Présente / Presents: DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com NT90TP (T92) NT90TP (T92) 03001003503 E9930952 R 32.4(50) 27 20 32.4(50) 27 R2033977.07 C US E160644 Patent No.02110881.1 28.5 Features Small size, light weight. Low coil power consumption, heavy contact load. Strong anti-shock and anti-vibration, high reliability, long life. Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications. Ordering Information N90TP 1 1 2 3 4 5 H 2 L 3 A S 4 5 DC12V C 6 Part number NT90TP T92 NT90TP 2 Load H:30A N:40A High NIL: Standard L: Low profile type Contact arrangement A:1A B:1B C:1C Enclosure S: Sealed type D: Dust cover E: Covered 7 B 8 0.9 9 6 Coil rated Voltage(V) AC:12,24, 110,120,220 DC:3,5,6,9,12,15,18,24,48,110 7 Contact material C: AgCdO S: AgSnO2 ; I: AgSnO2 In 2O 3 8 Resist heat class B:130 F:155 9 Coil power consumption 0.6:0.6W 0.9:0.9W NIL:2VA Contact Data Contact Arrangement Contact Material Contact Rating (resistive) 1A SPSTNO 1B SPSTNC 1C AgCdO AgSnO2 AgSnO2In 2O 3 SPDT(B-M) NO:30A/240VAC,14VDC; NC:20A/240VAC;30A/14VDC NO:40A/250VAC,30VDC; NC:30A/250VAC,30VDC (0.9W) NO:30A/277VAC;NC:20A/277VAC Motor load 2HP 250VAC 1.5HP 250V Lamp load TV-5 Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Operation Electrical life Mechanical 1100W 7200VA 110VDC 250VAC 30m 105 107 Max. Switching Current:40A Item 3.12 of IEC255-7 Item 3.30 of IEC255-7 Item 3.31 of IEC255-7 Coil Parameter AC Coil Parameter Dash numbers 012AC 024AC 110AC 120AC 220AC Rated voltage VAC Rated Max 12 24 110 120 220 15.6 31.2 143 156 286 Rated current mA 187 95 20 16.5 6.4 Coil resistance 10% 27 120 2360 3040 13490 Pick up voltage VAC(max) (75%of rated voltage) Release voltage VAC(min) (30%of rated voltage) Coil power 9.0 18.0 82.5 90.0 165.0 3.6 7.2 33.0 36.0 66.0 2VA Operate Time ms Release Time ms CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. Ningbo Huaguan Relay Corporation LTD. NHG RELAYS Coil Parameter DC Coil Parameter Dash numbers Rated voltage VDC Coil resistance 10% Pick up voltage VDC(max) (75%of rated voltage) Release voltage VDC(min) (10%of rated voltage) Rated Max 003-900 005-900 006-900 009-900 012-900 015-900 018-900 024-900 036-900 048-900 110-900 3 5 6 9 12 15 18 24 36 48 110 3.9 6.5 7.8 11.7 15.6 19.5 23.4 31.2 46.8 62.4 143 10 28 40 90 160 250 360 640 1440 2560 13445 2.25 3.75 4.50 6.75 9.00 10.25 13.50 18.00 27.00 36.00 82.50 0.3 0.5 0.6 0.9 1.2 1.5 1.8 2.4 3.6 4.8 11.0 003-600 005-600 006-600 009-600 012-600 015-600 018-600 024-600 048-600 110-600 3 5 6 9 12 15 18 24 48 110 3.9 6.5 7.8 11.7 15.6 19.5 23.4 31.2 62.4 143 15 42 60 135 240 375 540 960 3840 20167 2.25 3.75 4.50 6.75 9.00 10.25 13.50 18.00 36.00 82.50 0.3 0.5 0.6 0.9 1.2 1.5 1.8 2.4 4.8 11.0 Coil power W Operate Time ms Release Time ms 0.9 15 10 0.6 15 10 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. Operation condition Insulation Resistance Dielectric Strength 1000M Between contacts Between contact and coil 50Hz 1500V 50Hz 2500V Shock resistance Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass min (at 500VDC) 2 Item 7 of IEC255-5 Item 6 of IEC255-5 Item 6 of IEC255-5 200m/s 11ms 10~55Hz double amplitude 1.5mm 10N 235 2 3 0.5s -55~100 -55~125 85% (at 40 ) 35g Low profile type 37g IEC68-2-27 Test Ea IEC68-2-6 Test Fc IEC68-2-21 Test Ua2 IEC68-2-20 Test Ta method 1 IEC68-2-3 Test Ca Qualification inspection: Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24. Safety approvals Safety approval UL&CUR T V Load NO:40A/240VAC 30A/277VAC NC:30A/240VAC 20A/277VAC 2HP 250VAC TV-5 1 12 HP 250VAC HP:A 1HP/16AFLA/120VAC 2HP/12AFLA/240VAC B 30LRA/10AFLA/120VAC 30LRA/10AFLA/240VAC Insulation B-class F-class NO:40A/240VAC 14VDC NC:30A/240VAC 14VDC Insulation B-class F-class CQC NO:30A/240VAC NC:20A/240VAC NT90TP (T92) Dimensions mm /inch 43.5 1.713 43.5 2-0.5x2.8 0.020 1.713 0.110 2-0.5x2.8 15.4 0.020 0.110 0.606 2-R1.8 15.4 0.401 7.8 0.307 0.252 0.110 6.4 2.8 2.8 0.704 0.110 0.142 0.008 3.6 3.8 0.2 7.7 17.9 27.5Max. 1.063max. 0.787max. 0.307 2.2 1.102max. 50.2Max. 1.976max. 50.2 1.976max. 20Max. 7.8 32.5Max. 1.280max. 0.087 2 NC 0.303 27.5 Max. 1.063max. 0.079 28 Max. 32.5Max. 1.280max. NO COM 0.150 10.2 0.401 7.8 2.8 0.110 6.4 2.8 0.303 17.9 0.704 0.110 3.8 0.2 7.7 0.307 NC 0.252 NO COM 0.150 0.008 3.6 0.606 2-R1.8 R0.071 0.142 10.2 R0.071 NT90TP 0.189 0.031 0.252 2.8 0.110 0.007 7.7 0.2 0.303 0.007 2.2 COM 1.110max. 27.5 Max. 1.083max. 28.2 Max. 32.5Max. 1.280max. N0 COM 3-6.4X0.8 15.4 0.2 0.606 0.087 COM 0.007 3.6 N0 NC 0.484 0.007 R0.071 15.4 0.2 NC 12.3 0.2 0.020 0.315 2-R1.8 COM NT90TP 2 2-0.5X4.8 0.142 N0 0.401 10.2 0.2 NC 0.007 43.5 1.713 50.2Max. 1.976max. NT90TP Wiring diagram NOTES 1). Dimensions are in millimeters. 2). Inch equivalents are given for general information only. NT90TP2 Dimensions Reference Data Time (m sec) 12 10 8 6 4 Ningbo Huaguan Relay Corporation LTD.