ETC OM1915NMM

OM1905NMM OM1915NMM
OM1912NMM
HERMETIC SURFACE MOUNT FIXED VOLTAGE NEGATIVE
REGULATORS APPROVED TO DESC DRAWINGS
Three Terminal, Fixed Voltage, 1.5 Amp
Precision Negative Regulators In Hermetic
Surface Mount Package
FEATURES
•
•
•
•
•
•
Hermetic Surface Mount Package
Output Voltages: -5V, -12V, -15V
Output Voltages Set Internally To ±1%
Built-In Thermal Overload Protection
Short Circuit Current Limiting
Product Is Available Hi-Rel Screened
DESCRIPTION
These three terminal negative regulators are supplied in a hermetically sealed
surface mount package. All protective features are designed into the circuit including
thermal shutdown, current limiting and safe-area control. With heat sinking, they can
deliver over 1.5 amps of output current. These units feature internally trimmed output
voltages to ±1% of nominal voltage. Standard voltages are -5V, -12V, and
-15V. These units are ideally suited for Military applications where a hermetic surface
mount package is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number
5962-8874601 NX
5962-8874701 NX
5962-8874801 NX
Omnirel Part Number
OM1905NMM
OM1912NMM
OM1915NMM
3.5
4 11 R0
3.5 - 53
OM1905NMM - OM1915NMM
ABSOLUTE MAXIMUM RATINGS @ 25°C
Input Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . .- 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Typical Power/Thermal Charateristics:
Rated Power @ 25° C TC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15W
TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3W
Thermal Resistance
θJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5°C/W aa
θJA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120°C/W
ELECTRICAL CHARACTERISTICS -5 Volt
VIN = -10V, Io = 500mA, -55°C ≤ TA ≤ 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VOUT
TA = 25°C
-4.95
-5.05
V
-4.85
-5.15
V
12
mV
25
mV
VIN = -7.5V to -20V
•
IO = 5mA to 1.0 A, P < 15W
Line Regulation
VRLINE
VIN = -7.5V to -20V
•
(Note 1)
VIN = -8.0V to -12V
(Note 4)
Load Regulation
VRLOAD
5
mV
•
12
mV
20
mV
•
25
mV
15
mV
30
mV
2.5
mA
3.0
mA
VIN = -7.0V to -20V
•
•
0.4
mA
IO = 5mA to 1000mA
•
0.4
mA
•
IO = 5mA to 1.5 Amp
(Note 1)
IO = 250mA to 750 mA
•
Standby Current Drain
ISCD
Standby Current Drain
∆ISCD
Change With Line
(Line)
Standby Current Drain
∆ISCD
Change With Load
(Load)
Dropout Voltage
VDO
∆VOUT = 100mV, IO = 1.0A
Peak Output Current
IO (pk)
TA = 25°C
Short Circuit Current
IDS
VIN = -35V
1.5
•
(Note 2)
2.5
V
3.3
A
1.2
A
2.8
A
∆VIN
f =120 Hz, ∆VIN = -10V
∆VOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
40
Long Term Stability
∆VOUT
TA = 25°C, t = 1000 hrs.
75
(Note 3)
∆t
Ripple Rejection
Output Noise Voltage
63
•
dB
60
dB
(Note 3)
3.5
µV/V
RMS
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
3.5 - 54
OM1905NMM - OM1915NMM
ELECTRICAL CHARACTERISTICS -12 Volt
VIN = -19V, Io = 500mA, -55°C ≤ TA ≤ 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VOUT
TA = 25°C
-11.88
-12.12
V
-11.64
-12.36
V
VIN = -14.5V to -27V
•
IO = 5mA to 1.0 A, P < 15W
Line Regulation
VIN = -14.5V to -27V
VRLINE
(Note 1)
20
mV
•
50
mV
10
mV
•
30
mV
32
mV
VIN = -16V to -22V
(Note 4)
Load Regulation
IO = 5mA to 1.5 Amp
VRLOAD
•
(Note 1)
IO = 250mA to 750 mA
•
Standby Current Drain
∆ISCD
Change With Line
(Line)
Standby Current Drain
∆ISCD
Change With Load
(Load)
mV
30
mV
mA
4.0
mA
VIN = -14.5V to -27V
•
•
0.8
mA
IO = 5mA to 1000mA
•
0.5
mA
•
1.8
V
Dropout Voltage
VDO
∆VOUT = 100mV, IO = 1.0A
Peak Output Current
IO (pk)
TA = 25°C, IO = 5mA to 1A
Short Circuit Current
IDS
VIN = -35V
∆VIN
f =120 Hz, ∆VIN = -10V
1.5
•
(Note 2)
Ripple Rejection
mV
16
3.5
ISCD
Standby Current Drain
60
3.3
A
1.2
A
2.8
56
∆VOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
40
Long Term Stability
∆VOUT
TA = 25°C, t = 1000 hrs.
120
(Note 3)
∆t
Output Noise Voltage
•
A
dB
53
dB
(Note 3)
µV/V
RMS
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5 mA.
CONNECTION DIAGRAM
MECHANICAL OUTLINE
.140
.140
.140
.015
.075
.157
.075
1
2
.415
3
.062
.375
.030
MIN.
3.5 - 55
Pin 1 Ground
Pin 2 Output
Pin 3 Input
3.5
OM1905NMM - OM1915NMM
ELECTRICAL CHARACTERISTICS -15 Volt
VIN = -23V, Io = 500mA, -55°C ≤ TA ≤ 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VOUT
TA = 25°C
-14.85
-15.15
V
-14.55
-15.45
V
•
VIN = -17.5V to -30V
IO = 5mA to 1.0 A, P < 15W
Line Regulation
VIN = -17.5V to -30V
VRLINE
•
(Note 1)
VIN = -20V to -26V
(Note 4)
•
Load Regulation
IO = 5mA to 1.5 Amp
VRLOAD
•
(Note 1)
IO = 250mA to 750 mA
•
Standby Current Drain
∆ISCD
Change With Line
(Line)
Standby Current Drain
∆ISCD
Change With Load
(Load)
mV
mV
15
mV
25
mV
35
mV
75
mV
21
mV
45
mV
6.0
mA
6.5
mA
VIN = -17.5V to -30V
•
•
0.8
mA
IO = 5mA to 1000 mA
•
0.5
mA
•
ISCD
Standby Current Drain
25
50
Dropout Voltage
VDO
∆VOUT = 100mV, IO = 1.0A
Peak Output Current
IO (pk)
TA = 25°C
Short Circuit Current
IDS
VIN = -35V
1.5
•
(Note 2)
2.5
V
3.3
A
1.2
A
2.8
A
∆VIN
f =120 Hz, ∆VIN = -10V
∆VOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
40
Long Term Stability
∆VOUT
TA = 25°C, t = 1000 hrs.
150
(Note 3)
∆t
Ripple Rejection
Output Noise Voltage
53
•
dB
50
dB
µV/V
(Note 3)
RMS
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
TYPICAL PERFORMANCE CHARACTERISTICS
PEAK OUTPUT
RIPPLE REJECTION
DROPOUT VOLTAGE
3.5
2.5
100
2
2
Tj = 25°C
1.5
1
Tj = 150°C
0.5
5
10
15
1.5
IOUT = 500mA
1
IOUT = 0A
0.5
20
25
30
35
0
-75-50 -25 0
VOUT = 5V
60
40
VIN - V = 8VDC +3.5Vrms
IOUT = 1A
Tj = 25°C
20
∆VOUT = 100MV
∆VOUT = 100mV
0
80
IOUT = 1A
Ripple Rejection (dB)
Tj = -55°C
2.5
Output Current (A)
3.5
Output Current (A)
3
2 5 5 0 7 5 100 125150
0
10
Input To Output Differential (V)
Junction Temperature (°C)
100
1k
10k
Frequency (Hz)