MA-COM MASW

RoHS
Compliant
GaAs SP4T High Power Switch
DC - 3 GHz
Features
•
•
•
•
•
•
•
•
•
MASW-007813
V2
Functional Schematic
Low Voltage Operation: 2.5 V
Low Harmonics: < -66 dBc at +34 dBm & 1 GHz
Low Insertion Loss: 0.7 dB at 1 GHz
High Isolation: 25 dB at 2 GHz
0.5 micron GaAs PHEMT Process
Low Profile, Lead-Free 3 mm PQFN Package
100% Matte Tin Plating
Halogen-Free “Green” Mold Compound
RoHS* Compliant and 260°C Re-flow Compatible
A
N
T
Pin 16
Pin 1
100 pF
RF1
RF4
100 pF
100 pF
Description
M/A-COM’s MASW-007813 is a GaAs PHEMT
MMIC single pole four throw (SP4T) high power
switch in a low cost, low profile, lead-free 3 mm
PQFN 16-lead package. The MASW-007813 is
ideally suited for applications where high power, low
control voltage, low insertion loss, high
isolation, small size and low cost are required.
Typical applications are for GSM and DCS handset
systems that connect separate transmit and receive
functions to a common antenna, as well as CDMA
handset and other related
applications.
The
MASW-007813 can be used in all systems
operating up to 3 GHz requiring high power at low
control voltage.
RF2
100 pF
MASW-007813-TR3000
3000 piece reel
V1
V4 V3
Pin Configuration
Pin No.
Pin Name
Description
1
RF1
RF Port 1
2
GND
RF Ground
3
GND
RF Ground
4
RF2
RF Port 2
5
V2
Control 2
6
V1
Control 1
7
V4
Control 4
8
V3
Control 3
9
RF3
RF Port 3
10
GND
RF Ground
11
GND
RF Ground
12
RF4
RF Port 4
13
GND
RF Ground
14
ANT
Antenna Port
15
GND
RF Ground
16
GND
RF Ground
17
GND (paddle) 2
RF Ground
Ordering Information 1
Package
100 pF
V2
The MASW-007813 is fabricated using a 0.5 micron
gate length GaAs PHEMT process. The process
features full passivation for performance and
reliability.
Part Number
RF3
1. Reference Application Note M513 for reel size information.
2. The exposed pad centered on the package bottom must be
connected to RF and DC ground.
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
1
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
RoHS
Compliant
GaAs SP4T High Power Switch
DC - 3 GHz
MASW-007813
V2
Electrical Specifications: TA = 25°C, VC = 0 V / 2.75 V, PIN = 34 dBm, Z0 = 50 Ohms 3
Parameter
Test Conditions
Units
Min.
Typ.
Max.
Insertion Loss 4
DC - 1 GHz
1 - 2 GHz
2 - 3 GHz
dB
dB
dB
—
—
—
0.7
0.8
1.0
0.85
—
—
Isolation
DC - 1 GHz
1 - 2 GHz
2 - 3 GHz
dB
dB
dB
25
—
—
33
27
23
—
—
—
Return Loss
DC - 3 GHz
dB
—
20
—
P0.1dB
1 GHz
dBm
—
38
—
IP2
Two Tone, +26 dBm/Tone, 5 MHz spacing, > 50 MHz
dBm
—
96
—
IP3
Two Tone, +26 dBm/Tone, 5 MHz spacing, > 50 MHz
dBm
—
58
—
2nd Harmonic
1 GHz, Pin = +34 dBm
dBc
—
-76
-68
3rd Harmonic
1 GHz, Pin = +34 dBm
dBc
—
-68
-66
Trise, Tfall
10% to 90% RF, 90% to 10% RF
nS
—
40
—
Ton, Toff
50% Control to 90% RF, 50% Control to 10% RF
nS
—
110
—
mV
—
40
—
µA
—
20
80
Transients
Control Current
VC = 2.75 V
3. For positive voltage control, external DC blocking capacitors are required on all RF ports.
4. Insertion loss can be optimized by varying the DC blocking capacitor value, e.g. 1000 pF for 100 MHz - 1 GHz, 39 pF for 0.5 GHz - 3 GHz.
Absolute Maximum Ratings 7
Truth Table 5,6
V1
V2
V3
V4
ANT RF1
ANT - ANT RF2
RF3
1
0
0
0
On
Off
Off
0
1
0
0
Off
On
0
0
1
0
Off
0
0
0
1
Off
ANT RF4
Parameter
Absolute Maximum
Off
Max Input Power
(0.5 - 3 GHz, 2.75 V Control)
+38 dBm
Off
Off
Operating Voltage
+8.5 volts
Off
On
Off
Operating Temperature
-40°C to +85°C
Off
Off
On
Storage Temperature
-65°C to +150°C
5. Differential voltage, V (state 1) - V (state 0), must be +2.5 V
minimum and must not exceed 8.5 V.
6. 0 = -8.5 V to 0 V, 1 = -6 V to 8.5 V
7. Exceeding any one or combination of these limits may cause
permanent damage to this device.
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
RoHS
Compliant
GaAs SP4T High Power Switch
DC - 3 GHz
MASW-007813
V2
Typical Performance Curves
Insertion Loss
Isolation
1.2
40
1.0
35
0.8
30
+25°C
+85°C
-40°C
0.6
0.4
0.5
1.0
1.5
2.0
2.5
+25°C
+85°C
-40°C
25
3.0
20
0.5
1.0
1.5
2.0
2.5
3.0
Frequency (GHz)
Frequency (GHz)
Return Loss
Harmonics vs. Control Voltage, 1 GHz
-60
0
2nd Harmonic
3rd Harmonic
+25°C
+85°C
-40°C
10
-65
20
-70
30
-75
40
0.5
-80
1.0
1.5
2.0
2.5
3.0
Frequency (GHz)
2.0
2.5
3.0
3.5
4.0
4.5
5.0
Control Voltage (V)
3
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
RoHS
Compliant
GaAs SP4T High Power Switch
DC - 3 GHz
MASW-007813
V2
Low Profile, Lead-Free 3 mm 16-lead PQFN †
†
Reference Application Note M538 for lead-free solder reflow recommendations.
Meets JEDEC moisture sensitivity level 1 requirements.
Qualification
Qualified to M/A-COM specification REL-201, Process
Flow –2.
Handling Procedures
The following precautions should be observed to
avoid damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive to
electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
4
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.