MURATA NTE1212MC

NTE Series
www.murata-ps.com
Isolated 1W Single Output SM DC/DC Converters
SELECTION GUIDE
1
Order Code
FEATURES
„
RoHS compliant
„
Lead frame technology
„
Single isolated output
„
1kVDC Isolation
„
Efficiency up to 78%
„
Power density 1.8W/cm3
„
Wide temperature performance at full
1 Watt load, –40°C to 85°C
Nominal
Input
Voltage
V
NTE0303MC
NTE0305MC
NTE0309MC
NTE0312MC
NTE0315MC
NTE0503MC
NTE0505MC
NTE0505MEC
NTE0506MC
NTE0509MC
NTE0512MC
NTE0515MC
NTE1205MC
NTE1209MC
NTE1212MC
NTE1215MC
V
mA
Input
Current at
Rated Load
mA
3.3
5
9
12
15
3.3
5
5
6
9
12
15
5
9
12
15
303
200
111
83
66
303
200
200
167
111
83
66
200
111
83
66
410
390
400
400
400
270
294
260
278
267
260
256
124
114
113
111
Output
Voltage
3.3
3.3
3.3
3.3
3.3
5
5
5
5
5
5
5
12
12
12
12
Output
Current
Efficiency
Isolation
Capacitance
%
pF
kHrs
73
78
77
77
77
74
68
77
72
75
77
78
67
73
74
75
30
35
31
28
29
40
35
40
39
43
42
44
47
77
88
95
5348
3847
3134
3473
2473
5515
6857
3933
6677
5501
3957
2747
4683
4008
3121
2316
MTTF2
„
UL 94V-0 Package material
„
Footprint over pins 1.37cm2
INPUT CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Max.
„
3.3V, 5V, 9V, 12V & 15V output
Voltage range
„
No heatsink required
Continuous operation, 3.3V input types
Continuous operation, 5V input types
Continuous operation, 12V input types
2.97
4.5
10.8
Reflected ripple current
3.3
5.0
12.0
30
3.63
5.5
13.2
47
mA p-p
Typ.
Max.
Units
„
3.3V, 5V & 12V Input
Units
V
„
Internal SMD construction
„
Toroidal magnetics
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
„
MTTF up to 6.8 million hours
Isolation voltage
Resistance
Flash tested for 1 second
Viso= 1000VDC
1000
10
„
Custom solutions available
„
Multi-layer ceramic capacitors
PRODUCT OVERVIEW
The NTE series of miniature surface mounted
DC/DC Converters employ leadframe technology and transfer moulding techniques to bring
all of the benefits of IC style packaging to hybrid
circuitry. The co-planarity of the pin positions is
based upon IEC 191-6:1990. The devices are
suitable for all applications where high volume
production is envisaged.
VDC
GΩ
GENERAL CHARACTERISTICS
Parameter
Conditions
Switching frequency
All output types
Min.
Typ.
110
Max.
Units
kHz
ABSOLUTE MAXIMUM RATINGS
Lead temperature 1.5mm from case for 10 seconds
Internal power dissipation
Input voltage VIN, NTE03 types
Input voltage VIN, NTE05 types
Input voltage VIN, NTE12 types
300°C
600mW
5.5V
7V
15V
1. If components are required in tape and reel format suffix order code with -R, e.g. NTE0505MC-R.
2. Calculated using MIL-HDBK-217 FN2 calculation model with nominal input voltage at full load.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_NTE.K03 Page 1 of 6
NTE Series
Isolated 1W Single Output SM DC/DC Converters
OUTPUT CHARACTERISTICS
Parameter
Conditions
Rated power
Voltage set point accuracy
Line regulation
TA=-40°C to 85°C
See tolerance envelope
High VIN to low VIN
10% load to rated load, 03XXMC, 0503MC, 0505MEC
10% load to rated load, 0505MC & 1205MC
10% load to rated load, 0506MC
10% load to rated load, 0509MC & 1209MC
10% load to rated load, 0512MC & 1212MC
10% load to rated load, 0515MC & 1215MC
BW=DC to 20MHz, 03XXMC, 0503MC, 0505MEC
BW=DC to 20MHz, 0505MC & 1205MC
BW=DC to 20MHz, 0506MC
BW=DC to 20MHz, 0509MC & 1209MC
BW=DC to 20MHz, 0512MC & 1212MC
BW=DC to 20MHz, 0515MC & 1215MC
Load regulation1
Ripple and noise
Min.
Typ.
Max.
Units
1.0
W
1.0
10
12.8
9.2
8.3
6.8
6.3
40
62
103
49
39
38
1.2
14
15
10
9.0
7.5
7.0
60
85
170
75
65
76
%/%
Typ.
Max.
%
mV p-p
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Specification
Storage
All output types
-40
-55
Case temperature rise above
ambient
Cooling
0305MC, 0309MC, 0315MC
0303MC, 0312MC, 0503MC, 0505MEC, 0509MC, 0512MC, 0515MC
0505MC, 1205MC
1209MC, 1212MC, 1215MC
Free air convection
Units
85
125
25
30
43
40
°C
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NTE series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
For a part holding no specific agency approvals, such as the NTE series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or
60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to
safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The NTE series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
TEMPERATURE DERATING GRAPH
Output Power (W)
1.5
1.0
0.5
0
-40
85°C
Safe Operating Area
100
50
0
Ambient Temperature (°C)
150
1. 12V input types have typically 3% less load regulation change.
www.murata-ps.com/support
KDC_NTE.K03 Page 2 of 6
NTE Series
Isolated 1W Single Output SM DC/DC Converters
TOLERANCE ENVELOPES
3.3V output types.
All other types.
+10%
+9%
oad Lin
Output Voltage
+1%
VNOM
e
+1%
-7%
-7%
-15%
10
75
50
25
Output Load Current (%)
+5%
VNOM
100
Output Voltage
Typical
L
Typical
L
oad Line
+2.5%
-2.5%
-7.5%
10
75
50
25
Output Load Current (%)
100
The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to
changes in output loading.
RoHS COMPLIANCE, MSL AND PSL INFORMATION
This series is compatible with RoHS soldering systems and is also backward compatible with Sn/Pb soldering systems.
The NTE series has a process, moisture, and reflow sensitivity classification of MSL1 PSL R7F as defined in J-STD-020
and J-STD-075. This translates to: MSL1 = unlimited floor life, PSL R7F = Peak reflow temperature 245°C with a
limitation on the time above liquidus (217°C) which for this series is 60sec max. The pin termination finish on this product
series is Gold with a plating thickness of 0.05 microns minimum.
For further information please visit www.murata-ps.com/rohs
APPLICATION NOTES
Minimum load
The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in
an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%.
Capacitive loading and start up
Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product
series will start into a capacitance of 47μF with an increased start time, however, the maximum recommended output capacitance is 10μF.
NTE0303MC
NTE0305MC
NTE0309MC
NTE0312MC
NTE0315MC
NTE0503MC
NTE0505MC
NTE0505MEC
Start-up time
μs
437
1359
3435
6590
7625
533
1368
721
NTE0506MC
NTE0509MC
NTE0512MC
NTE0515MC
NTE1205MC
NTE1209MC
NTE1212MC
NTE1215MC
Start-up time
μs
7200
3146
4960
7740
895
2150
3640
7180
Typical Start-Up Wave Form
www.murata-ps.com/support
KDC_NTE.K03 Page 3 of 6
NTE Series
Isolated 1W Single Output SM DC/DC Converters
APPLICATION NOTES (continued)
Output Ripple Reduction
By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max.
Component selection
Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended.
The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC/DC converter.
Inductor: The rated current of the inductor should not be less than that of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor
should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF (Self Resonant Frequency) should be
>20MHz.
L
DC
Power
Source
NTE0303MC
NTE0305MC
NTE0309MC
NTE0312MC
NTE0315MC
NTE0503MC
NTE0505MC
NTE0505MEC
NTE0506MC
NTE0509MC
NTE0512MC
NTE0515MC
NTE1205MC
NTE1209MC
NTE1212MC
NTE1215MC
L, μH
10
47
22
10
47
10
47
47
10
22
47
47
47
22
47
47
Inductor
SMD
82103C
82473C
82223C
82103C
82473C
82103C
82473C
82473C
82103C
82223C
82473C
82473C
82473C
82223C
82473C
82473C
C
Load
DC
Through Hole
11R103C
11R103C
11R223C
11R103C
11R473C
11R103C
11R473C
11R473C
11R103C
11R223C
11R473C
11R473C
11R473C
11R223C
11R473C
11R473C
Capacitor
C, μF
4.7
4.7
2.2
1
1
4.7
4.7
4.7
4.7
2.2
1
1
4.7
2.2
1
1
www.murata-ps.com/support
KDC_NTE.K03 Page 4 of 6
NTE Series
Isolated 1W Single Output SM DC/DC Converters
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
PIN CONNECTIONS
12.70 (0.500)
7.62 (0.300)
14
11.20 (0.441) 7.70 (0.303)
10.40 (0.409)
10
12
DETAIL A
8
NTE0505MC
P
XYYWW
1
3
5
1.50 (0.059)
1.20 (0.047)
7
0.65 (0.026)
0.55 (0.022)
2.54 (0.100)
10 PINS
0.2 (0.008)
±5.00°
Function
1
3
5
7
8
10
-VIN
+VIN
NA
-VOUT
+VOUT
NA
NA
NA
12
14
S
2.10 (0.083)
DETAIL A
NA - Not available for electrical connection.
6.60 (0.260) 6.35 (0.250)
5.95 (0.234) 5.85 (0.230)
2.79 (0.110) MAX
0.50 (0.020)
REFERENCE
PLANE
Pin
S
0.25 (0.010)
0.10 (0.004)
1.875 MAX
0.1(0.004) S
All dimensions in mm ±0.25mm (inches ±0.01). All pins on a 2.54 (0.1) pitch and within ± 0.25 (0.01) of true position.
0.30 (0.012)
0.20 (0.008)
Weight: 1.21g
TUBE OUTLINE DIMENSIONS
RECOMMENDED FOOTPRINT DETAILS
7.62
(0.3)
SEATING
PLANE
0.60±0.15 (0.024±0.006)
2.10 (0.083)
2.00 (0.079)
9.70
(0.382)
9.40 (0.370)
14.35 (0.565)
2.54 (0.1)
1.00 (0.040) MIN
All pins on a 2.54mm pitch.
Unless otherwise stated all dimensions in mm (inches) ±0.5mm.
6.70 (0.264)
Unless otherwise stated all dimensions in mm±0.5mm (inches ±0.02).
Tube length : 475±2.0 (18.70±0.07).
Tube Quantity : 35
www.murata-ps.com/support
KDC_NTE.K03 Page 5 of 6
NTE Series
Isolated 1W Single Output SM DC/DC Converters
TAPE & REEL SPECIFICATIONS
REEL OUTLINE DIMENSIONS
TAPE OUTLINE DIMENSIONS
330
(12.99) MAX
13.20
(0.52)
0.60 (0.02) MAX
100
Ø (3.94) MIN
+0.004 (+0.10)
-0.00 (-0.00)
DIRECTION OF UNREELING
13.00±0.25
Ø (0.51±0.009)
2.00
(0.08)
30.40 (1.20) MAX
2.00(+0.08)
(AT HUB SECTION)
24.40 (0.96)
-0.00 (0.00)
1.50 (Ø0.06)
16.00 (0.63)
11.60
(0.46)
4.00
(0.16)
1.75(0.07)
11.50
(0.45)
24.00±0.30
(0.94±0.04)
6.60
(0.26)
REEL PACKAGING DETAILS
XYYWW
Product Orientation
Pin 1, located nearest to
carrier drive sprocket.
NTE0505MC
XYYWW
NTE0505MC
XYYWW
NTE0505MC
TRAILER SECTION
160 (6.30) MIN
GOODS ENCLOSURE
SECTION
CARRIER TAPE START
100 (3.94) MIN
LEADER SECTION
400 (15.75) MIN
Reel Quantity : 500
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2012 Murata Power Solutions, Inc.
www.murata-ps.com/support
KDC_NTE.K03 Page 6 of 6