ETC PWR1304DIP

Product Data Sheet
1.5 WATTS UNREGULATED
DC/DC CONVERTERS
DC/DC
CONVERTERS
PWR13XX
FEATURES
●
●
●
●
●
●
●
HIGH ISOLATION - 4000V RATING
8000V ISOLATION TEST VOLTAGE
BARRIER 100% PRODUCTION TESTED
LOW BARRIER CAPACITANCE - 10PF
LOW LEAKAGE CURRENT - 2µA MAX
24-PIN DIP PACKAGE
INTERNAL FILTERING
APPLICATIONS
●
●
●
●
●
BIOMEDICAL DATA ACQUISITION
INDUSTRIAL PROCESS CONTROL
ANALYTICAL MEASUREMENTS
GROUND LOOP ELIMINATION
INTRINSIC SAFETY SYSTEMS
DESCRIPTION
The PWR13XX Series offers a broad line of low-cost,
high-isolation voltage, unregulated, single and dual output
DC/DC converters in a 24-pin DIP package. These small
converters offer a 4000V isolation rating in a 1.25" x 0.8"
package area.
The dielectric withstand characteristics of each converter
is tested in production to ensure barrier integrity. During the
development of the PWR13XX Series extensive testing
was done to verify that subjecting the barrier to as many
as ten barrier tests will not destroy the barrier.
The PWR13XX Series uses advanced circuit design and
packaging technology to realize superior reliability and
performance. A 220kHz driven push-pull oscillator is used
to ensure stable frequency and non-saturating operation
of the input stage. This means there are no high peak
voltages or currents like other design topologies, which
can reduce unit reliability. Reliability is further enhanced
by the use of MOSPOWER transistors. These rugged
devices permit higher frequency operation with less
complicated drive circuitry than is possible with bipolar
power transistors. Reduced parts count adds to the reliability
of the PWR13XX Series.
The high efficiency of the PWR13XX Series means less
internal power dissipation. With less heat to dissipate,
the PWR13XX Series can operate over a wider ambient
temperature range with no degradation of reliable operation.
The PWR13XX Series offers the user low cost without
sacrificing reliability. The use of surface mounted devices
and manufacturing technologies make it possible to offer
premium performance and low cost. Testing of the
PWR13XX isolation barrier is performed per the methods
set forth by UL544, VDE750, CSA 22.2 and IEC 601-1.
Internet: http://www.cdpowerelectronics.com
Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Phone: 520.295.4100
Fax: 520.770.9369
PWR13XX 10/98 REV F
Power Electronics Division, Europe
C&D Technologies (Power Electronics) Ltd.
132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland
Tel: +353.61.474.133
Fax:+353.61.474.141
Page 1
ELECTRICAL SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise noted.
INPUT CURRENT
NOMINAL
INPUT VOLTAGE
RATED
OUTPUT VOLTAGE
RATED
OUTPUT CURRENT
NO LOAD
RATED LOAD
REFLECTED
RIPPLE CURRENT
(VDC)
(VDC)
(mA)
(mA)
(mA)
(mAp-p)
MODEL
PWR1300
PWR1301
PWR1302
PWR1303
PWR1304
PWR1305
5
5
5
5
5
5
5
12
15
±5
±12
±15
300
125
100
±150
±63
±50
50
50
50
50
50
50
400
400
400
400
400
400
30
30
30
30
30
30
PWR1306
PWR1307
PWR1308
PWR1309
PWR1310
PWR1311
12
12
12
12
12
12
5
12
15
±5
±12
±15
300
125
100
±150
±63
±50
30
30
30
30
30
30
167
167
167
167
167
167
25
25
25
25
25
25
PWR1312
PWR1313
PWR1314
PWR1315
PWR1316
PWR1317
15
15
15
15
15
15
5
12
15
±5
±12
±15
300
125
100
±150
±63
±50
30
30
30
30
30
30
133
133
133
133
133
133
20
20
20
20
20
20
COMMON SPECIFICATIONS
Specifications typical at TA = +25°C, rated input voltage, rated output current unless otherwise noted.
PARAMETER
CONDITIONS
INPUT
Voltage Range
ISOLATION
Rated Voltage
Test Voltage
Resistance
Capacitance
Leakage Current
OUTPUT
Rated Power
Voltage Setpoint Accuracy
Ripple & Noise
REGULATION
Line Regulation
Load Regulation
GENERAL
Efficiency
Switching Frequency
Package Weight
MTTF per MIL-HDBK-217, Rev. E
Ground Benign
Fixed Ground
Naval Sheltered
Airborne Uninhabited Fighter
TEMPERATURE
Specification
Operation
Storage
Page 2
60 Hz, 60 Seconds
MIN
TYP
MAX
UNITS
4.5
10.8
13.5
5
12
15
5.5
13.2
16.5
VDC
VDC
VDC
2
VDC
Vpk
GΩ
pF
µArms
4,000
8,000
10
10
1
VISO= 240VAC, 60Hz
1.5
40
10
Watts
%
mVp-p
mVrms
1.5
%/%
75
220
12
%
kHz
g
Circuit Stress Method
TA = +25°C
TA = +85°C
TA = +35°C
TA = +35°C
2,000,000
90,000
540,000
300,000
Hr
Hr
Hr
Hr
TA = +35°C
55,000
Hr
Rated Load, Nominal Vin
BW = DC to 10MHz
BW = 10Hz to 2MHz
±5
High Line to Low Line
See Performance Curves
-40
-55
-55
+25
+85
+100
+110
°C
°C
°C
PWR13XX 10/98 REV F
ORDERING INFORMATION
ABSOLUTE MAXIMUM RATINGS
Output Short-Circuit Duration ..................................................... 5 seconds
Internal Power Dissipation .............................................................. 750mW
Lead Temperature (soldering, 10 seconds max) ............................ +300°C
PWR
13XX
A
/H
Device Family
PWR indicates DC/DC converter
Model Number
Selected from Table of Electrical Characteristics
Package
Screening Option
MECHANICAL
TOP VIEW
.805±0.010"
(20.45)
PIN CONNECTIONS
PIN
1.270±0.010"
(32.26)
SIDE VIEW
0.400±0.010"
(10.16)
.010±0.005"
(0.25)
0.100±0.015"
(2.54)
.020±0.002"
(0.51)
0.170" MIN
(4.32)
1
2
11
12
13
14
15
23
24
SINGLE MODELS
DUAL MODELS
+VIN
+VIN
+VOUT
+VOUT
-V OUT
-V OUT
No Pin
-VIN
-VIN
+VIN
+VIN
+VOUT
+VOUT
Common
Common
-VOUT
-VIN
-VIN
Notes:
All dimensions are in inches (millimeters).
GRID: 0.100 inches (2.54 millimeters)
* Common pins not present on single output models.
BOTTOM VIEW
11 12
Marked with: specific model ordered, date code, job code.
0.600"
(15.23)
1 2
PIN PLACEMENT TOLERANCE: ± 0.015"
.1025"
(.267)
24 23
PWR13XX 10/98 REV F
MATERIAL: Units are encapsulated in a low thermal resistance
molding compound which has excellent chemical resistance, wide
operating temperature range, and good electrical properties under
high humidity environments. The encapsulant and outer shell of the
unit have UL94V-0 ratings. Lead material is brass with a solder
plated surface to allow ease of solderability.
15 14 13
Page 3
TYPICAL PERFORMANCE CURVES
Specifications at TA = +25°C, nominal input voltage, rated output current
VOUT VS LOAD
(12VOUT MODELS)
16.00
5.6
13.50
15.75
5.4
13.00
12.50
0
100%
25%
50%
12.0
75%
0
25%
50%
75%
Load (% of Rated)
Load (% of Rated)
VOUT VS LOAD
(±5VOUT MODELS)
VOUT VS LOAD
(±12VOUT MODELS)
5.8
VOUT (VDC)
5.6
5.4
100%
0
25%
50%
75%
Load (% of Rated)
100%
0
25%
50%
75%
100%
VOUT VS LOAD
(±15VOUT MODELS)
14.00
16.00
13.50
15.75
13.00
15.50
15.25
15.0
12.00
5.0
15.0
Load (% of Rated)
12.50
5.2
15.50
15.25
VOUT (VDC)
5.0
VOUT (VDC)
14.00
5.2
VOUT (VDC)
VOUT VS LOAD
(15VOUT MODELS)
5.8
VOUT (VDC)
VOUT (VDC)
VOUT VS LOAD
(5VOUT MODELS)
0
25%
50%
75%
Load (% of Rated)
100%
0
25%
50%
75%
100%
Load (% of Rated)
The information provided herein is believed to be reliable; however, C&D TECHNOLOGIES assumes no responsibility for inaccuracies or omissions. C&D TECHNOLOGIES assumes no responsibility for
the use of this information, and all use of such information shall be entirely at the user's own risk. Prices and specifications are subject to change without notice. No patent rights or licenses to any of the
circuits described herein are implied or granted to any third party. C&D TECHNOLOGIES does not authorize or warrant any C&D TECHNOLOGIES product for use in life support devices/systems or
in aircraft control applications.
Page 4
PWR13XX 10/98 REV F