MEDER MK06-7-B

MK06 Series
MEDER electronic
Reed Sensors for
PCB Mounting
DESCRIPTION
MK06 sensors are magnetically operated Reed
proximity switches for direct PCB mounting. The
sensor should be mounted on a fixed surface
with the actuating magnet on the moving surface.
Introduction or removal of the magnetic field
determines the closing and opening of the Reed
Switch. (2.54 mm PCB pin spacing, available with
different distances)
APPLICATIONS
• Telecommunications
Telephone hook switch, keyboard applications
• Domestic appliances
Door switch for washing machines, dishwashers,
microwave ovens, baking ovens, refrigerators
• Limit switch for low-power signals
Garage door controls, lever hoists, conveyors
• Lifts / elevators
Position indicators
FEATURES
•
•
•
•
Form A, B, C and E (Latching) available
High power switches available
Various case sizes available
Five operate sensitivities available
ORDER INFORMATION
MAGNETIC SENSITIVITY
Series
Packaging Size
Magnetic
Sensitivity
Sensitivity
Class
Pull In
AT Range
MK06 - 10
X-
X
B
10 - 15
4
B, C, D, E
C, H
15 - 20
5
B, C
D, I
20 - 25
6
B, C, D, E
E, K
25 - 30
7
B, C, D, E
8 (Form A)
B, C, D, E
8 (Form B)
H, I, K
Options
Part Number Example
MK06 - 4 - C
Series
Contact
Form
MK06 - 10
X*
4 is the packaging size
C is the magnetic sensitivity
Part Number Example
B
Options
MK06 - 10 - E
E
E selects the latching option
* See footnote on following page.
www.meder.com
226
MEDER electronic
MK06 Series
Reed Sensors for
PCB Mounting
DIMENSIONS
All dimensions in mm [inch]
* MK6-10-E is a magnetic latching sensor which is opened or closed by a passing magnet and remains in that
state until a magnet of opposite polarity or direction passes by again. The E refers to a latching sensor and does
not represent the magnetic sensitivity.
MK6-10-B is a normally closed sensor. The B refers to a latching sensor and does not represent the magnetic
sensitivity.
www.meder.com
227
MEDER electronic
MK06 Series
Reed Sensors for
PCB Mounting
CONTACT DATA
All Data at 20° C
Switch Model →
Contact Form →
Packing Style →
Contact Ratings
Conditions
Switch 66
Form A, B, C
6, 7, 8, 10
Min.
Typ.
Max.
Switch 80
Form A
4
Min.
Typ.
Max. Units
Switching Power
Any DC combination of V & A not
to exceed their individual max.‘s
10
10
W
Switching Voltage
DC or peak AC
200
170
V
Switching Current
DC or peak AC
0.5
0.5
A
Carry Current
DC or peak AC
1.25
0.5
A
Static Contact Resistance
w/ 0.5 V & 10mA
150
200
mΩ
Dynamic Contact Resistance
Measured w/ 0.5 V & 50mA ,
1.5 ms after closure
200
250
mΩ
Insulation Resistance across
Contacts
100 volts applied
1010 *
109
Ω
Breakdown Voltage across
Contact
Voltage applied for 60 sec. min.
225 *
210
VDC
Operate Time incl. Bounce
Measured w/ 100 % overdrive
0.5
0.6
ms
Release Time
Measured w/ no coil suppression
0.1
0.1
ms
Capacitance
at 10 kHz cross contact
0.2
0.2
pF
Contact Operation **
Must Operate Condition
Steady state field
10
30
10
30
AT
Must Release Condition
Steady state field
4
27
4
27
AT
Environmental Data
Shock Resistance
1/2 sinus wave duration 11 ms
50
50
g
Vibration Resistance
From 10 - 2000 Hz
20
20
g
Ambient Temperature
10°C/ minute max. allowable
-20
85
-20
85
o
C
Stock Temperature
10°C/ minute max. allowable
-35
85
-35
85
o
C
Soldering Temperature
5 sec.
260
o
C
260
Please note: The indicated electrical data are maximum values and can vary downwards when using a more sensitive switch.
* Insulation resistance of 1012 and breakdown voltage of 480 VDC is available.
** These ranges refer to the uncut / unmodified Reed Switches described in our Reed Switch section. Consult factory if more
detail is required.
www.meder.com
228
MK06 Series
MEDER electronic
Reed Sensors for
PCB Mounting
CONTACT DATA
Switch Model →
Contact Form →
Packing Style →
All Data at 20° C
Contact Ratings
Conditions
Switch 87
Form A
5
Min.
Typ.
Switch 90
Form C
8
Max.
Min.
Typ.
Max. Units
Switching Power
Any DC combination of V & A not
to exceed their individual max.‘s
10
20
W
Switching Voltage
DC or peak AC
200
175
V
Switching Current
DC or peak AC
0.5
0.5
A
Carry Current
DC or peak AC
0.5
1.0
A
Static Contact Resistance
w/ 0.5 V & 10mA
200
150
mΩ
Dynamic Contact Resistance
Measured w/ 0.5 V & 50mA ,
1.5 ms after closure
200
250
mΩ
Insulation Resistance across
Contacts
100 volts applied
109
109
Ω
Breakdown Voltage across
Contact
Voltage applied for 60 sec. min.
100
200
VDC
Operate Time incl. Bounce
Measured w/ 100 % overdrive
0.6
0.7
ms
Release Time
Measured w/ no coil suppression
0.1
1.5
ms
Capacitance
at 10 kHz cross contact
0.2
1.0
pF
Contact Operation **
Must Operate Condition
Steady state field
10
30
Must Release Condition
Steady state field
4
27
15
40
AT
AT
Environmental Data
Shock Resistance
1/2 sinus wave duration 11 ms
50
50
Vibration Resistance
From 10 - 2000 Hz
20
20
Ambient Temperature
10°C/ minute max. allowable
-20
85
-20
Stock Temperature
10°C/ minute max. allowable
-35
85
-35
Soldering Temperature
5 sec.
260
g
g
85
o
C
85
o
C
260
o
C
Please note: The indicated electrical data are maximum values and can vary downwards when using a more sensitive switch.
* Insulation resistance of 1012 and breakdown voltage of 480 VDC is available.
** These ranges refer to the uncut / unmodified Reed Switches described in our Reed Switch section. Consult factory if more
detail is required.
www.meder.com
229