P25A-T 25W AC-DC Triple Output Desktop series Features : 3 pole AC inlet IEC320-C14 Class power (with earth pin) Protections: Short circuit / Overload / Over voltage / Over temp. Fully enclosed plastic case Fix switching frequency and regulation Topology: Top switch circuit LED indicator for power on Approvals: UL / CUL / TUV / CB / CE 1 year warranty TUV Rheinland Product Safety SPECIFICATION ORDER NO. SAFETY MODEL NO. P25A13D-R1B P25A14E-R1B PSU25A-13D PSU25A-14E 12V -5V 5V 12V -12V 5V 15V -15V RATED CURRENT 2.5A 0.8A 0.3A 2.5A 0.8A 0.3A 2.5A 0.5A 0.3A CURRENT RANGE 0.5 ~ 2.5A 0.1 ~ 0.8A 0.1 ~ 0.3A 0.5 ~ 2.5A 0.1~0.8A 0.1 ~0.3A 0.5 ~ 2.5A 0.1 ~ 0.5A 0.1 ~ 0.3A RATED POWER 25W 100mVp-p 100mVp-p DC VOLTAGE OUTPUT P25A13A-R1B PSU25A-13A Note.2 5V geprUfre Sicherheit 25W RIPPLE & NOISE (max.) Note.3 50mVp-p 100mVp-p 100mVp-p 50mVp-p 25W 100mVp-p 100mVp-p 50mVp-p VOLTAGE ADJ. RANGE Fixed VOLTAGE TOLERANCE Note.4 5.0% 5.0% 3.0% 5.0% 5.0% 3.0% 5.0% 5.0% 3.0% LINE REGULATION Note.5 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% LOAD REGULATION Note.6 4.0% 4.0% 2.0% 4.0% 4.0% 2.0% 4.0% 4.0% 2.0% SETUP, RISE, HOLD UP TIME 200ms, 50ms, 16ms at full load INPUT VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 70% AC CURRENT INRUSH CURRENT (max.) 0.8A / 100VAC 60A / 230VAC 0.75mA / 240VAC OVERLOAD 110 ~ 140% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover WORKING TEMP. 0 ~ +40 WORKING HUMIDITY 20% ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC EMI CONDUCTION & RADIATION (Note. 7) HARMONIC CURRENT NOTE 74% 150 ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE CONNECTOR 72% LEAKAGE CURRENT (max.) PROTECTION OTHERS 135 ~ 370VDC EMS IMMUNITY MTBF DIMENSION -20 ~ +85 0.03% / (Refer to output load derating curve) , 10 ~ 95% RH (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1950, CSA22.2, EN60950-1 Approved I/P-O/P:3KVAC , I/P-FG:1.5KVAC I/P-O/P,I/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022(CISPR22) class B Compliance to EN61000-3-2,3 class A Compliance to EN61000-4-2,3,4,5,6,11, Light industry level, criteria A 520K hrs min. MIL-HDBK-217F (25 ) 108*67*36mm (L*W*H) 0.3kg ; 54pcs/ 20kg / CARTON PACKING PLUG Standard type R1B: DIN 5PIN for stock ; Other type available by customer requested CABLE Standard type UL2464 18AWG*3C 20AWG*2C shield wire *1C with 5fts length for stock ; Other type available by customer requested 1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.Tolerance: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.Load regulation is measured from 20% to 100% rated load. 7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:P25A-T-SPEC 2007-03-01 P25A-T 25W AC-DC Triple Output Desktop Mechanical Specification series Unit:mm 36 UL2464 18AWG 1530+100/-0 MALE CABLE PLUG 106 36 54.8 67 SWITCHING ADAPTOR 10.2 POWER LED 108 Plug Assignment 69.9 18 Standard plug: R1B (option) 33.5 PIN NO OUTPUT 1 3 R1 AC FG 1 o COM 2 COM 3 +5VDC 4 -Vout 5 +Vout RUBBER FOOTX4 NAME PLATE Derating Curve Static Characteristics 100 LOAD (%) 100 LOAD (%) 45 5 2 4 67 45 42 3 70 0 10 20 Ta ( 30 ) 40 80 60 0 60 70 80 90 100 260 INPUT VOLTAGE File Name:P25A-T-SPEC 2007-03-01