MAXIM MAX3053ESA

19-2425; Rev 0; 4/02
±80V Fault-Protected, 2Mbps,
Low Supply Current CAN Transceiver
Features
♦ ±80V Fault Protection
♦ Three Operating Modes
High-Speed Operation up to 2Mbps
Slope Control Mode to Reduce EMI
(40kbps to 500kbps)
♦ 15µA Low-Current Shutdown Mode
♦ Autoshutdown when Device Is Inactive
♦ Automatic Wakeup from Shutdown
♦ Thermal Shutdown
♦ Current Limiting
♦ Fully Compatible with the ISO 11898 Standard
Ordering Information
The MAX3053 is available in an 8-pin SO package and
is specified for -40°C to +125°C operation.
PART
Applications
Industrial Control and Networks
TEMP RANGE
PIN-PACKAGE
MAX3053ESA
-40°C to +85°C
8 SO
MAX3053ASA
-40°C to +125°C
8 SO
Printers
Automotive Systems
Pin Configuration appears at end of data sheet.
HVAC Controls
Telecom 72V Systems
Typical Operating Circuit
VCC
120Ω
100nF
VCC
CANH
TXD
TXD
CAN
CONTROLLER
MAX3053
CANL
RXD
RXD
100nF
SHDN
RS
GND
120Ω
GND
25kΩ TO 180kΩ
________________________________________________________________ Maxim Integrated Products
For pricing delivery, and ordering information please contact Maxim/Dallas Direct! at
1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com.
1
MAX3053
General Description
The MAX3053 interfaces between the control area network (CAN) protocol controller and the physical wires of
the bus lines in a CAN. It is primarily intended for industrial systems requiring data rates up to 2Mbps and features ±80V fault protection against shorts to
high-voltage power buses. The device provides differential transmit capability to the bus and differential
receive capability to the CAN controller.
The MAX3053 has three different modes of operation:
high-speed, slope control, and shutdown. High-speed
mode allows data rates up to 2Mbps. In slope control
mode, data rates are between 40kbps and 500kbps so
the effects of EMI are reduced and unshielded twisted
or parallel cable may be used. In shutdown mode, the
transmitter is switched off, and the receiver is switched
to a low-current mode.
An autoshutdown function puts the device in 15µA shutdown mode when the bus or CAN controller is inactive
for 47ms or greater.
MAX3053
±80V Fault-Protected, 2Mbps,
Low Supply Current CAN Transceiver
ABSOLUTE MAXIMUM RATINGS
VCC to GND ............................................................ -0.3V to +6V
TXD, RS, RXD, SHDN to GND ....................-0.3V to (VCC + 0.3V)
RXD Shorted to GND................................................. Continuous
CANH, CANL to GND...........................-80V to +80V Continuous
Continuous Power Dissipation
8-Pin SO (derate 5.9mW/°C above +70°C) .................470mW
Operating Temperature Ranges
MAX3053ASA ...............................................-40°C to +125°C
MAX3053ESA .................................................-40°C to +85°C
Junction Temperature ......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) ................................+300°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
DC ELECTRICAL CHARACTERISTICS
(VCC = +5V ±10%, RL = 60Ω, RS = GND, TA = TMIN to TMAX, unless otherwise noted. Typical values are at VCC = +5V and TA = +25°C.)
PARAMETER
SYMBOL
CONDITIONS
MIN
Dominant (Note 1)
Supply Current
IS
TYP
MAX
56
72
Dominant (no load)
6
Recessive (Note 1)
3.6
Recessive (no load)
Shutdown Supply Current
IQSHDN
5.5
UNITS
mA
5.5
SHDN = GND
15
30
µA
Thermal Shutdown Threshold
160
°C
Thermal Shutdown Hysteresis
20
°C
TXD INPUT LEVELS
High-Level Input Voltage
VIH
Low-Level Input Voltage
VIL
High-Level Input Current
IIH
Pullup Resistor
2.0
V
0.4
VTXD = VCC
RINTXD
V
1
µA
20
kΩ
CANH, CANL TRANSMITTER
Recessive Bus Voltage
Off-State Output Leakage
VCANH,
VCANL
ILO
VTXD = VCC, no load
2
3
-2V < VCANH, VCANL < +7V,
SHDN = GND, VTXD = VCC
-2
+1
-80V < VCANH, VCANL < +80V,
SHDN = GND, VTXD = VCC
-4
+4
V
mA
CANH Output Voltage
VCANH
VTXD = 0
3.0
VCC
V
CANL Output Voltage
VCANL
VTXD = 0
0
2.0
V
VTXD = 0
1.5
5
VTXD = 0, RL = 45Ω
1.5
VTXD = VCC; no load
-500
-200
Differential Output
(VCANH - VCANL)
∆VCANH,
VCANL
CANH Short-Circuit Current
ISC
VCANH = -5V
CANL Short-Circuit Current
ISC
VCANL = 18V
Human Body Model
ESD CANH, CANL (Note 2)
2
V
+50
mV
200
mA
mA
±2
IEC1000-4-2 Air-Gap Discharge
±3
IEC1000-4-2 Contact Discharge
± 2.5
_______________________________________________________________________________________
kV
±80V Fault-Protected, 2Mbps,
Low Supply Current CAN Transceiver
(VCC = +5V ±10%, RL = 60Ω, RS = GND, TA = TMIN to TMAX, unless otherwise noted. Typical values are at VCC = +5V and TA = +25°C.)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
DC BUS RECEIVER (VTXD = VCC; CANH and CANL externally driven (-2V < VCANH, VCANL < +7V, unless otherwise specified)
Differential Input Voltage
(Recessive)
VDIFF
-7V < VCANH, VCANL < +12V
-1.0
+0.5
V
Differential Input Voltage
(Dominant)
VDIFF
-7V < VCANH, VCANL < +12V
0.9
3.3
V
Differential Input Hysteresis
CANH Input Wakeup Voltage
Threshold
VDIFF(HYST)
VCANH(SHDN) SHDN = GND, VTXD = VCC
RXD High-Level Output Voltage
VOH
RXD Low-Level Output Voltage
VOL
CANH and CANL Input
Resistance
Differential Input Resistance
150
I = -100µA
6
mV
9
0.8 x
VCC
V
V
I = 10mA
0.8
I = 5mA
0.4
V
RI
5
25
kΩ
RDIFF
10
100
kΩ
0.3 x
VCC
V
0.4 x
VCC
0.6 x
VCC
V
-10
-200
µA
-500
µA
SLOPE CONTROL
Input Voltage for High Speed
VSLP
Slope Control Mode Voltage
VSLOPE
RRS = 24kΩ to 180kΩ
Slope Control Mode Current
ISLOPE
RRS = 24kΩ to 180kΩ, VCC = +5.0V
High-Speed Mode Current
IHS
VRS = 0
AUTOSHUTDOWN
SHDN Input Voltage High
SHDN Input Voltage Low
2
V
0.5
V
_______________________________________________________________________________________
3
MAX3053
DC ELECTRICAL CHARACTERISTICS (continued)
MAX3053
±80V Fault-Protected, 2Mbps,
Low Supply Current CAN Transceiver
TIMING CHARACTERISTICS
(VCC = +5V ±10%, RL = 60Ω, CL = 100pF, TA = TMIN to TMAX, unless otherwise noted. Typical values are at VCC = +5V and
TA = +25°C.) (Figures 1, 2, and 3)
PARAMETER
SYMBOL
CONDITIONS
VRS = 0 (2Mbps)
Minimum Bit Time
tBIT
MIN
TYP
MAX
UNITS
0.5
RRS = 24kΩ (500kbps)
2
RRS = 100kΩ (125kbps)
8
RRS = 180kΩ (62.5kbps)
25
µs
Delay TXD to Bus Active
tONTXD
VRS = 0
40
ns
Delay TXD to Bus Inactive
tOFFTXD
VRS = 0
75
ns
VRS = 0 (2Mbps)
120
ns
Delay TXD to Receiver Active
Delay TXD to Receiver Inactive
tONRXD
tOFFRXD
RRS = 24kΩ (500kbps)
0.4
RRS = 100kΩ (125kbps)
1.6
RRS = 180kΩ (62.5kbps)
5.0
VRS = 0 (2Mbps)
130
RRS = 24kΩ (500kbps)
0.45
RRS = 100kΩ (125kbps)
1.6
RRS = 180kΩ (62.5kbps)
5.0
RRS = 24kΩ (500kbps)
Differential Output Slew Rate
|SR|
7
RRS = 180kΩ (62.5kbps)
1.6
tWAKE
SHDN = GND, VTXD = VCC
Time to Sleep Mode when Bus Is
Recessive
tSHDN
CSHDN = 100nF
ns
µs
14
RRS = 100kΩ (125kbps)
Time to Wakeup: CANH > 9V
µs
10
V/µs
10
µs
47
ms
Note 1: As defined by ISOSHDN, bus value is one of two complementary logical values: dominant or recessive. The dominant value
represents the logical 1 and the recessive represents the logical 0. During the simultaneous transmission of the dominant
and recessive bits, the resulting bus value is dominant. For MAX3053 values, see the truth table in the Transmitter and
Receiver sections.
Note 2: The ESD structures do not short out CANH and CANL under an ESD event while -7V < CANH, CANL < +12V.
4
_______________________________________________________________________________________
±80V Fault-Protected, 2Mbps,
Low Supply Current CAN Transceiver
70
TA = -40°C
10
TA = +25°C
50
40
30
20
26
TA = +125°C
TA = +25°C
24
22
10
0
0
20
65
110
155
200
0
50
RRS (kΩ)
CSHDN (nF)
RECEIVER PROPAGATION DELAY vs.
TEMPERATURE (RECESSIVE TO DOMINANT)
DRIVER PROPAGATION DELAY
vs. TEMPERATURE, RRS = GND
25
20
1000
1500
2000
1600
1200
RECESSIVE
VOLTAGE RXD (mV)
30
30
500
RECEIVER OUTPUT LOW
vs. OUTPUT CURRENT
MAX3053 toc05
35
0
DATA RATE (kbps)
35
DRIVER PROPAGATION DELAY (ns)
MAX3053 toc04
40
20
100 150 200 250 300 350 400
MAX3053 toc06
TA = +125°C
25
DOMINANT
20
TA = +25°C
TA = +125°C
800
400
TA = -40°C
15
15
-50
-15
20
55
90
125
0
-40
-7
26
59
92
125
TEMPERATURE (°C)
TEMPERATURE (°C)
RECEIVER OUTPUT HIGH
vs. OUTPUT CURRENT
DIFFERENTIAL VOLTAGE (CANH - CANL)
vs. DIFFERENTIAL LOAD RL
DIFFERENTIAL VOLTAGE (V)
2.4
TA = +25°C
1.8
TA = +125°C
1.2
0.6
4
5
10
15
20
25
OUTPUT CURRENT (mA)
5
MAX3053 toc07
3.0
0
TA = -40°C
RECEIVER PROPAGATION DELAY
(DOMINANT TO RECESSIVE)
MAX3053 toc09
MAX3053 toc08
RECEIVER PROPAGATION DELAY (ns)
SUPPLY CURRENT (mA)
SLEEP TIME (ms)
15
TA = -40°C
28
60
5
VOLTAGE RXD (V)
30
MAX3053 toc02
20
SLEW RATE (V/µs)
80
MAX3053 toc01
25
SUPPLY CURRENT vs. DATA RATE
50% DUTY CYCLE
AUTOSHUTDOWN vs. CSHDN
MAX3053 toc03
SLEW RATE vs. RRS
MAX3053
Typical Operating Characteristics
(VCC = +5V, RL = 60Ω, CL = 100pF, TA = +25°C, unless otherwise specified.)
DIFFERENTIAL
INPUT
3
TA = +125°C
2
TA = +25°C
2V/div
1
TA = -40°C
0
0
0
5
10
15
OUTPUT CURRENT (mA)
20
25
0
50
100
150
200
250
300
40ns/div
DIFFERENTIAL LOAD RL (Ω)
_______________________________________________________________________________________
5
MAX3053
±80V Fault-Protected, 2Mbps,
Low Supply Current CAN Transceiver
Typical Operating Characteristics (continued)
(VCC = +5V, RL = 60Ω, CL = 100pF, TA = +25°C, unless otherwise specified.)
DRIVER PROPAGATION DELAY
DRIVER PROPAGATION DELAY
MAX3053 toc10
MAX3053 toc11
TXD
TXD
5V/div
RRS = 24kΩ
2V/div
RRS = 100kΩ
RRS = GND
RRS = 180kΩ
CANH - CANL
1V/div
CANH - CANL
40ns/div
400ns/div
Pin Description
PIN
FUNCTION
1
TXD
Transmit Data Input. TXD is a CMOS/TTL-compatible input from a CAN controller.
2
GND
Ground
3
VCC
Supply Voltage. Bypass VCC to GND with a 0.1µF capacitor.
4
RXD
Receive Data Output. RXD is a CMOS/TTL-compatible output from the physical bus lines CANH and CANL.
SHDN
Shutdown Input. Drive SHDN low to put the MAX3053 in shutdown mode. See the Detailed Description
section for a full explanation of SHDN behavior.
6
CANL
CAN Bus Line LOW. CANL is fault protected to ±80V.
7
CANH
CAN Bus Line HIGH. CANH is fault protected to ±80V.
8
RS
5
6
NAME
Mode Select Pin. Drive RS low or connect to GND for high-speed operation. Connect a resistor from RS to
GND to control output slope. See the Mode Selection section.
_______________________________________________________________________________________
±80V Fault-Protected, 2Mbps,
Low Supply Current CAN Transceiver
VCC
0.1µF
120Ω
VCC
CANH
TXD
TXD
CAN
CONTROLLER
RXD
MAX3053
CANL
RXD
30pF
100nF
SHDN
RS
GND
120Ω
24kΩ TO 180kΩ
Figure 1. AC Test Circuit
TXD
CANH
9V
CANL
CANH
DOMINANT
0.9V
0.5V
CANH–CANL
RECESSIVE
VSHDN = 2V
VSHDN
tWAKE
RXD
VCC/2
VCC/2
tONTXD
tOFFTXD
tONRXD
tOFFRXD
Figure 2. Timing Diagram for Dynamic Characteristics
Figure 3. Time to Wakeup (twake)
_______________________________________________________________________________________
7
MAX3053
Test Circuits/Timing Diagrams
MAX3053
±80V Fault-Protected, 2Mbps,
Low Supply Current CAN Transceiver
CANH and CANL are output short circuit current limited
and are protected against excessive power dissipation
by thermal-shutdown circuitry that places the driver
outputs into a high-impedance state.
Detailed Description
The MAX3053 interfaces between the protocol controller and the physical wires of a CAN bus. It is primarily intended for industrial applications requiring data
rates up to 2Mbps and features ±80V fault protection
against shorts in high-voltage systems. This fault protection allows the device to withstand up to ±80V with
respect to ground with no damage to the device. The
built-in fault tolerance allows the device to survive in
industrial and automotive environments with no external
protection devices. The device provides differential
transmit capability to the bus and differential receive
capability to the CAN controller (Figure 4).
Fault Protection
The MAX3053 features ±80V fault protection. This
extended voltage range of CANH and CANL bus lines
allows its use in high-voltage systems and communicating to high-voltage buses. If data is transmitting at
2Mbps, the fault protection is reduced to ±70V.
Transmitter
The transmitter converts a single-ended input (TXD)
from the CAN controller to differential outputs for the
bus lines (CANH, CANL). Table 1 is the truth table for
the transmitter and receiver.
The device has three modes of operations: high-speed,
slope control, and shutdown. In high-speed mode, slew
rates are not limited, making 2Mbps transmission
speeds possible. Slew rates are controlled in slope
control mode, minimizing EMI and allowing use of
unshielded twisted or parallel cable. The device goes
into low-power operation in shutdown mode.
The transceiver is designed to operate from a single
+5V supply, and draws 56mA of supply current in dominant state and 3.6mA in recessive state. In shutdown
mode, supply current is reduced to 15µA.
High Speed
Connect RS to ground to set the MAX3053 to highspeed mode. When operating in high-speed mode, the
MAX3053 can achieve transmission rates up to 2Mbps.
Line drivers are switched on and off as quickly as possible. However, in this mode, no measures are taken to
limit the rise and fall slope of the data signal, allowing
for potential EMI emissions. If using the MAX3053 in
high-speed mode, use shielded twisted-pair cable to
avoid EMI problems.
VCC
THERMAL
SHUTDOWN
MAX3053
CANH
TRANSMITTER
CONTROL
TXD
RS
CANL
MODE
SELECTION
GND
RXD
RECEIVER
0.75V
WAKE
AUTOSHUTDOWN
SHDN
7.5V
Figure 4. Block Diagram
8
_______________________________________________________________________________________
±80V Fault-Protected, 2Mbps,
Low Supply Current CAN Transceiver
TXD
SHDN
CANH
CANL
BUS STATE
RXD
0
V SHDN > 1.5V
HIGH
LOW
Dominant**
0
1 or float
V SHDN > 1.5V
5Ω to 25kΩ to Vcc/2
5Ω to 25kΩ to Vcc/2
Recessive**
1
X*
V SHDN < 0.5V
Floating
Floating
Floating
1
*X = Don’t care.
**As defined by ISO, bus value is one of two complementary logical values: dominant or recessive. The dominant value represents
the logical 0 and the recessive represents the logical 1. During the simultaneous transmission of the dominant and recessive bits, the
resulting bus value is dominant.
Slope Control
Connect a resistor from RS to ground to select slope control mode (see Table 2). In slope control mode, the gates
of the line drivers are charged with a controlled current,
proportional to the resistor connected to the RS pin.
Transmission speed ranges from 40kbps to 500kbps.
Controlling the rise and fall slope reduces EMI and allows
the use of an unshielded twisted pair or a parallel pair of
wires as bus lines. The transfer function for selecting the
resistor value is given by:
RRS (kΩ) = 12000 / speed (in kbps).
See the Typical Operating Characteristics for the Slew
Rate vs. RRS graph.
Shutdown
To place the MAX3053 in shutdown, the SHDN pin
should be driven to GND. In shutdown mode, the
device is switched off. The outputs are high impedance
to ±80V.
Receiver
The receiver takes differential input from the bus lines
(CANH, CANL) and converts this data to a singleended output (RXD) to the CAN controller. It consists of
a comparator that senses the difference ∆V = (CANH CANL) with respect to an internal threshold of 0.7V. If
this difference is positive (i.e., ∆V > 0.9V), a logic low is
present at the RXD pin. If negative (i.e., ∆V < 0.5V), a
logic high is present.
The receiver always echoes the transmitted data.
The CANH and CANL common-mode range is from -7V
to +12V. RXD is logic high when CANH and CANL are
shorted or terminated and undriven.
Thermal Shutdown
If the junction temperature exceeds +160°C, the device
is switched off. The hysteresis is about 20°C, disabling
thermal shutdown once the temperature declines to
+140°C and the device is turned back on.
Table 2. Mode Selection Truth Table
CONDITION
FORCED AT PIN RS
MODE
RESULTING
CURRENT AT RS
VRS < 0.3VCC
High speed
|IRs| < 500µA
0.4VCC < VRS <
0.6VCC
Slope control
10µA < |IRs| < 200µA
Autoshutdown
To manage power consumption, autoshutdown puts the
device into shutdown mode after the device has been
inactive for a period of time. The value of an external
capacitor (CSHDN) connected to SHDN determines the
threshold of inactivity time, after which the autoshutdown
triggers (see Typical Operating Characteristics).
Use a 100nF capacitor as CSHDN for a typical threshold
of 20ms. Change the capacitor value according to the
following equation to change the threshold time period:
I
(µA) × time (ms)
C SHDN (nf ) = SHDN
(VCC ˚− ˚VSHDN (V))
Drive SHDN high to force the MAX3053 on and disable
autoshutdown.
When the MAX3053 is in shutdown mode, only the
wakeup comparator is active, and normal bus communication is ignored. The remote master of the CAN system wakes up the MAX3053 with a signal greater than
9V on CANH. The local CAN controller wakes up the
MAX3053 by driving SHDN high or TXD.
Driver Output Protection
The MAX3053 has several features to protect itself from
damage. Thermal shutdown switches off the device
and puts CANH and CANL into high impedance if the
junction temperature exceeds +160°C. Thermal protection is needed particularly when a bus line is short circuited. The hysteresis for the thermal shutdown is
about 20°C.
_______________________________________________________________________________________
9
MAX3053
Table 1. Transmitter and Receiver Truth Table
MAX3053
±80V Fault-Protected, 2Mbps,
Low Supply Current CAN Transceiver
Additionally, a current-limiting circuit protects the transmitter output stage against a short circuit to positive
and negative battery voltage. Although the power dissipation increases during this fault condition, this feature
prevents destruction of the transmitter output stage.
Applications Information
Reduced EMI and Reflections
In slope control mode, the CANH, CANL outputs are
slew-rate limited, minimizing EMI and reducing reflections caused by improperly terminated cables. In general, a transmitter’s rise time relates directly to the
length of an unterminated stub, which can be driven
with only minor waveform reflections. The following
equation expresses this relationship conservatively:
Length = tRISE / (10 x 1.5ns/ft)
where tRISE is the transmitter’s rise time. See Figures 5,
6, and 7 for typical waveforms at various data rates.
The MAX3053 requires no special layout considerations
beyond common practices. Bypass VCC to GND with a
1µF ceramic capacitor mounted close to the IC with
short lead lengths and wide trace widths.
CANH–CANL
5V/div
CANH–CANL
5V/div
FFT
200mV/div
FFT
200mV/div
4.00µs
400ns
31.5kHz
RRS = 180kΩ
250kHz
RRS = 24kΩ
Figure 5. Output Bus in Slope Control Mode at 62.5kbps
Figure 6. Output Bus in Slope Control Mode at 500kbps
Pin Configuration
TOP VIEW
CANH–CANL
5V/div
RS
TXD
1
8
GND
2
7
CANH
VCC
3
6
CANL
RXD
4
5
SHDN
MAX3053
SO
FFT
200mV/div
100ns
1MHz
RRS = 0Ω
Figure 7. Output Bus High-Speed Mode at 2Mbps
10
Chip Information
TRANSISTOR COUNT: 1214
PROCESS: BiCMOS
______________________________________________________________________________________
±80V Fault-Protected, 2Mbps,
Low Supply Current CAN Transceiver
9LUCSP, 3x3.EPS
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are
implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.
Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 ____________________ 11
© 2002 Maxim Integrated Products
Printed USA
is a registered trademark of Maxim Integrated Products.
MAX3053
Package Information
(The package drawing(s) in this data sheet may not reflect the most current specifications. For the latest package outline information,
go to www.maxim-ic.com/packages.)