INTERPOINT MHP28015D

Crane Aerospace & Electronics Power Solutions
MHP270 Single and Dual DC/DC Converters
270 Volt input – 65 Watt
Features
Parallel operation with current share,
up to 5 units (up to 276 watts)
• Operating range -55° to +100°C
• Input voltage 160 to 400 VDC
• Transient protection 450 V for 50 ms
• Fully isolated, magnetic feedback
• Fixed high frequency switching
• Remote sense on single models
• Inhibit primary side and secondary side
models
VDC Output
• Sync In and Sync Out
• Indefinite short circuit protection
single
5
12
15
28
• High power density, up to 85% efficiency
description
dual
±5
±12
±15
The MHP270 Series™ DC/DC converters provide up to 65
watts of output power over -55°C to +100°C temperature range.
MHP270 models operate from a MIL-STD-704 nominal 270-volt
DC power bus with 160 to 400 VDC continuous ­operation with
surges to 450 volts. Isolated outputs include 5, 12, 15, and 28
VDC singles and ±5, ±12 and ±15 VDC duals. Parallel operation
for all loading ­conditions is supported without any requirement for
external components. The converters are available with standard
screening or “ES” screening
limits of MIL-STD-704. The unit shuts down above approximately
425 volts, but it is rated to withstand a surge of up to 450 volts
for 50 milliseconds. The units are built as fully hermetic thick film
hybrids in our MIL-PRF-38534 ­certified facilities.
MHP270 DC/DC converters are constant frequency, pulse width
modulated switching power supplies which use a ­quasi-square
wave, two-switch single-ended forward converter design. Tight
load regulation is achieved through a ­wide-bandwidth magnetic
feedback circuit.
Continuous short circuit protection – current limit set at approximately 125%.
Up to five single output MHP270 converters may be used in
­parallel to power a single load by simply connecting the share
pins of all units. Units in this configuration have an 85% current
sharing accuracy over 35% load to full load conditions.
Remote sense – Sense lines increase the output voltage to
compensate for IR drops in traces and wires. The voltage
compensation can be up to a maximum of 10% of nominal output
voltage to maintain tightly regulated voltage at the load.
MHP270 Series of converters feature a flexible synchronization
scheme in which units may be synchronized to an external clock
or to one another by using Sync In and Sync Out pins ­provided
on each unit. MHP270 converters have a nominal ­switching
frequency of 525 kHz, but may be synchronized at any frequency
from 475 to 575 kHz.
Output Voltage Options
MHP270 converters meet a wide variety of military/aerospace
performance and environmental specifications. Their ­continuous
operation input voltage (160 to 400) meets the ­normal operating
Crane Aerospace & Electronics
Electronics Group (Interpoint Brand)
PO Box 97005 • Redmond WA 98073-9705
425.882.3100 • [email protected]
www.interpoint.com
Features
Undervoltage lock-out – shuts down when the input line voltage
falls below approximately 120 VDC to provide smooth initialization.
Soft-start – controlled start-up at turn-on, release from inhibit and
recovery from load fault conditions.
The MHP270 Series converters are capable of providing other
output voltage options in addition to those characterized on this
datasheet. Contact your sales representative to discuss other
output voltage options, www.interpoint.com/contacts.
US Patents
Interpoint converters may use one or more of the following US
patents 5,521,807, 5,694,303, and 5,631,822.
Page 1 of 10
MHP270 Rev G - 20100517
Crane Aerospace & Electronics Power Solutions
MHP270 Single and Dual DC/DC Converters
270 Volt input – 65 Watt
Operating Conditions and characteristics
Sync and inhibit
Input Voltage Range
•160 to 400 VDC continuous
•450 VDC for 50 msec transient
Sync
•Sync In
‣‣Input frequency 475 to 575 kHz.
‣‣Duty cycle 40% min, 60% max
‣‣Active low 0.8 V max
‣‣Active high 4.5 V min, 10 V max
‣‣Referenced to input common
•Sync Out
‣‣Referenced to input common
Output Power
•50 to 65 watts depending on model
Lead Soldering Temperature (10 sec)
•300°C
Storage Temperature Range (Tc)
•-65°C to +150°C
Inhibit (INH1, INH2)
•In Share (parallel mode) use a common inhibit signal for all
converters
•Active low (output disabled)
‣‣INH1 referenced to input common
Active low 0.8 V max
Inhibit pin will source 15 mA max
‣‣INH2 referenced to output common
Active low 0.2 V max
Inhibit pin will source 15 mA max
•Active high (output enabled)
‣‣Open collector
‣‣Open pin voltage: INH1 = 12V typ, INH2 = 5 V typ
Case Operating Temperature (Tc)
•-55 to +100°C full power
Output Voltage Temperature Coefficient
•100 ppm/°C typical
Current Limit
•125% of full load typical
Isolation
•100 megohm minimum at 500 V
Conversion Frequency
• Free run mode 525 kHz typical
‣‣ 475 kHz. min., 575 kHz max
• External sync range: 475 to 575 kHz
mechanical and environmental
Low Line Drop Out •Vout drops 1% of nominal
•Input voltage 155 VDC max
Size (maximum)
•3.005 x 1.505 x 0.400 inches (76.33 x 38.23 x 10.16 mm)
•See case U for dimensions.
Undervoltage Lockout
•Input voltage 110 VDC min
Weight (maximum)
•86 grams max
Screening
•Standard or ES. See Screening Table 1 for more information.
SINGLE OUTPUT MODELS CONNECTION DIAGRAM - SENSE
270 V
Inhibit
Sync In
+
–
1
Positive Input
2
Input Common
3
INH2
4
INH1
5
6
Sync Out
Sync In
Share 12
N/C 11
Pos. Sense 10
9
Sense Return
8
Output Common
7
Positive Output
REMOTE SENSE CONNECTION
Figure 1: Sense Connections
www.interpoint.com
Page 2 of 10
MHP270 Rev G - 20100517
–
+
RL
Crane Aerospace & Electronics Power Solutions
MHP270 Single and Dual DC/DC Converters
270 Volt input – 65 Watt
PINS NOT IN USE
PIN OUT
Pin
Single Output
Dual Output
Inhibit (INH1, INH2)
Leave unconnected
2
Input Common
Input Common
Sync In
Connect to input common
Inhibit 1 (INH1)
Sense Lines
Must be connected to
appropriate outputs
1
3
4
5
6
7
8
9
10
11
12
Positive Input
Inhibit 2 (INH2)
Inhibit 1 (INH1)
Sync Out
Sync In
Positive Output
Output Common
Sense Return
Positive Sense
No connection
Share
Sync Out
Positive Input
Share
Inhibit 2 (INH2)
Leave unconnected
Sync Out
Sync In
Positive Output
Output Common
Negative Output
No connection
No connection
Share
Angled corner indicates pin one.
1
12
2
3
4
5
6
11
TOP VIEW
MHP
(Pin side, marked side)
See case U for dimensions.
Figure 2: Pin Out
www.interpoint.com
Page 3 of 10
MHP270 Rev G - 20100517
Leave unconnected
10
9
8
7
Crane Aerospace & Electronics Power Solutions
MHP270 Single and Dual DC/DC Converters
270 Volt input – 65 Watt
SINGLE OUTPUT MODELS CONNECTION DIAGRAM - PARALLEL
+
270V
–
Optional fuse
Share 12
N/C 11
1 Positive Input
2 Input Common
3 INH2
Pos. Sense 10
Sense Return 9
4 INH1 MHP270 #1
8
5 Sync Out
Output Common
6
INH2
Control
Sync In
Positive Output
Share 12
N/C 11
1 Positive Input
2 Input Common
3 INH2
4 INH1
Pos. Sense 10
Sense Return 9
MHP270 #2
5 Sync Out
6
Sync In
Output Common
1 Positive Input
2 Input Common
INH1
Control
7
Positive Output
8
7
+
–
RL
Share 12
N/C 11
3 INH2
Pos. Sense
4
MHP270
#N
INH1
Sense Return
5
Sync Out
Output Common
6
Sync In
Positive Output
10
9
8
7
• Dotted lines are optional connections
• Sync in should be connected to input common if not used
• Synchronizing the converters eliminates beat frequencies during current sharing (parallel operation)
• From 2 to 5 converters can be paralleled for up to 276 watts of output power.
• These converters are not designed for use in redundant systems
• If deviating from this diagram, please consult our applications engineers:
[email protected]
www.interpoint.com/contacts/technical_support
+1.425.895.4016
Figure 3: Parallel (Current Sharing) Connections
www.interpoint.com
Page 4 of 10
MHP270 Rev G - 20100517
Crane Aerospace & Electronics Power Solutions
MHP270 Single and Dual DC/DC Converters
270 Volt input – 65 Watt
model numbering key
Base Model
Input Voltage
MHP
270 05 S / ES
Output Voltage
Number of Outputs
(S = single, D = dual)
Screening
(Standard screening has no designator
in this position.)
On
model selection
the lines below, enter one selection from each category to determine the model number.
Category
Selection
/
MHP270
Base Model and
Input Voltage
MHP270 is the only
available selection
Output Voltage
Number of
Outputs 1
Screening 2
05, 12, 15, 28
S
(STANDARD leave blank)
05, 12, 15
D
ES
Notes:
1. Number of Outputs: S is a single output and D is a dual output
2. Screening: For standard screening leave the screening option blank. For the ES screening option, insert the ES in the screening level option.
For more information see Screening Tables 1.
www.interpoint.com
Page 5 of 10
MHP270 Rev G - 20100517
Crane Aerospace & Electronics Power Solutions
MHP270 Single and Dual DC/DC Converters
270 Volt input – 65 Watt
Electrical Characteristics: 25°C Tc, 270 VDC Vin, 100% load, free run, unless otherwise specified.
single output models
PARAMETER
MHP27005S
CONDITIONS
OUTPUT VOLTAGE
mhp27012s
MIN
TYP
MAX
MIN
TYP
MAX
4.95
5.00
5.05
11.88
12.00
12.12
UNITS
VDC
OUTPUT CURRENT
Vin = 160
to
400 VDC
0
—
10
0
—
5
A
OUTPUT POWER
Vin = 160
to
400 VDC
0
—
50
0
—
60
W
10 kHz - 2 MHz
—
—
50
—
—
50
mV p-p
VIN = 160 TO 400 VDC
—
—
50
—
–
120
mV
NO LOAD TO FULL
—
—
50
—
—
120
mV
CONTINUOUS
TRANSIENT 50 msec. 1, 3
160
270
400
160
270
400
VDC
—
—
450
—
—
450
V
NO LOAD
—
—
20
—
—
20
INHIBITED–INH1
—
—
8
—
—
10
INHIBITED–INH2
—
—
15
—
—
15
10 kHz - 10 MHz
—
—
50
—
—
50
mA p-p
OUTPUT RIPPLE
2
LINE REGULATION
LOAD REGULATION 2
INPUT VOLTAGE
INPUT CURRENT
INPUT RIPPLE
CURRENT
EFFICIENCY
mA
76
—
—
81
—
—
%
LOAD FAULT
POWER DISSIPATION
SHORT CIRCUIT
—
—
30
—
—
35
W
STEP LOAD
RESPONSE
50% - 100% - 50%
TRANSIENT
—
—
300
—
—
700
mV pk
RECOVERY 4
—
—
300
—
—
500
µs
—
—
1000
—
—
500
µF
CAPACITIVE LOAD
1
NO EFFECT ON DC
PERFORMANCE
Notes
1. Guaranteed by design, not tested.
2. Load and line transition time > 10 µs
3. Unit will shut down above approximately 425V but will be
undamaged and will restart when voltage drops into normal
range.
www.interpoint.com
4.Recovery time is measured from application of the transient to
point the point at which Vout is within 1% of final value.
Page 6 of 10
MHP270 Rev G - 20100517
Crane Aerospace & Electronics Power Solutions
MHP270 Single and Dual DC/DC Converters
270 Volt input – 65 Watt
Electrical Characteristics: 25°C Tc, 270 VDC Vin, 100% load, free run, unless otherwise specified.
single output models
PARAMETER
MHP27015S
CONDITIONS
OUTPUT VOLTAGE
MHP27028S
MIN
TYP
MAX
MIN
TYP
MAX
14.85
15.00
15.15
27.72
28.00
28.28
UNITS
VDC
OUTPUT CURRENT
Vin = 160
to
400 VDC
0
—
4.33
0
—
2.32
A
OUTPUT POWER
Vin = 160
to
400 VDC
0
—
65
0
—
65
W
OUTPUT RIPPLE
LINE REGULATION 2
10 kHz - 2 MHz
—
—
75
—
—
280
mV p-p
VIN = 160 TO 400 VDC
—
—
150
—
—
280
mV
NO LOAD TO FULL
—
—
150
—
—
280
mV
CONTINUOUS
TRANSIENT 50 msec. 1, 3
160
270
400
160
270
400
VDC
—
—
450
—
—
450
V
LOAD REGULATION
INPUT VOLTAGE
INPUT CURRENT
INPUT RIPPLE
CURRENT
2
NO LOAD
—
—
20
—
—
20
INHIBITED–INH1
—
—
7
—
—
10
INHIBITED–INH2
—
—
15
—
—
15
10 kHz - 10 MHz
—
—
45
—
—
70
mA p-p
80
—
—
80
—
—
%
EFFICIENCY
mA
LOAD FAULT
POWER DISSIPATION
SHORT CIRCUIT
—
—
45
—
—
45
W
STEP LOAD
RESPONSE
50% - 100% - 50%
TRANSIENT
—
—
700
—
—
1800
mV pk
RECOVERY 4
—
—
300
—
—
1000
µs
—
—
500
—
—
500
µF
CAPACITIVE LOAD
1
NO EFFECT ON DC
PERFORMANCE
Notes
1. Guaranteed by design, not tested.
2. Load and line transition time > 10 µs
3. Unit will shut down above approximately 425V but will be
undamaged and will restart when voltage drops into normal
range.
www.interpoint.com
4.Recovery time is measured from application of the transient to
point the point at which Vout is within 1% of final value.
Page 7 of 10
MHP270 Rev G - 20100517
Crane Aerospace & Electronics Power Solutions
MHP270 Single and Dual DC/DC Converters
270 Volt input – 65 Watt
Electrical Characteristics: 25°C Tc, 270 VDC Vin, 100% load, free run, unless otherwise specified.
DUAL output models 2
PARAMETER
OUTPUT VOLTAGE
OUTPUT CURRENT 3
Vin = 160
to
400 VDC
OUTPUT POWER 3
Vin = 160
to
400 VDC
OUTPUT RIPPLE
±VOUT
LINE REGULATION 4
±VOUT
LOAD REGULATION 4, 5
±VOUT
CROSS REGULATION 6
MHP27005D
MHP27012D
MHP28015D
UNITS
CONDITIONS
MIN
TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX
+Vout
4.95
5.00
5.05
11.88
12.00
12.12
14.85
15.00
15.15
-Vout
4.92
5.00
5.08
11.82
12.00
12.18
14.77
15.00
15.23
Each Output
—
±5
8.0 1
—
±2.5
4.0 1
—
±2.16
3.46 1
Total
—
—
10
—
—
5
—
—
4.33
Each Output
—
—
40 1
—
—
48 1
—
—
52 1
Total
—
—
50
—
—
60
—
—
65
10 kHz - 2 MHz
—
50
100
—
50
125
—
50
125
VIN = 160 TO 400 VDC
—
—
100
—
—
120
—
—
150
NO LOAD TO FULL
—
—
100
—
—
120
—
—
150
EFFECT
—
—
1000
—
—
800
—
—
750
mV
ON
–VOUT
VDC
A
W
mV p-p
mV
mV
INPUT VOLTAGE
CONTINUOUS
TRANSIENT 50 msec.1, 7
160
270
400
160
270
400
160
270
400
VDC
0
—
450
0
—
450
0
—
450
V
NO LOAD
—
—
20
—
—
20
—
—
20
INPUT CURRENT
INHIBITED–INH1
—
—
10
—
—
10
—
—
8
INHIBITED–INH2
—
—
15
—
—
15
—
—
15
10 kHz - 10 MHz
—
—
60
—
—
60
—
—
60
EFFICIENCY
BALANCED LOAD
74
—
—
81
_
—
82
_
—
%
LOAD FAULT
POWER DISSIPATION
SHORT CIRCUIT
—
—
30
—
—
35
—
—
45
W
STEP LOAD
RESPONSE
±VOUT
50% - 100% - 50% 8
TRANSIENT
—
—
300
—
—
900
—
—
900
CAPACITIVE LOAD 1
—
—
300
—
—
500
—
—
500
µs
NO EFFECT ON DC
—
—
—
—
—
500
—
—
500
µF
INPUT RIPPLE
CURRENT
RECOVERY
9
PERFORMANCE
Notes
1. Guaranteed by design, not tested.
2. Share operation not characterized for dual outputs.
3.Up to 80% of the total output power is available from either output provided that
the opposite output is simultaneously carrying 20% of the total output power.
4. Load and line transition time > 10 µs
5. Assumes balanced loads on the outputs.
www.interpoint.com
mA
mA p-p
mV pk
6. Effect on the negative output from 50%/50% loads to 70%/30% or 30%/70%
loads.
7.Unit will shut down above approximately 425V but will be undamaged
and will restart when voltage drops into normal range.
8.Second output at 50%
9.Recovery time is measured from application of the transient to point at
which Vout is within 1% of final value.
Page 8 of 10
MHP270 Rev G - 20100517
Crane Aerospace & Electronics Power Solutions
MHP270 Single and Dual DC/DC Converter Cases
270 Volt input – 65 Watt
TOP VIEW CASE U*
Flanged case, short-leaded
*Does not require designator in Case Option position of model number.
1.505 (38.23) max.
11
3
10
0.650 (16.51)
4
9
0.450 (11.43)
5
8
0.250 (6.35)
6
7
0.000
0.120 (3.05)
0.000
Case dimensions in inches (mm)
Tolerance ±0.005 (0.13) for three decimal places
±0.01 (0.3) for two decimal places
unless otherwise specified
CAUTION
Heat from reflow or wave soldering may damage the device. Solder pins
individually with heat application not exceeding 300°C for 10 seconds per pin.
Materials
Header
Cold Rolled Steel/Nickel/Gold
Cover
Kovar/Nickel
Pins
#52 alloy/Gold, compression glass seal
Seal Hole: 0.100 ±0.002 (2.54 ±0.05)
Case U, Rev F, 20100503
Figure 4: Case U
www.interpoint.com
Page 9 of 10
MHP270 Rev G - 20100517
0.220 (5.59
2
0.850 (21.59)
0.050 (1.27)
0.000
1.050 (26.67)
0.040 dia
(1.02)
12
2.750 (69.85)
1
0.120 (3.05)
0.250 (6.35)
1.250 (31.75)
2.880 (73.15)
3.005 (76.33) max.
1.380 (35.05)
Seam Seal
0.128 dia
(3.25).
0.23 (5.8) Pin Length
0.400 (10.16) max.
Angled corner
indicates pin one.
Crane Aerospace & Electronics Power Solutions
MHP270 Single and Dual DC/DC Converters
270 Volt input – 65 Watt
STANDARD AND /ES (NON-QML) PRODUCTS
ENVIRONMENTAL SCREENING 1
standard
nOn-Qml2
/es
nOn-Qml2
Pre-cap Inspection
Method 2017, 2032
yes
yes
Temperature Cycle (10 times)
Method 1010, Cond. B, -55°C to +125°C, ambient
no
yes
Constant Acceleration
Method 2001, 500 g
no
yes
Burn-in
Method 1015 3
96 hours
no
yes
Final Electrical Test MIL-PRF-38534, Group A
Subgroups 1 and 4: +25°C case
yes
yes
Hermeticity Test
Fine Leak, Method 1014, Cond. A
Gross Leak, Method 1014, Cond. C
Gross Leak, Dip (1 x 10-3)
no
no
yes
yes
yes
no
Final visual inspection
Method 2009
yes
yes
test perFOrmed
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
Notes:
1. refers to products that do not offer QMl screening.
2. Standard and /ES, non-QML products, do not meet all of the requirements of MIL-PRF-38534.
3. Burn-in designed to bring the case temperature to the maximum case temperature of the product. Refer to the specific product information
for the maximum case temperature.
Screening Table 1: Environmental Screening
MHP270 Single and Dual, MHP270 Rev G - 20100517. This revision supersedes all previous releases. All technical information is believed to be
accurate, but no responsibility is assumed for errors or omissions. Interpoint reserves the right to make changes in products or specifications without
notice. MHP270 Series is a trademark of Interpoint. Copyright © 1999 - 2010 Interpoint Corporation. All rights reserved. www.interpoint.com
Page 10 of 10