MICREL MLX90601B

MLX90601B
Datasheet
Analog IR thermometer module
Features
•
•
•
•
•
•
Remote temperature measurement
Fully linearised signals
Analog voltage output
Factory calibrated
EEprom ECC
Open drain relay driver output
Applications
•
•
•
•
Automotive climate control
Toasters, microwave ovens and other appliances that require temperature control
Residential, commercial climate control and occupancy detection
Industrial temperature transducer and monitoring applications
Ordering Information
M
L
X
9
0
6
0
1
E
Z
A
Temperature
Suffix
Product Code
B
Type
X
X
Version
Package
Suffix
Supply, i/o-Configuration
and temperature ranges
Part No
MLX90601
MLX90601
Suffix
Package
ZA
ZA
Temperature
E
E
Type
B
B
Version
AA
BA
Functional Diagram
IR+
IRRsens
VSS
IRINP
VDD
5V
C3
TINP
IROUT
TINN
IROUT
R1D
MLX90247
C6
TEMPOUT
MLX90313
REL1
VSS
TEMPOUT
R1C
C7
REL1
R3
VSS/GND
390109060101
Rev. 004
Analog voltage output
C
SPI serial interface
D
PWM output
Description
8 bit Analog –20/120°C 5V supply
8 bit Analog 5/60°C 5V supply
Description
IRINN
CREF
B
The MLX90601B is a versatile IR thermometer
module, which performs signal conditioning,
linearisation
and
ambient
temperature
compensation. The module is built around the
MLX90313 IR sensor interface, which uses high
performance chopper stabilized amplifiers,
providing excellent noise performance. The
sensing element is the MLX90247 discrete IR
thermopile.
The module is delivered factory calibrated. The
output is an absolute analog voltage output for
both sensor ambient temperature and the object
temperature. The REL1 output is the open drain
relay driver output available in MLX90313.
Page 1 of 8
Dec/01
MLX90601B
Datasheet
Analog IR thermometer module
ELECTRICAL CHARACTERISTICS
Parameter
Symbol
Regulator and consumption
Supply voltage range
Vin
Supply current
Idd
POR threshold voltage
Vpor
IR-chain amplifier and output driver
Power supply rejection
PSSR
ratio
Input referred white noise
Vnir
Chopper frequency
fc
Output voltage range
Output source current
Iod
Output sink current
Ios
DC Output impedance,
rod
drive
DC Output impedance,
ros
sink
Amplifier bandwidth
BW
Temp-chain amplifier and output driver
Power supply rejection
PSSR
ratio
Input referred white noise
Vntemp
Chopper frequency
fc
Output voltage range
ORtemp
Output source current
Iod
Output sink current
Ios
AC Output impedance
ro
Amplifier bandwidth
BW
Rel1 open drain relay driver
High voltage protections
output impedance
Ro
ADC
Resolution
Monotonicity
Differential non-linearity
DNL
Integral non-linearity
INL
Gain error
Total input-referred noise
DAC
Resolution
Monotonicity
Differential non-linearity
Integral non-linearity
390109060101
Rev. 004
Test Condition
Min
Typ
Max
Unit
VDD
@ Ta=25°C
4.5
5
5
1.3
6
5.6
1.5
V
mA
V
1.1
f ≤ 100kHz
75
dB
rms-value
25
10
nV/√Hz
kHz
V
mA
uA
Ω
100
Ω
8
IROUT
IROUT
IROUT
IROUT
0
1
20
Vdd-0.2
IROUT
500
f ≤ 100kHz
Hz
75
dB
rms-value
400
500
nV/√Hz
kHz
V
mA
uA
Ω
Hz
10
V
Ω
15
TEMPOUT
TEMPOUT
TEMPOUT
TEMPOUT
0
1
20
Vdd-0.2
100
32
full scale
Vref=3V
12
bit
guaranteed by design
0.4
LSB
½
LSB
1
LSB
0.2
LSB
8
bit
guaranteed by design
½
LSB
½
LSB
DNL
INL
Page 2 of 8
Dec/01
MLX90601B
Datasheet
Analog IR thermometer module
General Description
Absolute Maximum Ratings
MLX90601 is a versatile IR thermometer built
around the MLX90247 Discrete IR thermopile
sensor with on-chip PTC and the MLX90313
Programmable IR sensor interface.
MLX90313 amplifies the signals coming from
MLX90247 and converts them to digital by
means of two high performance, low noise,
chopper stabilized amplifiers and the 12-bit
analog to digital converter. The digital unit on
the interface then performs the ambient
compensation of the IR signal. This results in
two temperature signals, one representing the
temperature of the object the IR sensor is
pointed at (Tobject) and one representing the
temperature of the sensor (Tambient). Both
signals are then linearised and presented at the
outputs (Tobject is present at pin IROUT,
Tambient is present at pin TEMPOUT) by means
of the 8 bit digital to analog converter.
The REL1 output is directly connected to the
open drain relay driver output of MLX90313.
This output is switched by means of a factory
programmable comparator.
Supply Voltage, VDD (overvoltage)
80V
Supply Voltage, VDD (operating)
4.5V - 6V
Reverse Voltage Protection
-5V
Supply Current, IDD @25°C
6 mA
Output Current, IOUT
mA
Operating Temperature Range, TA
-40°C - 125°C
Storage Temperature Range, TS
-55°C - 150°C
ESD Sensitivity
4kV
Pinout
Pin
1
2
3
4
Symbol
IROUT
TEMPOUT
VDD
REL1
5
VSS
Description
Object temperature output
Ambient temperature output
Supply pin
Open drain, relay driver
comparator output
Ground
Unique Features
MLX90601 is an automotive grade IR
thermometer that can be fitted to any contactless
temperature measurement application by means
of the programmable interface. The module is
designed to cope with all standard qualification
tests oriented towards the harsh automotive
environment.
If so desired, all temperature ranges and
comparator settings can be adapted to the
application.
MLX90601 is delivered calibrated, relieving the
customer of IR calibration.
390109060101
Rev. 004
Page 3 of 8
Dec/01
MLX90601B
Datasheet
Analog IR thermometer module
Supply
Linearisation proceeds in two steps. In the first
step the ambient temperature is calculated from
the measured signal coming from the on-chip
PTC temperature sensor of MLX90247. The
value is stored in a dedicated register,
controlling the output electronics.
The module should be supplied directly with a
nominal 5V regulated supply on pin VDD. (4.5V
– 6V)
The power-on reset circuitry is internal to
MLX90313. The module is fully operational 16
ms from the time the supply crosses 1.3V. The
POR circuit will issue another reset if the supply
voltage goes below 1.3V.
In the second step the value of the ambient
temperature is combined with the measured
signal coming from the IR thermopile sensor
inside MLX90247 to obtain a calculated value for
the object temperature, based on the calibration
data. The value is stored in a dedicated register
and from there available for the output
electronics.
Detailed Description
Analog Features
A/D
The MLX90313 on the module contains a 12-bit
analog to digital converter. True 12-bit
conversion is achieved by a fully differential
analog part of the converter. Automatic
calibration is implemented in the background,
which allows precise conversion in a very wide
temperature range.
D/A
An 8-bit digital to analog converter is used to
output the data for the linearised Tobject- and
Tambient signals.
Output drivers
The IROUT and TEMPOUT pin drivers can
source 1mA and sink 20µA and are reverse
voltage protected down to –5V relative to VSS.
REL1 is an open drain relay driver output
controlled by the comparator circuitry of
MLX90313. The digital comparator’s threshold
(25°C) and hysteresis (2°C) are preset from
factory. The comparator uses Tobject as input
signal.
Linearisation Unit
The linearisation unit of MLX90313 realizes 3
functions:
1. Offset measurement and calibration (offset
drift compensation)
2. Measurement and offset cancellation
3. Linearisation.
390109060101
Rev. 004
Note that on request any arbitrary linearisation
curve can programmed. A very wide range of
applications can be covered by MLX90601
family.
Sensor Characteristics
For detailed specification we refer to the
datasheet on MLX90247, available from the
Melexis website.
In a calibrated module the linearisation unit of
MLX90313 takes all characteristics of the sensor
into account, including all process variations
they are subject to.
The TO-39 sensor housing of the thermopile has
a 2.5mm diameter aperture, resulting in a 70° full
angle field of view.
The silicon filter used as IR-window is treated
with an antireflective coating that will pass
minimum 75% of IR radiation in the wave length
band from 7.5µm to 13.5µm. Below 5µm, 99.5%
of incoming radiation is reflected by the filter.
Pin Descriptions
IROUT
IRout analog voltage output pin. The voltage at
this pin is a linear representation of Tobject, the
temperature of the object the IR sensor is
pointed at. The driver can source at least 1mA
and sink at least 20µA to/from an external load.
TEMPOUT
Tempout analog voltage output pin. The voltage
Page 4 of 8
Dec/01
MLX90601B
Datasheet
Analog IR thermometer module
at this pin is a linear representation of Tambient,
the temperature of the IR sensor, as measured
by the PTC inside MLX90247. The driver can
source at least 1mA and sink at least 20µA
to/from an external load.
The comparator is a digital comparator, with a
resolution of 12 bits. By default the input polarity
is inverting. Threshold and hyteresis values are
version dependent, as indicated below. These
settings can be changed by factory programming
on request.
VDD: Supply pin
default REL1 settings
Version
Threshold
Hysteresis
5/60°C version
25°C
±2°C
-20/120°C version
50°C
±5°C
REL1
Open drain relay driver output. The typical onresistance of this driver is <10Ω with a supply
voltage of VDD=5V.
VSS: Supply pin
REL1
Tobject
COMP
Threshold in
EEPROM
VSS
Hysteresis
in EEPROM
390109060101
Rev. 004
Page 5 of 8
Dec/01
MLX90601B
Datasheet
Analog IR thermometer module
Applications Information
Connection of the MLX90601 module into an application is straightforward. The 5V regulated supply
should be connected between pin 3 (VDD) and pin 5 (VSS).
The outputs can be measured relative to VSS at pin 1 (IROUT) for Tobject and pin 2 (TEMPOUT) for
Tambient, e.g. by means of a voltmeter. In an actual application the module outputs can be directly
connected to the A/D inputs of a microcontroller, e.g. as a replacement for a conventional temperature
sensor.
In many applications, the ambient temperature of the sensor is not needed. In this case, pin 2 can simply
be left open.
The REL1 signal at pin 4 can be used as input for a digital I/O or to drive a relay (not shown).
IR sensor
IR+
IRINP
IR-
IRINN
Rsens
TINP
VSS
TINN
TEMPOUT
Ta
Thermisto
r
Application
Microcontroller
MLX90313
OPA
A/D
2
A/D input (optional)
D/A
Digital
IROUT
To
OPA
A/D
1
A/D input
D/A
Ta
MLX90247
12
4
REL1
COMP
Digital input
EEprom, Control and Support Blocks
3
VDD
CREF
5V
5
VSS
VSS
MLX90601B
Output waveforms
IROUT output voltage
versus
Object Temperature
4.5
TEMPOUT output voltage
versus
Ambient Temperature MLX90601EZA BBA
MLX90601EZA BBA
4.5
4
Output Voltage TEMPOUT (V)
Output Voltage IROUT (V)
4
3.5
3
2.5
2
1.5
1
0.5
3.5
3
2.5
2
1.5
1
0.5
0
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
Object Temperature To (degC)
390109060101
Rev. 004
-5
0
5
10
15
20
25
30
35
40
45
50
55
60
Ambient Temperature Ta (degC)
Page 6 of 8
Dec/01
MLX90601B
Datasheet
Analog IR thermometer module
Glossary of Terms
ESD Precautions
Electronic semiconductor products are sensitive
to Electro Static Discharge (ESD).
Always observe Electro Static Discharge control
procedures whenever handling semiconductor
products.
FAQ
Q: What is the accuracy?
A: For an object temperature range between
5°C and 60°C the accuracy of measurement
is ±1°C. For the wider object temperature
range version (-20°C/120°C) the accuracy of
measurement is ±2°C.
Q: What is FOV?
A: The FOV or Field Of View is a definition of
the area the sensor is ‘seeing’. The sensor
will detect radiation coming in at angles,
relative to the sensor’s central axis, from 0° to
35°C. The full viewing angle is thus 70°.
Q: What is the useful temperature range?
A: There are two temperature ranges of interest;
the temperature of the object (or target),
which you are trying to measure and the
temperature of the sensor. The sensor
temperature, called Tambient, should be
between 0°C and 50°C. Outside this range
the ambient temperature compensation will
no longer work and calculation of the object’s
temperature will no longer be correct. The
TEMPOUT output will saturate under this
condition. The object temperature, called
Tobject, should be between 5°C and 60°C.
(-20°C/120°C for wide range version)
Outside this range the IROUT output will
saturate.
Q: Can the temperature ranges be changed?
A: Yes, MLX90313 is a programmable device.
Melexis selected a limited set of standard
ranges that will fit the majority of applications
in order to limit delivery times. However, if
necessary, the ranges can be adapted for
any particular application. Contact your sales
representative for more information.
390109060101
Rev. 004
ADC: Analog to Digital Converter
Ambient Compensation: The IR signal captured
by a thermopile sensor is not only dependent
on the temperature of the object (Tobject) but
also on the temperature of the sensor itself.
Therefore the IR signal is compensated for
this effect by means of the measured sensor
temperature (Tambient). This rather complex
calculation is performed in the linearisation
unit of MLX90313.
Chopper Amplifier: Special amplifier
configuration aimed at ultra low offset.
DAC: Digital to Analog Converter.
EEprom: Non-volatile memory that can be
electrically erased and rewritten. This type of
memory is used to store configuration and
calibration data for the module.
ECC: Error Checking and Correction. The
EEprom on board of MLX90313 is equipped
with a checking and correction feature based
on the Hamming Code method.
IR: Infrared. Every object emits infrared
radiation in relation to its temperature. This
effect can be used to measure this
temperature without the need for physical
contact.
Linearisation: The signal from a thermopile is not
linear with the object temperature.
MLX90313 is therefore equipped with a
digital calculation unit that produces an
output that is linear with the object
temperature.
POR: Power-on reset: Reset circuit that starts
the digital system in a known state whenever
the supply voltage is cycled
PSSR: Power Supply Rejection Ratio: Measure
for an amplifier’s immunity to disturbances on
the supply connections.
PTC: See Thermistor
Ta, Tambient: The temperature of the IR sensor.
Target: or Object: The object the IR module is
aimed at.
Thermistor: Temperature dependant resistor.
Basically there are 2 types. The types that
increase their resistance with rising
temperature are PTC (positive thermal
coefficient) type. The ones that decrease
their resistance with rising temperature we
call NTC (negative thermal coefficient) type.
The MLX90313 can work with both types.
The MLX90601 modules are equipped with
sensors that use PTCs.
To, Tobject: The temperature of the object one
wishes to measure with the module
Page 7 of 8
Dec/01
MLX90601B
Datasheet
Analog IR thermometer module
assumes no responsibility for its use; nor for any
infringements of patents or other rights of third
parties, which may result from its use.
Disclaimer
Melexis reserves the right to periodically make
modifications to product specifications. The
information included herein is believed to be
accurate and reliable. However, Melexis
Physical Characteristics
For the latest version of this document, go to our website at:
www.melexis.com
Or for additional information contact Melexis Direct:
Europe and Japan:
Phone: +32 13 61 16 31
E-mail: [email protected]
390109060101
Rev. 004
All other locations:
Phone: +1 603 223 2362
E-mail: [email protected]
Page 8 of 8
Dec/01