marlow industries a global leader in thermoelectric solutions Subsidiary of II-VI Incorporated Thermoelectric Cooler NL4012T RoHS 2002/95/EC Compliant Performance Values Hot Side Temperature (°C) 27°C 50°C Δ Tmax (°C-dry N2): 114 129 Qmax (watts): 0.76 0.86 Imax (amps): 1.0 1.0 Vmax (vdc): 6.7 7.4 AC Resistance (ohms): 6.22 --- Mechanical Characteristics Positive Lead .520 [13.21] Leads: 30 AWG (0.25) Bus Solid Tinned Copper .160 [4.06] Negative Lead .314 [7.98] 2.00 +/-.25 [50.80+/-6.35] .676 [17.17] .005 [0.13] Cold Side A .001 [0.03] .343+/-.013 [8.71 +/-0.33] .001 [0.03] Ceramic Material: Beryllia (BC) Millimeters are in [ ] A Ordering Options Features Model Number Description • • NL4012T-01 both surfaces are metallized NL4012T-02 hot side exterior is metallized NL4012T-03 no metallization Available Modifications • • • 214-340-4900 (tel) ● 214-341-5212 (fax) ● www.marlow.com RoHS 2002/95/EC compliant For example, and NL4012Twith only the hot side metallized is specified as an NL4012T-02BC Pretinned metallized ceramic surface(s) with 117°C solder. Thermistor mounted on edge of cold side ceramic. (Calibration available.) Elevated temperature burn-in with test data provided. Doc # 102-0307 Rev B Page 1 of 2 marlow industries a global leader in thermoelectric solutions Subsidiary of II-VI Incorporated Performance Curves Environment: One atmosphere dry nitrogen Hot Side Temperature: 27°C 80.0 40.0 120.0 80.0 40.0 0.0 0.0 8.0 8.0 6.0 4.0 Q=0 T=0 2.0 0.0 0.0 0.2 0.4 0.6 0.8 1.0 CURRENT (AMPS) 1.2 VOLTAGE (VDC) T (C) 120.0 HEAT LOAD (WATTS) 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 160.0 T (C) HEAT LOAD (WATTS) 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 160.0 VOLTAGE (VDC) Hot Side Temperature: 50°C 6.0 4.0 Q=0 T=0 2.0 0.0 0.0 0.2 0.4 0.6 0.8 1.0 CURRENT (AMPS) 1.2 For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, consult one of our Applications Engineers. Installation Recommended mounting methods: Bonding with thermal epoxy or soldering with metallized ceramics. For additional information, please refer to our TEC Installation Guide. Operation Cautions For maximum reliability, storage and operation below 85°C in a non-condensing environment is recommended. To minimize thermal stress, use linear/proportional temperature control or a similar method rather than an ON/OFF method. Addresses Marlow Industries, Inc. 10451 Vista Park Road Dallas Texas 75238-1645 214-340-4900 (tel) 214-341-5212 (fax) II-VI Japan Inc. WBG Marive East 17F 2-6 Nakase, Mihama-ku Chiba-Shi, Chiba 261-7117 Japan 81 43 297 2693 (tel) 81 43 297 3003 (fax) [email protected] www.ii-vi.co.jp Marlow Industries Europe Aberdeen House, South Road Haywards Heath West Sussex RH164NG UK +44 (0)1444-443404 (tel) +44 (0)1444-443334(fax) II-VI Singapore Pte., Ltd. Blk. 5012, Techplace II #04-07 & 05-07/12, Ang Mo Kio Ave. 5 Singapore 569876 (65) 6481 8215 (tel) (65) 6481 8702 (fax) [email protected] www.ii-vi.com.sg 214-340-4900 (tel) ● 214-341-5212 (fax) ● www.marlow.com Marlow Industries China, II-VI Technologies Beijing A subsidiary of II-VI Incorporated Rm 202, 1# Lize 2nd Middle Road Wangjing, Chaoyang District Beijing 100102 China 64391260 ext 105 (tel) 64399315 (fax) [email protected] Doc # 102-0307 Rev B Page 2 of 2