POWEREX PM1200HCE330-

PM1200HCE330-1
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
High Voltage Intelligent
Power Module
1200 Amperes/3300 Volts
G
TERMINAL ARRANGEMENT
CONTROL CONNECTOR
V1
VC
U
(8 PLACES)
G
F
FO
ST
CI
6 5
4 3
NC
C
C
C
2 1
S E C B
P
N
E
R
E
E
G
E
M
J
K
D
H
T (8 PLACES)
L
D
D
A
V (2 PLACES)
AA
W
Z
X
Y
CONTROL
CONNECTOR
FEMALE
(TYPE
IL-AG5-6S-S3C1)
LABEL
E
G
C
ASIC
CONTROL
LOGIC
CI
PROTECTION
LOGIC
FO
VC
CONTROL
CIRCUIT
GROUND
R.T.C.
(REAL TIME
CONTROL)
OC/SC
INPUT
INTERFACE
CONNECTOR
GATE DRIVE
IGBT
FWDI
CURRENT
SENSOR
OT
THERMAL
SENSOR
UV
POWER
FAILURE
DETECTOR
MAIN
CIRCUIT
TO CONTROL CIRCUIT
VI
E
Outline Drawing and Circuit Diagram
Dimensions
Inches
Millimeters
Dimensions
Inches
A
7.48±0.012
190.0±0.3
N
1.61
Millimeters
41.0
B
5.51±0.012
140.0±0.3
P
0.62
15.85
C
4.88±0.012
124.0±0.3
R
0.72
18.3
D
2.24±0.012
57.0±0.3
S
0.59
15.0
E
1.57
40.0
T
0.26
6.5
Description:
Powerex High Voltage Intelligent
Power Module combines gate drive
and protection circuitry in a fully
isolated package. The new HVIPM
reduces the saturation voltage by
7.5% while maintaining high short
circuit withstanding capability. Gate
drive noise is resolved through the
use of the HVIPM by optimizing the
control of the chip through close
proximity of the gate drive control
circuit.
Features:
□ Control Circuit and Protection
Circuitry for Overcurrent,
Short Circuit and Overtemperature
□ Low VCE(sat) 7.5%
Reduction Versus HVIGBT
□ Exterior Package Matches
Standard HVIGBT
□ Optimized Isolation Design to
Satisfy 6KV AC.
Applications:
□ High Power Converters
and Inverters
□ Medium Voltage Drives
□ Traction Drives
Ordering Information:
Example: Select the complete
module number you desire from
the table - i.e. PM1200HCE330-1
is a 1200V (VCES), 3300 Ampere
High Voltage Power Module.
F
0.51
13.0
U
M8
M8
G
2.42±0.012
61.5±0.3
V
M3
M3
H
0.65
16.5
W
1.50 +0.4/-0.0
38.0 +1.0/-0.0
J
0.55
14.0
X
0.37
9.3
K
1.77
45.0
Y
0.10
2.6
L
0.67
17.0
Z
0.91
23.0
Type
Current Rating (A)
VCES (V)
M
0.59
15.0
AA
0.43
11.0
PM
3300
1200
1
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PM1200HCE330-1
High Voltage Intelligent Power Module
1200 Amperes/3300 Volts
Absolute Maximum Ratings, Tj = 25°C unless otherwise specified
Ratings
Symbol
PM1200HCE330-1
Units
Junction Temperature
Tj
-40 to 150
°C
Storage Temperature
Tstg
-40 to 115
°C
Mounting Torque, M6 Mounting Screws
–
30
in-lb
Mounting Torque, M8 Main Terminal Screw
–
95
in-lb
Mounting Torque, M3 Auxiliary Terminal Screw
–
5
in-lb
Weight (Typical)
–
1.5
kg
Viso
6000
Volts
Isolation Voltage (Main Terminal to Baseplate, AC 1 min.)
Control Part
Supply Voltage Applied between V1 ~ VC
VD
26.4
Volts
Input Voltage Applied between C1 ~ VC
VCIN
26.4
Volts
Fault Output Supply Voltage Applied between FO-VC
VFO
26.4
Volts
Fault Output Current (Sink Current at FO Terminals)
IFO
20
mA
VCES
3300
Volts
IC
1200
Amperes
ICP
2400
Amperes
Inverter Part
Collector-Emitter Voltage
Collector Current
Peak Collector Current
2
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PM1200HCE330-1
High Voltage Intelligent Power Module
1200 Amperes/3300 Volts
ElectricalCharacteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
21.6
24.0
26.4
—
80
Units
Control Part
Supply Voltage
Circuit Current
VD
Applied between V1 ~ VC
ID
VD = 24V, Tj = 25°C
Input ON Threshold Voltage
Vth(on)
Applied between C1 ~ VC
Input OFF Threshold Voltage
Vth(off)
6.1
10.5
—
6.7
11.1
100
120
Volts
mA
7.3
Volts
11.7
Volts
Minimum Fault Output Pulse Width
tFO
VD = 24V
200
Overcurrent Trip Level
OC
Tj = -25°C ~ 125°C
2200
—
—
Overtemperature Protection
OT
Trip Level
103
113
123
(Baseplate Temperature Detection)
OTr
Reset Level
108
Supply Circuit Undervoltage Protection
UV
Trip Level
(Tj = -25°C ~ 125°C)
UVr
VCE(sat)
µs
Amperes
°C
°C
88
98
19.2
20.0
20.8
Volts
Reset Level
—
20.5
—
Volts
IC = 1200A, Tj = 25°C
—
Inverter Part
Collector-Emitter Saturation Voltage
3.05
2.90
3.97
Volts
3.77
Volts
FWDi Forward Voltage
VEC
-IC = 1200A, Tj = 25°C
—
Collector Cutoff Current
ICES
VCE = VCES, Tj = 25°C
—
—
15
mA
VCE = VCES, Tj = 125°C
—
—
60
mA
3
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PM1200HCE330-1
High Voltage Intelligent Power Module
1200 Amperes/3300 Volts
Thermal Characteristics
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Thermal Resistance, Junction to Case
Rth(j-c)Q
Per IGBT
—
0.0083
0.0100 °C/W
Thermal Resistance, Junction to Case
Rth(j-c)D
Per FWDi
—
0.0167
0.0200 °C/W
Rth(c-f)
Per Module, Thermal Grease Applied
—
0.0075 —
Symbol
Test Conditions
Contact Thermal Resistance
°C/W
Recommended Conditions for Use
Characteristics
Min.
Typ.
Inverter Supply Voltage
VCC
Applied between C-E
0
Control Supply Voltage
VD
Applied between V1-VC
21.6
Input ON Voltage
VCIN(on)
Applied between C1-VC
0
—
Input OFF Voltage
VCIN(off)
—
16.0
—
PWM Input Frequency
fPWM
3 Phase Sinsusoidal PWM Control
Arm Shoot-though Blocking Time
tDEAD
Reference at IPM's Input Terminals
COLLECTOR-EMITTER
SATURATION VOLTAGE CHARACTERISTICS
(TYPICAL)
3
2
1
0
3
2
1
Tj = 25°C
Tj = 125°C
500
1000
1500
COLLECTOR CURRENT, IC, (AMPERES)
2000
Volts
—
Volts
2.0
kHz
µs
—
VCC = 1500V
IC/-IC = 1200A
Tj = 125°C
EON
2
EOFF
EREC
1
0
0
0
4.0
3
SWITCHING ENERGY, EON/EOFF/EREC, (J/PULSE)
EMITTER COLLECTOR VOLTAGE, VEC, (VOLTS)
COLLECTOR-EMITTER
SATURATION VOLTAGE, VCE(sat), (VOLTS)
4
Volts
SWITCHING ENERGY CHARACTERISTICS
(TYPICAL)
4
VGE = 15V
Tj = 25°C
Tj = 125°C
Volts
26.4
VD
0.5
8.0
Units
2200
24.0
—
FREE-WHEEL DIODE
FORWARD CHARACTERISTICS
(TYPICAL)
5
1500
Max.
0
500
1000
1500
EMITTER CURRENT, IE, (AMPERES)
2000
0
500
1000
1500
EREC EMITTER CURRENT, IE, (AMPERES)
4