PHOENIX 2982650

OV-24DC …
Solid-State Relays
INTERFACE
Data Sheet
103082_01_en
© PHOENIX CONTACT - 11/2006
Description
OV-24DC … solid-state relays for electrical isolation can be
mounted directly on the PCB as interfaces or plugged in
using the SIM-AMS socket, which can be soldered.
The solid-state relays are suitable for switching ohmic,
capacitive or inductive loads. Relays for switching AC
circuits have a zero point switch to switch on loads that are
in the zero voltage crossing. They are switched off in the
zero current crossing.
DC loads can switch up to 1 A at 350 V DC and up to 4 A at
60 V DC, while AC loads can switch up to 5 A at 480 V AC.
Inductive loads must be provided with an appropriate
protective circuit (e.g., free-wheeling diode or RC element).
The electronic load relays have the following advantages:
– No wear, even at high switching frequencies
– No contact bounce – no movable parts
– No electromagnetic interference
– Electrically insulated housing
– Compact dimensions
– High test voltage of up to 4 kV between control and load
circuits
Make sure you always use the latest documentation.
It can be downloaded at www.download.phoenixcontact.com.
A conversion table is available on the Internet at
www.download.phoenixcontact.com/general/7000_en_00.pdf.
This data sheet is valid for all products listed on the following page:
OV-24DC …
Ordering Data
Solid-State Relays With DC Voltage Output
Description
Type
Order No.
Pcs./Pck.
Solid-state relay, for signal amplification and electrical isolation of the control
and load circuits, can be plugged into the SIM-AMS plug-in base, which can
be soldered, or mounted directly on the PCB with PCB connection,
input/output: DC voltage (350 V DC, maximum)
OV-24DC/350DC/1
2982634
10
Solid-state relay, for signal amplification and electrical isolation of the control
and load circuits, can be plugged into the SIM-AMS plug-in base, which can
be soldered, or mounted directly on the PCB with PCB connection,
input/output: DC voltage (60 V DC, maximum)
OV-24DC/ 60DC/4
2982647
10
Solid-State Relays With AC Voltage Output
Description
Type
Order No.
Pcs./Pck.
OV-24DC/480AC/5
2982650
10
Accessories
Description
Type
Order No.
Pcs./Pck.
Plug-in base
SIM-AMS ...
See INTERFACE catalog
Solid-state relay, for signal amplification and electrical isolation of the control
and load circuits, can be plugged into the SIM-AMS plug-in base, which can
be soldered, or mounted directly on the PCB with PCB connection,
input: DC voltage/output: AC voltage
Technical Data
Input Data
Nominal input voltage UN
...350DC/1
...60DC/4
24 V DC
24 V DC
Operating voltage range
...480AC/5
24 V DC
4.25 V DC ... 32 V DC
4 V DC ... 32 V DC
Voltage switching threshold
"0" signal
"1" signal
Typical input current at UN
< 1 V DC
> 3.3 V DC
< 1 V DC
> 3.3 V DC
< 1.2 V DC
> 3.5 V DC
15 mA
15 mA
10 mA
Typical switch-on time
< 100 µs
< 100 µs
1/2 period, maximum
Typical switch-off time
< 250 µs
< 250 µs
1/2 period, maximum
100 Hz
100 Hz
25 Hz
Switching frequency for ohmic nominal load
Output Data
Nominal output voltage range
Periodic peak reverse voltage
Limiting continuous current (see derating curves)
Minimum load current
Surge current
Voltage drop at maximum limiting continuous current (2-wire)
Maximum load value I2t
Leakage current when switched off
Maximum phase shift (inductive loads)
Protective circuit
103082_01_en
...350DC/1
...60DC/4
...480AC/5
1 V DC ... 350 V DC
1 V DC ... 60 V DC
12 V AC ... 530 V AC
1000 V
–
–
1A
4A
5A
1 mA
1 mA
20 mA
20 A (tp = 1 s)
25 A (tp = 1 s)
80 A (tp = 20 ms)
0.5 V
0.5 V
1.2 V
–
–
50 A2s
100 µA
100 µA
1 mA
–
–
cos ϕ = ≥ 0.5
Diode for protection
Diode for protection
against polarity reversal against polarity reversal
–
PHOENIX CONTACT
2
OV-24DC …
General Data
...350DC/1
...60DC/4
4 kVrms
4 kVrms
Test voltage input/output
Ambient temperature range
-20°C ... +80°C
Operating mode
100% operating factor
Assembly
...480AC/5
4 kVrms
-20°C ... +70°C
100% operating factor
100% operating factor
Directly on the PCB or
can be plugged in with a SIM-AMS socket, which can be soldered
Conformance With EMC Directive 89/336/EEC and Low Voltage Directive 73/23/EEC
Noise Immunity Test According to EN 61000-6-21
Electrostatic discharge (ESD)
EN 61000-4-2
Electromagnetic HF field
EN 61000-4-3
Fast transients (burst)
EN 61000-4-4
Noise Emission Test According to EN 61000-6-4
EN 550112
Noise emission of housing
1
EN 61000 corresponds to IEC 61000
2
EN 55011 corresponds to CISPR11
Approvals
aA
UL
Dimensions
Block Diagrams
43,2
3
2
4
25,4
1
INPUT
4
2
5,9
1 (+)
Figure 2
7,6
17,8
Figure 1
1,1
30,5
35,5
Dimensions (in mm)
7,7
10,5
1
+
2
Figure 3
103082_01_en
Block diagram for OV-24DC/350DC/1 and
OV-24DC/ 60DC/4
3
~
~
Zero voltage switch
OUTPUT
3
~
~
4
Block diagram for OV-24DC/480AC/5
PHOENIX CONTACT
3
OV-24DC …
Load current I/A
Derating Curves
1
0,9
0,8
0,7
0,6
0,5
0,4
0,3
0,2
0,1
0
0
10
Load current I/A
Figure 4
5
4,5
4
3,5
3
2,5
2
1,5
1
0,5
0
Load current I/A
30
40
50
60
70
80
Ambient temperature tA/°C
Derating curve for OV-24DC/350DC/1
Distance 20 mm
Distance 9 mm
0
Figure 5
5
4,5
4
3,5
3
2,5
2
1,5
1
0,5
0
20
10
20
30
40
50
60
70
80
Ambient temperature tA /°C
Derating curve for OV-24DC/ 60DC/4
Distance 20 mm
Distance 9 mm
0
Figure 6
10
20
30
40
50
60
70
Ambient temperature tA/°C
Derating curve for OV-24DC/480AC/5
© PHOENIX CONTACT 11/2006
103082_01_en
PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany
Phone: +49 - 52 35 - 30 0 • Fax: +49 - 52 35 - 34 12 00
www.phoenixcontact.com
4