ETC MLX90247C

MLX90247C
Thermopile w/NTC Thermistor
Features and Benefits
Solid state sensor
High reliability
Low cost, small size
On chip temperature sensor
Applications
Non-Contact Temperature Sensing
Differential Temperature Sensing
Climate Control
Ear, Temple Thermometers
Household and Commercial Appliances
Ordering Information
Part No.
MLX90247C
Description
Thermopile with 100K NTC Thermistor
Functional Diagram
Description
The MLX90247C is a thermopile sensor IC which
detects very small amounts of heat radiation. The
sensor consists of a membrane with a thermopile on
top of it.
The hot junctions of the thermopile are positioned
near the center of the membrane, the cold junctions
above the bulk silicon edge.
Due to the low thermal conductivity of the
membrane, absorbed heat will cause the
temperature to increase more at the center of the
membrane than at the edge above the bulk. This
temperature difference is converted to an electric
potential by the thermo-electric effect in the
thermopile junctions. No supply voltage is needed.
The sensor IC is packaged together with a NTC chip
thermistor for cold junction reference. The
thermopile and thermistor are separate components,
mounted in close proximity. The NTC thermistors
have higher sensitivity at low temperatures than the
standard PTC thermistors in the B and D models.
ϑ −
The sensor and thermistor can be used independent
of each other if desired, as the thermopile potential
is floating.
MLX90247C Discrete Infrared Sensor IC
Page 1
Rev 1.0 17/Feb/01
MLX90247C
Thermopile w/NTC Thermistor
MLX90247C Electrical Specifications
o
o
DC Operating Parameters TA = -40 C to 150 C, (unless otherwise specified)
Parameter
Thermopile Resistance
Symbol
Rtp
Sensitivity
S
TC of Sensitivity
Time constant
Thermistor Value
Thermal Coefficient NTC (1)
TCs
T
Rntc
βntc
Test Condition
@298K
sensor @298K
black body @299K
@298K
@298K
0-50°C (1)
Min
44
Typ
59.5
Max
75
Unit
kΩ
29
42
55
µV/K
30
105
4161
%/K
ms
kΩ
K
0.1
95
4120
100
4140
(1) Tolerance given between 15°C and 35°C. Typical value corresponds to a relative resistance change of
–4.68%/°C. Definition of β is ∆lnR/∆(1/T) with T in K. (Naperian logarithm).
Note: when measuring resistances with an ohm meter, please take care that the internal protection diodes,
as indicated in the functional diagram below, are always reverse biased.
ϑ −
MLX90247C Absolute Maximum Ratings
Parameter
Operating temperature
Storage temperature
Soldering temperature
Value
-40 ~ 150
-40 ~ 150
<220
MLX90247C Discrete Infrared Sensor IC
Unit
°C
°C
°C
Page 2
Comment
Keep diode leakage in mind at high temperatures
t<5sec
Rev 1.0 17/Feb/01
MLX90247C
Thermopile w/NTC Thermistor
MLX90247C Pinout
Pin
1
2
3
4
Symbol
OutIr+
Rsens
OutIrVss
Description
Infrared Thermopile positive output
Thermistor for sensor ambient temperature measurement
Infrared Thermopile negative output
Thermistor ground / case potential
TO-39 package - connections
1
2
4
3
Top view = pins down
ML90247C Mechanical Specifications
Parameter
TO-39 specifications
Metal cap
Filling gas
Filter specifications
Transmission
Transmission
Sensor window
FOV
Aperture diameter
Value
Unit
Comment
Welded
Nitrogen
>75
<0.5
%
%
7.5µ < λ <13.5µ
0 < λ < 5µ
100
3.5
°
mm
Full opening angle: Determined by aperture
Default
ESD Precautions Electronic semiconductor products are sensitive to Electro Static Discharge (ESD). Always observe
ESD control procedures whenever handling semiconductor devices.
Disclaimer Melexis reserves the right to periodically make modifications to product specifications. The information
included herein is believed to be accurate and reliable. However, Melexis assumes no responsibility for its use; nor for
any infringements of patents or other rights of third parties which may result from it’s use.
MLX90247C Discrete Infrared Sensor IC
Page 3
Rev 1.0 17/Feb/01
MLX90247C
Thermopile w/NTC Thermistor
RA (TO-39) Package Outline
For the latest version of this document,
Go to our website at:
France
Melexis France
Tour Arago, 5 rue Bellini, 92806 Puteaux-La-Défense, France.
Phone: +33 1 47 78 11 34
Fax: +33 1 47 78 06 35
E-mail: [email protected]
www.melexis.com
Or for additional information
contact Melexis Direct:
Italy
Dimacred IRL
Via Papa Giovanni XXIII no. 25, 20046 Biassono, Italy
Phone: +39 039 249 4856
Fax: +39 039 491773
E-mail: [email protected]
USA
Melexis Inc.
41 Locke Road, Concord, NH 03301
Phone: +1 603 223 2362
E-mail: [email protected]
Fax: +1 603 223 9614
Japan
Thermopile Japan Co., LTD
3-48-10 Ogikubo, Suginami-ku, Tokyo
Phone: +81 3 3392 6961
E-mail: [email protected]
United Kingdom
Silicon Concepts
PCB Lynchborough Road, Hampshire GU30 7SB, United Kingdom
Phone: +44 1428 751 617
Fax: +44 1428 751 603
E-mail: [email protected]
Taiwan
Beechwood Int’l Taiwan Co.
Room 8, 17F, No. 189, Taipei, Taiwan
Phone: +886 2 2739 3322
E-mail: [email protected]
Germany
Schiess-strasse 55, 40549 Düsseldorf, Germany
Phone: +49 211 5360212
Fax: +49 211 5360250
E-mail: [email protected]
MLX90247C Discrete Infrared Sensor IC
Fax: +81 3 3392 6901
Page 4
Fax: +886 2 2739 3090
Rev 1.0 17/Feb/01