RSG PFC400-51B

RSG
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
Tel. +49 69 984047-0 Fax +49 69 984047-77 [email protected] www.rsg-electronic.de
■
■
ELECTRONIC COMPONENTS
■
■
■
■
Änderungen vorbehalten / subject to change without notice
400 WATT POWER FACTOR CORRECTED SUPPLIES
PFC400 SERIES
DESCRIPTION
(LVD)
The PFC400 series of AC/DC switching power supplies are capable of
delivering 400 watts of continuous power and incorporate active power
factor correction. Three outputs in each unit are equipped with current
sharing and oring diode for redundant applications. Other features
include remote sense, Power Fail Detect signal and isolated outputs.
The units are constructed on a printed circuit board with a U-bracket
for mechanical support and heat sinking. The series is designed for use
in medium-power data networking, telecom, industrial, test and office
equipment.
F E ATU R E S
•
•
•
•
•
•
•
•
P o w e r F a c t o r 0.98 typical
9 0 VA C t o 2 6 4 VA C u n i v e r s a l i n p u t
Current sharing, oring diodes and remote sense
In compliance with EN 61000-3-2/-3 and EN 55024
( E N 6 1 0 0 0 - 4 - 2 / - 3 / - 4 / - 5 / - 6 / - 8 / - 11 )
Tightly regulated DC outputs
Overvoltage and thermal protection
Short-circuit protection
Power Fail Detect (PFD) signal
S a f e t y St a n d a r d A p p ro v a ls :
TÜV EN60950-1
Certificate No. R3-50006876
I N P U T S P E C I F I C ATI O N S
E N V I R O N M E N TA L S P E C I F I C ATI O N S
Input voltage:
9 0 t o 2 6 4 VA C
Input frequency:
Input current:
47 to 63 Hz
7 . 1 A ( r m s ) f o r 11 5 VA C
3 . 2 A ( r m s ) f o r 2 3 0 VA C
0 . 4 6 m A m a x . @ 11 5 VA C , 6 0 H z
0 . 8 m A m a x . @ 2 3 0 VA C , 5 0 H z
Operating temperature:
St o r a g e t e m p e r a t u r e :
Relative humidity:
Derating:
Leakage current:
OUTPUT SPECIFICATIONS
Cooling:
0℃ to +70℃
-40℃ to +85℃
5﹪ to 95﹪ non-condensing
Derate from 100﹪ at +50℃
linearly to 50﹪ at +70℃
4 5 . 2 C F M f o r c e d a i r,
provided by user
GENERAL SPECIFICATIONS
Output voltage/current:
See rating chart
Switching frequency: 94KHz ±5KHz
Total output power:
400 watts maximum
Power factor:
0.98 typical
Ripple and noise:
2﹪ peak to peak maximum
Overvoltage protection:
Provided on output #1 only; set
at 112-132﹪ of its nominal
output voltage
Efficiency:
Hold-up time:
Line regulation:
70% typical
12 msec min. at 115VAC
±0.5﹪ max. at full load
Overcurrent protection:
All outputs protected to short
circuit conditions
Temperature coefficient:
All outputs ±0.04﹪ /℃
maximum
Transient response:
Maximum excursion of 4﹪ or
better on all models; recovering
to 1﹪ of final value within
500us after a 25﹪ step load
change
PFD signal:
TTL logic high for normal
operation and TTL logic low
upon loss of input power. This
signal appears at least 1 ms
prior to +5.1V output dropping
5% below its nominal value.
This signal also provides a
minimum delay of 100 ms after
+5.1V is within regulation.
1-33
Inrush current:
43A @ 115VAC, or 86A @ 230VAC, at 25
℃ cold start
Withstand voltage:
3000VAC from input to output 1500VAC
from input to ground
500VAC from output to ground
MTBF:
250,000 hours minimum at full load at 25℃
ambient, calculated per MIL-HDBK-217F
EMC performance (EN55024)
EN55022:
Class B conducted, Class A radiated
FCC:
Class B conducted, Class A radiated
VCCI:
Class B conducted, Class A radiated
EN61000-3-2:
Harmonic distortion, Class A and D
EN61000-3-3:
Line flicker
EN61000-4-2:
ESD, ± 8KV air and ± 4KV contact
EN61000-4-3:
Radiated immunity, 3V/m
EN61000-4-4:
Fast transient/burst, ± 1KV
EN61000-4-5:
Surge, ± 1KV diff., ± 2KV com.
EN61000-4-6:
Conducted immunity, 3Vrms
EN61000-4-8:
Magnetic field immunity, 1A/m
EN61000-4-11:
Voltage dips, 30% reduction for 500ms and
> 95% reduction for 10ms
PFC400 SERIES
UNIVERSAL INPUT
OUTPUT VOLTAGE/CURRENT RATING CHART
(1)
Model (1)
PFC400-50B
PFC400-51B
PFC400-55B
PFC400-56B
Notes:
Output #1 (2)(3)
Output #2 (2)(4)
Vnom. Imax. Tol. Vnom. Imax. Tol.
+5.1V
40A
2% 3.3V
20A 2%
+5.1V
40A
2% 3.3V
20A 2%
+5.1V
40A
2% 3.3V
20A 2%
+5.1V
40A
2% 3.3V
20A 2%
Output #3 (2)(5)
Vnom. Imax. Tol.
12V
9A
3%
15V
8A
3%
12V
9A
3%
15V
8A
3%
Output #4
Vnom. Imax.
12V
6A
15V
5A
12V
6A
15V
5A
Output #5
Vnom. Imax.
5V
6A
24V
4A
24V
4A
5V
6A
Tol.
4%
4%
4%
4%
Maximum
Output
Power(6)
400W
400W
400W
400W
Tol.
4%
4%
4%
4%
(1) Each output is isolated from the others and has individual return.
(2) Output #1, #2, and #3 are built with one-wire current sharing and oring diode for redundant connections.
(3) Output #1 requires a minimum load of 5A to support other outputs at their maximum rated loads.
(4) Output #2 requires a minimum load of 1A to be in regulation.
(5) The peak current of output #3 is limited to 12A on 12V, 9.6A on 15V.
(6) Forced air cooling of 45.2 CFM minimum is required.
Suggested airflow is from the input section to the output section.
MECHANICAL SPECIFICATIONS
NOTES:
1. Dimensions shown in inch [mm]
2. Tolerance 0.02 [0.5] maximum
3. P1 input connector is Beau Inc. P/N
72-5-03C. Screws are #6-32 on 0.375 inch
(9.53mm) centers.
4. P4 output connector is Dinkle P/N
166-06P.
5. P8 is for DC fan rated 12V/0.25A
6. P8 & P9 Connector mates with Molex
housing. 22-01-1023 and Molex 40445
series crimp terminal.
7. Main output studs P2/P3 are with M5*0.8
screws.
8. Weight: 1.70Kgs (3.74 Lbs.) approx.
PIN CHART
CONN
P1
P4
P2
PIN
MODEL
1
PFC400-50B
PFC400-51B LIVE
PFC400-55B
PFC400-56B
2
3
NEUTRAL GROUND
P5
P8
P9
P3
1
2
3
4
5
6
1
2
1
OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT
#1
#1 RET.
#5
#5 RET.
#4
#4 RET.
#3
#3 RET.
#2
#2 ret.
CB4 SUB-BOARD
(for output #1)
CB6 SUB-BOARD
(for output #3)
FAN
(+12V)
2
1
OUTPUT#1 OUTPUT
ret.
#1 ret.
2
PFD
CB7 SUB-BOARD
(for output #2)
P4-1
+SENSE
P3-1
+SENSE
P3-1
+SENSE
P4-2
-SENSE
P3-2
-SENSE
P3-2
-SENSE
P4-3
CURRENT SHARE
P3-3
CURRENT SHARE
P3-3
CURRENT SHARE
1-34