PM1200HCE330-1 Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 High Voltage Intelligent Power Module 1200 Amperes/3300 Volts G TERMINAL ARRANGEMENT CONTROL CONNECTOR V1 VC U (8 PLACES) G F FO ST CI 6 5 4 3 NC C C C 2 1 S E C B P N E R E E G E M J K D H T (8 PLACES) L D D A V (2 PLACES) AA W Z X Y CONTROL CONNECTOR FEMALE (TYPE IL-AG5-6S-S3C1) LABEL E G C ASIC CONTROL LOGIC CI PROTECTION LOGIC FO VC CONTROL CIRCUIT GROUND R.T.C. (REAL TIME CONTROL) OC/SC INPUT INTERFACE CONNECTOR GATE DRIVE IGBT FWDI CURRENT SENSOR OT THERMAL SENSOR UV POWER FAILURE DETECTOR MAIN CIRCUIT TO CONTROL CIRCUIT VI E Outline Drawing and Circuit Diagram Dimensions Inches Millimeters Dimensions Inches A 7.48±0.012 190.0±0.3 N 1.61 Millimeters 41.0 B 5.51±0.012 140.0±0.3 P 0.62 15.85 C 4.88±0.012 124.0±0.3 R 0.72 18.3 D 2.24±0.012 57.0±0.3 S 0.59 15.0 E 1.57 40.0 T 0.26 6.5 Description: Powerex High Voltage Intelligent Power Module combines gate drive and protection circuitry in a fully isolated package. The new HVIPM reduces the saturation voltage by 7.5% while maintaining high short circuit withstanding capability. Gate drive noise is resolved through the use of the HVIPM by optimizing the control of the chip through close proximity of the gate drive control circuit. Features: □ Control Circuit and Protection Circuitry for Overcurrent, Short Circuit and Overtemperature □ Low VCE(sat) 7.5% Reduction Versus HVIGBT □ Exterior Package Matches Standard HVIGBT □ Optimized Isolation Design to Satisfy 6KV AC. Applications: □ High Power Converters and Inverters □ Medium Voltage Drives □ Traction Drives Ordering Information: Example: Select the complete module number you desire from the table - i.e. PM1200HCE330-1 is a 1200V (VCES), 3300 Ampere High Voltage Power Module. F 0.51 13.0 U M8 M8 G 2.42±0.012 61.5±0.3 V M3 M3 H 0.65 16.5 W 1.50 +0.4/-0.0 38.0 +1.0/-0.0 J 0.55 14.0 X 0.37 9.3 K 1.77 45.0 Y 0.10 2.6 L 0.67 17.0 Z 0.91 23.0 Type Current Rating (A) VCES (V) M 0.59 15.0 AA 0.43 11.0 PM 3300 1200 1 Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 PM1200HCE330-1 High Voltage Intelligent Power Module 1200 Amperes/3300 Volts Absolute Maximum Ratings, Tj = 25°C unless otherwise specified Ratings Symbol PM1200HCE330-1 Units Junction Temperature Tj -40 to 150 °C Storage Temperature Tstg -40 to 115 °C Mounting Torque, M6 Mounting Screws – 30 in-lb Mounting Torque, M8 Main Terminal Screw – 95 in-lb Mounting Torque, M3 Auxiliary Terminal Screw – 5 in-lb Weight (Typical) – 1.5 kg Viso 6000 Volts Isolation Voltage (Main Terminal to Baseplate, AC 1 min.) Control Part Supply Voltage Applied between V1 ~ VC VD 26.4 Volts Input Voltage Applied between C1 ~ VC VCIN 26.4 Volts Fault Output Supply Voltage Applied between FO-VC VFO 26.4 Volts Fault Output Current (Sink Current at FO Terminals) IFO 20 mA VCES 3300 Volts IC 1200 Amperes ICP 2400 Amperes Inverter Part Collector-Emitter Voltage Collector Current Peak Collector Current 2 Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 PM1200HCE330-1 High Voltage Intelligent Power Module 1200 Amperes/3300 Volts ElectricalCharacteristics, Tj = 25°C unless otherwise specified Characteristics Symbol Test Conditions Min. Typ. Max. 21.6 24.0 26.4 — 80 Units Control Part Supply Voltage Circuit Current VD Applied between V1 ~ VC ID VD = 24V, Tj = 25°C Input ON Threshold Voltage Vth(on) Applied between C1 ~ VC Input OFF Threshold Voltage Vth(off) 6.1 10.5 — 6.7 11.1 100 120 Volts mA 7.3 Volts 11.7 Volts Minimum Fault Output Pulse Width tFO VD = 24V 200 Overcurrent Trip Level OC Tj = -25°C ~ 125°C 2200 — — Overtemperature Protection OT Trip Level 103 113 123 (Baseplate Temperature Detection) OTr Reset Level 108 Supply Circuit Undervoltage Protection UV Trip Level (Tj = -25°C ~ 125°C) UVr VCE(sat) µs Amperes °C °C 88 98 19.2 20.0 20.8 Volts Reset Level — 20.5 — Volts IC = 1200A, Tj = 25°C — Inverter Part Collector-Emitter Saturation Voltage 3.05 2.90 3.97 Volts 3.77 Volts FWDi Forward Voltage VEC -IC = 1200A, Tj = 25°C — Collector Cutoff Current ICES VCE = VCES, Tj = 25°C — — 15 mA VCE = VCES, Tj = 125°C — — 60 mA 3 Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 PM1200HCE330-1 High Voltage Intelligent Power Module 1200 Amperes/3300 Volts Thermal Characteristics Characteristics Symbol Test Conditions Min. Typ. Max. Units Thermal Resistance, Junction to Case Rth(j-c)Q Per IGBT — 0.0083 0.0100 °C/W Thermal Resistance, Junction to Case Rth(j-c)D Per FWDi — 0.0167 0.0200 °C/W Rth(c-f) Per Module, Thermal Grease Applied — 0.0075 — Symbol Test Conditions Contact Thermal Resistance °C/W Recommended Conditions for Use Characteristics Min. Typ. Inverter Supply Voltage VCC Applied between C-E 0 Control Supply Voltage VD Applied between V1-VC 21.6 Input ON Voltage VCIN(on) Applied between C1-VC 0 — Input OFF Voltage VCIN(off) — 16.0 — PWM Input Frequency fPWM 3 Phase Sinsusoidal PWM Control Arm Shoot-though Blocking Time tDEAD Reference at IPM's Input Terminals COLLECTOR-EMITTER SATURATION VOLTAGE CHARACTERISTICS (TYPICAL) 3 2 1 0 3 2 1 Tj = 25°C Tj = 125°C 500 1000 1500 COLLECTOR CURRENT, IC, (AMPERES) 2000 Volts — Volts 2.0 kHz µs — VCC = 1500V IC/-IC = 1200A Tj = 125°C EON 2 EOFF EREC 1 0 0 0 4.0 3 SWITCHING ENERGY, EON/EOFF/EREC, (J/PULSE) EMITTER COLLECTOR VOLTAGE, VEC, (VOLTS) COLLECTOR-EMITTER SATURATION VOLTAGE, VCE(sat), (VOLTS) 4 Volts SWITCHING ENERGY CHARACTERISTICS (TYPICAL) 4 VGE = 15V Tj = 25°C Tj = 125°C Volts 26.4 VD 0.5 8.0 Units 2200 24.0 — FREE-WHEEL DIODE FORWARD CHARACTERISTICS (TYPICAL) 5 1500 Max. 0 500 1000 1500 EMITTER CURRENT, IE, (AMPERES) 2000 0 500 1000 1500 EREC EMITTER CURRENT, IE, (AMPERES) 4 2000 EON/EOFF COLLECTOR CURRENT, IC, (AMPERES)