ETC P5KE15CA

SCOTTSDALE DIVISION
Medium Power Zener and Transient Voltage
Protection Axial Lead Series Reliability &
Qualification Data
This is the reliability and qualification data for the Medium Power Transient Voltage
Suppression Series.
Features
Molded axial lead
400-1.5K Watts Peak Pulse Power Dissipation
Stand Off Voltages from 5.5V – 400V
Mechanical
Weight: 1.5 grams maximum
Polarity: Marked with Band
Unipolar or Bipolar
Maximum Ratings
400-1.5K Watts of Peak Pulse Power Dissipation
Operating Temperatures: -65° C to 175° C
Storage Temperature: -65° C to 175° C
Forward Surge Rating: 200Amps (1/20 second)
Steady State Power Dissipation 5.0 W @ TL= 75°C
Stress
Moisture Classification
ESD Sensitivity
Steady State Life
Temperature Cycle
High Temperature Reverse Bias
Humidity
Results
Level 1 Package - No Drypack Required
Non-sensitive – No special handling required
0/50 @ 25° C (1000 Hours)
0/350 @ 1000 temp cycles (65° C to 200° C)
0/350 @ 125° C (1000 Hours)
0/200 @ 85° C 85% Humidity (1000 hours)
1.5KE1302
Series: P4KE, P5KE, P6KE, 1EZ, 2EZ, 3EZ Series
1N6267-1N6303A, 1N5913-1N5956
1.5KE6.8-1.5KE400A
SAC5.0-SAC50, SA5-SA170 and C
GMP-5, 1N5333-1N5388,1N4728-1N4764
John Freeman
Director of Engineering
Bill Jones
Director of Quality Control and
Reliability Assurance