PHIHONG PSA-45U-201

WWW.PHIHONG.COM
38W Series Universal Input
PSA-45U Dual and Triple Output Adapter
Switching Power Supply
Features
• Universal Input from 90-264VAC • Overvoltage and Short Circuit Protection
• Built-in EMI Filter-Class B
• Compact Size
Applications
• Microcomputers
• Desktop Peripherals
• Instruments
• Test Equipment
Safety Compliance
• cUL 1950 3rd Edition
• CE
• TUV IEC950 (EN60950)
Mechanical Characteristics
Dimensions:• Length: 140mm (5.51in)
• Width: 63mm (2.48in)
• Height: 40mm (1.58in)
• Weight:0.38Kgs (0.84Ibs)
Output Specifications
Model
PSA-45U-201
DC Output
Load
Ripple(1)
Voltage
Min.
Max.
+5V
+12V
0.3A
0.2A
4.0A
1.5A
Regulation
P-P
Line
Load
50mV
120mV
+1%
+1%
+5%
+5%
(1) Ripple and noise is measured using a 12 inch twisted pair terminated with a 10µf capacitor and a 0.1µf ceramic
in parallel.
(2) Preliminary models. Coming soon.
WWW.PHIHONG.COM
PSA45U Characteristics
Temperature
Operation
0 to +40˚C
Non-Operation -25˚C to 70˚C
EMI
EN 55022 Class B
FCC Class B
VCCI Class B
GENERAL
Leakage Current
3.5mA Max.
Efficiency
70% Typical at Max. Load
and 120VAC
Dielectric Withstand (Hipot)
1500VAC for 1 min., 10mA
Switching Frequency
17-55 KHz
MTBF
>100K Hrs. at Max. Load and
240VAC 50 Hz
Mating Connectors
AC: IEC320 Cord
DC: 5p DIN, 180˚, female
A D A P T E R
INPUT
AC Input Voltage
90VAC-264VAC
AC Frequency
47 to 63Hz
AC Input Current
1.2A(rms) 120VAC at Max. Load
0.6A(rms) 240VAC at Max. Load
Max. Inrush Current
50A Max. 120VAC at Max. Load
100A Max. 240VAC at Max. Load
OUTPUT
Hold-up Time
12m Sec. Min. at Max. Load
and 120VAC
Overvoltage Protection
Zener Diode Clamping
Overcurrent Protection
Short Circuit. Auto Restart
ENVIRONMENTAL
Humidity
Operation
5-80%
Non-Operation 5-95%
Dimension Diagram Unit: mm (inch)
PSA45U/0312