Présente / Presents: DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com NT90T (T91) NHG RELAYS Safety approvals Safety approval Load UL&CUR T V NO:40A/240VAC 30A/277VAC NC:30A/240VAC 20A/277VAC 2 HP 250VAC TV-5 1 12 HP 250VAC HP:A 1HP/16AFLA/120VAC 2HP/12AFLA/240VAC B 30LRA/10AFLA/120VAC 30LRA/10AFLA/240VAC Insulation B-class F-class NO:40A/240VAC 14VDC NC:30A/240VAC 14VDC Insulation B-class F-class NT90T (T91) CQC NO:30A/240VAC NC:20A/240VAC 32.4 27.5 28.0 Features Small size, light weight. Low coil power consumption, heavy contact load. Strong anti-shock and anti-vibration, high reliability, long life. Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications. PC board mounting and direct insert mounting available. 20max. 0.787max. 0.020 0.130 0.020 (0.146) Ordering Information 3.3 0.130 24.2max. 0.953max. NT90T H L A S DC12V C B 0.9 17max. 0.669max. 1 0.047 0.047 0.209 2.4 0.094 3 4 5 6 7 8 1.279max. 1A SPSTBNO 1B SPSTNC AgCdO AgSnO2 AgSnO2In2O3 0.150 0.1 Wiring diagram(Bottom view) NOTES 1).Dimensions are in millimeters. 2).Inch equivalents are given for general information only. Reference Data Time(m s ec) 4 0.303 Mounting (Bottom view) 0.043 0.606 0.303 0.701 0.043 0.606 0.350 0.303 0.551 0.303 0.701 0.150 0.551 0.606 0.1 1C SPDT(B-M) NO:30A/240VAC,14VDC; NC:20A/240VAC;30A/14VDC NO:40A/250VAC,30VDC; NC:30A/250VAC,30VDC (0.9W) NO:30A/277VAC;NC:20A/277VAC Motor load 2HP 250VAC 1.5HP 250V Lamp load TV-5 Dimensions 6 6 Coil rated voltage(V) AC:12,24,110,120,220 DC:3,5,6,9,12,15,18,24,48,110 7 Contact material C: AgCdO S: AgSnO2 I: AgSnO2 In 2O3 8 Resist heat class B:130 F:155 9 Coil power consumption 0.6:0.6W 0.9:0.9W NIL:2VA Contact Data Contact Arrangement Contact Material Contact Rating (resistive) 0.724 8 9 Open type 0.787 0.882 0.492 2 1 Part number NT90T NT90T2 2 Load H:30A N:40A 3 High NIL: Standard L: Low profile type 4 Contact arrangement A:1A B:1B C:1C 5 Enclosure S: Sealed type D: Dust cover E: Covered O: Open type 0.031 0.059 10 Patent No. 99312549.2 02110881.1 NT90T2 32.4 27.5 20 R2033977.06 mm /inch 0.027 0.027 12 E9930952E01 E160644 E233737 Dimensions 27.6max. 1.087max. 03001003503 Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Operation Electrical Life Mechanical 1100W 7200VA 110VDC 250VAC 30m 105 107 Max. Switching Current:40A Item 3.12 of IEC255-7 Item 3.30 of IEC255-7 Item 3.31 of IEC255-7 Coil Parameter AC Coil Parameter Dash numbers 012AC 024AC 110AC 120AC 220AC Rated voltage VAC Rated Max 12 24 110 120 220 15.6 31.2 143 156 286 Rated current mA 187 95 20 16.5 6.4 Coil resistance 10% 27 120 2360 3040 13490 Pick up voltage VAC(max) (75%of rated voltage) Release voltage VAC(min) (30%of rated voltage) Coil power 9.0 18.0 82.5 90.0 165.0 3.6 7.2 33.0 36.0 66.0 2VA Operate Time ms Release Time ms CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. 119 Ningbo Huaguan Relay Corporation LTD. NT90T (T91) NHG RELAYS Coil Parameter 2-0.8 0.031 1.2X1.2 1.5 0.031 0.059 0.047 0.047 NT90T 6 7.7 0.303 12.3 0.484 10 3-0.8 3-0.8 0.031 0.031 Shock resistance Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass 200m/s2 11ms 10~55Hz double amplitude 1.5mm 10N 235 2 3 0.5s -55~100 -55~125 85% (at 40 ) 31g Low profile type 35g IEC68-2-27 Test Ea IEC68-2-6 Test Fc IEC68-2-21 Test Ua1&Ua2 IEC68-2-20 Test Ta method 1 19.5 0.4 0.016 32.4 Max. 1.275max. NT90T2 Dimensions NC NC IEC68-2-3 Test Ca Qualification inspection: NC NO COM COM NT90T2 NT90T 0.150 Wiring diagram(Top view) 0.551 of IEC255-19-1 and minimum sample size 24. Wiring diagram(Bottom view) NOTES 1).Dimensions are in millimeters. 2).Inch equivalents are given for general information only. 0.606 0.303 0.083 0.701 Item 6 of IEC255-5 Item 6 of IEC255-5 3.3 3.3¡À 00.5 .5 0.130 0.020 50Hz 1500V 50Hz 2500V 0.4 0.016 3.3¡À 00.5 .5 3.3 0.130 0.020 Item 7 of IEC255-5 28Max. 1.102max. Operation condition 0.250 32.4 Max. 1.275max. 10 0.394 15 0.768 27.8 Max. 1.094max. 0.6 Insulation Resistance Dielectric Strength Between contacts Between contact and coil Perform the qualification test as specified in the table 0.020(0.130) 2-? 0.8 2-0.8 1.5 0.031 0.059 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. min (at 500VDC) 0.197 20Max. 8 0.787max. 0.315 5 0 0.5 5¡À .5 (3.3) 0.4 0.5 0.020 2- 0.8 0.031 1.2 1.2 0.047 0.047 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 1000M 27.5 Max. 1.083max. 8 0.252 0.031 0.016 10 0.8 28Max. 1.102 M ax. 15 0.315 0.213 3-6.4 0.9 0.394 10 0.95 0.037 8 0.315 10 0.394 27.5Max. 1.083Max. 0.75 0.029 5.4 3-6.35 0.3 0.5 0.6 0.9 1.2 1.5 1.8 2.4 4.8 11.0 0.75 0.029 17.3 2.25 3.75 4.50 6.75 9.00 10.25 13.50 18.00 36.00 82.50 5.4 0.213 0.681 15 42 60 135 240 375 540 960 3840 20167 0.75 0.037 0.3 0.5 0.6 0.9 1.2 1.5 1.8 2.4 4.8 11.0 27.5 Max. 1.083max. 3.9 6.5 7.8 11.7 15.6 19.5 23.4 31.2 62.4 143 2.25 3.75 4.50 6.75 9.00 10.25 13.50 18.00 36.00 82.50 8 0.315 3-6.35 10 0.250 0.394 3 5 6 9 12 15 18 24 48 110 10 28 40 90 160 250 360 640 2560 13445 Release Time ms 0.020(0.130) 3.9 6.5 7.8 11.7 15.6 19.5 23.4 31.2 62.4 143 Operate Time ms 0.5 (3.3) 3 5 6 9 12 15 18 24 48 110 Coil power W 1.275max. 0.315 5 Max. Release voltage VDC(min) (10% of rated voltage) 32.4 Max. 17.3 0.681 003-600 005-600 006-600 009-600 012-600 015-600 018-600 024-600 048-600 110-600 Rated Coil resistance 10% Pick up voltage VDC(max) (75% of rated voltage) 0.197 003-900 005-900 006-900 009-900 012-900 015-900 018-900 024-900 048-900 110-900 Coil voltage V 32.4Max. 1.275Max. 8 27.5 Max. 1.083max. Dash numbers mm /inch Dimensions DC Coil Parameter 0.043 0.1 Mounting (Bottom view) Ningbo Forward Relay Corporation LTD. 122 NT90T (T91) Coil Parameter 2-0.8 0.031 1.2X1.2 1.5 0.031 0.059 0.047 0.047 NT90T 6 7.7 0.303 12.3 0.484 10 3-0.8 3-0.8 0.031 0.031 Item 6 of IEC255-5 Item 6 of IEC255-5 Shock resistance Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass 200m/s2 11ms 10~55Hz double amplitude 1.5mm 10N 235 2 3 0.5s -55~100 -55~125 85% (at 40 ) 31g Low profile type 35g IEC68-2-27 Test Ea IEC68-2-6 Test Fc IEC68-2-21 Test Ua1&Ua2 IEC68-2-20 Test Ta method 1 19.5 0.016 0.4 3.3 3.3¡À 00.5 .5 0.130 0.020 50Hz 1500V 50Hz 2500V 0.4 0.016 3.3¡À 00.5 .5 3.3 0.130 0.020 Item 7 of IEC255-5 28Max. 1.102max. Operation condition 32.4 Max. 1.275max. NT90T2 Dimensions NC NC IEC68-2-3 Test Ca Qualification inspection: NC NO COM of IEC255-19-1 and minimum sample size 24. 0.250 32.4 Max. 1.275max. 10 0.394 15 0.768 27.8 Max. 1.094max. 0.6 Insulation Resistance Dielectric Strength Between contacts Between contact and coil Perform the qualification test as specified in the table 0.020(0.130) 2-? 0.8 2-0.8 1.5 0.031 0.059 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. min (at 500VDC) 0.197 20Max. 8 0.787max. 0.315 5 0 0.5 5¡À .5 (3.3) 0.4 0.5 0.020 2- 0.8 0.031 1.2 1.2 0.047 0.047 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 1000M 27.5 Max. 1.083max. 8 0.252 0.031 0.016 10 0.8 28Max. 1.102 M ax. 15 0.315 0.213 3-6.4 0.9 0.394 10 0.95 0.037 8 0.315 10 0.394 27.5Max. 1.083Max. 0.75 0.029 5.4 3-6.35 0.3 0.5 0.6 0.9 1.2 1.5 1.8 2.4 4.8 11.0 0.75 0.029 17.3 2.25 3.75 4.50 6.75 9.00 10.25 13.50 18.00 36.00 82.50 5.4 0.213 0.681 15 42 60 135 240 375 540 960 3840 20167 0.75 0.037 0.3 0.5 0.6 0.9 1.2 1.5 1.8 2.4 4.8 11.0 27.5 Max. 1.083max. 3.9 6.5 7.8 11.7 15.6 19.5 23.4 31.2 62.4 143 2.25 3.75 4.50 6.75 9.00 10.25 13.50 18.00 36.00 82.50 8 0.315 3-6.35 10 0.250 0.394 3 5 6 9 12 15 18 24 48 110 10 28 40 90 160 250 360 640 2560 13445 Release Time ms 0.020(0.130) 3.9 6.5 7.8 11.7 15.6 19.5 23.4 31.2 62.4 143 Operate Time ms 0.5 (3.3) 3 5 6 9 12 15 18 24 48 110 Coil power W 1.275max. 0.315 5 Max. Release voltage VDC(min) (10% of rated voltage) 32.4 Max. 17.3 0.681 003-600 005-600 006-600 009-600 012-600 015-600 018-600 024-600 048-600 110-600 Rated Coil resistance 10% Pick up voltage VDC(max) (75% of rated voltage) 0.197 003-900 005-900 006-900 009-900 012-900 015-900 018-900 024-900 048-900 110-900 Coil voltage V 32.4Max. 1.275Max. 8 27.5 Max. 1.083max. Dash numbers mm /inch Dimensions DC Coil Parameter COM NT90T2 NT90T Wiring diagram(Bottom view) NOTES 1).Dimensions are in millimeters. 2).Inch equivalents are given for general information only. 121 0.606 0.303 0.083 0.701 0.551 0.150 Wiring diagram(Top view) 0.043 0.1 Mounting (Bottom view) Ningbo Huaguan Relay Corporation LTD. NT90TP (T92) NHG RELAYS NT90TP (T92) Safety approvals Safety approval UL&CUR T V Load NO:40A/240VAC 30A/277VAC NC: 30A/240VAC 20A/277VAC 2HP 250VAC 1 12 HP 250VAC TV-5 NO: 40A/240VAC 14VDC NC: 30A/240VAC 14VDC Insulation B-class F-class HP:A 1HP/16AFLA/120VAC 2HP/12AFLA/240VAC B 30LRA/10AFLA/120VAC 30LRA/10AFLA/240VAC Insulation B-class F-class CQC NO: 30A/240VAC NC: 20A/240VAC 03001003503 E9930952 R R2033977.07 E160644 Patent No.02110881.1 C 32.4(50) 27 20 32.4(50) 27 28.5 US Features Small size, light weight. Low coil power consumption, heavy contact load. Strong anti-shock and anti-vibration, high reliability, long life. Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications. Reference Data Ordering Information N90TP H L A S 1 2 3 4 1 2 3 4 5 DC12V 5 6 Part number NT90TP T92 NT90TP 2 Load H:30A N:40A High NIL: Standard L: Low profile type Contact arrangement A:1A B:1B C:1C Enclosure S: Sealed type D: Dust cover E: Covered C B 0.9 7 8 9 6 Coil rated Voltage(V) AC:12,24, 110,120,220 DC:3,5,6,9,12,15,18,24,48,110 7 Contact material C: AgCdO S: AgSnO2 ; I: AgSnO2 In 2O 3 8 Resist heat class B:130 F:155 9 Coil power consumption 0.6:0.6W 0.9:0.9W NIL:2VA Contact Data Contact Arrangement Contact Material Contact Rating (resistive) 1A SPSTNO 1B SPSTNC 1C AgCdO AgSnO2 AgSnO2In 2O 3 SPDT(B-M) NO:30A/240VAC,14VDC; NC:20A/240VAC;30A/14VDC NO:40A/250VAC,30VDC; NC:30A/250VAC,30VDC (0.9W) NO:30A/277VAC;NC:20A/277VAC Motor load 2HP 250VAC 1.5HP 250V Lamp load TV-5 Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Operation Electrical life Mechanical 1100W 7200VA 110VDC 250VAC 30m 105 107 Max. Switching Current:40A Item 3.12 of IEC255-7 Item 3.30 of IEC255-7 Item 3.31 of IEC255-7 Coil Parameter AC Coil Parameter Dash numbers 012AC 024AC 110AC 120AC 220AC Rated voltage VAC Rated Max 12 24 110 120 220 15.6 31.2 143 156 286 Rated current mA 187 95 20 16.5 6.4 Coil resistance 10% 27 120 2360 3040 13490 Pick up voltage VAC(max) (75%of rated voltage) Release voltage VAC(min) (30%of rated voltage) Coil power 9.0 18.0 82.5 90.0 165.0 3.6 7.2 33.0 36.0 66.0 2VA Operate Time ms Release Time ms CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. Ningbo Forward Relay Corporation LTD. 124