PHOENIX 2900358

Extract from the online
catalog
PLC-OPIT- 24DC/ 48DC/100/SEN
Order No.: 2900358
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900358
PLC sensor interface, consisting of PLC-BPIT...SEN basic terminal
block with Push-In connection and pluggable miniature optocoupler,
for assembly on DIN rail NS 35/7.5, input: 24 V DC, output: 3-48 V
DC/100 mA
Product notes
WEEE/RoHS-compliant since:
04/08/2009
Commercial data
GTIN (EAN)
4
046356
506847
Note
Made-to-order
sales group
G246
Pack
10 pcs.
Customs tariff
85364190
Catalog page information
Page 91 (IF-2011)
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Technical data
Input data
Nominal input voltage UN
24 V DC
Input voltage range in reference to UN
0.8 ... 1.2
Switching threshold "0" signal in reference to UN
≤ 0.4
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 1 / 6
Aug 24, 2011
PLC-OPIT- 24DC/ 48DC/100/SEN Order No.: 2900358
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900358
Switching threshold "1" signal in reference to UN
≥ 0.8
Typical input current at UN
8.5 mA
Typical response time
20 µs (at UN)
Typical turn-off time
300 µs (at UN)
Operating voltage display
Yellow LED
Type of protection
Protection against polarity reversal
Free-wheeling diode
Protective circuit/component
Polarity protection diode
Damping diode
Transmission frequency
300 Hz
Output data
Output nominal voltage range
3 V DC ... 48 V DC
Limiting continuous current
100 mA
Voltage drop at max. limiting continuous current
≤1V
Output circuit
2-wire, floating
Type of protection
Protection against polarity reversal
Surge protection
Protective circuit/component
Polarity protection diode
Connection data
Connection method
Push-In connection
Stripping length
8 mm
Conductor cross section solid min.
0.14 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section stranded min.
0.14 mm²
Conductor cross section stranded max.
2.5 mm²
Conductor cross section AWG/kcmil min.
26
Conductor cross section AWG/kcmil max
14
General data
Width
6.2 mm
Height
80 mm
Depth
94 mm
Ambient temperature (operation)
-25 °C ... 60 °C
Ambient temperature (storage/transport)
-25 °C ... 70 °C
Mounting position
Any
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 2 / 6
Aug 24, 2011
PLC-OPIT- 24DC/ 48DC/100/SEN Order No.: 2900358
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900358
Assembly instructions
In rows with zero spacing
Operating mode
100% operating factor
Inflammability class acc. to UL 94
V0
Pollution degree
2
Surge voltage category
III
Certificates / Approvals
Certification
CUL, CUL Listed, UL, UL Listed
Accessories
Item
Designation
Description
0801762
NS 35/ 7,5 CU UNPERF
2000MM
DIN rail, material: Copper, unperforated, height 7.5 mm, width 35
mm, length: 2 m
0801733
NS 35/ 7,5 PERF 2000MM
DIN rail, material: steel galvanized and passivated with a thick
layer, perforated, height 7.5 mm, width 35 mm, length: 2000 mm
0801681
NS 35/ 7,5 UNPERF 2000MM
DIN rail, material: Steel, unperforated, height 7.5 mm, width 35
mm, length: 2 m
0801377
NS 35/ 7,5 V2A UNPERF
2000MM
DIN rail, Width: 35 mm, Height: 7.5 mm, Length: 2000 mm,
Color: silver
1201756
NS 35/15 AL UNPERF 2000MM
DIN rail, deep drawn, high profile, unperforated, 1.5 mm thick,
material: aluminum, height 15 mm, width 35 mm, length 2000 mm
1201895
NS 35/15 CU UNPERF 2000MM
DIN rail, material: Copper, unperforated, 1.5 mm thick, height 15
mm, width 35 mm, length: 2 m
1201730
NS 35/15 PERF 2000MM
DIN rail, material: steel galvanized and passivated with a thick
layer, perforated, height 15 mm, width 35 mm, length: 2000 mm
1201714
NS 35/15 UNPERF 2000MM
DIN rail, material: Steel, unperforated, height 15 mm, width 35
mm, length: 2 m
1201798
NS 35/15-2,3 UNPERF 2000MM
DIN rail, material: Steel, unperforated, 2.3 mm thick, height 15
mm, width 35 mm, length: 2 m
2966841
PLC-ATP BK
Separating plate, 2 mm thick, required at the start and end of a
PLC terminal strip. Furthermore, it is used for: visual separation
of groups, safe isolation of different voltages of neighboring PLC
relays in acc. with DIN VDE 0106-101, isolation
Assembly
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 3 / 6
Aug 24, 2011
PLC-OPIT- 24DC/ 48DC/100/SEN Order No.: 2900358
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900358
Bridges
2966812
FBST 6-PLC BU
Single plug-in bridge, Length: 6 mm, Number of positions: 2,
Color: blue
2966825
FBST 6-PLC GY
Single plug-in bridge, Length: 6 mm, Number of positions: 2,
Color: gray
2966236
FBST 6-PLC RD
Single plug-in bridge, Length: 6 mm, Number of positions: 2,
Color: red
2967688
FBST 8-PLC GY
Single plug-in bridge, Length: 8 mm, Number of positions: 2,
Color: gray
2966692
FBST 500-PLC BU
Continuous plug-in bridge, Length: 500 mm, Color: blue
2966838
FBST 500-PLC GY
Continuous plug-in bridge, Length: 500 mm, Color: gray
2966786
FBST 500-PLC RD
Continuous plug-in bridge, Length: 500 mm, Color: red
2966618
OPT-24DC/ 48DC/100
Pluggable miniature optocouplers, input optocouplers, input: 24 V
DC, output: 3 - 48 V DC/ 100 mA
2900262
PLC-BPIT- 24DC/ 1/SEN
6.2 mm PLC sensor basic terminal blocks with Push-In connection
method, input voltage of 24 V DC (without relay or optocoupler)
2966508
PLC-ESK GY
Power terminal block, for the input of up to four potentials, for
mounting on NS 35/7.5
2296087
PLC-V8/D15B/IN
V8-INPUT adapter for eight 6.2 mm PLC interfaces (1 PDT, etc./
see "Additional Products"). 15-pin D-SUB female connector,
control logic: Positive switching
2296074
PLC-V8/D15S/IN
V8-INPUT adapter for eight 6.2 mm PLC interfaces (1 PDT, etc./
see "Additional Products"). 15-pin D-SUB male connector, control
logic: Positive switching
2296553
PLC-V8/FLK14/IN
V8L-INPUT adapter for eight 6.2 mm PLC interfaces (1 PDT,
etc./see "Supplementary Products"). 14-pos. flat-ribbon cable
connection for the PLC system cabling, control logic: Plus
switching
2304115
PLC-V8/FLK14/IN/M
V8L-INPUT adapter for eight 6.2 mm PLC interfaces (1 PDT,
etc./see "Supplementary Products"). 14-pos. flat-ribbon cable
connection for the PLC system cabling, control logic: Minus
switching
1053001
ZB 10:UNBEDRUCKT
Zack strip, unprinted: 10-section, for individual labeling with MPEN, ZB-T or CMS system, sufficient for 100 terminal blocks, for a
terminal width of 10.2 mm, color: White
1053014
ZB10,LGS:FORTL.ZAHLEN
Zack strip, 10-section, printed horizontally: with the numbers,
1-10, 11-20 etc. up to 991-1000, color: white
5060883
ZB10/WH-100:UNBEDRUCKT
Zack strip, unprinted: 10-section, for individual labeling with MPEN, ZB-T or CMS system, large batch, sufficient for labeling
1000 terminal blocks, for a terminal width of 10.2 mm, color: White
General
Marking
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 4 / 6
Aug 24, 2011
PLC-OPIT- 24DC/ 48DC/100/SEN Order No.: 2900358
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900358
Tools
1204517
SZF 1-0,6X3,5
Actuation tool, for ST terminal blocks, also suitable for use as a
bladed screwdriver, size: 0.6 x 3.5 x 100 mm, 2-component grip,
with non-slip grip
Diagrams/Drawings
Circuit diagram
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 5 / 6
Aug 24, 2011
PLC-OPIT- 24DC/ 48DC/100/SEN Order No.: 2900358
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900358
Address
PHOENIX CONTACT Inc., USA
586 Fulling Mill Road
Middletown, PA 17057,USA
Phone (800) 888-7388
Fax (717) 944-1625
http://www.phoenixcon.com
© 2011 Phoenix Contact
Technical modifications reserved;
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 6 / 6
Aug 24, 2011