PMI PM-CI07

P Premier
M Magnetics Inc.
PM-CIXX
CURRENT SENSE
INDUCTORS
"INNOVATORS IN MAGNETICS TECHNOLOGY"
! Designed for Switch Mode Power Supply Applications " Tapped and Untapped Versions
# Frequency Range from 10KHz to 200KHz
$ 2500Vrms Minimum Isolation Voltage
% Fully Encapsulated Construction
& Center Hole for Primary Lead
ELECTRICAL SPECIFICATIONS AT 25OC - OPERATING TEMPERATURE RANGE -40OC TO +80OC
CONTROL VALUES
REFERENCE VALUES
CALC. VALUES
INDUCTANCE
DCR
RT
KV
LS
RS
DROOP
IPK
(mH Min.)
(Ohms Max.) (Amps) (Ohms) (Volt/Amp)
(%)
PART
NUMBER
TURNS
NS + 1%
PM-CI01
PM-CI02
PM-CI03
PM-CI04
50
100
200
300
5.0
20.0
80.0
180.0
0.70
1.40
4.50
9.00
35
50
50
75
15
50
200
300
0.30
0.50
1.00
1.00
PM-CI05
PM-CI06
PM-CI07
PM-CI08
50ct
100ct
200ct
300ct
5.0
20.0
80.0
180.0
0.70
1.40
4.50
9.00
35
50
50
75
15
50
200
300
0.30
0.50
1.00
1.00
LOSS
FACTOR
KL
FLUX
FACTOR
KB
SCHEMATIC
2.4
2.0
2.0
1.4
273.97x10
68.49x103
17.12x103
7.61x103
3
-9
3.31x10
3.33x10-9
3.35x10-9
3.37x10-9
A
A
A
A
2.4
2.0
2.0
1.4
273.97x103
68.49x103
17.12x103
7.61x103
3.31x10-9
3.33x10-9
3.35x10-9
3.37x10-9
B
B
B
B
REFER TO CALCULATION EXAMPLE FOR PM-CIXX SERIES ON PAGE 2 OF THIS DATA SHEET.
1) REFERENCE VALUES ARE FOR UNIPOLAR OPERATION @ 50KHz, 40% DUTY CYCLE (Dmax = .40).
2) THE MAXIMUM USABLE PEAK SENSE CURRENT (Ipk) IS DEPENDENT ON CORE SATURATION FACTORS AND SHOULD BE
EVALUATED FOR THE ACTUAL OPERATING CONDITIONS. SEE APPLICATION DATA AND EXAMPLE ON PAGE 51.
3) THE MAXIMUM RECOMMENDED OPERATING FLUX DENSITY (BOP) @ AN OPERATING TEMPERATURE OF 105OC IS 2000 GAUSS.
4) THE TERM. RESISTOR (Rt) CAN BE VARIED TO ADJUST THE OPERATING FLUX DENSITY (BOP), DROOP, AND SCALE FACTOR (KV).
5) THE SCALE FACTOR (KV) IS PROPORTIONAL TO THE TERMINATING RESISTOR (RT) AND IS EQUAL TO 1VOLT/AMP WHEN RT = NS
6) SECONDARY INDUCTANCE IS MEASURED AT 20KHz, 1.0VRMS.
MECHANICAL
SCHEMATIC
SCHEMATIC "A"
PHYSICAL Dimensions in inches (mm)
.410
(10.4)
MAX
1
.180 DIA.
(4.57) MIN
.35
(8.8)
.838
(21.3)
MAX
3
1
2
SCHEMATIC "B"
1
2
3
∅
.040
(1.02)
LEAD 2 PRESENT
ON CENTER TAPPED
VERSION ONLY
ARROW INDICATES
CURRENT FLOW
PIN#1 IN PHASE
P PM-CIXX
M
YYWW
.500
(12.70)
.030
(.762)
.250
(6.35)
3
.19
(4.8)
3
Specifications subject to change without notice.
pmci 4/97
20381 BARENTS SEA CIRCLE, LAKE FOREST, CA 92630 • TEL: (949) 452-0511 • FAX: (949) 452-0512 • http://www.premiermag.com
1
P Premier
M Magnetics Inc.
PM-CIXX
CURRENT SENSE
INDUCTORS
"INNOVATORS IN MAGNETICS TECHNOLOGY"
APPLICATION EXAMPLE
APPLICATION EXAMPLE
GIVEN:
Part# = PM-CI02
Peak Current (IPK) = 30.0 Amps
Terminating Resistor (RT) = 100 Ohms
Operating Frequency (f) = 100KHz
Duty Cycle (Dmax) = .40 (40% on time)
CALCULATE THE SCALE FACTOR
From the Table the Secondary Turns are:
NS = 100
THEN:
KV = RT / NS
= 100 / 100
= 1 volt/amp
CALCULATE OPERATING FLUX DENSISTY
From the Table the FLUX FACTOR is:
KB = 68.49 x 103
ESTIMATE ERROR DUE TO LOSSES
From the Table the Secondary DCR is:
RS = 1.40 Ohms Maximum
Flux Utilization Constant (KF) is:
1.0 For Unipolar Operation
2.0 For Bipolar Operation
From the Table the approximate Loss Factor is:
KL = 3.33 x 10-9
THEN:
BOP = KB x IPK x RT x (Dmax / KF x f)
Note: The loss factor (KL) is valid approximation
from10KHz to 200KHz
= 68.49x103 x 30 x 100 x (.4 / 1 x 100x103)
Secondary Copper Losses are:
P_lossS = (IPK / NS )2 x RS
= 822 gauss (OK less than 2000 gauss)
= (30/100)2 x 1.40
CALCULATE PULSE DROOP
= 0.126 Watt
From the Table the Secondary Inductance is:
LS = 20mHy Minimum
Core losses are:
P_lossC = KL2 x f1.621 x BOP2.569
Note: The actual droop is dependent on the actual LS
in the circuits enviorment.
= (3.33x10-9)2 x (100x103)1.621 x 8222.569
= 0.0435 Watt
Droop Exponent (D) = RT x Dmax / (LS x f)
Output Power is:
= 100 x .4 / (20x10-3 x 100x103)
P_outS
= (IPK / NS )2 x RT
= 0.020
= (30/100)2 x 100
THEN:
%_Droop = (1-e-D) x 100
= 1.98 %
OK less than 10%
(Depending on the application
Droop to 20% may be acceptable)
= 9.00 Watt
THEN:
%_Error
= [(P_lossS + P_lossC ) / P_out] x 100
= [(.126 + .0435) / 9] x 100
= 1.88 %
Specifications subject to change without notice.
pmci 4/97
20381 BARENTS SEA CIRCLE, LAKE FOREST, CA 92630 • TEL: (949) 452-0511 • FAX: (949) 452-0512 • http://www.premiermag.com
2