IRF OM1905N2M

OM1905N2M
OM1912N2M
OM1915N2M
HERMETIC SURFACE MOUNT FIXED VOLTAGE NEGATIVE
REGULATORS APPROVED TO DESC DRAWING
LCC 20, Fixed Voltage, Precision
Negative Regulators In Hermetic
Surface Mount Package
FEATURES
•
•
•
•
•
•
Hermetic Surface Mount Package
Output Voltages: -5V, -12V, -15V
Output Voltages Set Internally To ±1%
Built-In Thermal Overload Protection
Short Circuit Current Limiting
Product Is Available Hi-Rel Screened
DESCRIPTION
These negative regulators are supplied in a hermetically sealed surface mount
package. All protective features are designed into the circuit including thermal
shutdown, current limiting and safe-area control. With heat sinking, they can deliver
over .5 amps of output current. These units feature internally trimmed output
voltages to ±1% of nominal voltage. Standard voltages are -5V, -12V, and -15V.
These units are ideally suited for Military applications where a hermetic surface
mount package is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number
5962-8874601 2X
5962-8874701 2X
5962-8874801 2X
4 11 R0
3.5 - 49
Omnirel Part Number
OM1905N2M
OM1912N2M
OM1915N2M
3.5
OM1905N2M - OM1915N2M
ABSOLUTE MAXIMUM RATINGS @ 25°C
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . .- 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Typical Power/Thermal Charateristics:
Rated Power @ 25° C TC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2W
TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1040 mW
Thermal Resistance
θJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25°C/W
θJA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120°C/W
ELECTRICAL CHARACTERISTICS -5 Volt
VIN = -10V, Io = 100mA, -55°C ≤ TA ≤ 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VOUT
TA = 25°C
-4.95
-5.05
V
-4.85
-5.15
V
12
mV
25
mV
VIN = -7.5V to -20V
•
IO = 5 mA to 500 mA, P < 2W
Line Regulation
VRLINE
VIN = -7.5V to -20V
•
(Note 1)
VIN = -8.0V to -12V
(Note 4)
5
mV
12
mV
25
mV
50
mV
2.5
mA
3.0
mA
VIN = -7.0V to -20V
•
•
0.4
mA
IO = 5mA to 500 mA
•
0.4
mA
•
•
Load Regulation
VRLOAD
IO = 5mA to 500 mA
•
(Note 1)
Standby Current Drain
ISCD
Standby Current Drain
∆ISCD
Change With Line
(Line)
Standby Current Drain
∆ISCD
Change With Load
(Load)
Dropout Voltage
VDO
∆VOUT = 100mV, IO = 500 mA
Peak Output Current
IO (pk)
TA = 25°C
Short Circuit Current
IDS
VIN = -35V
0.5
•
(Note 2)
2.5
V
1.7
A
.7
A
2.0
A
∆VIN
f =120 Hz, ∆VIN = -10V
∆VOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
40
Long Term Stability
∆VOUT
TA = 25°C, t = 1000 hrs.
75
(Note 3)
∆t
Ripple Rejection
Output Noise Voltage
63
•
dB
60
dB
(Note 3)
3.5
µV/V
RMS
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
3.5 - 50
OM1905N2M - OM1915N2M
ELECTRICAL CHARACTERISTICS -12 Volt
VIN = -19V, Io = 100 mA, -55°C ≤ TA ≤ 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VOUT
TA = 25°C
-11.88
-12.12
V
-11.64
-12.36
V
20
mV
•
VIN = -14.5V to -27V
IO = 5mA to 500 mA, PD < 2 W
Line Regulation
VRLINE
VIN = -14.5V to -27V
•
(Note 1)
VIN = -16V to -22V
(Note 4)
•
Load Regulation
VRLOAD
IO = 5 mA to 500 mA
•
∆ISCD
Change With Line
(Line)
Standby Current Drain
∆ISCD
Change With Load
(Load)
30
mV
32
mV
mV
mA
4.0
mA
VIN = -14.5V to -27V
•
•
0.8
mA
IO = 5mA to 500 mA
•
0.5
mA
•
1.8
V
Dropout Voltage
VDO
∆VOUT = 100mV, IO = 500 mA
Peak Output Current
IO (pk)
TA = 25°C, IO = 5 mA to 1A
Short Circuit Current
IDS
VIN = -35V
∆VIN
f =120 Hz, ∆VIN = -10V
0.5
•
(Note 2)
Ripple Rejection
mV
60
ISCD
Standby Current Drain
mV
10
3.5
(Note 1)
Standby Current Drain
50
1.7
A
.7
A
2.0
dB
∆VOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100 KHz
40
Long Term Stability
∆VOUT
TA = 25°C, t = 1000 hrs.
120
(Note 3)
∆t
Output Noise Voltage
A
56
•
53
dB
µV/V
(Note 3)
RMS
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
MECHANICAL OUTLINE
PIN CONNECTION
Terminal Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
NC
VINput
NC
VOUTput
VOUTput
NC
VOUTput
NC
NC
NC
NC
NC
NC
NC
Ground
NC
Ground
NC
NC
VINput
Note: The input pins (2 and 20) are to be connected
together, the output pins (4,5, and 7) are to be
connected together and the ground pins (15 and 17)
are to be connected together for operation.
.009 R.
20 PLCS.
.065
.020 X45°
REF.
(±.003)
.040
.010
3
.025
TYP.
.075 (±.010)
TYP.
4
9
.160
SQ. REF.
1
.085
13
19
.003
.025 SQ.
TYP.
18
.050 (±.005)
TYP.
3.5 - 51
14
.050
TYP.
.040 X45°
REF (3 PL)
3.5
OM1905N2M - OM1915N2M
ELECTRICAL CHARACTERISTICS -15 Volt
VIN = -23V, Io = 100mA, -55°C ≤ TA ≤ 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VOUT
TA = 25°C
-14.85
-15.15
V
-14.55
-15.45
V
25
mV
VIN = -17.5V to -30V
•
IO = 5 mA to 500 m A, PD < 2 W
Line Regulation
VRLINE
VIN = -17.5V to -30V
•
(Note 1)
VIN = -20V to -26V
(Note 4)
•
Load Regulation
VRLOAD
IO = 5mA to 500 mA
•
∆ISCD
Change With Line
(Line)
Standby Current Drain
∆ISCD
Change With Load
(Load)
mV
25
mV
50
mV
90
mV
mA
6.5
mA
VIN = -17.5V to -30V
•
•
0.8
mA
IO = 5mA to 500 mA
•
0.5
mA
•
ISCD
Standby Current Drain
mV
15
6.0
(Note 1)
Standby Current Drain
50
Dropout Voltage
VDO
∆VOUT = 100mV, IO = 500 mA
Peak Output Current
IO (pk)
TA = 25°C
Short Circuit Current
IDS
VIN = -35V
0.5
•
(Note 2)
2.5
V
1.7
A
0.7
A
2.0
A
∆VIN
f =120 Hz, ∆VIN = -10V
∆VOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
40
Long Term Stability
∆VOUT
TA = 25°C, t = 1000 hrs.
150
(Note 3)
∆t
Ripple Rejection
Output Noise Voltage
53
•
dB
50
dB
(Note 3)
µV/V
RMS
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
3.5