RAD-SYS-NEMA4X-SMS NEMA 4X enclosure with DC power supply and SMS relay INTERFACE Data sheet 2928_en_B 1 © PHOENIX CONTACT 2011-09-27 Description The prewired control cabinet provides a 24 V DC power supply, surge protection for the line power and terminal blocks for easy connectivity, all mounted on standard NS 35 mounting rail. The 0.75 A power supply provides sufficient power for the radio and several additional components, if necessary, which can be mounted on the 25 cm (10 in.) of available rail mounting space. The selected components provide a robust, consistent signal acquisition system for remote data collection. Simply connect the sensors to the system, plug in the GSM SIM, and enter some simple configuration details to complete the system. 2 – – – – – – Features 1 amp fuse MAINS-PLUGTRAB surge protection for the line input (100 - 240 V AC) Prewired cabinetry with extra terminal blocks for simple, flexible installation NEMA 4X enclosure provides protection against the weather Panel and pole mounting kits available 2 dBi low-profile antenna The PSI-MODEM-SMS-REL/6ADI/4DO/DC is a compact, remote control and signalling station. Six configurable analog/digital inputs and four relay outputs with PDT contacts are monitored and controlled via SMS messages with any GSM mobile phone network. Up to 50 numbers can be entered and programmed to receive SMS messages. Additional information regarding the PSI-MODEM-SMS-REL/6ADI/4DO/DC can be found at www.phoenixcontact.net/catalog. Make sure you always use the latest documentation. It can be downloaded at www.phoenixcontact.net/catalog. This data sheet is valid for all products listed on the following page: RAD-SYS-NEMA4X-SMS 3 Ordering data Products Description Type Order No. Pcs./Pkt. Enclosure, with SMS relay includes power supply and surge protection RAD-SYS-NEMA4X-SMS 2917189 1 Accessories Description Type Order No. Pcs./Pkt. Pole mounting kit RAD-SYS-BKT 2900038 1 GSM/GPRS antenna, omnidirectional, 2 m cable with SMA round connector PSI-GSM/UMTS-QB-ANT 2313371 1 GSM/GPRS antenna, Yagi, 8 dBi with N-type male connector RAD-ANT-GSM/UMTS-QB-YAGI-8 2901561 1 Cable, D-SUB to USB, includes DB-9 to DB-25 adapter CM-KBL-RS232/USB 2881078 1 4 Technical data General data Dimensions (H x W x D) 359 x 311 x 156 mm (14.1 x 12.3 x 6.1 in.) Material Fiberglass Conduit connections 1/2-in. NPT Antenna connection SMA, female STEP-PS/1AC/24DC/0.75 (Order No. 2868635) Input voltage range nominal 100 - 240 V DC Current consumption, typical 0.25 A @ 230 V AC 0.37 A @ 120 V AC Output current, typical 0.75 A (-25…70°C) 0.83 A (-25…40°C) Output current, maximum 1.4 A Nominal output voltage 24 V DC PSI-GSM/UMTS-QB-ANT (Order No. 2313371) Frequency range 850/900/1800/1900/2100 MHz VSWR, typical <2.0 Gain, typical 1.0 dB Operating temperature -40…105°C PT 2-PE/S-230AC-ST (Order No. 2839347) Maximum continuous operating voltage 253 V AC Leakage current @ MCOV (L-N) < 1.1 mA Leakage current to ground < 1.5 µA Maximum discharge surge current (8/20 µs) per mode 10 kA 2928_en_B PHOENIX CONTACT 2 RAD-SYS-NEMA4X-SMS 5 Technical data of PSI-MODEM-SMS-REL/6ADI/4DO/DC General data Housing DIN 43880 housing system Housing dimensions (W x H x D) 88 x 90 x 60 mm Mounting NS35 according to EN 60715 Connection Screw terminal block 2.5 mm², 0.5 Nm, Pozidrive/slotted head Degree of protection IP20 Housing material Noryl SE1, Lexan® EXL9330 Weight 120 g (approximately) Ambient temperature (storage) -40°C … +85°C Ambient temperature (operation) -25°C … +55°C Relative humidity 0 … 90% (no condensation) Transient protection Single pulse 2.5 kV/2.5 Ws Electrical data Nominal operating voltage 12 … 48 V DC Operating voltage 10 … 60 V DC Standby current consumption, approximate 15 mA at 24 V DC Conditions: Dialed into the GSM network, no communication active, inputs not controlled, relay disabled 25 mA at 12 V DC Nominal current consumption 15 mA Inrush current surge 2.6 A, τ = 0.4 ms Analog inputs (IN 1 … 6) Control voltage range 12 … 48 V DC Input voltage range 0 … 60 V DC Operate threshold 9.5 V DC Hysteresis, approximate 5V Current consumption 1.5 mA/24 V Permissible residual current 20 µA Inductive parallel load energy 50 mWs/1 Hz (2.5 kV) Digital inputs (IN 1 … 6) Nominal input range 0 … 10 V DC Effective input range 0 … 12 V DC Maximum input voltage 60 V DC Resolution 10 bits, LSB 12.5 mV approximately Input impedance 142 kΩ Error limit, with reference to input range ±1% Time data Supply startup time (Ri = 0) ≤25 s Minimum control duration for input (AC, DC) ≥200 ms Mains reliability ≥15 ms 2928_en_B PHOENIX CONTACT 3 RAD-SYS-NEMA4X-SMS Relay outputs (OUT 1 … 4) Contact type Single contact, 4PDT Limiting continuous current 10 A (total current 20 A maximum) Inrush current 15 A/20 ms Maximum switching voltage 250 V AC Maximum switching power 250 W Minimum switching voltage 12 V Minimum switching current 10 mA Contact material AgNi 90/10 Mechanical service life 30 x 106 cycles Test voltage Device - contact 2.5 kV (50 Hz, 1 min.) Contact - contact 2.5 kV (50 Hz, 1 min.) Wireless interface Antenna 50 Ω impedance SMA female antenna connector, GSM interface Frequency 850 MHz at 2 W (EGSM) 900 MHz at 2 W (EGSM) 1800 MHz at 1 W (EGSM) 1900 MHz at 1 W (EGSM) Standards Safety EN 60730-1:2000 EMC, immunity to interference EN 6100-6-2:2005 EMC, noise emission EN 6100-6-3:2007 Approvals, conformance, marking c U Conformance with R&TTE directive 1999/5/EC Yes 2928_en_B PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49-(0) 5235-3-00 PHOENIX CONTACT • P.O. Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300 www.phoenixcontact.com 4