Single Supply Voltage:
– 2.7V to 3.6V for M24M01-V
– 1.8V to 3.6V for M24M01-S
■
Write Control Input
■
BYTE and PAGE WRITE (up to 128 Bytes)
■
RANDOM and SEQUENTIAL READ Modes
■
Self-Timed Programming Cycle
■
Automatic Address Incrementing
■
Enhanced ESD/Latch-Up Behavior
■
More than 100000 Erase/Write Cycles
■
More than 40 Year Data Retention
January 2003
LGA
LGA8 (LA)
1/19
M24M01
SUMMARY DESCRIPTION
The M24M01 is a 1 Mbit (131,072 x 8) electrically
erasable programmable memory (EEPROM) accessed by an I2C-compatible bus.
Figure 2. Logic Diagram
VCC
When writing data to the memory, the device inserts an acknowledge bit during the 9th bit time,
following the bus master’s 8-bit transmission.
When data is read by the bus master, the bus
master acknowledges the receipt of the data byte
in the same way. Data transfers are terminated by
a Stop condition after an Ack for Write, and after a
NoAck for Read.
Figure 3. LGA Connections
2
E1-E2
SCL
SDA
M24M01
M24M01
DU
E1
E2
VSS
WC
VSS
1
2
3
4
8
7
6
5
VCC
WC
SCL
SDA
AI04051C
AI04048B
Table 1. Signal Names
E1, E2
Chip Enable
SDA
Serial Data
SCL
Serial Clock
WC
Write Control
VCC
Supply Voltage
VSS
Ground
These devices are compatible with the I2C memory protocol. This is a two wire serial interface that
uses a bi-directional data bus and serial clock. The
devices carry a built-in 4-bit Device Type Identifier
code (1010) in accordance with the I2C bus definition.
The device behaves as a slave in the I2C protocol,
with all memory operations synchronized by the
serial clock. Read and Write operations are initiated by a Start condition, generated by the bus master. The Start condition is followed by a Device
Select Code and RW bit (as described in Table 2),
terminated by an acknowledge bit.
2/19
Note: 1. DU = Don’t Use (should be left unconnected, or tied to
VSS)
Power On Reset: V CC Lock-Out Write Protect
In order to prevent data corruption and inadvertent
Write operations during Power-up, a Power On
Reset (POR) circuit is included. The internal reset
is held active until VCC has reached the POR
threshold value, and all operations are disabled –
the device will not respond to any command. In the
same way, when VCC drops from the operating
voltage, below the POR threshold value, all operations are disabled and the device will not respond
to any command. A stable and valid VCC must be
applied before applying any logic signal.
When the power supply is turned on, V CC rises
from VSS to VCC(min), passing through a value Vth
in between. The device ignores all instructions until a time delay of tPU has elapsed after the moment that VCC rises above the Vth threshold.
However, the correct operation of the device is not
guaranteed if, by this time, VCC is still below
VCC(min).No instructions should be sent until the
later of:
– tPU after V CC passed the Vth threshold
– VCC passed the VCC(min) level
These values are specified in Table 9.
M24M01
SIGNAL DESCRIPTION
Serial Clock (SCL)
This input signal is used to strobe all data in and
out of the device. In applications where this signal
is used by slave devices to synchronize the bus to
a slower clock, the bus master must have an open
drain output, and a pull-up resistor must be connected from Serial Clock (SCL) to VCC. (Figure 4
indicates how the value of the pull-up resistor can
be calculated). In most applications, though, this
method of synchronization is not employed, and
so the pull-up resistor is not necessary, provided
that the bus master has a push-pull (rather than
open drain) output.
Serial Data (SDA)
This bi-directional signal is used to transfer data in
or out of the device. It is an open drain output that
may be wire-OR’ed with other open drain or open
collector signals on the bus. A pull up resistor must
be connected from Serial Data (SDA) to V CC. (Figure 4 indicates how the value of the pull-up resistor
can be calculated).
Chip Enable (E1, E2)
These input signals are used to set the value that
is to be looked for on bits b3 and b2 of the 7-bit Device Select Code. These inputs must be tied to
VCC or V SS, to establish the Device Select Code.
When unconnected, the Chip Enable (E1, E2) signals are internally read as VIL (see Tables 10 and
11).
Write Control (WC)
This input signal is useful for protecting the entire
contents of the memory from inadvertent write operations. Write operations are disabled to the entire memory array when Write Control (WC) is
driven High. When unconnected, the signal is internally read as VIL, and Write operations are allowed.
When Write Control (WC) is driven High, Device
Select and Address bytes are acknowledged,
Data bytes are not acknowledged.
Figure 4. Maximum R L Value versus Bus Capacitance (CBUS) for an I2C Bus
VCC
Maximum RP value (kΩ)
20
16
RL
12
RL
SDA
MASTER
8
fc = 100kHz
4
fc = 400kHz
CBUS
SCL
CBUS
0
10
100
1000
CBUS (pF)
AI01665
3/19
M24M01
DEVICE OPERATION
The device supports the I2C protocol. This is summarized in Figure 2. Any device that sends data on
to the bus is defined to be a transmitter, and any
device that reads the data to be a receiver. The
device that controls the data transfer is known as
the bus master, and the other as the slave device.
A data transfer can only be initiated by the bus
master, which will also provide the serial clock for
synchronization. The M24M01 device is always a
slave in all communication.
Start Condition
Start is identified by a falling edge of Serial Data
(SDA) while Serial Clock (SCL) is stable in the
High state. A Start condition must precede any
data transfer command. The device continuously
monitors (except during a Write cycle) Serial Data
(SDA) and Serial Clock (SCL) for a Start condition,
and will not respond unless one is given.
Stop Condition
Stop is identified by a rising edge of Serial Data
(SDA) while Serial Clock (SCL) is stable and driven High. A Stop condition terminates communication between the device and the bus master. A
Read command that is followed by NoAck can be
followed by a Stop condition to force the device
into the Stand-by mode. A Stop condition at the
end of a Write command triggers the internal EEPROM Write cycle.
Acknowledge Bit (ACK)
The acknowledge bit is used to indicate a successful byte transfer. The bus transmitter, whether it be
bus master or slave device, releases Serial Data
(SDA) after sending eight bits of data. During the
9th clock pulse period, the receiver pulls Serial
Data (SDA) Low to acknowledge the receipt of the
eight data bits.
Data Input
During data input, the device samples Serial Data
(SDA) on the rising edge of Serial Clock (SCL).
For correct device operation, Serial Data (SDA)
must be stable during the rising edge of Serial
Clock (SCL), and the Serial Data (SDA) signal
must change only when Serial Clock (SCL) is driven Low.
Memory Addressing
To start communication between the bus master
and the slave device, the bus master must initiate
a Start condition. Following this, the bus master
sends the Device Select Code, shown in Table 2
(on Serial Data (SDA), most significant bit first).
The Device Select Code consists of a 4-bit Device
Type Identifier, and a 2-bit Chip Enable “Address”
(E1, E2). To address the memory array, the 4-bit
Device Type Identifier is 1010b.
Up to four memory devices can be connected on a
single I 2C bus. Each one is given a unique 2-bit
code on the Chip Enable (E1, E2) inputs. When
the Device Select Code is received on Serial Data
(SDA), the device only responds if the Chip Enable
Address is the same as the value on the Chip Enable (E1, E2) inputs.
The 8th bit is the Read/Write bit (RW). This bit is
set to 1 for Read and 0 for Write operations.
If a match occurs on the Device Select code, the
corresponding device gives an acknowledgment
on Serial Data (SDA) during the 9th bit time. If the
device does not match the Device Select code, it
deselects itself from the bus, and goes into Standby mode.
Table 2. Device Select Code 1
Device Type Identifier
Device Select Code
RW
b7
b6
b5
b4
b3
b2
b1
b0
1
0
1
0
E2
E1
A16
RW
Note: 1. The most significant bit, b7, is sent first.
4/19
Chip Enable Address
M24M01
Figure 5. I2C Bus Protocol
SCL
SDA
SDA
Input
START
Condition
SCL
1
2
SDA
MSB
SDA
Change
STOP
Condition
3
7
8
9
ACK
START
Condition
SCL
1
SDA
MSB
2
3
7
8
9
ACK
STOP
Condition
AI00792B
Table 3. Operating Modes
Mode
Current Address Read
RW bit
WC 1
Bytes
1
X
1
0
X
Random Address Read
Initial Sequence
START, Device Select, RW = 1
START, Device Select, RW = 0, Address
1
reSTART, Device Select, RW = 1
1
X
Sequential Read
1
X
≥1
Byte Write
0
VIL
1
START, Device Select, RW = 0
Page Write
0
VIL
≤ 128
START, Device Select, RW = 0
Similar to Current or Random Address Read
Note: 1. X = VIH or VIL.
5/19
M24M01
Figure 6. Write Mode Sequences with WC=1 (data write inhibited)
WC
ACK
BYTE ADDR
ACK
BYTE ADDR
NO ACK
DATA IN
STOP
DEV SEL
START
BYTE WRITE
ACK
R/W
WC
ACK
DEV SEL
START
PAGE WRITE
ACK
BYTE ADDR
ACK
BYTE ADDR
NO ACK
DATA IN 1
DATA IN 2
R/W
WC (cont'd)
NO ACK
DATA IN N
STOP
PAGE WRITE
(cont'd)
NO ACK
AI01120C
Write Operations
Following a Start condition the bus master sends
a Device Select Code with the RW bit reset to 0.
The device acknowledges this, as shown in Figure
7, and waits for two address bytes. The device responds to each address byte with an acknowledge
bit, and then waits for the data byte.
Writing to the memory may be inhibited if Write
Control (WC) is driven High. Any Write instruction
with Write Control (WC) driven High (during a period of time from the Start condition until the end of
the two address bytes) will not modify the memory
contents, and the accompanying data bytes are
not acknowledged, as shown in Figure 6.
Each data byte in the memory has a 17-bit address. The most significant bit, A16, is sent with
the Device Select Code, and the remaining bits,
A15-A0, in the two address bytes. The Most Significant Byte is sent first, followed by the Least Sig-
6/19
nificant Byte. Bits A16 to A0 form the address of
the byte in memory.
When the bus master generates a Stop condition
immediately after the Ack bit (in the “10 th bit” time
slot), either at the end of a Byte Write or a Page
Write, the internal memory Write cycle is triggered.
A Stop condition at any other time slot does not
trigger the internal Write cycle.
During the internal Write cycle, Serial Data (SDA)
is disabled internally, and the device does not respond to any requests.
Byte Write
After the Device Select code and the address
bytes, the bus master sends one data byte. If the
addressed location is Write-protected, by Write
Control (WC) being driven High, the device replies
with NoAck, and the location is not modified. If, instead, the addressed location is not Write-protected, the device replies with Ack. The bus master
M24M01
terminates the transfer by generating a Stop condition, as shown in Figure 7.
Page Write
The Page Write mode allows up to 128 bytes to be
written in a single Write cycle, provided that they
are all located in the same ’row’ in the memory:
that is, the most significant memory address bits
(b16-b7) are the same. If more bytes are sent than
will fit up to the end of the row, a condition known
as ‘roll-over’ occurs. This should be avoided, as
data starts to become overwritten in an implementation dependent way.
The bus master sends from 1 to 128 bytes of data,
each of which is acknowledged by the device if
Write Control (WC) is Low. If Write Control (WC) is
High, the contents of the addressed memory location are not modified, and each data byte is followed by a NoAck. After each byte is transferred,
the internal byte address counter (the 7 least significant address bits only) is incremented. The
transfer is terminated by the bus master generating a Stop condition.
Figure 7. Write Mode Sequences with WC=0 (data write enabled)
WC
ACK
BYTE ADDR
ACK
BYTE ADDR
ACK
DATA IN
STOP
DEV SEL
START
BYTE WRITE
ACK
R/W
WC
ACK
DEV SEL
START
PAGE WRITE
ACK
BYTE ADDR
ACK
BYTE ADDR
ACK
DATA IN 1
DATA IN 2
R/W
WC (cont'd)
ACK
DATA IN N
STOP
PAGE WRITE
(cont'd)
ACK
AI01106C
7/19
M24M01
Figure 8. Write Cycle Polling Flowchart using ACK
WRITE Cycle
in Progress
START Condition
DEVICE SELECT
with RW = 0
NO
First byte of instruction
with RW = 0 already
decoded by the device
ACK
Returned
YES
NO
Next
Operation is
Addressing the
Memory
YES
Send Address
and Receive ACK
ReSTART
NO
STOP
YES
DATA for the
WRITE Operation
DEVICE SELECT
with RW = 1
Continue the
WRITE Operation
Continue the
Random READ Operation
Minimizing System Delays by Polling On ACK
During the internal Write cycle, the device disconnects itself from the bus, and writes a copy of the
data from its internal latches to the memory cells.
The maximum Write time (tw) is shown in Table
12, but the typical time is shorter. To make use of
this, a polling sequence can be used by the bus
master.
The sequence, as shown in Figure 8, is:
– Initial condition: a Write cycle is in progress.
8/19
START
Condition
AI01847C
– Step 1: the bus master issues a Start condition
followed by a Device Select Code (the first byte
of the new instruction).
– Step 2: if the device is busy with the internal
Write cycle, no Ack will be returned and the bus
master goes back to Step 1. If the device has
terminated the internal Write cycle, it responds
with an Ack, indicating that the device is ready
to receive the second part of the instruction (the
first byte of this instruction having been sent
during Step 1).
M24M01
Figure 9. Read Mode Sequences
ACK
DATA OUT
STOP
START
DEV SEL
NO ACK
R/W
ACK
START
DEV SEL *
ACK
BYTE ADDR
ACK
DEV SEL *
ACK
DATA OUT 1
ACK
ACK
NO ACK
DATA OUT N
BYTE ADDR
ACK
BYTE ADDR
ACK
DEV SEL *
START
START
ACK
R/W
ACK
DATA OUT
R/W
R/W
DEV SEL *
NO ACK
STOP
START
DEV SEL
SEQUENTIAL
RANDOM
READ
BYTE ADDR
R/W
ACK
SEQUENTIAL
CURRENT
READ
ACK
START
RANDOM
ADDRESS
READ
STOP
CURRENT
ADDRESS
READ
ACK
DATA OUT 1
R/W
NO ACK
STOP
DATA OUT N
AI01105C
Note: 1. The seven most significant bits of the Device Select Code of a Random Read (in the 1 st and 4th bytes) must be identical.
Read Operations
Read operations are performed independently of
the state of the Write Control (WC) signal.
Random Address Read
A dummy Write is performed to load the address
into the address counter (as shown in Figure 9) but
without sending a Stop condition. Then, the bus
master sends another Start condition, and repeats
the Device Select Code, with the RW bit set to 1.
The device acknowledges this, and outputs the
contents of the addressed byte. The bus master
must not acknowledge the byte, and terminates
the transfer with a Stop condition.
Current Address Read
The device has an internal address counter which
is incremented each time a byte is read. For the
Current Address Read operation, following a Start
condition, the bus master only sends a Device Select Code with the RW bit set to 1. The device acknowledges this, and outputs the byte addressed
by the internal address counter. The counter is
then incremented. The bus master terminates the
9/19
M24M01
transfer with a Stop condition, as shown in Figure
9, without acknowledging the byte.
Sequential Read
This operation can be used after a Current Address Read or a Random Address Read. The bus
master does acknowledge the data byte output,
and sends additional clock pulses so that the device continues to output the next byte in sequence.
To terminate the stream of bytes, the bus master
must not acknowledge the last byte, and must
generate a Stop condition, as shown in Figure 9.
The output data comes from consecutive addresses, with the internal address counter automatically
10/19
incremented after each byte output. After the last
memory address, the address counter ‘rolls-over’,
and the device continues to output data from
memory address 00h.
Acknowledge in Read Mode
For all Read commands, the device waits, after
each byte read, for an acknowledgment during the
9th bit time. If the bus master does not drive Serial
Data (SDA) Low during this time, the device terminates the data transfer and switches to its Standby mode.
M24M01
MAXIMUM RATING
Stressing the device above the rating listed in the
Absolute Maximum Ratings" table may cause permanent damage to the device. These are stress
ratings only and operation of the device at these or
any other conditions above those indicated in the
Operating sections of this specification is not im-
plied. Exposure to Absolute Maximum Rating conditions for extended periods may affect device
reliability. Refer also to the STMicroelectronics
SURE Program and other relevant quality documents.
Table 4. Absolute Maximum Ratings
Symbol
Parameter
TSTG
Storage Temperature
TLEAD
Lead Temperature during Soldering LGA: 20 seconds (max) 1
Min.
Max.
Unit
–65
150
°C
235
°C
VIO
Input or Output range
–0.6
4.2
V
VCC
Supply Voltage
–0.3
4.2
V
VESD
Electrostatic Discharge Voltage (Human Body model) 2
–3000
3000
V
Note: 1. IPC/JEDEC J-STD-020A
2. JEDEC Std JESD22-A114A (C1=100 pF, R1=1500 Ω, R2=500 Ω)
11/19
M24M01
DC AND AC PARAMETERS
This section summarizes the operating and measurement conditions, and the DC and AC characteristics of the device. The parameters in the DC
and AC Characteristic tables that follow are derived from tests performed under the Measure-
ment Conditions summarized in the relevant
tables. Designers should check that the operating
conditions in their circuit match the measurement
conditions when relying on the quoted parameters.
Table 5. Operating Conditions (M24M01-V)
Symbol
VCC
TA
Parameter
Min.
Max.
Unit
Supply Voltage
2.7
3.6
V
Ambient Operating Temperature
–40
85
°C
Min.
Max.
Unit
Supply Voltage
1.8
3.6
V
Ambient Operating Temperature
–40
85
°C
Min.
Max.
Unit
Table 6. Operating Conditions (M24M01-S)
Symbol
VCC
TA
Parameter
Table 7. AC Measurement Conditions
Symbol
CL
Parameter
Load Capacitance
30
Input Rise and Fall Times
pF
50
ns
Input Pulse Voltages
0.2VCC to 0.8VCC
V
Input and Output Timing Reference Voltages
0.3VCC to 0.7VCC
V
Note: 1. Output Hi-Z is defined as the point where data out is no longer driven.
Figure 10. AC Measurement I/O Waveform
Input Levels
Input and Output
Timing Reference Levels
0.8VCC
0.7VCC
0.3VCC
0.2VCC
AI00825B
Table 8. Capacitance
Symbol
Parameter
Min.
Max.
Unit
CIN
Input Capacitance (SDA)
8
pF
CIN
Input Capacitance (other pins)
6
pF
tNS
Pulse width ignored
(Input Filter on SCL and SDA)
50
ns
Note: 1. TA = 25 °C, f = 400 kHz
2. Sampled only, not 100% tested.
12/19
Test Condition
M24M01
Table 9. Power-Up Timing and Vth Threshold
Test Condition1
Symbol
Parameter
tPU
Time delay to Read or Write instruction
Vth
Threshold Voltage
Min.
Max.
Unit
200
µs
1.1
1.4
V
Min.
Max.
Unit
Note: 1. These parameters are characterized only.
Table 10. DC Characteristics (M24M01-V)
Symbol
Test Condition
(in addition to those in Table 5)
Parameter
ILI
Input Leakage Current
(SCL, SDA, E1, E2, WC)
VIN = VSS or VCC
±1
µA
ILO
Output Leakage Current
0 V ≤ VOUT ≤ VCC, SDA in Hi-Z
±2
µA
ICC
Supply Current
VCC =3.6V, fc=400kHz (rise/fall time < 30ns)
2
mA
ICC1
Stand-by Supply Current
VIN = VSS or VCC , 2.7 V ≤ VCC ≤ 3.6 V
2
µA
VIL
Input Low Voltage
(E1, E2, SCL, SDA, WC)
– 0.3
0.3VCC
V
VIH
Input High Voltage
(E1, E2, SCL, SDA, WC)
0.7VCC
VCC+1
V
VOL
Output Low Voltage
0.4
V
Max.
Unit
IOL = 2.5 mA, 2.7 V ≤ VCC ≤ 3.6 V
Table 11. DC Characteristics (M24M01-S)
Symbol
Parameter
Test Condition
(in addition to those in Table 6)
Min.
ILI
Input Leakage Current
(SCL, SDA, E1, E2, WC)
VIN = VSS or VCC
±1
µA
ILO
Output Leakage Current
0 V ≤ VOUT ≤ VCC, SDA in Hi-Z
±2
µA
ICC
Supply Current
VCC =3.6V, fc=400kHz (rise/fall time < 30ns)
2
mA
ICC1
Stand-by Supply Current
VIN = VSS or VCC , VCC=3.6 V
2
µA
VIL
Input Low Voltage
(E1, E2, SCL, SDA, WC)
– 0.3
0.3VCC
V
VIH
Input High Voltage
(E1, E2, SCL, SDA, WC)
0.7VCC
VCC+1
V
V
Output Low Voltage
IOL = 2.5 mA, 2.7 V ≤ VCC ≤ 3.6 V
0.4
VOL
RL = 2.2 kΩ, 1.8 V ≤ VCC ≤ 3.6 V
0.2VCC
V
13/19
M24M01
Table 12. AC Characteristics
Test conditions specified in Table 7 and Table 5 or Table 6
Symbol
Alt.
Parameter
fC
fSCL
Clock Frequency
tCH1CH2
tR
Clock Rise Time
tCL1CL2
tF
tCHCL
Min.
Max.
Unit
400
kHz
20
300
ns
Clock Fall Time
20
300
ns
tHIGH
Clock Pulse Width High
600
ns
tCLCH
tLOW
Clock Pulse Width Low
1300
ns
tDH1DH2 2
tR
SDA Rise Time
20
300
ns
tDL1DL2 2
tF
SDA Fall Time
20
300
ns
tDXCX
tSU:DAT
Data In Set Up Time
100
ns
tCLDX
tHD:DAT
Data In Hold Time
0
ns
tCLQX
tDH
Data Out Hold Time
200
ns
tCLQV 3
tAA
Clock Low to Next Data Valid (Access Time)
205
tCHDX 1
tSU:STA
Start Condition Set Up Time
600
ns
tDLCL
tHD:STA
Start Condition Hold Time
600
ns
tCHDH
tSU:STO
Stop Condition Set Up Time
600
ns
tDHDL
tBUF
Time between Stop Condition and Next Start
Condition
1300
ns
tW
tWR
Write Time
900
10
ns
ms
Note: 1. For a reSTART condition, or following a Write cycle.
2. Sampled only, not 100% tested.
3. To avoid spurious START and STOP conditions, a minimum delay is placed between SCL=1 and the falling or rising edge of SDA.
14/19
M24M01
Figure 11. AC Waveforms
tCHCL
tCLCH
SCL
tDLCL
SDA In
tCHDX
tCLDX
START
Condition
SDA
Input
SDA tDXCX
Change
tCHDH tDHDL
START
STOP
Condition Condition
SCL
SDA In
tCHDH
tW
STOP
Condition
Write Cycle
tCHDX
START
Condition
SCL
tCLQV
SDA Out
tCLQX
Data Valid
AI00795C
15/19
M24M01
PACKAGE MECHANICAL
LGA8 - 8 lead Land Grid Array, Package Outline
CONTACT 1
D
D1
T3
E1
E
k
T1
T2
E2
E3
A
A2
A1
ddd
LGA-Z01B
Notes: 1. Drawing is not to scale.
LGA8 - 8 lead Land Grid Array, Package Mechanical Data
mm
inches
Symb.
16/19
Typ.
Min.
Max.
Typ.
Min.
Max.
A
1.040
0.940
1.140
0.0409
0.0370
0.0449
A1
0.340
0.300
0.380
0.0134
0.0118
0.0150
A2
0.700
0.640
0.760
0.0276
0.0252
0.0299
D
8.000
7.900
8.100
0.3150
0.3110
0.3189
D1
0.100
–
–
0.0039
–
–
E
5.000
4.900
5.100
0.1969
0.1929
0.2008
E1
1.270
–
–
0.0500
–
–
E2
3.810
–
–
0.1500
–
–
E3
0.390
–
–
0.0154
–
–
k
0.100
–
–
0.0039
–
–
T1
0.410
–
–
0.0161
–
–
T2
0.670
–
–
0.0264
–
–
T3
0.970
–
–
0.0382
–
–
ddd
0.100
–
–
0.0039
–
–
M24M01
PART NUMBERING
Table 13. Ordering Information Scheme
Example:
M24M01
–
V
LA
6
T
Device Type
M24 = I2C serial access EEPROM
Device Function
M01 = 1 Mbit (131,072 x 8)
Operating Voltage
V = VCC = 2.7 to 3.6V
S = VCC = 1.8 to 3.6V
Package
LA = LGA8 (Land Grid Array)
Temperature Range
6 = –40 to 85 °C
Option
T = Tape & Reel Packing
For a list of available options (speed, package,
etc.) or for further information on any aspect of this
device, please contact your nearest ST Sales Office.
17/19
M24M01
REVISION HISTORY
Table 14. Document Revision History
Date
Rev.
02-Oct-2001
1.0
LGA8 Package mechanical data updated
Datasheet released as Product Preview
21-Jun-2002
1.1
Table added on Power-up Timing
Full Datasheet released
08-Jan-2003
1.2
Added LGA maximum rating for soldering temperature
18/19
Description of Revision
M24M01
Information furnished is believed to be accurate and reliable. However, STMicroelectronics assumes no responsibility for the consequences
of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted
by implication or otherwise under any patent or patent rights of STMicroelectronics. Specifications mentioned in this publication are subject
to change without notice. This publication supersedes and replaces all information previously supplied. STMicroelectronics products are not
authorized for use as critical components in life support devices or systems without express written approval of STMicroelectronics.
The ST logo is registered trademark of STMicroelectronics
All other names are the property of their respective owners
© 2003 STMicroelectronics - All Rights Reserved
STMicroelectronics group of companies
Australia - Brazil - Canada - China - Finland - France - Germany - Hong Kong India - Israel - Italy - Japan - Malaysia - Malta - Morocco - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States.
www.st.com
19/19