MEDICAL & MILITARY MI-JOO Mega Series 1 0 - 1 5 0 W AT T S M I L I TA R Y C O T S D C / D C C O N V E R T E R Features • • • • • • • Inputs: 28, 155, 165, to 270VDC Output: 2 to 48VDC High efficiency Remote sense Up to 13.5 watts/cubic inch ZVS/ ZCS power architecture Low noise FM control Selection Table Selection Table INPUT Input Voltage No load power disspation Single Output MI-LJ [a] [b] – [c] [d] 10–50W See table Dual Output MI-PJ [a] [b] [b] – [c] [d] [d] 20–100W Typ 1.35W Triple Output MI-RJ [a] [b] [b] [b] – [c] [d] [d] [d] 30–150W Please substitute selection character (e.g. [a]) with value designator in the appropriate table below. OUTPUT Output Voltage See table Output Power See table Output Ripple 80mV pk-pk typical VNOM RANGE TRANS Load Regulation 0.05% Vnom typical 2 = 28V 18–50V (1) 60V Z=2V Line Regulation 0.05% Vnom typical 5 = 155V 100–210V 230V Current Limit Setting 105%–125% 6 = 270V 125–400V (2) 475V Set Point Accuracy 0.5% Vnom typical 7 = 165V 100–310V (3) Low–High Trim Voltage 50%–110% Total Remote Sense Compensation 0.5V A = INPUT VOLTAGE B = OUTPUT VOLTAGE M = 10V J = 36V Y= 3.3V 1 = 12V K = 40V 0= 5V P = 13.8V 4 = 48V X= 5.2V 2 = 15V V= 5.8V N = 18.5V T = 6.5V 3 = 24V R = 7.5V L = 28V OPERATING C = PRODUCT GRADE D = OUTPUT POWER/CURRENT Efficiency 80%–90% Isolation Input to Output 3,000Vrms Output to Baseplate 500Vrms Input to Baseplate 1,500Vrms ENVIRONMENTAL Cooling External cooling may be required, consult sales office. M = -55°C to +100°C V out ⭓5V V out <5V A = 10W – Z = 25W Z = 5A Y = 50W Y = 10A Refer to MI-J00 1 Up: 65.5x63.5x15.7mm 2 Up: 65.5x124.4x15.7mm 3 Up: 65.5x185.4x15.7mm For Technical Illustration refer to page 375 in Module Section MECHANICAL Dimensions I = -40°C to +100°C JUNIOR SIZE MODULE Note :(1) 16V operation at 75% load. (2) These units rated at 75% load from 125-150Vin: 5 Vout @ 50W, 2V and 3.3 V @ 10A (3) For use with Vicor‘s MI-AIM STANDARDS AND APPROVALS Safety standards JUNIOR SIZE Your dependable power partner – www.powerbox.com.au 373