (RECEIVING—TRANSMIT COLLISON DETECTED) TX_EN TPIN± IDL COL t25 t26 t27 t28 t29 5-5293(F).er3 Figure 15. Serial 10 Mbits/s Timing for TX_EN, TPIN, and COL 46 Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Timing Characteristics (Preliminary) (continued) Table 33. Serial 10 Mbits/s Timing for RX_CLK, CRS, RXD, TX_CLK, TX_EN, and TXD (25 pF Load) Name Parameter t30 t31 t32 t33 t34 t35 t36 RXD Setup Before RX_CLK Rising Edge RXD Held Past RX_CLK Edge RX_CLK Low to CRS Deassertion (at end of received packet) TX_EN Setup Before TX_CLK Rising Edge TX_EN Held Past TX_CLK Rising Edge TXD Setup Before TX_CLK Rising Edge TXD Held Past TX_CLK Rising Edge Min Max Unit 30 30 40 30 0 30 0 — — — — — — — ns ns ns ns ns ns ns RX_CLK CRS t32 RXD t30 (START OF PACKET) t31 (END OF PACKET) TX_CLK t33 t34 TX_EN t35 t36 TXD LAST BIT 5-2736(C).b Figure 16. Serial 10 Mbits/s Timing for RX_CLK, CRS, RXD, TX_CLK, TX_EN, and TXD Lucent Technologies Inc. 47 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 Timing Characteristics (Preliminary) (continued) Table 34. Serial 10 Mbits/s Timing for RX_CLK and TX_CLK (25 pF Load) Name t37 t38 t39 t40 Parameter RX_CLK Low Pulse Width RX_CLK High Pulse Width TX_CLK Low Pulse Width TX_CLK High Pulse Width t37 t38 t39 t40 Min Max Unit 45 45 45 45 55 55 55 55 ns ns ns ns RX_CLK TX_CLK 5-2737(F).br3 Figure 17. Serial 10 Mbits/s Timing Diagram for RX_CLK and TX_CLK 48 Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Timing Characteristics (Preliminary) (continued) Table 35. 100 Mbits/s MII Transmit Timing Name Parameter Min Max Unit t41 t42 t43 Rising Edge of TX_CLK Following TX_EN Assertion to CRS Assertion Rising Edge of TX_CLK Following TX_EN Assertion to TPOUT± Rising Edge of TX_CLK Following TX_EN Deassertion to CRS Deassertion — — — 40 60 40 ns ns ns TX_CLK TX_EN TXD[3:0] t43 t41 CRS 1st BIT OF J 1st BIT OF T t42 TPOUT± 5-3745(F).br4 Figure 18. 100 Mbits/s MII Transmit Timing Lucent Technologies Inc. 49 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 Timing Characteristics (Preliminary) (continued) Table 36. 100 Mbits/s MII Receive Timing Name Parameter Min Max Unit t44 t45 t46 t47 TPIN± 1st Bit of J Receive Activity to CRS Asserted TPIN± Receive Activity to Receive Data Valid TPIN± Receive Activity Cease (1st bit of T) to CRS Deasserted TPIN± Receive Activity Cease (1st bit of T) to Receive Data Not Valid — — — — 170 210 210 210 ns ns ns ns 1st BIT OF J 1st BIT OF T TPIN± t46 t44 CRS RX_CLK t45 RX_DV t47 RX_ER RXD[3:0] 5-3747(F).br4 Figure 19. 100 Mbits/s MII Receive Timing 50 Lucent Technologies Inc. Data Sheet July 2000 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Outline Diagram 208-Pin SQFP Dimensions are in millimeters. 30.60 ± 0.20 28.00 ± 0.20 PIN #1 IDENTIFIER ZONE 208 157 1 1.30 REF 156 0.25 GAGE PLANE SEATING PLANE 0.50/0.75 28.00 ± 0.20 DETAIL A 30.60 ± 0.20 0.090/0.200 105 52 0.17/0.27 53 0.10 104 DETAIL A M DETAIL B DETAIL B 3.40 ± 0.20 4.10 MAX SEATING PLANE 0.08 0.50 TYP 0.25 MIN 5-2196(F).r13 Lucent Technologies Inc. 51 LU3X54FTL QUAD-FET for 10Base-T/100Base-TX/FX Data Sheet July 2000 Ordering Information Device Code Comcode Package Temperature LU3X54FTL-HS208-DB 108420167 208-Pin SQFPH (Heat Spreader) 0 °C to 70 °C For additional information, contact your Microelectronics Group Account Manager or the following: http://www.lucent.com/micro INTERNET: [email protected] E-MAIL: N. AMERICA: Microelectronics Group, Lucent Technologies Inc., 555 Union Boulevard, Room 30L-15P-BA, Allentown, PA 18109-3286 1-800-372-2447, FAX 610-712-4106 (In CANADA: 1-800-553-2448, FAX 610-712-4106) ASIA PACIFIC: Microelectronics Group, Lucent Technologies Singapore Pte. Ltd., 77 Science Park Drive, #03-18 Cintech III, Singapore 118256 Tel. (65) 778 8833, FAX (65) 777 7495 CHINA: Microelectronics Group, Lucent Technologies (China) Co., Ltd., A-F2, 23/F, Zao Fong Universe Building, 1800 Zhong Shan Xi Road, Shanghai 200233 P. R. China Tel. (86) 21 6440 0468, ext. 325, FAX (86) 21 6440 0652 JAPAN: Microelectronics Group, Lucent Technologies Japan Ltd., 7-18, Higashi-Gotanda 2-chome, Shinagawa-ku, Tokyo 141, Japan Tel. (81) 3 5421 1600, FAX (81) 3 5421 1700 EUROPE: Data Requests: MICROELECTRONICS GROUP DATALINE: Tel. (44) 1189 324 299, FAX (44) 1189 328 148 Technical Inquiries: GERMANY: (49) 89 95086 0 (Munich), UNITED KINGDOM: (44) 1344 865 900 (Bracknell), FRANCE: (33) 1 48 83 68 00 (Paris), SWEDEN: (46) 8 600 7070 (Stockholm), FINLAND: (358) 9 4354 2800 (Helsinki), ITALY: (39) 2 6608131 (Milan), SPAIN: (34) 1 807 1441 (Madrid) Lucent Technologies Inc. reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Copyright © 2000 Lucent Technologies Inc. All Rights Reserved Printed in U.S.A. July 2000 DS00-354LAN (Replaces DS98-277LAN)