PDU53 data 3 delay devices, inc. 3-BIT, ECL-INTERFACED PROGRAMMABLE DELAY LINE (SERIES PDU53) FEATURES • • • • • PACKAGES Digitally programmable in 8 delay steps Monotonic delay-versus-address variation Precise and stable delays Input & outputs fully 100K-ECL interfaced & buffered Available in 16-pin DIP (600 mil) socket or SMD N/C 1 16 IN N/C 2 15 A2 GND 3 14 A1 OUT 4 13 VEE N/C 5 12 A0 N/C 6 11 N/C N/C 7 10 N/C N/C 8 9 N/C PDU53-xx DIP PDU53-xxM Military DIP N/C N/C GND OUT N/C N/C N/C N/C 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 IN A2 A1 VEE A0 N/C N/C N/C PDU53-xxC3 SMD PDU53-xxMC3 Mil SMD FUNCTIONAL DESCRIPTION PIN DESCRIPTIONS The PDU53-series device is a 3-bit digitally programmable delay line. The delay, TDA, from the input pin (IN) to the output pin (OUT) depends on the address code (A2-A0) according to the following formula: IN OUT A2 A1 A0 VEE GND TDA = TD0 + TINC * A Signal Input Signal Output Address Bit 2 Address Bit 1 Address Bit 0 -5 Volts Ground where A is the address code, TINC is the incremental delay of the device, and TD0 is the inherent delay of the device. The incremental delay is specified by the dash number of the device and can range from 100ps through 3000ps, inclusively. The address is not latched and must remain asserted during normal operation. SERIES SPECIFICATIONS • • • • • • • • • DASH NUMBER SPECIFICATIONS Total programmed delay tolerance: 5% or 40ps, whichever is greater Inherent delay (TD0): 2.2ns typical Address to input setup (TAIS): 2.9ns Operating temperature: 0° to 85° C Temperature coefficient: 100PPM/°C (excludes TD0) Supply voltage VEE: -5VDC ± 0.7V Power Supply Current: -150ma typical (50Ω to -2V) Minimum pulse width: 3ns or 15% of total delay, whichever is greater Minimum period: 8ns or 2 x pulse width, whichever is greater A2-A0 A i-1 PW IN Ai TOAX TAIS Part Number PDU53-100 PDU53-200 PDU53-250 PDU53-400 PDU53-500 PDU53-750 PDU53-1000 PDU53-1200 PDU53-1500 PDU53-2000 PDU53-2500 PDU53-3000 Incremental Delay Per Step (ps) 100 ± 50 200 ± 60 250 ± 60 400 ± 80 500 ± 100 750 ± 100 1000 ± 200 1200 ± 200 1500 ± 200 2000 ± 400 2500 ± 400 3000 ± 500 Total Delay Change (ns) 0.70 1.40 1.75 2.80 3.50 5.25 7.00 8.40 10.50 14.00 17.50 21.00 NOTE: Any dash number between 100 and 3000 not shown is also available. IN TDA PW OUT OUT Figure 1: Timing Diagram 1997 Data Delay Devices Doc #98003 3/18/98 DATA DELAY DEVICES, INC. 3 Mt. Prospect Ave. Clifton, NJ 07013 1 PDU53 APPLICATION NOTES conditions are those for which the delay tolerance specifications and monotonicity are guaranteed. The suggested conditions are those for which signals will propagate through the unit without significant distortion. The absolute conditions are those for which the unit will produce some type of output for a given input. ADDRESS UPDATE The PDU53 is a memory device. As such, special precautions must be taken when changing the delay address in order to prevent spurious output signals. The timing restrictions are shown in Figure 1. When operating the unit between the recommended and absolute conditions, the delays may deviate from their values at low frequency. However, these deviations will remain constant from pulse to pulse if the input pulse width and period remain fixed. In other words, the delay of the unit exhibits frequency and pulse width dependence when operated beyond the recommended conditions. Please consult the technical staff at Data Delay Devices if your application has specific high-frequency requirements. After the last signal edge to be delayed has appeared on the OUT pin, a minimum time, TOAX, is required before the address lines can change. This time is given by the following relation: TOAX = max { (Ai - A i-1) * TINC , 0 } where A i-1 and Ai are the old and new address codes, respectively. Violation of this constraint may, depending on the history of the input signal, cause spurious signals to appear on the OUT pin. The possibility of spurious signals persists until the required TOAX has elapsed. Please note that the increment tolerances listed represent a design goal. Although most delay increments will fall within tolerance, they are not guaranteed throughout the address range of the unit. Monotonicity is, however, guaranteed over all addresses. INPUT RESTRICTIONS There are three types of restrictions on input pulse width and period listed in the AC Characteristics table. The recommended PACKAGE DIMENSIONS 16 15 14 13 12 11 10 9 .600 ±.00 .580 MAX. .010 ±.002 1 2 3 4 5 6 7 8 .870±.010 .380 MAX. Lead Material: Nickel-Iron alloy 42 TIN PLATE .015 TYP. .018 TYP. .070 MAX. .700±.010 7 Equal spaces each .100±.010 Non-Accumulative PDU53-xx (Commercial DIP) PDU53-xxM (Military DIP) Doc #98003 3/18/98 DATA DELAY DEVICES, INC. Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com 2 PDU53 PACKAGE DIMENSIONS (cont’d) .020 TYP. .040 TYP. 16 15 14 13 12 11 10 .010±.002 9 .882 ±.00 .710 .590 ±.00 MAX. 1 2 3 4 5 6 .090 7 .007 ±.00 8 .100 .380 MAX. .700 .880±.020 .050 ±.01 PDU53-xxC3 (Commercial SMD) PDU53-xxMC3 (Military SMD) DEVICE SPECIFICATIONS TABLE 1: AC CHARACTERISTICS PARAMETER Total Programmable Delay Inherent Delay Address to Input Setup Time Output to Address Change Absolute Input Period Suggested Recommended Absolute Input Pulse Width Suggested Recommended SYMBOL TDT TD0 TAIS TOAX PERIN PERIN PERIN PWIN PWIN PWIN MIN TYP 7 2.2 2.9 See Text 30 50 200 15 25 100 UNITS TINC ns ns % of TDT % of TDT % of TDT % of TDT % of TDT % of TDT TABLE 2: ABSOLUTE MAXIMUM RATINGS PARAMETER DC Supply Voltage Input Pin Voltage Storage Temperature Lead Temperature SYMBOL VEE VIN TSTRG TLEAD MIN -7.0 VEE - 0.3 -65 MAX 0.3 0.3 150 300 UNITS V V C C NOTES 10 sec TABLE 3: DC ELECTRICAL CHARACTERISTICS (0C to 85C) PARAMETER High Level Output Voltage Low Level Output Voltage High Level Input Voltage Low Level Input Voltage High Level Input Current Low Level Input Current Doc #98003 3/18/98 SYMBOL VOH VOL VIH VIL IIH IIL MIN -1.025 -1.810 -1.165 -1.810 0.5 MAX -0.880 -1.620 -0.880 -1.475 340 UNITS V V V V µA µA DATA DELAY DEVICES, INC. 3 Mt. Prospect Ave. Clifton, NJ 07013 NOTES VIH = MAX,50Ω to -2V VIL = MIN, 50Ω to -2V VIH = MAX VIL = MIN 3 PDU53 DELAY LINE AUTOMATED TESTING TEST CONDITIONS INPUT: Ambient Temperature: 25oC ± 3oC Supply Voltage (Vcc): -4.5V ± 0.1V Input Pulse: Standard 100K ECL levels Source Impedance: 50Ω Max. Rise/Fall Time: 1.0 ns Max. (measured between 20% and 80%) Pulse Width: PWIN = 10ns Period: PERIN = 100ns OUTPUT: Load: Cload: Threshold: 50Ω to -2V 5pf ± 10% (VOH + VOL) / 2 (Rising & Falling) NOTE: The above conditions are for test only and do not in any way restrict the operation of the device. REF PULSE GENERATOR OUT IN TRIG DEVICE UNDER TEST (DUT) OUT IN OSCILLOSCOPE TRIG ADDRESS SELECT Test Setup PERIN PW IN TRISE INPUT SIGNAL TFALL VIH 80% 50% 20% 80% 50% 20% TRISE OUTPUT SIGNAL VIL TFALL 50% VOH 50% VOL Timing Diagram For Testing Doc #98003 3/18/98 DATA DELAY DEVICES, INC. Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com 4