ETC PMR210ME6100M100R30

PMR210
• RC unit, class X1, metallized paper with integrated resistor
• 0.022 – 0.1 µF, 100 Ω, 250 VAC, +85 °C
•
•
•
•
RC unit for safety applications.
Small dimensions
High dU/dt capability.
Self-extinguishing encapsulation. The
material is recognized acc. to UL 94 V-0
• Good resistance to ionisation due to
impregnated dielectric.
• Excellent self-healing properties. Ensures
long life even when subjected to frequent
overvoltages.
• The impregnated paper ensures excellent
stability giving outstanding reliability
properties, especially in applications
having continuous operation.
L
Single layer metallized paper, encapsulated
and impregnated in self-extinguishing
material meeting the requirements of UL
94V-0. The resistance in the metal layer is
utilized as series resistance, integrated
resistor.
RC unit for use in DC and AC applications
for:
– contact protection
– interference suppression of contacts
– transient suppression
H
CONSTRUCTION
p ± 0.5
∅d
l
TYPICAL APPLICATIONS
R
TECHNICAL DATA
Rated voltage
250 VAC, 50/60 Hz
Capacitance range
Capacitance tolerance
0.022–0.1 µF
± 20%
Resistance range
Resistance tolerance
100 Ω
± 30%
Peak pulse voltage
1000 V
Temperature range
Climatic category
–40 to +85°C
40/085/56/B
Approvals
S, N, D, FI, VDE, SEV, UL
Series resistance
The series resistance is defined at 100 kHz
Insulation resistance
≥ 1000 MΩ
Measured at 500 VDC after 2 min, +23°C
Pulse current
Max 12 A repetitive. Max 20 A peak for occasional
transients.
Test voltage between
terminals
The 100% screening factory test is carried out at
3000 VDC. The voltage level is selected to meet the
requirements in applicable equipment standards. All
electrical characteristics are checked after the test.
In DC applications
Recommended voltage ≤ 1000 VDC.
Power ratings
The average losses may reach 0.5 W provided the
surface temperature does not exceed + 85°C. For
maximum permitted power dissipation vs temperature,
see derating curves.
198
B
C
d = 0.8 for p = 15.2 and 20.3
1.0 for p = 25.4
l: standard: 30 +5/-0 mm
option: short leads, tolerance +0/-1 mm
(standard 6 mm, code R06)
Other lead lengths on request.
Curve
Dimensions
1
1
2
3
4
B = 7.3
B = 8.5
B = 9.0
B = 11.3
B = 10.6
Pmax
W
1
0.5
0
2 3
4
Tamb
40
50
60
70
80
85 °C
Maximum allowable power dissipation vs
ambient temperature and case sizes.
PMR210
ARTICLE TABLE
Resis- Max dimensions in mm
tance
Ω
B
H
L
p
Quantity per package
reel
Weight Approvals
R30
R06
taped
pcs
pcs
pcs
g
0.022
0.033
100
100
7.3
8.5
13.0
14.3
19.0
18.5
15.2
15.2
400
300
800
500
400
350
3.0
3.8
√ √ √ √ √ √ √
√ √ √ √ √ √ √
PMR210MB5220M100R30
PMR210MB5330M100R30
0.047
0.068
100
100
9.0
11.3
15.0
16.5
24.0
24.0
20.3
20.3
200
150
1200
1000
250
180
5.0
7.0
√ √ √ √ √ √ √
√ √ √ √ √ √ √
PMR210MC5470M100R30
PMR210MC5680M100R30
0.10
100
10.6
16.1
30.5
25.4
150
1000
8.0
√ √ √ √ √ √ √
PMR210ME6100M100R30
S
N
D
FI
VDE
SEV
UL
Capacitance
µF
MARKING
APPROVALS/REFERENCE DOCUMENTS
Certification Body
Specification
Approval reference
S
FI
N
D
VDE
SEV
UL
EN 132400
EN 132400
EN 132400
EN 132400
EN 132400
EN 132400
UL 1414 Across-the-line (UR = 250 VAC)
9528106
184191-01
293103075
303424
91806
00-1928
E 73869
ENVIRONMENTAL TEST DATA
Vibration
IEC 60068-2-6 3 directions at 2 hour each
Test Fc
10 – 500 Hz at 0.75 mm
or 98 m/s2
No visible damage
No open or short circuit
Bump
IEC 60068-2-29 4000 bumps at 390 m/s2
Test Eb
No visible damage
No open or short circuit
Solderability IEC 60068-2-20 Solder globule method
Test Ta
Wetting time
for d ≤ 0.8 < 1 s
for d > 0.8 < 1.5 s
Active
EN 132400
flammability
Passive
IEC 60384-14 (1993)
flammability EN 132400
UL 1414
Enclosure material of UL 94V-0 flammability class
Humidity
IEC 60068-2-3 +40°C and 90 – 95% R.H.
Test Ca
Article code
•
•
•
•
•
•
•
•
RIFA
RIFA article code
RC unit
Rated capacitance and resistance
Rated voltage
IEC 60065
SH, for self-healing
Climatic category according to
IEC 60068-1, appendix A
• Passive flammability class
• Approval marks
• Manufacturing code (year, month)
PACKING
RC units in standard design (lead length 30
mm) and with L < 24 mm and lead length 5
or 6 mm are packed bulk in a box with
dimensions 245 x 145 x 80 mm. Quantity/
package as per article table.
RC units with L ≥ 24 mm and lead length 5 or
6 mm are packed on trays piled in a box
with dimensions 300 x 260 x 195 mm.
Quantity/package as per article table.
Reels with taped capacitors are packed 10
in a box with dimensions 370 x 370 x 560
mm. The standard quantity/reel is for 360
mm reel. If 500 mm reel is required, it must
be specified when ordering and the
quantity is 2 x the given quantity.
56 days
ORDERING INFORMATION
The article code for the standard part is given in the article table.
For other options, see page 21.
199