POWERBOX MI-J6M-IY

MEDICAL & MILITARY
MI-JOO Series
1 0 - 5 0 W AT T S M I L I TA R Y C O T S D C / D C C O N V E R T E R
Features
•
•
•
•
•
•
28Vdc and 270Vdc Inputs per MIL-STD-704D/E/F
155Vdc inputs per MIL-STD-1399A
MIL-STD-810 environments
Up to 23 W/in3
80-90% Efficiency
Remote sense and current limit
Specifications
STANDARDS AND APPROVALS
INPUT
Environment (MIL-STD-8100)
Input voltage
See input voltage chart
No load power
dissipation
Typ 1.35W
70,000 feet
Humidity – Method 507.2
86/240 (%/hours)
Acceleration – Method 513.3 9 g’s
OUTPUT
Set point accuracy
0.5% V nom typical
Load/Line regulation
0.05% V nom typical
Output temperature drift
0.02%/°C
Output noise
1%pp V nom
Output voltage trimming
50% – 110%
Current limit
105% – 125%
Short circuit current
105% – 130%
Vibration – Method 514.3
20g’s
Shock – Method 516.3
40g’s
Reliability (MIL-HDBK-217F)
Remote sense compensation 0.5 V
OPERATING
25°C Ground benign
3,619,000 hours
50°C Naval sheltered
2,208,000 hours
65°C Airborne inhabited
cargo
1,701,000 hours
Environmental compliance
MIL-STD-810
Derating
NAVMAT P-4855-1A
MECHANICAL
Isolation
Input to Output 3,000Vrms
Output to Baseplate 500Vrms
Input to Baseplate 1,500Vrms
Efficiency
80 – 90%
ENVIRONMENTAL
Storage temperature
Altitude – Method 500.2
Weight
85 grams
Dimensions
59.7 x 61.0 x 12.7mm
Selection Table
I Grade
M Grade
-55°C to +125°C
-65°C to +125°C
MI-J[A][B]-[C][D]
A = INPUT VOLTAGE
B = OUTPUT VOLTAGE
Operating temperature
(baseplate)
-40°C to +100°C
-55°C to +100°C
18–50V (1)
60V
Z=2V
Power cycling burn-in
12hrs 25 cycles
96hrs 200 cycles
5= 155V 100–210V
230V
Y= 3.3V
Temperature cycled with
power off
48 hrs, 12 cycles
65°C to +100°C
48hrs, 12 cycles -65°C to +100°C
6= 270V 125–400V (2)
475V
0= 5V
M = 10V
3 = 24V
Test data supplied at these
temperature
X= 5.2V
1 = 12V
L = 28V
-40°C to +80°C
-55°C to +80°C
VNOM
RANGE
2= 28V
TRANS.
7= 165V 100–310V
T = 6.5V
V= 5.8V P = 13.8V
C = PRODUCT GRADE
I= -40°C to +100°C
M=-55°C to +100°C
K = 40V
J = 36V
D = OUTPUT POWER/CURRENT
⭓5V
For Technical Illustration refer to page 230 in Module Section
2 = 15V
R = 7.5V N = 18.5V J = 48V
<5V
A= 10W
Z=25W
5A
Y=50W
10A
Note :(1) 16V operation at 75% load (2) These units rated at 75% load from
125-150Vin: MI-26Z-XV, MI-26Y-XV, MI-260-XW.
Your dependable power partner – www.powerbox.com.au
371